Orthodontic anchorage capacity of short titanium screw implants in the maxilla. An experimental study in the dog.

The aim of this study was to investigate experimentally the effect of long term orthodontic loading on the stability as well as on the peri-implant bone findings of short titanium screw implants (Bonefit, submersion depth 6 mm, phi 4 mm) inserted in regions with reduced vertical bone height. For this purpose, 6 maxillary premolars (1P1, 2P2, 3P3) were extracted from each of 2 foxhounds and reduction of alveolar bone height was performed by osteotomy. After a 16-week healing period, 8 implants (4 per dog) were inserted in the edentulous areas. Simultaneously, 2 implants (1 per dog) were positioned in the palatal suture (one-stage surgery). After an 8-week implant healing period, the fixtures in the P1/P2 areas (n = 4) and the palate (n = 2) were loaded (test implants) by means of transpalatal bars running anteriorly, fixed on the implants in the P1/P2 areas, and Sentalloy traction springs (approximately 2 N continuous force) inserted midsagittally between palatal implants and bars (force application period: 26 weeks). The fixtures in the P2/P3 areas served as controls (n = 4). Clinical measurements and histological evaluation revealed no implant dislocation of the loaded fixtures. These results suggest that short titanium screw implants inserted in the alveolar bone and palatal suture region retain their stability during long-term orthodontic loading, even following a relatively short unloaded implant healing period. Furthermore, it seems that long-term orthodontic loading may induce marginal bone apposition adjacent to the implants.

Alveolar Process↗

The Orthosystem--a new implant system for orthodontic anchorage in the palate.

The present report describes the design and first clinical experiences of a newly developed endosseous orthodontic implant anchor system (Orthosystem, Institut Straumann, Waldenburg, Switzerland) for palatal anchorage. The 1-piece fixture made of titanium consists of a screw-type endosseous implant body (sandblasted, acid-etched, diameter 3.3 mm, lengths: 4 and 6 mm), a cylindrical polished transmucosal neck and an abutment. Clamp-caps provide attachment of square commercially available orthodontic wires (0.032 x 0.032 inch, SS) to the abutment (transpalatal bars). In a pilot study 1 fixture (implant body length: 6 mm) was inserted into the midsagittal anterior palatal region in each of 6 adult patients with Angle class II malocclusion (distocclusion 7 to 8 mm, overjet: approximately 9 mm). The treatment plan included extraction of the first maxillary premolars and retraction of the anterior teeth based on maximum anchorage of the posterior teeth without using compliance-dependent anchorage aids (headgear, class II elastics). Due to the design of the fixture only 1 simple surgical procedure was required for insertion (nonsubmerged method, 1-stage surgery). Accordingly the need for surgical exposure of the abutment for connection and wire insertion was eliminated. Thus, inconvenience to patients was reduced to a minimum. The patients are now at varying active treatment stages. The course of treatment of the most advanced case is described. Evaluation of the clinical and radiological findings after 12 months of treatment (3 months implant healing, 9 months active orthodontic treatment which is equal to the implant loading period) revealed no implant mobility/dislocation, favourable peri-implant soft tissue conditions, no marked mesial movement (approximately 0.5 mm) of the implant/transpalatal bar supported posterior teeth, and 8 mm retraction of the anterior teeth. Retrieval of the fixture and post-operative wound healing were uncomplicated. In the treatment of this case, no compliance-dependent extraoral anchorage was used, and the well aligned mandibular dentition was not bonded provide anchorage support (class II elastics).

Adolescent↗

The use of palatal implants for orthodontic anchorage. Design and clinical application of the orthosystem.

This paper presents the Orthosystem (Institute Straumann, Waldenburg/ Switzerland), a new endosseous orthodontic implant anchor system for palatal anchorage. The Orthosystem may replace compliance dependent extraoral anchoring aids for orthodontics and makes a bonding of well aligned mandibular dentition and it's use with class II elastics unnecessary. The fixture is designed for a one-stage application. It consists of an implant of pure titanium with a surface-treated, screw-shaped endosseous part of 3.3 mm diameter and lengths of 4 and 6 mm. Above the polished transmucosal neck follows as abutment where transpalatal arches made of rigid orthodontic wires (0.032 x 0.032 inch) are fixed by means of a clamp-cap. 6 patients with an angle class II malocclusion were implanted with the 6 mm fixture in the proximal midsagittal region of the palate during a pilot study. The treatment goal was extraction of the first maxillary premolars with subsequent retraction of the frontal dentition under maximal anchorage of the lateral teeth. For the implantation a simple surgical procedure of 10 min length was required while no further invasive action are needed until explantation. This way the strain on the patients was reduced to a minimum. They are now at varying stages of active treatment and the most advanced case is demonstrated here. The clinical and radiological findings after 12 months of treatment comprising 3 months of healing revealed no implant mobility or dislocation, favourable periimplant soft tissue conditions, and no marked mesial movement of the implant supported teeth. The frontal dentition was retracted by 8 mm with space closure occurring in a relatively short treatment period.

Adolescent↗

Biodegradable implants for orthodontic anchorage. A preliminary biomechanical study.

The use of endosseous implants as temporary orthodontic anchoring elements has good results in many clinical applications. The development of a new orthodontic implant anchorage system comprising an implant produced of biodegradable polylactide with a metal superstructure is described. The presented bioresorbable implant anchor for orthodontics system (BIOS) implant is designed to provide orthodontic anchoring functions in adolescents and adult patients, and to then be resorbed without a foreign body reaction or signs of clinical inflammation. Shear strength and maximum vertical strength have been measured in biomechanical in vitro tests. BIOS fixtures can be loaded with horizontal shearing forces of 50 N with a mean deflection of 0.26 +/- 0.13 mm and mean vertical removal forces of 155 +/- 80 N. Clinical studies are currently being undertaken to evaluate clinical practicability and biocompatibility of the BIOS implants.

Adolescent↗

[The development of a resorbable implant system for orthodontic anchorage. The BIOS implant system. Bioresorbable implant anchor for orthodontic systems].

The use of endosseous implants as temporary orthodontic anchoring elements has proven itself to be efficacious in many clinical applications. If, however, an implant is inserted into the jaw solely to correct a malocclusion without being used subsequently for prosthetic purposes, secondary surgery is required to remove the anchoring implant. The development of an orthodontic implant anchor system consisting of an implant made of biodegradable polylactide with a metal abutment may offer a solution to this problem. On the basis of its good mechanical properties, the BIOS implant system (bioresorbable implant anchor for orthodontics system) presented here is designed to assume orthodontic anchoring functions as long as necessary and then be resorbed by hydrolysis without foreign body reactions. Shear strength and maximum vertical strength were measured in biomechanical in vitro tests in which BIOS fixtures can be loaded with horizontal shear forces of 50 N with a mean deflection of 0.26 mm and mean vertical pull-off forces of 155 N. In a clinical case report the application of the BIOS implant system during orthodontic tooth movement is here illustrated. In vitro and in vivo results obtained to date suggest that the BIOS implant system can be used as an orthodontic anchoring system up to the time of degradation.

Absorption↗