PubMed Health⌕ Search

Biomedical subjects

J H Linehan

Publications and source records attributed to J H Linehan.

At least 55 records · Page 3Linked to original sources

Effect of atelectasis and surface tension on pulmonary vascular compliance.

The effects of atelectasis and surface tension on the vascular volume and compliance in an isolated perfused dog lung lobe were studied using vascular occlusion and indicator-dilution methods. Measurements were made during atelectasis and again after the lobes were inflated with either a gas mixture (air) or 0.9% saline. Inflation with air resulted in a 20% increase in vascular volume (P less than 0.02), whereas saline inflation had no effect on vascular volume. Inflation with either air or saline increased static vascular compliance by approximately 58% (P less than 0.001) and dynamic vascular compliance by approximately 85% (P less than 0.001). The larger dynamic compliance in the inflated lobes appears to have been mainly due to a larger microvascular compliance. The results suggest that atelectasis can result in a stiffer pulmonary capillary bed. This effect appears to be due primarily to the reconfiguration of the lung tissue structure, because replacing the air with an incompressible fluid did not have the same effect.

Animals↗

Distensibility of small arteries of the dog lung.

To obtain in situ measurements of the distensibility of small (100- to 1,000-microns-diam) pulmonary arterial vessels of the dog lung, X-ray angiograms were obtained from isolated lung lobes with the vascular pressure adjusted to various levels. The in situ diameter-pressure relationships were compared with the diameter-pressure relationships for small arteries that were dissected free from the lungs and cannulated with small glass pipettes for the measurement of diameter and transmural pressure. The diameter-vascular or diameter-transmural pressure curves from both in situ and cannulated vessels were sufficiently linear in the pressure range studied (0-30 Torr) that they could be characterized by linear regression to obtain estimates of D0, the diameter at zero vascular pressure, and beta, the change in diameter (micron) per Torr change in pressure. The vessel distensibility coefficient (alpha) was defined as alpha = beta/D0. The mean values of alpha were approximately 2.0 +/- 0.8%/Torr (SD) for the in situ vessels and 1.7 +/- 0.6%/Torr for the cannulated vessels, with no statistically significant difference between the two methods. The influence of vasoconstriction elicited by serotonin was evaluated in the in situ vessels. Serotonin-induced vasoconstriction caused a decrease in D0 and little change in alpha.

Animals↗

An algorithm for angiographic estimation of blood vessel diameter.

This study was carried out in an attempt to develop an objective and robust method for measuring changes in the diameters of small blood vessels from X-ray angiographic images. Recognizing potential problems with edge detection methods applied to cylindrical vessels in which the contrast diminishes as the boundary is approached, we have attempted to utilize the X-ray absorbance data across the entire cross section of the vessel. Then, assuming a cylindrical geometry, the absorbance data are fit to the cylindrical absorbance function by use of nonlinear regression analysis. The method was tested and calibrated using glass tubes filled with various concentrations of contrast medium. The diameters of small pulmonary arteries were estimated by applying the method of angiograms obtained from an isolated dog lung lobe. The structure of the residuals obtained after the fitting procedure was analyzed to test the appropriateness of the model for use with images of vessels. The results suggest that this approach will have utility for systematically quantifying vessel dimensions.

Algorithms↗

Lung angiotensin-converting enzyme kinetics from indicator-dilution and constant-infusion methods.

We compared the results of three methods used to evaluate the kinetics of benzoyl-phenylalanyl-alanyl-proline (BPAP) hydrolysis by angiotensin-converting enzyme in the isolated rabbit lung. In method A, the arteriovenous concentration differences at each of four rates of BPAP infusion were used to determine the effect of concentration on the rate of BPAP hydrolysis. In methods B1 and B2, trace doses of [3H]BPAP were injected during each constant infusion of unlabeled BPAP so that the venous [3H]BPAP concentration could be used to estimate the venous BPAP concentration and the rate of hydrolysis at each background concentration. In method C, three boluses containing different amounts of unlabeled BPAP as well as tracer [3H]BPAP were injected such that each bolus resulted in a range of concentrations and hydrolysis rates that could be estimated from the venous concentrations of [3H]BPAP. Each method provided the data needed to calculate the maximum uptake rate (Vmax) and Km, the concentration at half Vmax, assuming that the hydrolysis can be represented by the Michaelis-Menten equation. However, the mathematical model underlying each method involved different assumptions about the effects of heterogeneity of capillary transit times and bolus dispersion. The mean values of Vmax were 180, 216, 217, and 200 nmol/s and for Km 7.8, 10.4, 8.6, and 10.0 microM for methods A, B1, B2, and C, respectively. The differences between methods were not statistically significant. These results suggest that theoretical differences between the methods did not have a quantitatively important impact relative to other factors contributing random errors to each of the methods. The choice between methods can therefore be made on practical grounds.

Animals↗

Effect of transit time on metabolism of a pulmonary endothelial enzyme substrate.

Fractional hydrolysis (M) of the synthetic angiotensin-converting enzyme (ACE) substrate [3H]benzoyl-Phe-Ala-Pro (BPAP) on passage through the isolated dog lung lobe was found to be relatively independent of flow rate and transit time (t). The most commonly expressed explanation for this kind of observation is that recruitment of ACE-containing surface area occurs when flow is increased. To test this, as well as other hypotheses that might explain the behavior of this substrate, we compared M obtained after the first pass of a BPAP-containing bolus through isolated rabbit lungs with that obtained after two sequential passes through the lungs. In this way, we could double t with no change in flow or vascular pressure. We found that, when the second pass occurred within a few seconds of the first, M after both the first and second pass was only slightly larger than that after the first pass alone. If the time between passes was increased to a few minutes, M after the second pass was substantially increased. These results are contrary to the recruitment hypothesis and suggest that this substrate may exist in alternative forms that are in slow equilibrium relative to the capillary t. When albumin was present in the perfusate, an albumin-bound fraction appeared to be one such alternative form. However, experiments carried out using protein-free perfusate suggest the possibility that conformational variants of the substrate may also exist.

Animals↗

Hydrolysis of a synthetic angiotensin-converting enzyme substrate in dog lungs.

The present study was carried out to begin to evaluate the saturable kinetics of the hydrolysis of a synthetic substrate, benzoyl-phenylalanyl-alanyl-proline (BPAP), for angiotensin-converting enzyme (ACE), by the pulmonary endothelium of the dog using a multiple indicator dilution method. In the experiments, isolated dog lung lobes were perfused with a salt solution containing 5% bovine serum albumin. Boluses containing [3H]BPAP, and various amounts of unlabeled BPAP were injected into the lobar artery, and timed samples of venous effluent were collected. The samples were analyzed to determine the fractional hydrolysis of the injected BPAP. The BPAP hydrolysis on passage through the lungs exhibited the saturable behavior and the relative insensitivity to changing flow rate previously described. Since we have described previously that BPAP behaves as if it exists in two forms, one of which is virtually unhydrolyzable on a single pass through the lungs, a model was formulated to include the influence of the unhydrolyzable form, as well as the saturable hydrolysis of the hydrolyzable form, on the fractional hydrolysis of the injected BPAP. This model provides a new method for estimating the kinetic parameters of BPAP hydrolysis by pulmonary endothelial ACE, and it explains the observation that the fractional BPAP hydrolysis does not vary with flow rate and transit time to the extent predicted by previous models.

Animals↗

Kinetics of serotonin uptake in isolated rabbit lungs.

The single-pass, bolus-injection method was used to study the effect of serotonin (5-HT) concentration on the extraction of 5-HT by isolated perfused rabbit lungs. The extraction pattern suggested that an uptake model, which includes multiple parallel uptake processes, provided a better representation of the data than the simple Michaelis-Menten equation, which has commonly been used to fit the saturable uptake data in previous studies. In particular, the rabbit lung data could be fit with two such parallel pathways. Since the 5-HT uptake could virtually be completely blocked by imipramine, both pathways can be considered to be carrier-mediated processes. The high-affinity pathway was saturable within the range of concentrations studied, with a Km and Vmax of approximately 0.84 microM and 0.21 nmol.s-1.g wet lung wt-1. The Km for the low-affinity pathway was larger than concentrations for which accurate uptake measurements are practical in the perfused organ. Thus, for the low-affinity pathway, only Vmax/Km was identifiable. Vmax/Km values for the high- and low-affinity pathways were approximately 2.87 and 0.35 ml/s, respectively. The results suggest that it will be worthwhile to investigate the behavior of these uptake parameters in response to changes in lung physiology and endothelial function in future studies.

Animals↗

Plasma protein binding and endothelial enzyme interactions in the lung.

The influence of plasma albumin binding of the synthetic angiotensin-converting enzyme (ACE) substrate [3H]benzoyl-phenylalanyl-alanyl-proline (BPAP) on BPAP hydrolysis by pulmonary endothelial ACE was studied in isolated rabbit lungs perfused with a salt solution containing either 5% bovine serum albumin (BSA) or 5% dextran. The single-pass indicator-dilution method was used to measure the fraction (M) of [3H]BPAP hydrolyzed. Lung M was greater with albumin-free perfusate than when BSA was present. M decreased as the time (ti) that the BPAP was in contact with the BSA before reaching the lung was increased, suggesting that some BSA binding sites for BPAP were not in equilibrium during bolus transit through the lungs. The M vs. ti data were correlated using a model incorporating both rapid and slow binding kinetics of BPAP and BSA. For the slow BPAP-BSA interaction, the dissociation rate constant was approximately 0.015 s-1, and the fraction of the BPAP bound to these slowly equilibrating sites at equilibrium was approximately 22%. The results indicate that transient plasma protein binding kinetics can affect lung BPAP hydrolysis.

Animals↗

Influence of size of emboli on extravascular lung water.

We examined the influence of the size of emboli on the vascular volume (QL) and extravascular volume (Qev) accessible to 3HOH during a single pass through an isolated dog lung lobe using the double indicator-dilution method with 125I-human serum albumin as the vascular indicator. As successively more beads of a given diameter (58, 548, or 3,175 microns) were introduced into a lung lobe, a linear relationship between QL and Qev was obtained as they both decreased. The slope of the graph of QL vs. Qev with progressive embolism was directly proportional to the bead diameter. This suggested an approach for estimating the total vascular volume in vessels smaller than the diameter of the beads before embolization, referred to as Qm. If it is assumed that most of the transvascular diffusional exchange of 3HOH occurs in vessels smaller than the smallest beads (mainly capillaries) and that vessel obstruction does not change the ratio of Qev to the perfused capillary volume, the slope of the plot of QL vs. Qev is an estimate of the fraction, Qm/QL, of the total vascular volume in vessels smaller than the bead diameter. In the dog lung lobes studied, Qm/QL was approximately 0.64 for 58-microns vessels, 0.75 for 548-microns vessels, and 0.82 for 3,175-microns vessels. The results suggest that, with occlusion of vessels greater than or equal to 58 microns, 3HOH does not diffuse significantly into unperfused regions.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Fate of air emboli in the pulmonary circulation.

The lung serves an important nonrespiratory function by trapping and excreting venous air emboli. The site of trapping and the mechanism of excretion, however, are uncertain. To observe the behavior of bubbles in the pulmonary circulation, we injected venous air emboli into anesthetized dogs and videotaped their elimination from the pulmonary microcirculation by using in vivo microscopy. Small intravenous bubbles lodged exclusively in pulmonary arterioles and were eliminated from that site. To determine whether the gas was dissolving into nearby blood and then was carried to the capillaries for excretion, the rate of bubble radius change was measured during nonperfused conditions produced by balloon occlusion of lobar blood flow and compared with perfused conditions. Bubble volume decreased at the same rate during perfused and nonperfused conditions and thus was independent of regional blood flow. Molecular diffusion of gas directly across the arteriolar wall into alveolar spaces was the most likely mechanism of elimination because calculations based on the Fick equation for molecular diffusion predict an elimination rate nearly identical with those observed experimentally.

Animals↗

On the estimation of pulmonary capillary pressure from arterial occlusion.

We have attempted to evaluate some approaches for estimating pulmonary capillary pressure from the transient pressure data obtained from the tip of the Swanz-Ganz catheter after inflation of the balloon. To this end experiments were carried out in anesthetized dogs in which pulmonary vasoconstriction was induced by infusion of histamine, serotonin, or norepinephrine or by hypoxia. In a group of closed chest dogs, the time course for the fall in the catheter tip pressure toward the wedge pressure was different for the different vasoconstrictors. For example, during histamine infusion the fall in pressure was slow, whereas during serotonin infusion it was rapid. To evaluate the information in the decay curves, a group of dogs was studied with open thorax to permit the simultaneous occlusion of both the artery and vein of one lung lobe (double occlusion) as well as occlusion of the lobar artery alone (arterial occlusion). The pattern of response to the various vasoconstrictors observed with lobar arterial occlusion was similar in these animals to the closed chest animals. The equilibrium pressure after double occlusion (the double occlusion pressure), expressed as a fraction of the mean arterial-venous pressure difference before occlusion, was correlated with the mean decay time of the arterial pressure curve after arterial occlusion. We also found significant correlations between the double occlusion pressure and the estimates of capillary pressure based on model interpretations of the pressure decay curve after arterial occlusion. However, there was wide scatter in the individual comparisons.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Evaluation of endothelial injury in the human lung.

The pulmonary endothelium plays a crucial role in the normal function of the lungs. Damage to the pulmonary endothelium is thought to be a primary event leading to deficits in pulmonary function in diverse forms of lung injury, but it is difficult to detect until these secondary deficits are manifest. Indicator dilution methods are practical for evaluation of endothelial function in patients. Interpretation of the information contained in the data is potentially complex, and specificity may be improved by using multiple indicators, each of which interacts with the endothelium in a different way. The general clinical utility of the methods is not yet established. However, encouraging experimental results, clinical studies, and improved technologies suggest that the methods have the potential to be of significant diagnostic and prognostic value.

Capillary Permeability↗

Distributions of vascular volume and compliance in the lung.

The ether- and dye-dilution methods were used to estimate the arterial, capillary, and venous volumes and compliances in isolated dog lung lobes. In the range of arterial pressure from approximately 7 to 14.5 Torr and venous pressure of 1.4 to 10.8 Torr, the total lobar blood volume ranged from approximately 2 to approximately 2.6 ml/kg body wt. About 19% of the lobar vascular volume was in the arteries, approximately 59% was in the capillaries, and approximately 22% was in the veins. The lobar vascular compliance was approximately 0.065 ml.Torr-1.kg body wt-1 with an arterial-capillary-venous distribution of approximately 30:49:21. These results suggest that the largest fractions of the intralobar blood volume and compliance are in the capillary bed. The segmental compliances along with outflow occlusion data were used to place lower and upper bounds on the arterial, capillary, and venous resistances. These bounds were 13.6 and 61.4% of the total vascular resistance for the arteries, 0 and 59.4% for the capillaries, and 5.5 and 64.9% for the veins, respectively. These bounds are rather broad, but they help to put the information content of the occlusion data under the conditions of these experiments into perspective.

Animals↗

Distributions of vascular pressure and resistance in the lung.

The low-viscosity bolus method was used to determine the longitudinal distributions of vascular resistance and intravascular pressure with respect to cumulative vascular volume from the lobar artery to the lobar vein in isolated dog lung lobes near functional residual capacity under zone 3 conditions. We found that the resistance distribution had two modes, a larger one upstream and a smaller one downstream from a local minimum. Over the range of vascular pressures studied the total vascular resistance decreased and the vascular volume increased with increasing vascular pressure. However, the shape of the normalized resistance distribution was independent of vascular pressure. Comparisons of the resistance distributions with the distributions of arterial, capillary, and venous volumes suggest that the modes represent regions of relatively high resistance proximal and distal to the capillary bed. These results are consistent with the concept that within the lobar vascular bed the highest resistance per unit blood volume is in the smallest arteries and veins, as suggested by morphometric data from other sources.

Animals↗

Kinetics of uptake and metabolism by endothelial cell from indicator dilution data.

Certain substrates are rapidly taken up and/or metabolized by pulmonary endothelial cells in a saturable process. When such a substrate and a reference indicator are included in a bolus which is injected into the blood flowing into the lung, the extraction ratio, E(t), curves measured in the pulmonary venous outflow are asymmetric with respect to the reference indicator curve. If a sufficient quantity of substrate is included in the bolus, the extraction curves are concave upward. The shapes of the E(t) curves contain information regarding the chemical-physical processes which govern the fate of the substrate during its single passage through the lung. To interpret the shapes, computer simulations are used to illustrate separately the effects of the uptake of substrate into the cell, the returning flux of the substrate from the cell, the saturation phenomena of the extraction process, and the perfusion heterogeneity of the capillaries. Lastly, a simple analytical method for estimating the organ kinetic parameters of the extraction process is presented.

Animals↗

Kinetics of serotonin uptake in the intact lung.

The pulmonary endothelium is capable of removing and metabolizing serotonin (5HT) carried in the venous blood. Thus the lungs can influence the arterial concentrations of 5HT. In addition, there is evidence that changes in the lung uptake of 5HT might portend more serious endothelial damage wherein the barrier function of the endothelium is compromised. This has been a stimulus for finding methods for evaluating these endothelial functions. These methods must be able to distinguish changes in whole organ function which result from changes in perfusion (e.g., cardiac output, redistribution of flow, etc.) from those resulting from changes in the function of the endothelial cells. When a bolus containing radio-labeled 5HT and an unmetabolizable indicator which is confined to the vascular space is injected into the pulmonary artery, the pulmonary venous or systemic arterial concentration curves contain information about both the convective transport and endothelial cell process involved. Some of this information can be interpreted quantitatively using a simple mathematical model.

Animals↗

Effects of gas composition and pH on kinetics of lung angiotensin-converting enzyme.

Given the pH dependence of enzymes in general and the potential importance of a blood and alveolar gas composition dependency on the interpretation of changes in the hydrolysis of angiotensin-converting enzyme (ACE) substrates by pulmonary endothelial ACE, we examined the influence of Pco2 and Po2 on the hydrolysis of a synthetic ACE substrate (benzoyl-phenylalanyl-alanyl-proline, BPAP) on passage through isolated rabbit lungs. Perfusate pH values of about 7.1, 7.4, and 7.9 were obtained by ventilating the lungs with gas containing different CO2 concentrations and Po2 values of approximately 110 and approximately 10 Torr were obtained by varying the concentration of O2 in the ventilating gas mixture. In the range studied neither acidosis nor alkalosis produced any significant changes in BPAP hydrolysis or in the kinetic parameters, Vmax and Km, for the hydrolysis process. On the other hand, a reduction in BPAP hydrolysis was detected when the Po2 was reduced from 110 to 10 Torr. The Vmax for BPAP hydrolysis by the lung was inversely correlated with the magnitude of the hypoxic vasoconstriction that occurred, suggesting that the reduced BPAP hydrolysis with hypoxia was due to the loss of perfused surface area due to the vasoconstriction. The results suggest that correlations between Pco2 and/or pH and whole-lung ACE activity that might occur in diseased lungs do not imply causalty. The hemodynamic consequences of changing Po2 (i.e., hypoxic vasoconstriction) may alter whole-organ ACE activity in the sense of changing the perfused surface area (i.e., the amount of ACE in contact with flowing perfusate).

Animals↗

Alveolar vessel behavior in the zone 2 lung inferred from indicator-dilution data.

To gain insight into the changes occurring in alveolar vessels when alveolar pressure exceeds venous pressure at the downstream end of the alveolar vessels (zone 2), we compared the uptake of serotonin and the extravascular volume accessible to 3HOH (Qev) under zone 2 and 3 conditions in isolated dog lung lobes. We also examined the influence of occluding some of the small pulmonary arteries with 58- to 548-micron-diam beads on the serotonin uptake and Qev. We found that, with the bead embolization, both the serotonin uptake and the Qev were reduced, whereas the change from zone 3 to 2 reduced serotonin uptake but did not change Qev. A plausible explanation for these observations is that the beads occluded vessels that were relatively large compared with those in which significant transvascular 3HOH exchange and serotonin uptake take place. Perfusion ceased in the collection of capillaries normally served by the obstructed arteries. Thus the extravascular water and the serotonin uptake sites downstream from the obstructions were not accessible to the indicators during the short time interval of the indicator passage through the lung. On the other hand, the change from zone 3 to zone 2 resulted in the collapse of small individual capillary segments within the alveolar vessel bed. Since the serotonin does not readily diffuse from the vessels through the tissue, it could not reach the endothelial cells of the collapsed capillaries. However, since the distances for diffusion between collapsed capillaries and neighboring perfused capillaries were small, the more highly diffusible 3HOH had access to the same Qev under both zone 2 and 3 conditions.(ABSTRACT TRUNCATED AT 250 WORDS)

Analysis of Variance↗