PubMed Health⌕ Search

Biomedical subjects

J Grifka

Publications and source records attributed to J Grifka.

At least 19 recordsLinked to original sources

The computer-assisted sequential lateral soft-tissue release in total knee arthroplasty for valgus knees.

Soft-tissue management is a critical factor in total knee arthroplasty, especially in valgus knees. The stepwise release has been based upon surgeon's experience. Computer-assisted surgery has gained increasing scientific interest in recent times and allows the intraoperative measurement of leg axis and gap size in extension and flexion. We therefore aimed to analyse the effect of sequential lateral soft-tissue release and the resulting change in the a.p. limb axis on the one hand and the tibiofemoral gaps on the other hand in extension as well as in flexion in eight cadaveric knees. Measurements were obtained using a CT-free navigation system. In extension the highest increase compared to the previous release step was found for the first (iliotibial band, P = 0.002), second (popliteus muscle, P = 0.0003), third (LCL, 0.007) and the sixth (entire PCL, P = 0.001) release step. In 90 degrees flexion all differences of the lateral release steps were statistically significant (P < 0.004). Massive progression of the lateral gap in flexion was found after the second (popliteus muscle, P = 0.004) and third (LCL, 0.007) release step. Computer-assisted surgery allows measurement of the effect of each release step of the sequential lateral release sequence and helps the surgeon to better assess the result.

Arthroplasty, Replacement, Knee↗

[Minimally invasive injection therapy in lumbar syndromes].

Minimally invasive injection therapy is an effective approach for the treatment of sciatica with less complications. This therapy is a sufficient option in cases without absolute indications for operation.The paper describes in detail the different injection techniques like spinal nerve analgesia, epidural dorsal/perineural injections, vertebral joint infiltrations, and radiculographies.

Analgesics↗

[Minimal-invasive injection therapy for cervical syndromes].

The specific minimal-invasive injection therapy is a key-procedure for cervical spine syndromes when performing a multimodal pain-therapy. Due to the exactly placed injections pain can be overcome. Indication is given in cases of continuing spine pain and is an alternative to operative procedure, as for as no absolute indication for operation is given. The complex injection technique affords knowledge and expertise. The exact application and the specific complications are presented in detail.

Analgesics↗

Precision of computer-assisted core decompression drilling of the knee.

INTRODUCTION: Core decompression by exact drilling into the ischemic areas is the treatment of choice in early stages of osteonecrosis of the femoral condyle. Computer-aided surgery might enhance the precision of the drilling and lower the radiation exposure time of both staff and patients. The aim of this study was to evaluate the precision of the fluoroscopically based VectorVision-navigation system in an in vitro model. MATERIALS AND METHODS: Thirty sawbones were prepared with a defect filled up with a radiopaque gypsum sphere mimicking the osteonecrosis. 20 sawbones were drilled by guidance of an intraoperative navigation system VectorVision (BrainLAB, Munich, Germany). Ten sawbones were drilled by fluoroscopic control only. RESULTS: A statistically significant difference with a mean distance of 0.58 mm in the navigated group and 0.98 mm in the control group regarding the distance to the desired mid-point of the lesion could be stated. Significant difference was further found in the number of drilling corrections as well as radiation time needed. CONCLUSION: The fluoroscopic-based VectorVision-navigation system shows a high feasibility and precision of computer-guided drilling with simultaneously reduction of radiation time and therefore could be integrated into clinical routine.

Decompression, Surgical↗

Stability of anterior vertebral body screws after kyphoplasty augmentation. An experimental study to compare anterior vertebral body screw fixation in soft and cured kyphoplasty cement.

The goal of this cadaver study was to compare the stability of anterior vertebral body screws after implantation in soft or cured kyphoplasty cement. Anterior vertebral body screws were inserted in a total of 30 thoracolumbar vertebrae of ten different human specimens: ten screws were implanted in non-augmented vertebrae (group 1), ten screws were placed in soft cement (group 2), and ten screws were placed in cured cement (group 3). The screws were then tested for biomechanical axial pullout resistance. Mean axial pullout strength was 192 N (range: 10-430 N) in group 1, 364 N (range: 65-875 N) in group 2, and 271 N (range: 35-625 N) in group 3. The paired Student's t-test demonstrated a significant difference between pullout strength of groups 1 and 2 (p= 0.0475). No significant difference was seen between pullout strength of groups 1 and 3 (p= 0.2646) and between groups 2 and 3 (p= 0.3863). We achieved a 1.9 times higher pullout strength with kyphoplasty augmentation of osteoporotic vertebrae compared with the pullout strength of non-augmented vertebrae. Implantation of anterior vertebral body screws in cured cement is a satisfactory method. With this method we found a 1.4 times higher pullout strength than non-augmented vertebrae.

Bone Cements↗

[Ultrasound evaluation of the acromioclavicular joint--a correlation of anatomical and sonographical findings].

AIM: To compare ultrasound imaging to the anatomy of the acromioclavicular joint. METHODS: 13 cadaveric acromioclavicular joints were examined by ultrasound (11 MHz linear array transducer) to determine the limits of the joint capsule and the width of the joint space. The results were compared to macroscopic sections. RESULTS: Anatomical variations were observed. The joint space of one specimen was completely filled by fibrous tissue, leaving 12 specimens for a complete study. A hypoechoic meniscoid disc was attached to the superior joint capsule, resulting in a convex curvature of the cranial part. The mean sonographic width of the joint space was 3.9 mm +/- 1.7 mm standard deviation (SD). The mean distance of the joint capsule from the articular bone rim of the clavicle, the acromion, and from the middle of the joint space was 1.1 +/- 1.0 mm, 1.3 +/- 0.7 mm, and 2.1 +/- 0.9 mm, respectively. The distance from the joint space to the capsular insertion on the clavicle and on the acromion was 4.4 +/- 1.4 mm and 5.3 +/- 2 mm, respectively. The mean difference between ultrasound and anatomical measurements in the vertical (cranio-caudal) plane was 0.5 +/- 0.5 mm (SD), whereas the mean difference between measurements in the horinzontal (medio-lateral) plane was 1.3 +/- 1.1 mm (SD). CONCLUSION: Due to low cost, safety and wide availability, sonography is suited for the evaluation of the acromioclavicular joint. However, when interpreting the results, errors in measuring, limitations in resolution of the system used, and the anatomy of the acromioclavicular joint and its anatomical variants have to be taken into consideration.

Acromioclavicular Joint↗

[Advances in soft tissue management in total knee arthroplasty. The use of imageless navigation systems].

Computer aided surgery has become established in the clinical routine over the past years. There are some very good studies which show that navigation optimizes reconstruction of the leg axis in total knee replacement. The question of why outliers occur in spite of navigation has to be asked. It is clear that total knee replacement is not only a bony procedure, but the soft tissues have an immense influence on postoperative stability of the prosthesis over the full range of movement. Current navigation systems allow visualization of the leg axis and size of the extension and flexion gap, and support the surgeon during soft tissue management. The current paper shows how the anatomic approach and the position of the patella influence soft tissue tension and support the surgeon during release of soft tissues in severe leg axis deformities.

Arthroplasty, Replacement, Knee↗

[Revision prosthetic of the knee joint. The influence of a navigation system on the alignment and reconstruction of the joint line].

Recognizing the rising number of primary total knee arthroplasties (TKA) over the last decade, one may assume an increasing number for revisions after a certain time delay. Studies showing a rate of only 78% satisfied patients provide a hint that there is still room for improvement. Therefore, it seemed worthwhile to evaluate the benefits of the computer assisted technique in revision TKA and compare the alignment results with the conventional technique. In a prospective study, 120 patients were operated for revision TKA using either the Vector-Vision navigation system (n=60) or the conventional technique (n=60). The axial limb alignment was evaluated on standardized pre- and postoperative full length weight-bearing radiographs and the variation of the joint line was determined by the method of Figgie from 1986.A precise reconstruction of the mechanical limb axis was achieved in 57/60 Patients (95%) in the computer assisted group and in 48/60 (80%) in the conventional group. A reconstruction of the joint line with a variation of less then 4 mm was achieved in 47/60 (78%) in the computer assisted and in 33/60 (55%) in the conventional group. Revision TKA remains a challenging procedure for the surgeon. Modern navigation systems offer additional information intraoperatively and might therefore simplify the procedure. In particular, the adjustment of the extension and flexion gap and the reconstruction of the joint line the results were superior. Furthermore, the use of a CT-free navigation system provides a significant improvement of prosthesis and leg alignment in revision TKA.

Aged↗

[Are computer assisted total knee replacements more accurately placed? A meta-analysis of comparative studies].

Computer-assisted surgery (CAS) has become established in many hospitals throughout the world, especially in the form of computer navigation for total knee replacement (TKR). Analysis of the studies available revealed 18 comparative studies examining the precision of implantation of knee endoprostheses following CAS and after implantation by the conventional technique. In a meta-analysis of 13 studies in which the same safe zone of +/-3 from neutral alignment was defined for the leg axis, a total of 1,784 TKR were performed. In the group of patients in whom the conventional technique was used, 75.6% (654/865) of TKR were implanted within the safe zone. In the CAS group 93.9% (863/919) of the prostheses were implanted within the safe zone (p<0.0001). The differences between the groups were statistically significant in 11 of the 13 studies, and the difference between groups for the entire patient population is highly significant. Only limited clinical results were ascertained in these comparative studies; there were no great differences between the treatment groups in clinical course.

Arthroplasty, Replacement, Knee↗

[Update on rheuma-orthopedics - role and therapeutic options].

Orthopaedic treatment options for rheumatological patients have been further developed over recent years. For orthopaedic treatment, a range of different interventions are offered: orthoses and special technical aids as well as injections for joints and tendons, or surgery. Surgical interventions cover joint preservation, restitution and arthrodeses. Improvements in equipment and surgical procedures also make minimally invasive interactions possible for rheumatoid diseases. Thus, postoperative morbidity has been reduced significantly. Improvement in function, reduction of pain and prevention of recurrent local inflammation are primary. Considering these aims, arthrodeses are restricted to special indications. Joint preservation and restitution are the predominant measures used. The various procedures are discussed.

Antirheumatic Agents↗

Precision of computer-assisted core decompression drilling of the femoral head.

INTRODUCTION: Osteonecrosis of the femoral head is a local destructive disease with progression into devastating stages. Left untreated it mostly leads to severe secondary osteoarthrosis and early endoprosthetic joint replacement. Core decompression by exact drilling into the ischemic areas can be performed in early stages according to Ficat or ARCO. Computer-aided surgery might enhance the precision of the drilling and lower the radiation exposure time of both staff and patients. The aim of this study was to evaluate the precision of the fluoroscopically based VectorVision navigation system in an in vitro model. MATERIALS AND METHODS: Thirty sawbones were prepared with a defect filled up with a radiopaque gypsum sphere mimicking the osteonecrosis. Twenty sawbones were drilled by guidance of an intraoperative navigation system VectorVision (BrainLAB, Munich, Germany) and 10 sawbones by fluoroscopic control only. RESULTS: No gypsum sphere was missed. There was a statistically significant difference regarding the three-dimensional deviation (Euclidian norm) as well as maximum deviation in x-, y- or z-direction (maximum norm) to the desired mid-point of the lesion, with a mean of 0.51 and 0.4 mm in the navigated group and 1.1 and 0.88 mm in the control group, respectively. Furthermore, significant difference was found in the number of drilling corrections as well as the radiation time needed: no second drilling or correction of drilling direction was necessary in the navigated group compared to 1.4 in the control group. The radiation time needed was less than 1 s compared to 3.1 s, respectively. CONCLUSION: The fluoroscopy-based VectorVision navigation system shows a high feasibility of computer-guided drilling with a clear reduction of radiation exposure time and can therefore be integrated into clinical routine. The additional time needed is acceptable regarding the simultaneous reduction of radiation time.

Decompression, Surgical↗

[Prevention of deep vein thrombosis in total knee replacement--current status of therapy in orthopedie and trauma departments in Germany].

INTRODUCTION: Symptomatic deep vein thrombosis is a serious complication after total knee arthroplasty, with a risk of about 4-5% despite prevention with herparin. Aim of the current study was to find out about the actual status of thrombosis prophylaxis in Germany after total knee replacement. MATERIAL AND METHODS: In a countrywide survey 470 German trauma and orthopaedic surgery departments were asked about their prophylactic procedures addressing deep vein thrombosis after total knee replacement. RESULTS: 98% perform prevention of thrombosis with low-molecular-weight heparin, 2% use unfractioned heparin. Low-molecular-weight heparin is applicated in standard doses in 48% and in 44% according to patient's weight. In 82% the prophylaxis is begun the night before surgery. The therapy is carried out for 4.7 weeks in mean. 96% use graduated compressions stocking as additional therapeutic option. CONCLUSION: Our survey shows that most of the surgeons perform prevention of deep vein thrombosis according to the official guidelines.

Arthroplasty, Replacement, Hip↗

[Pullout resistance of conventional pedicle screw implantation in comparison to fluoroscopic computer-assisted technique].

AIM: Aim of the study was to compare pullout resistance of pedicle screws after conventional and fluoroscopic computer-assisted implantation in the cadaveric thoracic and lumbar spine. METHODS: Pedicle screws were inserted in a total of 10 vertebrae of different human specimens: 10 screws were placed using conventional technique (group 1) and 10 screws were inserted with fluoroscopic computer-assisted system contralaterally (group 2). Then pedicle screws were evaluated for biomechanical axial pullout resistance. RESULTS: Mean pullout force was 232 N (range 60-600 N) in group 1 and 353 N (range 112-625 N) in group 2. The difference was significant (p=0,0425). CONCLUSION: Fluoroscopic navigated implantation of pedicle screws increases the pullout strength in thoracic and lumbar cadaveric spines as compared with conventional methods.

Aged↗

Imageless navigation for insertion of the acetabular component in total hip arthroplasty: is it as accurate as CT-based navigation?

In a prospective randomised clinical study acetabular components were implanted either freehand (n = 30) or using CT-based (n = 30) or imageless navigation (n = 30). The position of the component was determined post-operatively on CT scans of the pelvis. Following conventional freehand placement of the acetabular component, only 14 of the 30 were within the safe zone as defined by Lewinnek et al (40 degrees inclination sd 10 degrees ; 15 degrees anteversion sd 10 degrees ). After computer-assisted navigation 25 of 30 acetabular components (CT-based) and 28 of 30 components (imageless) were positioned within this limit (overall p < 0.001). No significant differences were observed between CT-based and imageless navigation (p = 0.23); both showed a significant reduction in variation of the position of the acetabular component compared with conventional freehand arthroplasty (p < 0.001). The duration of the operation was increased by eight minutes with imageless and by 17 minutes with CT-based navigation. Imageless navigation proved as reliable as that using CT in positioning the acetabular component.

Acetabulum↗

Computer assistance in total knee replacement - a critical assessment of current health care technology.

The last five years have seen the rapid development of computer assisted surgery (CAS) in total knee replacement (TKR). Many surgeons perform TKR using navigation systems, which offer user-friendly workflows and reproducible results. A number of level 1 and 2 studies, according to evidence-based medicine criteria, have demonstrated that navigation in TKR allows a more precise implantation of the prosthesis, though CAS still requires an experienced surgeon and is time consuming. Nevertheless, 30% of surgeons in Germany who perform TKR have used navigation. It is still not known whether this new technique improves the longevity of TKR, however, and we therefore performed a meta-analysis to assess the results of this new health care technology.

Arthroplasty, Replacement, Knee↗