Meniscal replacement in dogs. Tissue regeneration in two different materials with similar properties.

In earlier studies, meniscal replacement with a porous polymer implant led to regeneration of neo-meniscal tissue. To evaluate the influence of the chemical properties on the tissue regeneration in the implant, in the present study, the meniscus in the dog's knee was replaced with either an aromatic 4,4-diphenylmethanediisocyanate based polyesterurethane implant (Estane) (n = 6) or with an aliphatic 1,4-butanediisocyanate based polyesterurethane implant (PCLPU) (n = 6). After 6 months, the knee joints were resected and the tissue behavior in the two different prostheses was evaluated microscopically. In both prostheses, a meniscus-like distribution of the tissue phenotype was found with collagen type I in the peripheral fibrous zones and collagen type II in the central, more cartilaginous zones. The compression-stress behavior of the implant-tissue construct remained in between the stiffness of the polymer material and that of the native meniscus. The PCLPU implant seemed to provoke less synovial tissue reaction. After meniscectomy solely, in 5 out of 6 cases, a meniscus-like regenerate was formed. Furthermore, the articular cartilage degeneration after placing a PCLPU implant did also not exceed the degeneration after the Estane implant or after meniscectomy. The differences between these two implants did not seem to influence the tissue regeneration in the implant. However, PCLPU seemed to evoke less tissue reaction and, therefore, is thought to be less or even nontoxic as compared with the Estane implant. Therefore, for studies in the future, the authors prefer the PCLPU prostheses for replacement of the meniscus.

Animals↗

Pathological muscle activation patterns in patients with massive rotator cuff tears, with and without subacromial anaesthetics.

A mechanical deficit due to a massive rotator cuff tear is generally concurrent to a pain-induced decrease of maximum arm elevation and peak elevation torque. The purpose of this study was to measure shoulder muscle coordination in patients with massive cuff tears, including the effect of subacromial pain suppression. Ten patients, with MRI-proven cuff tears, performed an isometric force task in which they were asked to exert a force in 24 equidistant intervals in a plane perpendicular to the humerus. By means of bi-polar surface electromyography (EMG) the direction of the maximal muscle activation or principal action of six muscles, as well as the external force, were identified prior to, and after subacromial pain suppression. Subacromial lidocaine injection led to a significant reduction of pain and a significant increase in exerted arm force. Prior to the pain suppression, we observed an activation pattern of the arm adductors (pectoralis major pars clavicularis and/or latissimus dorsi and/or teres major) during abduction force delivery in eight patients. In these eight patients, adductor activation was different from the normal adductor activation pattern. Five out of these eight restored this aberrant activity (partly) in one or more adductor muscles after subacromial lidocaine injection. Absence of glenoid directed forces of the supraspinate muscle and compensation for the lost supraspinate abduction torque by the deltoideus leads to destabilizating forces in the glenohumeral joint, with subsequent upward translation of the humeral head and pain. In order to reduce the superior translation force, arm adductors will be co-activated at the cost of arm force and abduction torque. Pain seems to be the key factor in this (avoidance) mechanism, explaining the observed limitations in arm force and limitations in maximum arm elevation in patients suffering subacromial pathologies. Masking this pain may further deteriorate the subacromial tissues as a result of proximal migration of the humeral head and subsequent impingement of subacromial tissues.

Aged↗

Pathological Teres Major activation in patients with massive rotator cuff tears alters with pain relief and/or salvage surgery transfer.

BACKGROUND: Massive rotator cuff tears impose restraints on overhand arm functionality and are often accompanied by pain. After musculotendinous Teres Major transfer, overhand arm function is generally restored and pain is reduced. The assumed mechanical abduction insufficiency and Teres Major muscle function adaptation will be experimentally verified. METHODS: Principal Teres Major muscle activation (surface IEMG averaged over 3s) is recorded for 12-24 isometric and isotonic force directions perpendicular to the 60 degrees forward flexed humerus in three conditions: prior to surgery (n = 6 patients), prior to surgery and after subacromial anaesthetic (n = 6) and post-surgery (n = 3). Principal direction and on-, offset directions were estimated. FINDINGS: Teres Major activation adapts both to pathological and post surgery conditions: the normal activation during adduction changes into activation during forward flexion or abduction. Glenohumeral stabilisation, not abduction torque, seems to be the explanation for post surgery Teres Major transfer success. INTERPRETATIONS: The pathological absence of Supraspinatus and Infraspinatus forces during forward flexion result in increased upward glenohumeral instability. The superior translations are compensated for by Teres Major activity during forward flexion. This translation-'force' function conflicts with the adduction-generating rotation-'torque' function. This may explain the pain-induced reduction of arm elevation in these patients. Musculotendinous transfer solves the force-torque conflict by changing the moment arm of the Teres Major from adduction to abduction. Teres Major can now both compensate for the loss of Supraspinatus and Infraspinatus forces needed for glenohumeral stabilisation and contribute to forward flexion of the arm.

Biomechanical Phenomena↗

Presence and mechanism of knee articular cartilage degeneration after meniscal reconstruction in dogs.

OBJECTIVE: Partial meniscectomy is the golden standard for treating a bucket-handle tear in the meniscus of the knee, but it inevitably leads to articular cartilage degeneration. Surgical creation of an access channel between the lesion and the vascularized synovial lining is intended to induce ingrowth of repair tissue and thus avoid degeneration of articular cartilage. DESIGN: The presence and mechanism of cartilage degeneration were evaluated in 24 canine menisci after a longitudinal lesion and access channel had been created in the avascular part of the meniscus. In 12 menisci the channel was implanted with a porous polymer scaffold, while the remaining 12 were left empty. Evaluation was performed using routine histology and antibodies directed against denatured type II collagen (Col2-3/4M). RESULTS: Articular degeneration was apparent in the polymer implant group and the empty channel group. This consisted of fibrillation, loss of chondrocytes and decreased proteoglycan content. Areas of fibrillated cartilage always showed positive labeling with the collagen degradation antibody Col2-3/4M. Collagen degradation was also visible in non-fibrillated areas. The upper zone of the cartilage showed swelling especially in the implant group, with empty cell lacunae and moderate levels of Col2-3/4M antibody labeling. DISCUSSION: This reconstruction technique cannot be considered superior to partial meniscectomy. We propose that degradation of the collagen type II network is a result of cartilage fibrillation and vice versa.

Animals↗

A three-dimensional regression model of the shoulder rhythm.

OBJECTIVE: The development of a thorax-fixed regression model for the shoulder which statistically predicts the orientation of the clavicle and the scapula from the humerus orientation. BACKGROUND: The application of three-dimensional position recording systems to the shoulder mechanism is limited to laboratory conditions. Studies in the field of ergonomics and sports require a method that can be applied in situ. It was found that the relation between the scapular and the humeral motions is consistent. In order to facilitate the biomechanical research on the shoulder a descriptive statistical model of the shoulder rhythm was developed. METHODS: The orientation of the shoulder bones of 10 subjects was determined in a large range of 23 humerus positions. The elbow was flexed in a splint and the arm was fully supported. The subjects exerted a 20 N external abduction and adduction force at the elbow in a plane perpendicular to the humerus. Other forces and moments were mechanically minimized. During the task the postures of the shoulder were recorded. The linear regression equations for the clavicular and scapular orientations were determined by means of a repeated measurements multi-variate analysis of variance for the co-variates: humerus orientation, initial orientation of the clavicle and the scapula, external force direction, gender and morphological characteristics of the subjects. RESULTS: The orientation of the clavicle and the scapula was predicted by five linear regression equations, including the co-variates: humerus orientation, external force direction and initial position. Morphology and gender did not significantly contribute to the clavicular and scapular orientation predictions. CONCLUSIONS: A statistical model is developed for the prediction of clavicular and scapular orientations, based on the humerus position, the initial posture and the direction of the external force. The model fitted well on an independent set of recorded position data for a different group of subjects. RELEVANCE: Morphological data of the shoulder girdle and gender did not significantly contribute to the model structure.

Biomechanical Phenomena↗

Injectable intraocular lens materials based upon hydrogels.

The possibilities to develop an injectable hydrogel lens were investigated. Aqueous solutions of reactive polymers in combination with a water-soluble blue light photoinitiator were transformed into hydrogels by irradiation with blue light. Poly(ethylene glycol) diacrylates (PEGDA) with low molecular weights and an acrylate modified copolymer of N-vinylpyrrolidone and vinyl alcohol with a high molecular weight were used as reactive polymers. A copolymer of (4-vinyl-2,6-dimethylbenzoyl)diphenylphosphine oxide and dimethylacrylamide was used as a water-soluble blue light photoinitiator. PEGDA showed high reactivity and the hydrogels were more transparent than the natural lens. The mass loss and the additional swelling of the hydrogel were 1.0 and 4.0%, respectively. The refractive index of these hydrogels was 1.40, lower than that of natural lens. The viscosity of the solutions before cross-linking was too low for injection into the capsular bag. Hydrogels based upon the copolymer had a transmission comparable to a 25-year-old natural lens. The materials showed no mass loss and the additional swelling after curing was less than 1%. The refractive index was comparable to that of the natural lens (1.42). The viscosity of the polymer solutions was sufficient for injection into the capsular bag without leakage.

Adult↗

Hydrophilic polymeric acylphospine oxide photoinitiators/crosslinkers for in vivo blue-light photopolymerization.

Three vinyl-functionalized phosphine oxide photoinitiating monomers have been synthesized: 4-vinylbenzoyldiphenylphosphine oxide (VBPO), 2,6-dimethyl-4-vinylbenzoyldiphenylphosphine oxide (DMVBPO), and 2,4,6-trimethylbenzoylphenyl-4-vinylphenylphosphine oxide (TMBVPO). VBPO was copolymerized with vinylpyrrolidone or vinyl acetate (PPI-1a) and dimethylacrylamide (PPI-1b). DMVBPO and TMBVPO were both copolymerized with dimethylacrylamide (PPI-2 and PPI-3, respectively). The choice of vinylphosphine oxide and comonomer(s) had a significant influence on the properties of the resulting PPI. PPI-1a was not stable in solution in 2-hydroxyethyl methacrylate (HEMA), whereas the VBPO-dimethylacrylamide (DMA) copolymer (PPI-1b) was stable in HEMA but not stable in aqueous solutions. PPI-2 was both soluble and stable in water up to 22 months. PPI-1a was as effective as trimethylbenzoyldiphenylphosphine oxide (TPO, BASF Lucirin). PPI-2 was more effective in the polymerization of HEMA/water mixtures than PPI-3. PPI-2 and PPI-3 acted as self-cross-linking species, resulting in the formation of hydrogels; PPI 3 was more effective in this. PPI-2 was very effective in forming hydrogels based on poly(ethylene glycol) diacrylate.

Biocompatible Materials↗

Solvent-free fabrication of micro-porous polyurethane amide and polyurethane-urea scaffolds for repair and replacement of the knee-joint meniscus.

New porous polyurethane urea and polyurethane amide scaffolds for meniscal reconstruction have been developed in a solvent-free process. As soft segments, copolymers of 50/50 L-lactide/epsilon-caprolactone have been used. After terminating the soft segment with diisocyanates, chain extension was performed with adipic acid and water. Reaction between the isocyanate groups and adipic acid or water provides carbon dioxide and results in a porous polymer. Extra hydroxyl-terminated prepolymer was added in order to regulate the amount of carbon dioxide formed in the foaming reaction. Furthermore, salt crystals ranging in size from 150 to 355 microm were added in order to induce macroporosity. The pore size was regulated by addition of surfactant and by the use of ultrasonic waves. The resulting porous polymer scaffolds exhibit good mechanical properties like a high-compression modulus of 150 kPa. Chain extension with adipic acid results in better mechanical properties due to better defined hard segments. This results from the lower nucleophilicity of carboxylic acids compared to water and alcohols. By adjusting the reaction conditions, materials in which macropores are interconnected by micropores can be obtained. On degradation only non-toxic products will be released; importantly, the materials were obtained by a simple, reproducible and solvent-free procedure.

Knee Injuries↗

The scapulo-humeral rhythm: effects of 2-D roentgen projection.

OBJECTIVE: The objective of this study is to illustrate the low accuracy of two-dimensional (2-D) X-ray projection methods for the quantification of the three-dimensional (3-D) shoulder motions. BACKGROUND: The traditional method for the quantification of the gleno-humeral motion is by means of 2-D X-ray recording. The motion was characterized by the scapulo-humeral rhythm: the ratio of the nett humeral elevation over nett scapular rotation. The method was based on the quantification of the planar projection of the spatial positions of X-ray dense structures of the scapula. The deformations introduced by the central projection method, a feature of X-ray projection, cannot be compensated for by calibration: the position of the scapula with respect to the camera setting is unknown, and skeletal landmarks of the scapula cannot uniquely be identified. The transformation from 3-D orientations to 2-D angles will, therefore, be inaccurate. METHODS: A 2-D X-ray projection of the scapula during a typical arm abduction was simulated. The 3-D motion was obtained by means of palpation and subsequent digitization of skeletal landmarks of the scapula. The 3-D positions of the recorded landmarks were projected on a plane by a simulation based on the parameters of the X-ray equipment. The scapulo-humeral rhythm was calculated for the different scapular landmarks, and for the orientation of the subject with respect to the projection axis. The results were compared with previous published scapulo-humeral rhythms. RESULTS: The scapulo-humeral rhythm depends both on the choice of the skeletal landmarks, used to quantify the scapular rotations, and on the orientation of the subject in the X-ray setting. The full range of results obtained from earlier published experiments could be obtained from a simulation based on a single 3-D arm abduction. CONCLUSIONS: The 2-D scapulo-humeral rhythm, obtained from planar X-ray projection, is an inaccurate parameter to define the scapular motions. RELEVANCE: The 2-D scapulo-humeral rhythm is an insensitive parameter to identify clinical disorders in the gleno-humeral motions, 3-D motion recording should be applied. Only when stringent precautions are taken with respect to repeatability of positioning of the subjects, can the method be used to study intra-individual effects, e.g., the follow-up of patients during treatment.

Biomechanical Phenomena↗

Effect of different arm loads on the position of the scapula in abduction postures.

OBJECTIVE: The objective of this study is to determine the relation between arm load and the three-dimensional shoulder orientations. BACKGROUND: Analysis of a musculo-skeletal system by means of an inverse dynamical simulation requires postural data of the bony elements involved. For the shoulder, the positions of the clavicle and the scapula are difficult to record due to the skin displacement. It would therefore be useful to predict the three-dimensional relation between the orientation of the arm, the clavicula and the scapula, i.e. the three-dimensional shoulder rhythm, with respect to the thorax under different load conditions. METHODS: The orientation of the clavicula and the scapula was determined with respect to the thorax by means of palpation of skeletal landmarks, for seven postures of arm elevation in the frontal plane at four load conditions: 0, 0.9, 1.9 and 2.9 kg at the wrist. The data were expressed by Cardan angles and analyzed by means of repeated measurements analysis of variance. RESULTS: While the clavicular and scapular angles were significantly related to the arm elevation, no significant relation was found with the load in the hands for the seven arm postures. CONCLUSIONS: The three-dimensional shoulder rhythm does not change under different gravitational load conditions on the arm. RELEVANCE: The fact that the magnitude of the load does not affect the shoulder postures, i.e. the moment arms of the muscles, facilitates the biomechanical, ergonomical and clinical studies on the shoulder by the reduction on the number of recordings for equal task under different load conditions, and easy imitation of real life tasks in the laboratory.

Adult↗

Meniscal tissue regeneration in porous 50/50 copoly(L-lactide/epsilon-caprolactone) implants.

Porous materials of a high-molecular-weight 50/50 copolymer of L-lactide and epsilon-caprolactone with different compression moduli were used for meniscal repair. In contrast to the previously used 4,4'-diphenylmethane and 1,4-trans-cyclohexane diisocyanates containing polyurethanes, degradation products of the copolymer are non-toxic. Two series of porous materials with compression moduli of 40 and 100 kPa respectively were implanted in the knees of dogs using a new, less traumatizing suturing technique. A porous aliphatic polyurethane series with compression modulus of 150 kPa was implanted for comparison. Adhesion of the implant to meniscal tissue was found to be essential for healing of the longitudinal lesion. Copolymer implants showed better adhesion, probably due to the higher degradation rate of the copolymer. Fibrocartilage formation was found to be affected by the compression modulus of the implant. Implants with a modulus of 40 kPa did not show ingrowth of fibrocartilage, whereas implants with compression moduli of 100 and 150 kPa yielded 50-70 and 80-100% fibrocartilage respectively. During degradation the copolymer phase separated into a crystalline phase containing mainly L-lactide and an amorphous phase containing mainly epsilon-caprolactone. The copolymer degraded through bulk degradation.

Animals↗

Meniscal replacement using a porous polymer prosthesis: a preliminary study in the dog.

A porous polyurethane prosthesis was used to replace the lateral meniscus in the dog. After an initial ingrowth of fibrous tissue, the prostheses became filled with tissue strongly resembling normal meniscal fibrocartilage. Although less severe than seen after total meniscectomy, cartilage degeneration was frequent, possibly because tissue ingrowth in the prostheses occurred too slowly. Porous polymers can be useful for replacement of the meniscus, provided that chemical and physical properties are optimized.

Animals↗

Use of porous polyurethanes for meniscal reconstruction and meniscal prostheses.

In the past, porous materials made of an aromatic polyurethane (PU) were successfully used to meniscal reconstruction in dogs. Since aromatic PUs yield very toxic fragments upon degradation, a linear PU was synthesized by curing a poly(epsilon-caprolactone) and 1,4-trans-cyclohexane diisocyanate based prepolymer with cyclohexanedimethanol. Porous materials of this polymer were also implanted for meniscal reconstruction. The results were comparable with the most successful implant series so far. Additionally, a porous meniscal prosthesis was developed to replace a total meniscus. Due to the very high shear stresses to which the prosthesis would be exposed, the stress hysteresis phenomenon linear PUs are known to exhibit could be of great consequence. Therefore an aliphatic PU network, synthesized by cross-linking poly(epsilon-caprolactone) and 1,4-trans-cyclohexane diisocyanate with glycerol, was used. Dislocation caused by tearing out of the sutures was found to be a problem because the tear resistance of the material was relatively low. In this study the tearing problem has been partly circumvented by using a complex suturing technique. Meniscal prostheses turned out to induce fibrocartilage upon implantation, and degeneration of articular cartilage was less severe than after meniscectomy.

Animals↗

Meniscal repair by fibrocartilage in the dog: characterization of the repair tissue and the role of vascularity.

Lesions in the avascular part of 20 canine menisci were repaired by implantation of a porous polyurethane. Seven menisci were not repaired and served as controls. The repair tissue was characterized by biochemical and immunological analysis. The role of vascularity in healing was studied by perfusion of menisci with Indian ink. Histologically, repair tissue inside the implants initially consisted of fibrous tissue containing type I collagen. After 2 months, fibrocartilaginous tissue developed inside the implants, whereas control defects only showed repair with fibrous tissue. Both type I and type II collagen, the two major collagen types of normal meniscal fibrocartilage, could be detected in this newly formed fibrocartilage. The implant guided vascular tissue from the periphery towards the lesion resulting in healing of the tear. After fibrocartilage had formed, vascularity decreased and was completely absent in mature fibrocartilage. Control defects remained filled with vascular connective tissue. Two-thirds of the longitudinal lesions were found to be healed partially or completely. It is concluded that implantation of a porous polymer does enhance vascularity sufficiently to result in healing of meniscal lesions extending into the avascular part. Healing takes place by repair tissue strongly resembling normal meniscal fibrocartilage.

Animals↗

Porous implants for knee joint meniscus reconstruction: a preliminary study on the role of pore sizes in ingrowth and differentiation of fibrocartilage.

Implants with four different macropore sizes were implanted in the meniscus of 29 rabbits for assessment of ingrowth and differentiation of fibrocartilage. Implant macropores were 50-90, 90-150, 150-250 and 250-500 mum, the vol.% macropores was 48-55 and total pore volume 84-86 vol.%. Ingrowth was optimal in the two large pore implants whereas the small pore implants partially remained empty up to 1 year post-operative. Capsule formation and the foreign body reaction was severe for the small pore implants whereas this occurred to a lesser extent in the two large pore implants. Fibrocartilage formation, as assessed by morphology and antibody labelling for type I and type II collagen, was observed in a similar way in all implant types. It is concluded that for optimal ingrowth and incorporation of partial or total meniscal prosthesis, macropore sizes must be in the range of 150-500 mum.

Animals↗

Meniscal repair by fibrocartilage? An experimental study in the dog.

Longitudinal lesions in the avascular part of the dog's meniscus were repaired by implantation of a porous polyurethane. Ingrowing repair tissue was characterized by biochemical and immunological analysis. Histologically, repair tissue initially was composed of fibrous tissue containing type I collagen. After 3 months, fibrocartilaginous tissue developed inside the implants, whereas control defects only showed fibrous repair tissue. Both type I and II collagen, the major collagen types of normal meniscal fibrocartilage, could be detected in this newly formed fibrocartilage. It is concluded that fibrocartilage resembling normal meniscal tissue is formed and that longitudinal lesions can be healed after meniscal repair by implantation of a porous polymer.

Animals↗

Porous polymer implants for repair of full-thickness defects of articular cartilage: an experimental study in rabbit and dog.

Full-thickness defects of articular cartilage were repaired by implantation of porous polymer implants in rabbits and dogs. The quality of the repair tissue was determined by collagen typing with antibodies. Implants with varying pore sizes and chemical composition were used. The effect of loading and motion was determined by inserting implants higher than, level with and lower than the surrounding cartilage. It appeared that healing took place by formation of fibrocartilaginous repair tissue containing both type I and type II collagen. Hyaline cartilage was observed in a minority of the rabbits used but not in the dog. Fibrocartilage formation in the dog was simulated by implantation of a porous polymer. Chemical composition of the polymer did not alter the results, neither did loading of the implant. It is concluded that the formation of fibrocartilaginous repair cartilage is stimulated by implantation of a porous polymer. This tissue seemed to function adequately in the dog but did show signs of degeneration in the rabbit.

Animals↗

Porous polymer implant for repair of meniscal lesions: a preliminary study in dogs.

Artificial meniscal lesions extending into the avascular part of the meniscus, which do not heal by any other means, were repaired by suturing either a porous polymer implant or a synovial flap into the defect. The implant guided the ingrowth of vascular repair tissue into the defect. This fibrous tissue later on transformed into fibrocartilage. Reconstruction with a synovial flap was not successful. It appeared that healing can be achieved by implantation of a porous polymer implant in a large number of cases. Future research will be aiming at improvement of the results of meniscal repair and application of this type of polymer for repair of cartilage defects.

Animals↗