PubMed HealthSearch

Biomedical subjects

J H Yoo

Publications and source records attributed to J H Yoo.

7 recordsLinked to original sources

Evidence for the multistep nature of in vitro human epithelial cell carcinogenesis.

In keeping with the multistep development of human cancer in vivo, a stepwise approach to neoplastic transformation in vitro presents a reasonable strategy. We have recently developed an in vitro multistep model suitable for the study of human epithelial cell carcinogenesis. Upon infection with the adenovirus 12-simian virus 40 hybrid virus, primary human epidermal keratinocytes acquired an indefinite life span in culture but did not undergo malignant conversion. Subsequent addition of Kirsten murine sarcoma virus and human ras oncogene or chemical carcinogens (N-methyl-N'-nitro-N-nitrosoguanidine or 4-nitroquinoline 1-oxide) to these cells induced morphological alterations and the acquisition of neoplastic properties. Subsequently it was found that this line could be transformed neoplastically by a variety of retrovirus-containing H-ras, bas, fes, fms, erbB, and src oncogenes. In addition, we found that the immortalized human epidermal keratinocyte (RHEK-1) line can be transformed neoplastically by exposure to ionizing radiation. Thus, this in vitro system may be useful in studying the interaction of a variety of carcinogenic agents and human epithelial cells. These findings demonstrate the malignant transformation of human primary epithelial cells in culture by the combined action of viruses, oncogenes, chemical carcinogens, or X-ray irradiation and support a multistep process for neoplastic conversion.

Adenoviridae

Quantitative measurement of body motion using Schottky barrier silicon photodiode.

A new motion detection system has been developed using a laser beam and a Schottky barrier silicon photodiode. The system broadens the scope of gravitational center stabilography by facilitating the quantitative assessment of tremors of body appendages such as the hands and even the head. The system also eliminates cumbersome platforms and wire attachments previously used in gravitational center stabilography. The subject is asked to aim the beam at the photodiode. A quantitative off-center variation parameter, ARDS (Average Radial Distance Squared multiplied by time), was utilized in units of cm2 sec. A preliminary evaluation of the system shows that it is suitable for rapidly screening large numbers of subjects for localised neuromuscular control.

Electronics, Medical

Human skin burns induced by defibrillator default current: a mathematical simulation model.

A preliminary model was prepared for the development of superficial burns which can result from the interaction of faulty defibrillator and other electrical operating room equipment. A thermal model previously used to predict retinal coagulation was adapted to give temperature rise history of the skin. Skin resistance is assumed to decrease rapidly due to the instability of a small volume near the surface. Heating due to dissipation of the defibrillator capacitor energy in this skin volume is shown to be high enough to cause burns. A sensitivity analysis is included to isolate the dominant input parameters. Recommendations are made for future research.

Burns, Electric

Human skin burns induced by defibrillator default current.

The attachment of various types of electronic instrumentation to a patient can lead to hazardous interactions. Component malfunction in a single piece of equipment connected to a patient may be totally innocuous. However, the same fault occurring in an identical piece of equipment functioning as one component in a network of monitoring and electrosurgical equipment can result in severe burns or even electrocution. This paper describes interaction between a defective defibrillator paddle and an electrosurgical unit. Burns and ventricular fibrillation resulting from this malfunction and interaction are described in detail and the electrical circuits are analyzed.

Burns, Electric