PubMed Health⌕ Search

Biomedical subjects

J H Grunert

Publications and source records attributed to J H Grunert.

18 recordsLinked to original sources

DIMA enlargement mammography in microcalcifications: a prospective study with ROC analysis.

The purpose of this study was to investigate whether the four-fold magnification mammography (direct magnification, DIMA) technique would perform better than conventional 1.5-fold magnification mammography in the differentiation of breast microcalcifications into benign and malignant. Fifty patients with non-palpable microcalcifications detected by mammography were examined immediately prior to surgical biopsy using both a conventional (1.5-fold) and the DIMA (fourfold) magnification mammography techniques. The microcalcifications were classified by five experienced radiologists using morphological criteria. A receiver operating characteristics curve (ROC) analysis of the sensitivity and specificity of both techniques in assessing malignancy was then carried out. The DIMA mammography technique was slightly but non-significantly superior to the conventional method in detecting malignancy (p > 0.05). Coarse granular and pleomorphic calcifications were detected more frequently with the DIMA technique. Coarse calcifications were significantly more frequently associated with histologically benign findings, whereas fine granular calcifications were significantly more likely to be malignant lesions. Assessment of malignancy associated with microcalcifications using morphological criteria is not significantly improved by mammography techniques with higher magnification.

Biopsy↗

[Radiographic image magnification as quality control of microcalcification imaging within the scope of histopathological control of breast biopsy tissue].

PURPOSE: Evaluation of specimen radiography as a quality control for the detection of microcalcifications by the pathologist during histopathological examination of breast biopsies. MATERIALS AND METHODS: 29 breast biopsy specimen with microcalcifications were radiographed using the magnification (x4) mammography System DIMA Plus MI I before and after the histopathological examination. Tissue with detected microcalcifications after the histopathological examination was reexamined histologically. RESULTS: In 55% (16/29) of all specimen we could identify missed microcalcifications. In 5 specimens the microcalcifications were missed completely. The radiologically detected areas of residual microcalcifications were reexamined histologically and in one case invasive parts of a carcinoma were detected, which primarily had been diagnosed as an in-situ carcinoma. In 6 cases the radiographs of the intraoperative specimen radiography were sent to the pathologist together with the biopsy. In these cases the rate of complete detection of the microcalcifications increased from 39% to 66%. CONCLUSION: Specimen radiography should be performed not only intraoperatively but also as part of the histopathological examination.

Biopsy, Needle↗

Grids and high kilo-volt-peak-setting in bedside chest radiographic examinations.

Bedside chest radiographic examinations in intensive care units with grids are impaired by artefacts caused by angulation of the grid (grid cut-off). Two different grids--a grid with a high strip density of 70 lines per cm and the "InSight portable imaging system"--were examined in an intensive care unit with respect to their susceptibility to angulation, image quality and handling of the grid. Five radiologists compared 50 radiographs of each grid considering ten image quality criteria. Using the "InSight portable imaging system" major artefacts were undetectable even at an angulation of 10%; no adjustment of the grid was required, which reduced the amount of time needed to take the radiograph by 26%. The increase in dosage demanded by the employment of the grids at low kilovolt peak setting could be partially compensated by the use of high kilovolt peak setting. The image quality of the "InSight portable imaging system" together with a high kilovolt peak setting is satisfactory, and due to its simplified handling, the portable imaging system has proved to be suitable for bedside chest radiography in intensive care.

Artifacts↗

[Detection of microcalcifications in breast specimens by 4-fold DIMA direct magnification radiography compared to 1.5-fold conventional magnification radiography].

AIMS OF STUDY: The purpose of this study was to investigate the efficacy of 4-fold magnification breast specimen radiography (direct magnification, DIMA) compared to conventional 1.5-fold magnification radiography in evaluating the presence or absence of carcinoma at the surgical margins by detection of microcalcification. METHODS: Fifty breast specimens with non-palpable microcalcifications were examined during surgical biopsy using both DIMA (4-fold) and conventional (1.5-fold) magnification specimen radiography. The number of detected microcalcifications of the whole specimen, of an area of 5 mm distance to the margins and of the area of the suspicious cluster of microcalcifications was counted and the results compared with the histological examination as a gold standard. RESULTS: In 50 specimen 2821 (1305 within 3 mm distance to the margins) microcalcifications were detected with the DIMA mammography technique compared to 1608 (446) microcalcifications with the conventional technique. This increased detection rate by DIMA-magnification radiography was accompanied by a decreased specificity in comparison to the conventional magnification radiography (33.3% DIMA versus 83.3% conventional) regarding the evaluation of presence or absence of carcinoma at the surgical margins. Differentiating the microcalcifications into calcifications belonging to the suspicious cluster and those that are located outside the cluster led to an increase in specificity (83.3% DIMA versus 100% conventional). CONCLUSIONS: The efficacy of breast specimen radiography in evaluating the presence or absence of carcinoma at the surgical margins by detection of microcalcification is not improved by 4-fold magnification radiography (direct magnification, DIMA) compared to conventional 1.5-fold magnification radiography due to an increase in false-positive results. Analysis of the attachment of the microcalcifications to the cluster can improve the specificity.

Biopsy↗

[The demonstration of microcalcification in breast core biopsies: DIMA specimen radiography (7x) compared to the histopathological findings].

PURPOSE: Comparing the sensitivity in detecting microcalcifications in stereotactically guided core biopsy specimen of the breast of direct magnification (DIMA) specimen radiography (x7) with the histological examination. MATERIALS AND METHODS: In 52 patients 509 stereotactically obtained core biopsy (14-gauge) specimens of the breast were radiographed by direct magnification (DIMA) specimen radiography (x7) and examined histologically. RESULTS: In 188 specimen microcalcifications were detected by magnification radiography compared to 98 by histological examination. Only 3% of the specimen microcalcifications were seen exclusively in the histological examination. In core biopsies with malignancy the relative proportion of biopsies with radiologically detected microcalcifications was increased (59% versus 32%). CONCLUSION: Concerning the detection of microcalcifications in core biopsy specimen of the breast, the direct magnification (DIMA) radiography (x7) was superior compared to the histological examination. Due to the high relative proportion of biopsies with radiologically detected microcalcification and malignancy, we recommend a comprehensive histological examination of these specimen. Confirmation of microcalcifications in core biopsies should be achieved by magnification radiography to prove that the suspicious area in the breast was truly sampled. Specimen radiography simultaneously with the biopsy procedure can reduce the number of punctures in the process of documenting the presence of calcifications early in the biopsy procedure.

Biopsy↗

[Value of Doppler color ultrasonography in diagnosis of arterial occlusive disease of the lower extremity. A direct comparison with percutaneous angiography].

UNLABELLED: A Direct Comparison with Percutaneous Angiography: AIM: To compare colour-coded Doppler sonography (CCDS) with conventional angiography in severe occlusive vascular disease of the lower limb. METHODS: In 55 patients 1141 vessel segments were evaluated, 700 of them with atheromatous plaques, 270 with stenoses, 208 with occlusions and 6 with aneurysms. RESULTS: Deeper-seated vessels such as the abdominal aorta, the pelvic arteries, the superficial femoral artery at the level of the adductor canal and parts of the lower leg arteries are less accessible for direct CCDS. Many pathological changes however can be diagnosed indirectly by changes in the spectral wave form distal to the lesion. In superficial vascular segments (the common femoral artery, the profunda femoris artery, the superficial femoral artery above the adductor canal and the popliteal artery) image quality was excellent, more pathological changes were found, and the degree of stenosis was better estimated in comparison to angiography. CONCLUSION: The value of CCDS in patients with intermittent claudication is limited to those who have been examined with angiography e.g. before angioplasty, to follow-up examinations after vascular dilatation or surgery and to supplementary visualisation after angiography especially in readily accessible (superficial) vascular segments.

Adult↗

[The value of color Doppler ultrasound in follow-up of percutaneous transluminal angioplasty of the thigh area].

The value of colour-coded Doppler sonography to evaluate results of percutaneous transluminal angioplasty of the superficial femoral artery was tested in 26 patients. Because of good accessibility, morphology may be demonstrated similar to intravenous DSA. However, accurate evaluation of dilatation success also requires haemodynamic measurements. Numerous parameters were determined one day before, one day after and one month after angioplasty at various points of the extremity (dilated segment, popliteal artery, lower leg arteries). Results were compared with those of normal individuals. Because of the large range of scatter and overlapping between normal and pathological values, only a few parameters can be used as valuable indicators for successful PTA. Spectral wave form becomes bi- or triphasic pattern and due to this the Pulsatility Index rises distal to the dilated area. An increasing systolic acceleration rate, peak systolic velocity and prestenotic Pulsatility Index have excellent predictive value. Using a Damping Factor, the later walking range may be predicted.

Adult↗

Long-term survival after embolization of potentially lethal bleeding malignant pelvic tumours.

Transcatheter embolization was performed in 45 patients suffering from potentially lethal bleeding originating from malignant tumours in the pelvic region. In 21 cases, the basic disease was rectosigmoidal and in 20, gynaecological in origin. Uncommon bleeding sites were embolized in four other cases. The median survival time (Kaplan-Meier) was 6 months. Most patients died from tumour cachexia. In 10 cases (22%), recurrent bleeding occurred, in three of these with lethal consequences. Successful reembolization was performed on seven patients. The different embolization materials used showed a minor impact on the therapeutic result. Embolization therapy proved to be an effective measure in potentially lethal malignant pelvic bleeding. Gianturco, Anderson and Wallace (GAW) coils should be given preference where there is urgency, as they are accurate, easily and quickly insertable, and cause few complications.

Adult↗

[Use of multi-grid screens in intensive care units].

Bedside chest radiographic examinations in intensive care units with grids and high kilovoltage-peak settings are impaired by artifacts caused by the angulation of the grid (grid cutoff). We have tried to optimize the use of grids in bedside chest radiographic examinations. The sensitivity to the effect of grid cutoff was examined in two grids with the same grid ratio (12:1) but different numbers of lamelle per cm (40 versus 70) using a water-phantom. The alignment of the grid in a bedside setting was optimised. 100 chest examinations in the intensive care unit were compared by five radiologists according to ten criteria. Grids with a high number of lamelle per cm (70) proved to be less sensitive to the effects of grid cutoff. By positioning the grid with the lamelle vertical to patient's body-axis, asymmetric exposure of the lungs could be avoided. In addition, this setting allows an easy alignment of the grid by adjusting the grid together with the moveable part of the patient's bed. In examinations with grids, the advantages of high kilovoltage-peak setting were apparent. Bedside radiographic examinations in intensive care units with grids with a high number of lamelle and high-kilovoltage-peak setting can be performed without any major additional effort. By this method the image quality can be improved, especially in lungs with increased scatter-radiation.

Artifacts↗

[Left internal thoracic artery as a collateral vessel in chronic occlusion of the pelvic artery].

Four years after implantation of an aorto-bi-iliac artery graft, a 53-year-old man suffered from intermittent claudication with a walking distance of 50 meters. By transaxillary aortography the left femoral artery could not be visualized. Selective angiography of the internal thoracic artery revealed a collateral circulation from the subclavian artery via the left internal thoracic artery, the superior epigastric artery and the inferior epigastric artery into the left external iliac artery (Winslow's pathway). Prior to using the internal thoracic artery for coronary bypass surgery, a function of this vessel as a collateral to the lower extremities should be excluded.

Aorta, Abdominal↗

[The diagnosis of lymphatic vascular dysplasia and lymphatic fistula formation].

The importance of lymphangiography for diagnosing the formation of lymphatic fistulas and vascular dysplasias of the lymphatic vessels is on the increase within the scope of therapeutic invasiveness. Its importance and ranking in diagnosing lymphatic circular disorders is demonstrated and exemplified by case reports on three patients suffering from chylothorax of various origin, on one patient with chyluria, and one patient with lymphoedema in the soft parts of the neck. In two chylothorax patients, lymphangiography resulted in successful surgery. It is the decisive method in diagnosis and therapy planning in fistulas and dysplasias of the lymphatic vessel system.

Adult↗

Objective identification of hyperactivated human spermatozoa by computerized sperm motion analysis with the Hamilton-Thorn sperm motility analyser.

Sperm from 10 fertile donors were incubated for 8 h in a capacitating medium (BWW 3.5% HSA) and treated with 1.25 microliters of 2 mM Ca-ionophore solution. Sperm motion was analysed using the Hamilton-Thorn system before and after incubation and treatment. The acrosome reaction was detected with PSA-FITC labelling of the acrosome. Critical values of sperm movement parameters were defined for objective identification of hyperactive movement by the Hamilton-Thorn system. The incidence of hyperactive movement in the sperm suspensions was approximately 2%. No significant changes of hyperactive movement could be observed after the incubation period or the ionophore treatment, in contrast to a significant rise in the percentage of acrosome-reacted cells after ionophore treatment. The implications of these findings for monitoring hyperactive cells to test sperm function are discussed.

Acrosome↗

Does computerized image analysis of sperm movement enhance the predictive value of semen analysis for in-vitro fertilization results?

The influence of semen quality on fertilization rates in an in-vitro fertilization (IVF) programme was studied by analysing both conventional semen parameters and computerized movement characteristics. The study was based on 407 inseminated oocytes which were obtained from 50 patients in 113 laparoscopies. Sperm concentration did not correlate strongly with the fertilization rate. Sperm motility and morphology were the most meaningful parameters in predicting fertilization success. A drop in fertilization rate was found when sperm motility or normal morphology were below 40%. Sperm velocity measured in semen was the only sperm movement parameter which correlated with the fertilization rate, albeit weakly. The latter was reduced when average sperm velocity in semen was less than 50 microns/sec. Conventional semen parameters seem to be more predictive of the fertilizing potential of an ejaculate than movement characteristics obtained by computerized image analysis.

Fertilization↗

Human and bovine cervical mucus penetration as a test of sperm function for in-vitro fertilization.

Human and bovine cervical mucus penetration tests (n = 57) were performed preceding IVF to test their prognostic value as sperm function tests for IVF. This evaluation also included results from conventional semen analysis and from a computerized sperm analysis system. The bovine cervical mucus penetration test was shown to be at least as valuable as the human cervical mucus penetration test in evaluating sperm function. The migration distance of the vanguard sperm (P less than 0.001) and the sperm density at a fixed migration distance in the mucus column (P less than 0.05) correlated most closely with the IVF results. A clear parallelism with the outcome of the 'swim up' technique was also found. Of the sperm parameters examined, only sperm motility in the ejaculate (P less than 0.05) correlated significantly with the results of IVF. It is concluded that the outcome of a bovine cervical mucus penetration test depends on the same sperm functions as required for IVF. Therefore, this test may be of predictive value in an IVF programme.

Animals↗

Endotoxemia in intensive care patients: a longitudinal study with the limulus amebocyte lysate test.

In patients with severe underlying disease and in polytraumatized patients, clinical signs of septicemia caused by infections with gram-negative bacteria are observed postoperatively with increasing frequency. Using a photometric LAL test, a longitudinal assessment of LAL reactivity on 41 intensive care patients was performed. Postoperatively, all patients developed a septicemia of different severity with body temperatures greater than 38.5 degrees C. Dividing the individual disease course, related to body temperatures, into three phases (A-C) it was found that independent of the severity of septicemia, the majority of patients (38/41) yielded a positive LAL reactivity. In phase B (body temperature greater than 38.5 degrees C) more plasma samples contained LAL-reactive material than in phase A and C (body temperature less than 38.5 degrees C). A decline of fever (phase B to C) correlated significantly (P less than 0.05) with the change from positive to negative LAL reactivity. In patients with high leukocyte counts (15-50 X 10(9)/l) a positive LAL reactivity was found more frequently. The majority of patients (21/27) who survived were transferred with negative LAL reactivity to the general wards. The results suggest that single determinations of LAL reactivity are of limited clinical validity. Using the individual profile of LAL reactivity gained through a longitudinal assessment, data upon the development of the disease course can be obtained.

Adult↗

Access-related venous stenoses and occlusions: treatment with percutaneous transluminal angioplasty and Dacron-covered stents.

PURPOSE: To determine the effectiveness of using Dacron-covered stents to treat access-related venous stenoses and occlusions. METHODS: Twenty-two Dacron-covered stents were placed in 20 patients: in the basilic or axillary vein (n = 2), cephalic vein (n = 3), subclavian vein (n = 5), and at the venous anastomosis of the polytetrafluoroethylene (PTFE) implant graft (n = 10). RESULTS: Initial technical success was 100%. The cumulative primary and secondary patency rates were 57% and 83% at 6 months, 29% and 64% at 12 months, and 29% and 53% at 18 months. A statistically significant difference in the stent patency was revealed by comparing the patients with stents in the subclavian vein and patients with upper arm stents. The secondary patency rates of the upper arm stents were 73% after 6, 12, and 18 months. CONCLUSIONS: Percutaneous placement of Dacron-covered stents is a safe and effective procedure for salvage of a dialysis fistula. First results are promising, with a tendency to prolongation of the time interval between reinterventions.

Angioplasty, Balloon↗

Diagnostic value of scrotal sonography in infertile men: report on 658 cases.

Scrotal sonography with a 7.5 MHz sector scanner was performed on 658 consecutive patients of our infertility clinic. The incidence of pathological findings was unexpectedly high. Forty per cent of the patients revealed pathological structures such as varicoceles (21%), hydroceles (7%), epididymal abnormalities (6%), spermatoceles (6%), intratesticular hyper- and hypoechoic changes (4.5%), intratesticular cysts (1%) and tumours or carcinoma in situ (CIS) (0.6%). Sonographic evaluation and measurement of the caput epididymidis was compared with palpation. Sonography distinguished size ranges of "normal" and "thickened" epididymides as diagnosed by palpation. Cystic structures were proven in 56% of cases with "thickened" epididymides. The sonographically determined diameters of doppler-negative blood vessels were significantly smaller than those of doppler-positive vessels. Sonography revealed a higher occurrence of varicoceles than diagnosed by palpation (76% by palpation). Only 58% of sonographically identified hydroceles and only 67% of sonographically detected spermatoceles were detected by palpation. One testicular tumour and one case with CIS were only seen by sonography and not suspected on palpation. The results demonstrate that sonography represents a valuable tool in the routine diagnosis of andrological patients.

Adult↗