MR imaging of articular cartilage at 1.5T and 3.0T: comparison of SPGR and SSFP sequences.

OBJECTIVE: To compare articular cartilage signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and thickness measurements on a 1.5 T and a 3.0 T magnetic resonance (MR) scanner using three-dimensional spoiled gradient recalled echo (3D-SPGR) and two 3D steady-state free precession (SSFP) sequences. METHODS: Both knees of five volunteers were scanned at 1.5 T and at 3.0 T using a transmit-receive quadrature extremity coil. Each examination consisted of a sagittal 3D-SPGR sequence, a sagittal fat suppressed 3D-SSFP (FS-SSFP) sequence, and a sagittal Dixon 3D-SSFP sequence. For quantitative analysis, we compared cartilage SNR and CNR efficiencies, as well as average cartilage thickness measurements. RESULTS: For 3D-SPGR, cartilage SNR efficiencies at 3.0 T increased compared to those at 1.5 T by a factor of 1.83 (range: 1.40-2.09). In comparison to 3D-SPGR, the SNR efficiency of FS-SSFP increased by a factor of 2.13 (range: 1.81-2.39) and for Dixon SSFP by a factor of 2.39 (range: 1.95-2.99). For 3D-SPGR, CNR efficiencies between cartilage and its surrounding tissue increased compared to those at 1.5 T by a factor of 2.12 (range: 1.75-2.47), for FS-SSFP by a factor 2.11 (range: 1.58-2.80) and for Dixon SSFP by a factor 2.39 (range 2.09-2.83). Average cartilage thicknesses of load bearing regions were not different at both field strengths or between sequences (P>0.05). Mean average cartilage thickness measured in all knees was 2.28 mm. CONCLUSION: Articular cartilage imaging of the knee on a 3.0 T MR scanner shows increased SNR and CNR efficiencies compared to a 1.5 T scanner, where SSFP-based techniques show the highest increase in SNR and CNR efficiency. There was no difference between average cartilage thickness measurements performed at the 1.5 T and 3.0 T scanners or between the three different sequences.

Adult↗

Prospective MR signal-based cardiac triggering.

A cardiac motion compensation method using magnetic resonance signal-based triggering is presented. The method interlaces a triggering pulse sequence with an imaging sequence. The triggering sequence is designed to measure aortic blood velocity, from which cardiac phase can be inferred. The triggering sequence is executed repeatedly and the acquired data processed after each sequence iteration. When the desired phase of the cardiac cycle is detected, data are acquired using the imaging sequence. A signal-processing unit of a conventional scanner is used to process the triggering data in real time and issue triggering commands. Alternatively, a workstation, with a bus adaptor, can access data as they are acquired, process and display the data, and issue triggering commands. With a graphical user interface, the triggering pulse sequence and data-processing techniques can be modified instantaneously to optimize triggering. The technique is demonstrated with coronary artery imaging using both conventional two-dimensional Fourier transform scans and spiral trajectories.

Aorta, Thoracic↗

Three-dimensional flow-independent peripheral angiography.

A magnetization-prepared sequence, T2-Prep-IR, exploits T1, T2, and chemical shift differences to suppress background tissues relative to arterial blood. The resulting flow-independent angiograms depict vessels with any orientation and flow velocity. No extrinsic contrast agent is required. Muscle is the dominant source of background signal in normal volunteers. However, long-T2 deep venous blood and nonvascular fluids such as edema also contribute background signal in some patients. Three sets of imaging parameters are described to address patient-specific contrast requirements. A rapid, spiral-based, three-dimensional readout is utilized to generate high-resolution angiograms of the lower extremities. Comparisons with x-ray angiography and two-dimensional time-of-flight angiography indicate that this flow-independent technique has unique capabilities to accurately depict stenoses and to visualize slow flow and in-plane vessels.

Angiography↗

Coronary angiography with magnetization-prepared T2 contrast.

A magnetization-prepared, T2-weighted sequence (T2 Prep) is used to suppress muscle and venous structures. When combined with lipid suppression, this technique improves the visualization of the coronary arteries. T2 Prep was designed to be rebust in the presence of flow as well as B0 and B1 inhomogeneities and may be combined with virtually any imaging technique. Here, it is implemented with both a single-slice spiral acquisition and a multi-slice spiral method that acquires up to 15 slices in a single breath-holding interval.

Arteries↗

Oxygen saturation of blood in the superior mesenteric vein: in vivo verification of MR imaging measurements in a canine model. Work in progress.

PURPOSE: To evaluate the accuracy of magnetic resonance (MR) imaging in estimating oxygen saturation of blood (%HbO2) in the superior mesenteric vein (SMV) of a canine model in vivo. MATERIALS AND METHODS: MR imaging was used to measure the T2 of blood in samples obtained via a catheter placed in the SMV in seven mongrel dogs. %HbO2 was measured with a reflectance oximeter. These measurements were obtained at the resting state, during superior mesenteric artery occlusion, and after reperfusion. MR imaging and oximeter measurements were then compared by using linear regression analysis. RESULTS: Refocusing intervals (tau 180) of 12 and 24 msec were used for 17 and 18 %HbO2 measurements with MR imaging, respectively. With tau 180 of 12 msec, there was an excellent correlation between MR imaging measurements and oximeter measurements (r = .969). The intercept was 5.3% and the slope was 0.959. With tau 180 of 24 msec, r = .953, the intercept was 15.4%, and the slope was 0.817. CONCLUSION: Estimates of %HbO2 in the SMV with MR imaging are accurate in the range of most clinical interest.

Animals↗