[Syndromes of chronic arterial obliteration in the upper limbs].
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to J Génin.
Explore the source record for details and available documents.
Perceptual assessment of speech recognition performance with cochlear implants is confronted with problems raised by patients' availability and specificity. These problems can be avoided by using objective evaluation methods based on automatic classification of speech sounds. In the present report, different tuning strategies for the Digisonic cochlear implant were evaluated by discriminant analysis. The results presented here concern the correct classification of vowels. A set of 600 vocalic items, corresponding to 10 vowel categories and produced by 20 French speakers, were processed by the Digisonic DX10 with two different strategies. In the linear strategy, center frequencies of the 15 Digisonic channels were almost equally spaced in acoustic units (Hz). In the mel strategy, center frequencies were almost equally spaced in psychoacoustic units. For each strategy, energy levels of the frequency channels were quantified for each vocalic item and processed by statistical discriminant analysis for classification into 10 vowel categories. Results mainly show that the percent correct classification (PCC) is larger for the mel strategy and that the improvement is due to a higher concentration of frequency channels below 4 kHz. Implications of these results for the tuning of cochlear implants are discussed.
We designed a non-portable prototype seven-filter digital auditory hearing aid. For each of the filters, frequency bandwidth, amplification and compression were programmable in order to adapt these parameters to the deaf patient's audiometric characteristics. We compared the hearing improvement it was possible to obtain either with the three-analogue filter auditory prosthesis Triton 3004 hearing aid from Siemens or with our prototype as a function of the number of filters (three, four or seven) and their frequency bandwidth programmability. We tested 21 patients suffering from moderate to severe sensorineural hearing loss. This study allowed us to demonstrate that a seven programmable-width filter strategy seems to be more effective than the present analogue T004 device. Further studies with improvement of our prototype and finer audiometric adjustment of filter strategies, together with long-term clinical studies, need to be carried out.
Explore the source record for details and available documents.