Effectiveness of bone cement containing tobramycin. An in vitro susceptibility study of 99 organisms found in infected joint arthroplasty.

We used 99 strains of organisms representative of orthopaedic infections to examine the effectiveness of a bone cement containing tobramycin, employing a modified in vitro Kirby-Bauer susceptibility model. The spectrum was broad, including Gram-positive and Gram-negative aerobic organisms, anaerobes and mycobacteria. Simplex P with added tobramycin was effective against most of the strains, including those which are resistant to typical systemic levels of tobramycin. Although direct correlation between in vitro and in vivo results is difficult, the study showed that tobramycin is stable to the exothermic polymerisation of the cement, and that it is released from the surface of the cement at concentrations high enough to inhibit the growth of most organisms which may be encountered after joint arthroplasty.

Anti-Bacterial Agents↗

Effect of femoral head surface roughness on the wear of ultrahigh molecular weight polyethylene acetabular cups.

We studied the effect of femoral head surface roughness on the wear of ultrahigh molecular weight polyethylene (UHMWPE) acetabular cups using a hip joint simulator and a reciprocating wear tester. Compared with the hip simulator, the reciprocating wear tester severely exaggerates the effect of counterface roughness on UHMWPE wear and drastically underestimates the wear rate of the UHMWPE against smooth undamaged counterfaces. According to the hip simulator test results, the wear rate of the UHMWPE cups is approximately proportional to the square root of the femoral head roughness Ra (center-line-average roughness) rather than to Ra raised to a power greater than one as predicted by pin-on-disk studies. Roughening of the femoral heads by an order of magnitude results in a 2- to 3-fold increase in the wear rate. Therefore, the much wider clinical variations of wear cannot be fully explained by variations in surface roughness of the femoral heads.

Acetabulum↗

Comparison of the size and morphology of UHMWPE wear debris produced by a hip joint simulator under serum and water lubricated conditions.

This paper investigates the effect of lubricant on the size and morphology of ultra-high molecular weight polyethylene (UHMWPE) wear debris produced by a hip joint simulator. Bovine serum and water were chosen as the lubricants for comparison. When bovine serum was used as lubricant, the majority of the wear debris produced was submicron sized and equiaxed or elongated in shape; no transfer film was found on the femoral heads. When water was used as lubricant, large pieces of thin UHMWPE flakes about 2-3 mm across were produced and patches of transfer films were observed on the femoral heads. These large flakes were comprised of numerous smaller thin flakes compacted together. While the size and shape of the wear debris produced with serum lubrication are similar to those reported from clinical studies in total hip replacement, the debris produced with water lubrication bears no resemblance to what has been seen clinically.

Animals↗

The artificial disc: theory, design and materials.

Low back pain is one of the most common medical conditions in the Western world. Disc degeneration, an inevitable process of aging, of variable rate and degree, is one of the major causes of low back pain. Currently, there are two major surgical interventions for treating conditions related to the degenerative disc: discectomy and fusion. Although discectomy and fusion produce a relatively good short-term clinical result in relieving pain, both these surgical treatments alter the biomechanics of the spine, possibly leading to further degeneration of the surrounding tissues and the discs at adjacent levels. Over the past 35 years, a tremendous effort has been made to develop an artificial disc to replace the degenerated disc. The goal is the restoration of the natural biomechanics of the segment after disc excision, thus relieving pain and preventing further degeneration at adjacent segments. However, the artificial disc faces a complex biomechanical environment which makes replication of the biomechanics difficult and long-term survival challenging to designs and materials. The purpose of this article is to examine the factors of importance in designing a disc replacement. Topics covered include the structure and function of the natural disc, the changes that occur with disc degeneration and existing methods of treatment for the degenerative spine. The progress in achieving a functional, long-lasting disc replacement is outlined.

Humans↗

Mechanistic and morphological origins of ultra-high molecular weight polyethylene wear debris in total joint replacement prostheses.

The mechanistic and morphological origins of microscopic wear debris generated from UHMWPE articular surfaces in total joint replacement prostheses are investigated in this study. It was found experimentally that the molecular chain structure at the articulating surface of UHMWPE undergoes a re-organization process due to strain accumulation caused by surface traction. This molecular re-organization process creates a fibre-like surface texture that exhibits an anisotropic behaviour similar to a unidirectionally reinforced polymer composite. This composite responds to stresses favourably if loaded along the fibre axis but unfavourably if loaded off axis. Due to the very complex multi-axial motion/loading nature at the articular surfaces in total joint replacements, the stress tensors applied to each localized asperity contact area continuously change their directions and magnitudes. These changes in the localized stress field create an off-axis loading situation at each localized contact zone with respect to the orientation of the molecular chains. Depending on the off-axis angle, failure of the molecular structure occurs in three different ways: tensile rupture at very small off-axis angles, shear rupture at intermediate off-axis angles and transverse splitting at large off-axis angles. These failure mechanisms all produce similar fibre-like wear debris. However, the failure stresses differ significantly among the three modes. According to this molecular wear theory, the preferred polymer microstructure for optimal wear resistance would be a three-dimensionally strong network connected by covalent bonds between molecular chains. For UHMWPE, a three-dimensional molecular network can be created by radiation induced cross-linking. Experiments conducted on both gamma irradiated and unirradiated UHMWPE specimens using a linear wear machine and multi-axial joint simulators confirmed the validity of the molecular wear theory.

Biocompatible Materials↗

Role of cyclic plastic deformation in the wear of UHMWPE acetabular cups.

The mechanisms of wear in ultra-high-molecular-weight polyethylene (UHMWPE) acetabular cups were investigated on both laboratory simulator-tested cups and a clinically retrieved component. Two different levels of wear process were identified: one characterized by the formation and detachment of platelet-like flakes from initial machining marks, and the other by the formation of fine ripple and fibrils by repeated passes of microscopic asperities on the femoral head. Both wear processes could be described by a criterion of critical plastic strain. A theoretical model was developed to account for the generation of the microscopic wear particles based on such a critical strain criterion. Its predictions of the dependence of the UHMWPE wear rate on surface roughness and applied load were in excellent agreement with previously published experimental correlations.

Acetabulum↗

The use of short carbon fibre reinforced thermoplastic plates for fracture fixation.

Thermoplastic plates of Nylon 6-10 and Polybutylene terephthalate reinforced with 30% short randomly oriented carbon fibres were tested for internal fixation of canine femoral transverse midshaft fractures. The elastic modulus of the plates was one-half that of bone: however, ultimate strength and strain in bending were comparable to bone. The fractures healed with moderate callus formation which was completely remodelled by 8 to 12 wk post surgery. Although a moderate inflammatory reaction to occasional particulate debris was noted, the materials appeared to possess the proper elastic moduli to allow sufficient support for the healing fracture without protecting the remodelling process.

Animals↗

Elements of hip joint prosthesis reliability.

The performance of a total hip prosthesis is considered in terms of reliability. The causes requiring removal of the prosthesis are considered and methods of avoiding these difficulties are outlined. It is pointed out that most attention must be focused on the areas of low reliability. The goal of increasing prosthesis lifetime must be shared between the surgeon and manufacturer.