PubMed Health⌕ Search

Biomedical subjects

J Groswasser

Publications and source records attributed to J Groswasser.

At least 19 recordsLinked to original sources

Factors influencing the determination of arousal thresholds in infants - a review.

Objective: To review the major confounding factors that influence the determination of arousal thresholds in infants.Review of confounding factors: The determination of arousal thresholds in infants measures their arousability from sleep. The evaluation is influenced by various conditions. The infant's arousability is decreased by maternal factors, such as exposure to cigarette smoke, alcohol, illegal drugs or medications during gestation or breastfeeding. The levels of arousal thresholds also depend on the age of the infant and on experimental conditions, such as previous sleep deprivation, type of arousal challenges, time of administration of the arousal challenge, sleep stage, body position, room temperature, use of a pacifier, bed sharing, or type of feeding. In addition, spontaneous arousals can occur and modify the infant's response to external arousal challenges.Conclusions: Factors known to modify infants' arousability from sleep should be controlled during studies designed to determine arousal thresholds.

Journal Article↗

Frequency of obstructive and mixed sleep apneas in 1,023 infants.

STUDY OBJECTIVES: To collect normative data on the frequency of obstructive and mixed sleep apneas in healthy infants. STUDY DESIGN: 1100 infants were recorded during one night in a sleep laboratory. SETTING: the recordings were performed in an infant sleep laboratory. PATIENTS: The recordings of 1023 infants were used for analysis, the data of 77 infants being excluded because of poor recording quality. The infants were born full-term, were healthy at the time of study, had no history of apnea and were aged between 2 and 28 weeks. The polysomnographic recordings were analyzed visually and were subdivided according to the age of the subjects into 2-7 weeks, 8-11 weeks, 12-15 weeks, 16-19 weeks and 20-27 weeks of life. INTERVENTIONS: NA. MEASUREMENTS AND RESULTS: At 2-7 weeks of life, obstructive apneas (p=.013) and mixed apneas (p=.004) were significantly more frequent than at any other age group. At 8 to 11 weeks of life, obstructive apneas were significantly more frequent in boys than girls (p=.016). CONCLUSIONS: The present findings add to our knowledge of infants' respiratory characteristics during sleep.

Female↗

[Autopsy practices in cases of sudden infant death syndrome in the French-speaking community of Belgium and comparison with other European countries].

This work summarises the current difficulties encountered in performing autopsies in cases of sudden unexplained infant deaths in Belgium. Over the last few years, the incidence of postneonatal deaths in most European countries has significantly decreased, probably due to prevention campaigns. However, there are still many difficulties encountered in systematically including autopsies in the general strategy for managing this public health problem. The analysis of autopsy practices in Belgium in cases of unexplained infants' deaths and their comparison with other European countries' practices give us the opportunity to propose changes in order to improve policies and the overall understanding of these unexplained deaths.

Autopsy↗

Naso-oesophageal probes decrease the frequency of sleep apnoeas in infants.

The objective of the study was to determine whether a naso-oesophageal probe modifies sleep and cardiorespiratory patterns in infants with repeated obstructive apnoeas. Two polygraphic recording sessions were conducted in random order for 2 nights on 35 infants suspected to have repeated obstructive sleep apnoeas. One sleep study was performed with a pH probe inserted through the nasal passage down to the distal portion of the oesophagus. The other session was conducted without any naso-oesophageal probe (the baseline study). For the 25 infants who presented repeated obstructive apnoeas during baseline studies, the presence of the probe was associated with a small, but significant, decrease in the number of central apnoeas (median frequency of 18.5 apnoeas per hour without a probe; 16.1 per hour with the probe; P=0.040), and obstructive apnoeas (median of 1.9 apnoeas per hour without a probe; 0.6 per hour with the probe; P=0.016). The presence of the probe was also associated with a small increase in percentage non-rapid eye movement (NREM) sleep frequency. The changes were statistically significant only for infants who had no obstructive apnoea during baseline studies (29 vs. 31%). The presence of a naso-oesophageal probe significantly modifies the infants' respiratory characteristics during sleep. These findings should be considered when reporting and interpreting sleep studies in infants.

Airway Obstruction↗

The influence of a pacifier on infants' arousals from sleep.

OBJECTIVE: The risk of sudden infant death during sleep was postulated to decrease with the use of a pacifier and by conditions facilitating arousals from sleep. We evaluated the influence of a pacifier on arousal from sleep in healthy infants. STUDY DESIGN: Fifty-six healthy infants were studied with polygraphy during 1 night; 36 infants used a pacifier regularly during sleep, and 20 never used a pacifier. Thumb users or occasional pacifier users were not included in the study. The infants were recorded at a median age of 10 weeks (range 6 to 19 weeks). To evaluate auditory arousal thresholds, the infants were exposed to white noise of increasing intensity during rapid eye movement sleep. RESULTS: Polygraphic arousals occurred at significantly lower auditory stimuli in pacifier users than in nonusers (P =.010). Compared with nonusers, pacifier users were more frequently bottle-fed than breast-fed (P =. 036). Among infants sleeping without a pacifier, breast-fed infants had lower auditory thresholds than bottle-fed infants (P =.049). CONCLUSIONS: Infants using pacifiers during sleep had lower auditory arousal thresholds than those who did not use a pacifier during sleep. Breast-feeding could be a further factor contributing to lower arousal thresholds. These findings could be relevant to the occurrence of sudden infant deaths during sleep.

Arousal↗

Prenatal exposure to cigarette smoking is associated with a decrease in arousal in infants.

OBJECTIVE: Sudden infant death syndrome has been related to both exposure to prenatal cigarette smoke and impaired arousability from sleep. We evaluated whether healthy infants born to mothers who smoked during pregnancy had higher auditory arousal thresholds than those born to mothers who did not smoke and whether the effects of smoking occurred before birth. STUDY DESIGN: Twenty-six newborns were studied with polygraphic recordings for 1 night: 13 were born to mothers who did not smoke, and 13 were born to mothers who smoked (>9 cigarettes per day). Other infants with a median postnatal age of 12 weeks were also studied, 21 born to nonsmoking mothers and 21 born to smoking mothers. White noise of increasing intensity was administered during rapid eye movement sleep to evaluate arousal and awakening thresholds. RESULTS: More intense auditory stimuli were needed to induce arousals in newborns (P =.002) and infants (P =. 044) of smokers than in infants of nonsmokers. Behavioral awakening occurred significantly less frequently in the newborns of smokers (P =.002) than of nonsmokers. CONCLUSIONS: Newborns and infants born to smoking mothers had higher arousal thresholds to auditory challenges than those born to nonsmoking mothers. The impact of exposure to cigarette smoke occurred before birth.

Arousal↗

Auditory arousal thresholds are higher when infants sleep in the prone position.

OBJECTIVE: To evaluate the possibility that infants sleeping in the prone position have higher arousal thresholds to auditory challenges than when sleeping in the supine position. STUDY DESIGN: Polygraphic recordings were performed for 1 night in 25 healthy infants with a median age of 9 weeks. The infants were exposed to white noises of increasing intensities while sleeping successively in the prone and supine positions, or vice versa. Arousal thresholds were defined by the auditory stimuli needed to induce polygraphic arousals. RESULTS: Three infants were excluded from the study because they awoke while their position was being changed. For the 22 infants included in the analysis, more intense auditory stimuli were needed to arouse the infants in the prone position than those in the supine body position (p = 0.011). Arousal thresholds were higher in the prone than in the supine position in 15 infants; unchanged in 4 infants; and lower in the prone position in 3 infants (p = 0.007). CONCLUSIONS: Infants show higher arousal thresholds to auditory challenges when sleeping in the prone position than when sleeping in the supine position. The finding could be relevant to mechanisms concerned with the reported association between sudden deaths and the prone sleeping position in infants.

Auditory Threshold↗

Development of cardiopulmonary integration and the role of arousability from sleep.

The recent literature on cardiopulmonary integration in infants is surveyed here, focusing on arousals from sleep. Recent studies reported that the ontogenicity of cardiopulmonary integration cannot be evaluated independently from that of sleep-wake cycles. The issue is of importance for researchers and clinicians evaluating cardiorespiratory characteristics in infants. It also has significant implications in the understanding of clinical conditions, such as parasomnias, obstructive sleep apneas, or some cases of sudden infant death syndrome. The propensity to arouse can be evaluated by exposing the sleeper to awakening challenges. Arousal thresholds are determined by measuring the intensity of the stimulus needed to induce arousals. However, these studies are complicated by factors such as the scoring of the arousal responses. Another difficulty lies in the choice and modality of the arousal stimulus. Noise, gases, light, and nociceptive, mechanical, chemical, or temperature stimuli have all been used to induce arousals. Confounding factors modify the sleeper's responses to a given stimulus. Prenatal drug, alcohol, or cigarette use and the infant's age or, previous sleep deprivation also modify thresholds. Other confounding factors include time of the night, sleep stages, the sleeper's body position, and sleeping conditions. Arousal can also occur spontaneously because of endogenous stimuli. The literature surveyed here also covers such unresolved issues as the clinical significance of aborted arousals, or the mechanisms responsible for the arousal reactions.

Age Factors↗

Normal sleep architecture in infants and children.

Because the collection of normative sleep data in the pediatric age group largely depends on technical issues, this article discusses various aspects of sleep recordings in infants and children. Polygraphic monitoring of sleep and waking behavior contributes to a better description of maturational stages in children, from the prenatal period to the end of adolescence. This article reviews the general characteristics of normal children's sleep and the environmental factors that influence these maturational processes. The use of polygraphic recordings to identify neurological deficits and to predict behavioral and neurological outcome in infants and children, however, does not hold great promise. The importance of polysomnographic evaluation is admitted for some major clinical conditions, such as risks for abnormal breathing or narcoleptic attacks.

Adolescent↗

Decreased cardiac responses to auditory stimulation during prone sleep.

OBJECTIVE: To evaluate the relationship between body position during sleep and the infants' cardiac responses to auditory stimulation. METHODS: Thirty healthy infants with a median age of 11 weeks were studied polygraphically for one night, while sleeping successively prone and supine, or vice versa. Their behavioral and cardiac responses were recorded during rapid eye movement (REM) sleep, both before and after exposure to 90 dB (A) of white-noise. RESULTS: Ten infants were excluded from the study, because they woke up during the challenge. For the 20 infants included in the analysis, no significant difference was seen between the prone and the supine position for total sleep time, sleep efficiency, percent of REM and nonrapid eye movement sleep, number of gross body movements, transcutaneous oxygen saturation levels, mean cardiac rate, heart rate variability, number of heart rate drops; mean respiratory rate, and number or duration of central or obstructive apneas. Auditory challenges induced significantly less overall changes in heart rate, less heart rate drops, less heart rate variability, as well as fewer and shorter central apneas in the prone than in the supine position. Autoregressive power spectral analysis of the heart rate was consistent with a possible increase in orthosympathetic tone in the prone position. CONCLUSION: Prone sleeping was associated with a decrease in cardiac responses to auditory stimulation and a possible increase in orthosympathetic activity. Prone positioning could favor a reduced reactivity to danger-signaling stimuli during REM sleep.

Acoustic Stimulation↗

Reduction in obstructive breathing events during body rocking: a controlled polygraphic study in preterm and full-term infants.

OBJECTIVE: To investigate the effect of body rocking on infant respiratory behavior during sleep. METHODS: Eighteen infants with documented obstructive sleep apneas were studied. There were eight premature infants with persistent bradycardias and 10 infants born full-term, admitted after an idiopathic apparent life-threatening event. No cause for the obstructive apneas was found. The infants were recorded with polygraphic techniques during two successive nights. They were randomly assigned to a rocking or a nonrocking mattress. The conditions were reversed the following night, in a crossover design. RESULTS: In both groups of infants, no significant difference was seen between the two consecutive nights for most of the variables studied: total sleep time, the proportion of non-rapid-eye-movement and rapid-eye-movement sleep, the number of arousals, the number and maximal duration of central apneas, the frequency of periodic breathing, the level of oxygen saturation, and heart rate. During the nonrocking nights, all infants had repeated obstructive breathing events. In seven of the eight preterm infants and in nine of the 10 full-term subjects, body rocking was associated with a significant decrease in the frequency of obstructive events. During rocking, in the preterm infants the obstructions fell from a median of 2.5 to 1.8 episodes per hour (P = .034). In the full-term infants, rocking reduced the obstructive events from a median of 1.5 obstructions per hour to 0.7 (P = .005). No difference was seen for the duration of the obstructive episodes. CONCLUSION: In preterm and full-term infants prone to obstructive sleep apneas, gentle side-to-side body rocking is associated with a significant decrease in the frequency of upper-airway obstructions.

Beds↗

Mechanisms of obstructive sleep apneas in infants.

During sleep, infants with obstructive sleep apneas are characterised by snoring, laborious breathing, and profuse sweating. During wakefulness, they may have breath-holding spells, and during feeding, difficult breathing and swallowing coordination. Abnormal weight, difficult growth, and recurring ear infections may also develop. During sleep apneas, cinefluoroscopy shows approximation of tongue and hypopharyngeal tissues, with an obliteration of the air space. The obstructed breaths occur mainly in REM, and light NREM sleep, associated with total short sleep time, and frequent arousals. Preterm infants, and term neonates are more prone to obstructive apneas than older healthy infants. Apneas are more frequently seen in boys and in case of excess in body weight. Obstructive apneas are frequently associated with upper airway anatomic abnormalities: malformations, soft tissue infiltration, and neurologic lesions impairing muscle contractions. Alterations of the autonomic nervous control may induce airways obstructions. Contributing factors include mucopolysaccharide storage disease, hypothyroidism, or Down's syndrome. Superimposed factors may occur, such as nasal obstruction, secretions in the airways, or tissue edema. Pressure- and chemo-sensitive reflexes may also favor obstruction. Environmental factors also contribute to the development of sleep apneas: body position, neck flexion, sleep deprivation, or the effects of sedative drugs.

Airway Resistance↗

Polygraphic evaluation of night-to-night variability in sleep characteristics and apneas in infants.

The study was designed to evaluate whether results of a single overnight recording session are sufficient for the study of sleep profiles and detection of apneas in infants, or whether it would be beneficial to extend the recording period. Nineteen infants were recorded during successive nights. Eight of the 19 infants were studied after an idiopathic apparent life-threatening event, whereas the other 11 were healthy. There were 13 boys and six girls, with a median age of 11 weeks (range 5-36 weeks). All infants were recorded polygraphically during 2 nights, and 11 were recorded during 3 successive nights. No significant difference was observed between any of the following variables, regardless of the number of nights for which the recording was performed: total recording time, total sleep time, delay in sleep onset, time awake, percent of rapid eye movement or nonrapid eye movement sleep, mean respiratory rates, density and duration of central, obstructive or mixed apneas. The frequency of obstructed breathing events for each infant did not differ significantly from 1 night to the next. The present study indicates that under adequate study conditions, recordings of a single night can reliably describe the frequency of central and obstructive apneas in infants.

Arousal↗

Prenatal exposure to cigarettes in infants with obstructive sleep apneas.

OBJECTIVE: To investigate the effect of prenatal smoking on infant respiratory behavior during sleep. METHODS: A questionnaire concerning family habits and infants' history was completed for 550 healthy infants before a 9-hour night polysomnographic study. Because the data for 41 infants were not available for analysis, 509 subjects were studied: 115 were newborns evaluated within 1 week after birth, and 394 were healthy infants admitted at 11 weeks of life (range 5 to 29 weeks) after various research protocols. RESULTS: According to the smoking frequency of the mothers during pregnancy, the subjects were defined as "nonsmokers" (no cigarette smoked during pregnancy; n = 400), "light smokers" (1 to 9 cigarettes per day; n = 37), or "smokers" (10 or more cigarettes per day; n = 72). Compared with nonsmokers and light smokers, "smoking" mothers had a significant increase in the number of episodes of uterine bleeding during the pregnancy. Their infants had lower birth weights and more frequent episodes of profuse sweating during sleep. Infants of smokers also had more frequent and longer obstructive sleep apneas than those of the two other groups. For infants of smokers the relative risk for obstructive apneas was 2.76 (95% confidence interval: 1.63 to 4.69; P = .001). The relation between prenatal smoking and postnatal manifestation of obstructive sleep apneas demonstrated a dose-response pattern. Paternal smoking during pregnancy increased the risk of obstructive apneas only in the infants of smoking mothers, but not in those of the two other groups. Maternal smoking after birth did not add significantly to the risk of obstructive apneas. The effect of smoking was seen in older infants, as well as in the newborn not yet exposed to ambient cigarette smoke. A stepwise logistic regression, using obstructive sleep apneas as the dependent variable identified three significant independent variables: smoking during pregnancy (P = .001), profuse sweating during sleep (P = .001), and birth weight (P = .010). No explanation was found for the effect of prenatal smoking on obstructive sleep apneas. CONCLUSION: Prenatal smoking by mothers correlated with an increase in frequency and length of obstructive apneas and a decrease in birth weight of their infants. The infants were under greater risk for obstructive apnea if both parents smoked. Explanations for our results are unknown to us, but these findings may be of interest in the study of infant breathing behavior and epidemiological characteristics of sudden infant death syndrome.

Adolescent↗

Clinical symptoms associated with brief obstructive sleep apnea in normal infants.

Relatively little data exist concerning the manifestations of repeated obstructive sleep apnea in normal infants. A questionnaire concerning daytime and sleep habits was completed by the parents of 4,100 healthy infants before they underwent a 9-hour night monitoring study. One hundred infants with an obstructive apnea index above 1.2 were randomly selected. They formed the "apnea" group. From the initial population, 300 infants with no apnea were also selected to form the "no-apnea" group. Both groups were matched for sex, gestational age, post conceptional age, birth weight, mother's age, parity and a family history of sudden infant death. Five variables from the questionnaires significantly differentiated the two groups of infants. When awake, the infants with apnea were characterized by a greater frequency of breathholding spells (22% of apnea infants) and episodes of fatigue during feeding (28%) than the non-apnea infants. During sleep, they exhibited a greater frequency of profuse sweating (15%), snoring (26%) or noisy breathing (44%). Multiple symptoms were present in some infants. A stepwise logistic regression resulted in two significant independent variables: profuse sweating during sleep (p = 0.008) and noisy breathing (p = 0.002). The predictive value of these two symptoms was tested on a new group of 650 healthy infants. The two independent variables led to the correct classification of 60 of the 67 infants with apnea (89.67%) and 382 of the 583 non-apnea infants (65.5%). A positive history alone had a positive predictive value of 0.21.(ABSTRACT TRUNCATED AT 250 WORDS)

Electrocardiography↗