PubMed Health⌕ Search

Biomedical subjects

J Gmeinwieser

Publications and source records attributed to J Gmeinwieser.

At least 19 recordsLinked to original sources

[Possibilities and limits of interventional therapy in necrotizing pancreatitis].

We present a new technique for minimal invasive radiological assisted necrosectomy (MIRAN) for infected necrosis in acute pancreatitis. We describe how to place volumic catheters for fragmentation and extraction of necrotic material. In addition a new technique is described for minimal invasive occlusion of selected pancreas tail to avoid fistulas. In 26 patients with infected necrosis of the pancreatic region, 12 patients (46.2%) could be healed by MIRAN alone. 5 patients (19.2%) could be satisfactory treated with a combination of MIRAN and operative necrosectomy. 9 patients (34.6%) died, 5 of them postoperatively. In 7 cases death followed multiple organ failure/dysfunction syndrome. 12 (71%) of 17 patients with the aim of curative treatment could be satisfactory treated with MIRAN. 2 other patients (12%) received additional surgery, 3 patients died (17%), 2 of them without any other treatment. The advantages of MIRAN are reduced trauma, general anaesthesia is not necessary, no difficult surgical preparation is necessary, no limits for additional therapy, reduced damage of neighbouring organs and vital pancreatic tissue as well as avoiding splenectomy.

Cause of Death↗

Spinal metastases from renal cell carcinoma: effect of preoperative particle embolization on intraoperative blood loss.

BACKGROUND AND PURPOSE: Surgical repair of spinal metastases from renal origin is often complicated by excessive bleeding. The purpose of this study was to assess the effect of preoperative particulate embolization on intraoperative blood loss. METHODS: Twenty spinal metastases from renal origin (17 patients) treated by preoperative embolization with polyvinyl alcohol particles were analyzed retrospectively. Surgical decompression was performed within 2 days after embolization. A control group of 10 patients with 11 spinal metastases of renal origin underwent surgery without embolization. The effect of preoperative embolization, of completeness of embolization, and of particle size on the estimated intraoperative blood loss was analyzed using nonparametric statistical tests. RESULTS: Complete embolization was achieved in 10 cases and partial embolization in the other 10. The estimated blood loss of 19 embolized and 11 control cases was available from the surgical report. Median intraoperative blood loss in 19 embolized lesions was 1500 mL (range, 300-8000 mL), compared with 5000 mL (range, 1440-15000 mL) in the control group. Even after partial embolization, blood loss (median, 2000 mL) was significantly lower than in the control group. No significant differences in estimated blood loss were noted between the use of particles smaller than 250 microm and those larger than 250 microm. No embolization-related permanent neurologic deficit or skin or muscle necrosis occurred. CONCLUSION: Preoperative embolization of spinal metastases of renal origin with polyvinyl alcohol particles is safe and might reduce intraoperative blood loss significantly. Even partial embolization seems to be effective.

Aged↗

Digital radiography of the skeleton using a large-area detector based on amorphous silicon technology: image quality and potential for dose reduction in comparison with screen-film radiography.

AIM: The purpose of this study was to evaluate a large-area, flat-panel X-ray detector (FD), based on caesium-iodide (CsI) and amorphous silicon (a-Si) with respect to skeletal radiography. Conventional images were compared with digital radiographs using identical and reduced radiation doses. MATERIALS AND METHODS: Thirty consecutive patients were studied prospectively using conventional screen-film radiography (SFR; detector dose 2.5 microGy). Digital images were taken from the same patients with detector doses of 2.5, 1.25 and 0.625 microGy, respectively. The active-matrix detector had a panel size of 43 x 43 cm, a matrix of 3 x 3K, and a pixel size of 143 microm. All hard copies were presented in a random order to eight independent observers, who rated image quality according to subjective quality criteria. Results were assessed for significance using the Student's t -test (confidence level 95%). RESULTS: A statistically significant preference for digital over conventional images was revealed for all quality criteria, except for over-exposure (detector dose 2.5 microGy). Digital images with a 50% dose showed a small, statistically not significant, inferiority compared with SFR. The FD-technique was significantly inferior to SFR at 75% dose reduction regarding bone cortex and trabecula, contrast and overall impression. No statistically significant differences were found with regard to over- and under-exposure and soft tissue presentation. CONCLUSION: Amorphous silicon-based digital radiography yields good image quality. The potential for dose reduction depends on the clinical query.

Aged↗

Chest radiography with a large-area detector based on cesium-iodide/amorphous-silicon technology: image quality and dose requirement in comparison with an asymmetric screen-film system.

The purpose of this study was to evaluate a large-area, flat-panel X-ray detector, which uses cesium-iodide (CsI) and amorphous silicon (a-Si). Conventional images were compared with digital images acquired with equal dose (2.5 microGy) and with 50% dose reduction. Fifteen consecutive patients were studied prospectively using an asymmetric screen-film system (detector dose, 2.5 microGy). Digital images were taken from the same patients in a posteroanterior view with detector doses of 2.5 and 1.25 microGy, respectively. The CsI/a-Si active-matrix imager had a panel-size of 43 x 43 cm, a matrix of 3 x 3k, and a pixel-pitch of 143 microm. Hard copies were presented in a random order to eight independent observers, who rated image quality according to six subjective quality criteria. Statistical significance of differences was evaluated with Student's t test for paired samples (confidence level, 95%). Digital radiographs with 2.5 and 1.25 microGy were superior to conventional images regarding all quality criteria. Statistically significant differences were observed for five of six criteria at a detector dose of 2.5 microGy and for only one quality feature at 1.25 microGy. Flat-panel digital imagers based on CsI/a-Si technique have the potential to replace conventional systems and might allow a reduction of radiation dose by 50% without loss of image quality.

Adult↗

[Digital flat image detector technique based on cesium iodide and amorphous silicon: experimental studies and initial clinical results].

PURPOSE: Experimental and clinical evaluation of a digital flat-panel X-ray system based on cesium iodide (CsI) and amorphous silicon (a-Si). METHODS: Performance of a prototype detector was compared with conventional screen-film radiography (SFR) using several phantom studies. Foreign bodies, fractures, osteolyses, and pulmonary lesions were analyzed. Additionally, 120 patients were studied prospectively, resulting in 400 comparative X-ray studies. The flat-panel detector was exposed with standard dose and with a dose reduction of up to 75%. Detector size was 15 x 15 cm, pixel matrix was 1 x 1 k with a pixel size of 143 microns. Modulation-transfer function was determined to be 18% at the maximum spatial resolution of 3.5 lp/mm. RESULTS: The diagnostic results achieved with the digital detector were similar to those of conventional SFR, even at reduced radiation exposure. A potential for dose reduction was observed: 50% with respect to osteoarthrosis and fractures, and 75% for determining bony alignment. DISCUSSION: This new technology can be used in thoracic and skeletal radiography. A significant dose reduction is possible, depending on the suspected disease.

Animals↗

[Transfemoral pelvic vein angiography with CO2: experiences with pressure- and volume-controlled injections].

PURPOSE: To evaluate the efficacy of CO2 in aortobifemoral DSA with a pressure- and volume-controlled injector. MATERIALS AND METHODS: In an intraindividual prospective study, 42 patients with arterial occlusive disease underwent stepwise aortobifemoral DSA with CO2 and with iopromid 300. RESULTS: With Co2, diagnostic images were obtained in 74% of the iliac, 98% of the femoral, 89% of the popliteal arteries, but in only 36% of the arteries of the lower leg. 73% of the stenoses were correctly identified. With therapeutic relevance 8% of the stenoses were overestimated. The length of 1 of 53 occlusions was overestimated and 3 occlusions were simulated. No stenoses or occlusion was missed. There were no severe side-effects. The injector proved to be safe and easy to handle. Fragmentation of the CO2 bolus could be compensated by postprocessing with a minimum opacification summation mode. CONCLUSIONS: With the equipment used, CO2 was a safe alternative to iodinated CM in routine stepwise aortobifemoral DSA of the iliac, femoral, and popliteal arteries. Because of the risk of overestimation, occlusions and high grade stenoses should be verified with selective injections or iodinated CM before PTA or operations.

Adult↗

[Intraabdominal abscesses. Intervention versus surgical treatment].

As the diagnosis of intraabdominal abscesses has been continuously facilitated by the use of ultrasound and CT-scan, interventional management by percutaneous drainage provides an excellent alternative treatment concept to conventional open surgery. With the use of special flow-suction-catheters which are placed into the abdomen under sonographic or computertomographic guidance, the success rates in the literature are ranging between 33% and 100%, depending on the initial situation, etiology and morphology of the findings. Studies performed with comparable patient collectives showed that interventional treatment methods had equal results to conventional surgery. Under favorable conditions such as in lesions situated in the periphery of the abdomen, with uncomplicated access ways through the abdominal wall and with an etiology of postoperative complications without a primary intraabdominal disease, with homogenous fluid collections in undivided or communicating spaces, the success rates can be raised to above 80%. A close cooperation between radiologists and surgeons in indication, conduct and course of treatment is indispensible for a successful application of these well tolerable interventional treatment concepts.

Abdominal Abscess↗

Ischiogluteal bursitis mimicking soft-tissue metastasis from a renal cell carcinoma.

We report a case of ischiogluteal bursitis mimicking a soft-tissue metastasis from a renal cell carcinoma. A 66-year-old woman suffered from pain over the left buttock 6 months after she was operated on for renal cell carcinoma of the left kidney. CT of the abdomen and pelvis revealed a tumor-like lesion adjacent to the left os ischii, which was suspected to be a soft-tissue metastasis. Percutaneous biopsy revealed no evidence of malignancy, but the histopathological diagnosis of chronic bursitis.

Aged↗

[Radiologic implantation of central venous portal systems in the forearm].

PURPOSE: To assess the safety and effectiveness of fluoroscopic guided brachial implanted central-venous miniport systems. PATIENTS AND METHODS: In 32 oncological patients a central-venous miniport system (Vital-Port, CPC-Cook) was implanted in the forearm. The group included 15 women and 17 men (range 33-78, mean 56 years). RESULTS: Technical success was 100%, in 6 patients vasospasm produced difficulties in catheter placement. In a total of 2878 patients days (range 3-445, mean 90 days) 5 complications occurred (15.6%, 1.7 on 1,000 catheterdays): In one patient (3.13%, 0.35/ 1000 d) the system was changed due to leakage of the catheter near the chamber. Four patients had minor complications: in one case excision of a suture line granuloma was necessary, one haematoma at the site of the chamber was treated with dressing, one patient had a wound dehiscence and one occluded catheter returned to patency by flushing the system with contrast material. Venous thrombosis, phlebitis, catheter dislocation, paravasation or system-related infection did not occur. CONCLUSION: Fluoroscopic guided peripheral central-venous port implantation is a safe and easy procedure with a high success rate and a low complication rate which can be performed in an outpatient setting.

Adult↗

Dedicated head-neck coil in MR angiography of the supra-aortic arteries from the aortic arch to the circle of Willis.

PURPOSE: To evaluate the usefulness of a dedicated head-neck coil in preoperative imaging of the supra-aortic arteries. MATERIAL AND METHODS: Forty consecutive patients with suspected carotid artery stenosis underwent MR angiography (MRA). Using a dedicated head-neck coil, we made a complete evaluation of the supra-aortic arteries and graded the internal carotid artery (ICA) stenoses. MRA was performed at 1.5 T with: coronal 3D FISP from the aortic arch to the circle of Willis; transverse 2D FLASH and 3D TONE of the carotid bifurcation; transverse 3D TONE of the carotid siphon and the circle of Willis; and transverse 3D FISP of the aortic arch. I.a. digital subtraction angiography (DSA) was used as the reference. ICA stenoses of 70% and more at DSA (NASCET methodology) were regarded as severe. RESULTS: Severe ICA stenoses were detected with high sensitivity and specificity: 93% and 92% respectively for coronal 3D FISP; 90% and 85% respectively for transverse 2D FLASH; and 97% and 94% respectively for transverse 3D TONE. The carotid siphon and the intracranial ICA were best depicted by 3D TONE. None of the applied sequences gave a satisfactory visualization of the aortic arch or of the origins of the vertebral arteries. CONCLUSION: With the head-neck coil, the supra-aortic arteries (including the intracranial vessels) were visualized without the need to reposition the patient, but depiction of the aortic arch was not acceptable. The quantification of ICA stenoses was reliable.

Aged↗

Amorphous silicon, flat-panel, x-ray detector versus screen-film radiography: effect of dose reduction on the detectability of cortical bone defects and fractures.

RATIONALE AND OBJECTIVES: The purpose of this phantom study was to assess the diagnostic performance of a self-scanning, solid-state amorphous silicon (a-Si) detector in skeletal radiography using different exposure parameters. METHODS: A flat-panel detector (15 cm x 15 cm), based on a-Si technology with 143 microm x 143 microm pixel size, 1k x 1k matrix, and 12 bit digital output was used. State-of-the-art screen-film radiography (SFR; speed 400, detector dose 2.5 microGy) was compared with a-Si images taken at doses that were equivalent to a speed of 400, 800, 1,250, and 1,600, respectively. A total of 232 segments of long tubular deer-bones (femur, tibia, humerus, radius) had 110 artificial fractures and 112 cortical defects simulating osteolytic lesions. Receiver operating characteristic analysis was performed for 9,280 observations made by four independent observers. Two-tailed Student's paired t test was used for statistical analysis (95% confidence level). RESULTS: Receiver operating characteristic analysis yielded equivalent results of the a-Si and SFR system. Even at the lowest dose there were no statistically significant differences between both imaging modalities with respect to the detectability of fractures and cortical defects. CONCLUSIONS: The results of this study indicate that a-Si detector technology holds promise in terms of dose reduction in skeletal radiography without loss of diagnostic accuracy.

Animals↗

Clinical application of a flat-panel X-ray detector based on amorphous silicon technology: image quality and potential for radiation dose reduction in skeletal radiography.

OBJECTIVE: The purpose of this study was to compare images obtained with a self-scanning, flat-panel X-ray detector based on amorphous silicon technology with conventional screen-film radiographs and to evaluate the possibility of radiation dose reduction in skeletal radiography. SUBJECTS AND METHODS: One hundred twenty patients were examined prospectively using a conventional screen-film system (speed, 400; detector dose, 2.5 microGy) and a prototype digital amorphous silicon detector (simulated speed, 400 and 800, n = 120; simulated speed, 1600, n = 40). The resulting 400 images were evaluated independently by six radiologists using a subjective five-point preference scale that rated overexposure, underexposure, contrast resolution, spatial resolution, and soft-tissue presentation. Image quality was ranked on a scale from 0 to 10 according to subjective criteria. Statistical significance of differences was determined using Student's t test and confidence intervals (95% confidence level). RESULTS: Comparison of conventional radiographs with digital images revealed a statistically significant preference for the digital system for soft-tissue presentation (speed 400 and 800) and visualization of osteoarthrotic changes (speed 400). A small but statistically significant preference for conventional images was found with respect to contrast and spatial resolution when digital speed was 800 or 1600; and the visibility of arthrosis at digital speed 1600, osteolysis at digital speed 800 and 1600, and fractures at digital speed 1600. CONCLUSION: The amorphous silicon-based system with a simulated speed of 400 provided images equivalent to screen-film radiographs. For clinical tasks such as routine follow-up studies, assessment of instability, or orthopedic measurements, a radiation dose reduction of up to 75% may be possible.

Aged↗

[Computer tomography-guided gastrostomy, jejunostomy and gastrojejunostomy. A reliable non-surgical method also for contraindications and failure of percutaneous endoscopic gastrostomy].

OBJECTIVE: To analyse retrospectively the results of CT (computed tomography)-guided gastrostomy or gastroenterostomy where an endoscopic procedure was not possible or had failed. PATIENTS AND METHODS: Between August 1993 and March 1997, CT-guided gastrostomy (n = 50) or gastroenterostomy (n = 8) was performed in 58 patients (mean age 56 +/- 6 years; 51 males, 7 females). An endoscopic or fluoroscopic method had been contraindicated in 52 and had failed in 6 patients. RESULTS: Technical success was achieved in all patients. Three patients needed intravenous sedation. There were no procedure related complications requiring treatment. Three patients had a mild infection at the site of the skin puncture. CONCLUSION: CT-guided gastrostomy or gastroenterostomy is a safe and simple procedure which provides a minimally invasive alternative also in patients with contraindications to the established percutaneous method.

Adult↗

Spontaneous rupture of liver in a patient with Ehlers Danlos disease type IV.

Ehlers-Danlos syndrome (EDS) type IV is an autosomal dominant connective tissue disease caused by mutations in the type III collagen gene resulting in extreme tissue fragility. Affected individuals are at risk of dramatic and often fatal complications, mostly spontaneous arterial, uterine, or colonic ruptures. Phenotypic expression of EDS type IV is variable and clinical signs are generally quite subtle, thus making a prompt diagnosis difficult. The case of a 33-year-old woman is described who presented with a wide range of clinical features and sequelae that eventually led to the diagnosis of EDS type IV. She presented with spontaneous liver rupture, renal infarction, and pneumothorax, all representing rare complications of EDS type IV. Prior history revealed a uterine rupture in advanced pregnancy associated with ischemic necrosis of the descending and sigmoid colon. EDS type IV should be suspected in young individuals who present with such unusual complications. Early diagnosis is essential if severe or even lethal complications are to be avoided in the diagnostic and therapeutic management of such patients.

Adult↗

Diagnosis of liver metastases from colorectal adenocarcinoma. Comparison of spiral-CTAP combined with intravenous contrast-enhanced spiral-CT and SPIO-enhanced MR combined with plain MR imaging.

PURPOSE: The purpose of this study was to determine whether MR with and without SPIO (AMI-25) could replace spiral-CTAP in the staging of colorectal adenocarcinoma. MATERIAL AND METHODS: Thirty-five patients were studied prospectively by means of i.v. contrast-enhanced spiral-CT, spiral-CTAP, and MR of the liver. MR imaging was performed before and after infusion of AMI-25. Diagnoses were compared to intraoperative findings (n = 35) which included intraoperative ultrasound (n = 21), and follow-up CT (n = 18). RESULTS AND CONCLUSION: Fifteen patients were found to have a total number of 53 liver metastases and 43 benign lesions were detected. Evaluation was performed in four different ways: 1) i.v. contrast-enhanced spiral-CT; 2) i.v. contrast-enhanced spiral-CT + spiral-CTAP; 3) plain MR; 4) plain MR + SPIO-enhanced MR. I.v. contrast-enhanced spiral-CT, spiral-CTAP and SPIO-enhanced MR identified patients with liver metastases with equal sensitivity. However, owing to its significantly higher sensitivity, based on a lesion-by-lesion analysis, spiral-CTAP cannot be replaced by SPIO-enhanced MR in patients who are to undergo liver resection. A limitation in spiral-CTAP is its relatively low specificity.

Adenocarcinoma↗