Monte Carlo simulation of a medical linear accelerator for radiotherapy use.

A Monte Carlo code MCNPX (Monte Carlo N-particle) was used to model a 25 MV photon beam from a PRIMUS (KD2-Siemens) medical linear electron accelerator at the Centre Antoine Lacassagne in Nice. The entire geometry including the accelerator head and the water phantom was simulated to calculate the dose profile and the relative depth-dose distribution. The measurements were done using an ionisation chamber in water for different square field ranges. The first results show that the mean electron beam energy is not 19 MeV as mentioned by Siemens. The adjustment between the Monte Carlo calculated and measured data is obtained when the mean electron beam energy is approximately 15 MeV. These encouraging results will permit to check calculation data given by the treatment planning system, especially for small fields in high gradient heterogeneous zones, typical for intensity modulated radiation therapy technique.

Body Burden↗

Monte Carlo simulation of a protontherapy platform devoted to ocular melanoma.

Patients with ocular melanoma have been treated since June 1991 at the medical cyclotron of the Centre Antoine Lacassagne (CAL). Positions and sizes of the ocular nozzle elements were initially defined based on experimental work, taking as a pattern functional existing facilities. Nowadays Monte Carlo (MC) calculation offers a tool to refine this geometry by adjusting size and place of beam modeling devices. Moreover, the MC tool is a useful way to calculate the dose and to evaluate the impact of secondary particles in the field of radiotherapy or radiation protection. Both LINAC and cyclotron producing x rays, electrons, protons, and neutrons are available in CAL, which suggests choosing MCNPX for its particle versatility. As a first step, the existing installation was input in MCNPX to check its aptitude to reproduce experimentally measured depth-dose profile, lateral profile, output-factor (OF), and absolute dose. The geometry was defined precisely and described from the last achromatic bending magnet of our proton beam line to the position of treated eyes. Relative comparisons of percentage depth-dose and lateral profiles, performed between measured data and simulations, show an agreement of the order of 2% in dose and 0.1 mm in range accuracy. These comparisons, carried out with and without beam-modifying device, yield results compatible to the required precision in ocular melanoma treatments, as long as adequate choices are made on MCNPX input decks for physics card. Absolute dose and OF issued from calculations and measurements were also compared. Results obtained for these two kinds of data, carried out in the simplified situation of an unmodulated beam, indicate that MC calculation could effectively complement measurements. These encouraging results are a large source of motivation to promote further studies, first in a new design of the ocular nozzle, and second in the analysis of the influence of beam-modifying devices attached to the final patient collimator, such as wedge or compensators, on dose values.

Computer Simulation↗

[Study of theoretical cases of intensity-modulated beams with step-and-shoot technique].

To initiate Intensity-Modulated Radiation Therapy (IMRT) in our department, theoretical cases were used as a training, to define methods of measurements and to verify the software by comparing results of calculation and measurement on a PMMA phantom. Irradiation was performed with 6 and 25 MV X-rays from a linear accelerator. For measurements, films and ionization chambers have been chosen. The comparison between calculations and measurements shows some discrepancies at the level of junctions and also in areas of low doses especially when many segments were used. These theoretical cases provide a first step on the way towards treatments with intensity modulation.

Bias↗

Validation of intensity modulation on a commercial treatment planning system.

For two years now, a study on intensity modulated radiotherapy (IMRT) has been in progress at the Antoine Lacassagne Hospital Center for Cancer Therapy (in Nice) in collaboration with the University of Nice-Sophia Antipolis. The kind of intensity modulation that was used is the "step and shoot" technique in which the modulated beam is created both by adding andjoining elementary fields. Before carrying out clinical tests, several problems regarding the production of modulated beams has to be mastered. The current developments of our study enable us to dosimetrically produce (in water phantom and in the PMMA phantom) complexmodulated whose segmentation was calculated by one commercial treatment planning system (TPS). Nevertheless, we showed and studied some critical discrepancies between standard clinical calculations and the calculations using field segmentation. We showed that with nonoptimal conditions of segmentation the discrepancies, which are due to the type of algorithm used, could bring about significant errors inside the field of up to 10% of maximum dose. Another point of our study is the quantification and resolution of differences between measurements and calculations due to the internal segmentation of calculated modulated fields and their realization on Linac. Once again, in none optimal conditions of segmentation and inside the field we obtained discrepancies up to 20% of maximum dose between calculations using field segmentation and measurements. That was mainly due to the tongue and groove effect and penumbra phenomena. This study allows us to show that the discrepancies between segmentation calculations and standard clinical calculations should be solved by the use of penumbra models during segmentation calculations. We will introduce both the study and its near-future perspectives.

Algorithms↗

Nonhomogeneous resolution of images of natural scenes.

The aim of this research is to model and simulate the loss of visual resolution as a function of retinal eccentricity in the perception of natural scenes. The model of visual resolution is based on a space-variant low-pass filter, having a variable convolution kernel according to retinal eccentricity. The parameters of the model are computed from psychophysical measures of visual acuity as a function of retinal eccentricity. The implementation of the model allowed us to generate images of scenes with nonhomogeneous space-variant resolution, simulating the filtering executed by the eye. These scenes are used to test and optimise the model by means of experiments in static vision (through tachistoscopic presentations) and in dynamic vision where the resolution of the scene is computed, in real-time, as a function of the location of gaze.

Contrast Sensitivity↗

Results of proton therapy of uveal melanomas treated in Nice.

PURPOSE: To present the first results of uveal melanomas treated with the Medicyc Cyclotron 65 MeV proton beam facility in Nice, analyzing the factors that affect the cause-specific survival (CSS), metastatic rate, and reporting the visual outcome. METHODS AND MATERIALS: This study concerns 538 patients referred by French institutions between June 1991 and December 1996. The eye and tumor parameters were measured using ultrasonography and angiography. Since 1994, CT scans were performed in most patients to help determine the axial length and the shape of the ocular globe. Tantalum clips were inserted around the tumor by the referring ophthalmologist. There were 349 posterior pole tumors (64.9%), 130 equatorial tumors (24.1%), and 59 ciliary body tumors (11%). Two hundred four patients (37.9%) had T1 or T2 tumors, and 334 patients (62.1%) had T3 or T4 tumors. The median tumor diameter was 14.6 mm, and the median tumor height was 5.1 mm. All patients received 52 Gy (57.20 Gy Co-equivalent dose) on 4 consecutive days. The data were analyzed by December 1997. RESULTS: The CSS was 77.4% at 78 months, the overall survival was 73.8% and the local control was 89.0%. The CSS was not influenced by the patient age or the site of the tumor. It was 81.5% for T1 and T2 tumors, versus 75% for T3 and T4 tumors (P = 0.035). It was found that the tumor diameter, rather than the height, was the most important parameter affecting outcome. The metastatic rate was 8%. It depended on the T stage, tumor diameter and thickness, but not the tumor site. Thirty-eight enucleations were performed, most of them due to tumor progression and/or glaucoma. One-third of the patients in whom visual acuity was adequately scored before and after treatment had a stable, if not improved vision, and half the patients retained useful vision after treatment. CONCLUSION: The outcome of patients suffering from uveal melanoma and treated with high-energy protons compares favorably with other techniques of treatment. The tumor dimensions affected CSS and metastatic rate. Even though two-thirds of patients had posterior pole tumors, half of them retained useful vision.

Age Factors↗

Proton beam dosimetry: a comparison between the Faraday cup and an ionization chamber.

From the theoretical point of view, the Faraday cup (FC) is an absolute instrument for fluence measurements of proton beams. As the FC is easily manufactured it can be considered an 'in-house' calibration system. Moreover, at the moment no national standards for proton dosimetry are available. Up to now the experimental tests of these instruments show that much study still has to be done to better understand their use in reference dosimetry. To investigate the possibility of using an FC as a secondary standard, an FC was jointly designed by the 'TERA Collaboration' and 'Centre Antoine-Lacassagne' (Nice, France) to evaluate the main parameters of the instrument. A comparison between two FCs of different designs--the 'TERA FC' and the 'Nice FC'--and an ionization chamber (IC) used for routine proton dosimetry was carried out. Results show that the two FCs agree to within 1.5-3.6%. While the differences between FC and IC are larger--6% for the 'TERA FC' and 8.2% for the 'Nice FC', the FC giving a lower dose evaluation--they follow the same trend shown by the calorimetric measurements. The data show that once the beam characteristics are defined, the fluence measurements are reproducible and show a good accuracy.

Biophysical Phenomena↗

Serotonin and autism: biochemical and molecular biology features.

Whole blood and urinary levels of serotonin (5-hydroxytryptamine; 5-HT) and the derivative urinary 5-hydroxyindoleacetic acid (5-HIAA) were measured in normal and autistic subjects. An association was tested between autism and a marker coding for the 5-HT2A serotonergic receptor gene. Significant group (high urinary 5-HT and low whole blood 5-HT in autism) and age effects (urinary 5-HT decrease with age) were found. Moreover, whole blood 5-HT levels were correlated with clinical state. No differences in allele and genotype frequencies for the 5-HT2A receptor marker were found in this autistic population compared with age-matched healthy students.

Adolescent↗

X chromosome and infantile autism.

Family studies and epidemiologic data in autism show the involvement of genetic factors in the etiology of this syndrome. The frequent association of X chromosome with mental retardation and behavior disturbances raises the question of its implication in the etiology of autism. Several markers of X chromosome were tested in autistic and control populations by association study. The autistic population was submitted to an extensive clinical examination. For the DXS287 marker, chi 2 analysis showed a different allele distribution between control and patient groups. This difference was enhanced when children with the most severe autistic behaviors and the least serious cognitive disorders were selected for statistical comparison. To our knowledge, this is the first association study described using markers of X chromosome in infantile autism. These preliminary results encourage our research on this chromosome, which could be considered as a significant genetic component of the multifactorial etiology of autism.

Adolescent↗

Changes in biological effectiveness with depth of the Medicyc neutron therapy beam.

V79 cells were exposed to fast neutrons generated by 60 MeV p-->Be produced by the cyclotron Medicyc at four different depths: 1.3, 25.8, 72.2 and 116.8 mm. Survival was assessed by the in vitro colony method. Mean inactivation doses (MID) were significantly different among the four points. The ratio of MID was used to determine the relative efficiency of the neutron beam at these points. Compared to 25.8 mm depth, a 40% increase in biological effect was observed at the superficial point versus a 14 to 16% decrease in effect for the deeper points. This is ascribed to absorption of low energy neutrons near the surface and to beam hardening with depth. Taking in consideration the relative physical dose delivered, these findings suggest that skin-sparing may be markedly reduced and that the lower effectiveness with depth should be kept in mind when dealing with deep tumours.

Cell Survival↗

Boron neutron capture irradiation: setting up a clinical programme in Nice.

Neutron capture irradiation aims to selectively destroy tumor cells using 10B(n,alpha)7Li nuclear reactions produced within themselves. Following the capture reaction, an alpha particle and a, 7Li ion are emitted. Carrying an energy of 2.79 MeV, they destroy all molecular structures along their path close to 10 microns. These captures, used exclusively with a 'slow' neutron irradiation, provide a neutron capture therapy (BNCT). If they are used in addition to a fast neutron beam irradiation, they provide a neutron capture potentiation (NCP). The Centre Antoine-Lacassagne in Nice is actively involved in the European Demonstration Project for BNCT of grade IV glioblastomas (GBM) after surgical excision and BSH administration. Taking into account the preliminary results obtained in Japan, work on an 'epithermal' neutron target compatible with various cyclotron beams is in progress to facilitate further developments of this technique. For NCP, thermalized neutron yield has been measured in phantoms irradiated in the fast neutron beam of the biomedical cyclotron in Nice. A thermal peak appears after 5 cm depth in the tissues, delayed after the fast neutron peak at 1.8 cm depth. Thus, a physical overdosage of 10% may be obtained if 100 ppm of 10B are assumed in the tissues. Our results using CAL 58 GBM cell line demonstrate a dose modification factor (DMF) of 1.19 when 100 ppm of boric acid are added to the growth medium. Thus for the particles, issued from neutron capture, a biological efficiency at least twice that of fast neutrons can be derived. These results, compared with historical data on fast neutron irradiation of glioblastoma, suggest that a therapeutic window may be obtained for GBM.

Boron Neutron Capture Therapy↗

Proton therapy in ophthalmology: status report and problems encountered.

The proton therapy facility of the Centre Antoine-Lacassagne in Nice began treatment of ocular tumors in June 1991. Up to October 1995, a total number of 600 patients were treated. An overview of the cases treated during the first 4 years of activity is given and the main problems encountered in the field, possibly interacting with the accuracy and reliability of the dose distribution, are listed.

Cyclotrons↗

Autism and genetics: clinical approach and association study with two markers of HRAS gene.

Twin studies and familial aggregation studies indicate that genetic factors could play a role in infantile autism. In an earlier study, we identified a possible positive association between autism and a c-Harvey-ras (HRAS) oncogene marker at the 3' end of the coding region. In an attempt to confirm this finding, we studied a larger population, well-characterized clinically and genetically. We report a positive association between autism and two HRAS markers, the 3' marker used in the initial study and an additional marker in exon 1.

Adolescent↗

Micronucleus induction and reproductive death in a human cell line exposed to low-energy argon beam.

Little is known about the action of charged particles of very high linear energy transfer (LET) on human cells and, in particular, the relationship between DNA damage and reproductive death. The aim of this study was to measure the biological efficiency of a low-energy argon beam (E = 7.1 MeV/nucleon, LET = 1590 keV/micron) produced at GSI, Darmstadt, on a human melanoma cell line (CAL4) established in our Institute. Two different methods were used: the micronucleus (MN) test and the colony-forming assay. The MN test, using the cytochalasin-block method, is a measure of genotoxic damage. MN are scored in binucleate cells (BNC) and are formed from acentric fragments or whole chromosomes that have not been incorporated into daughter nuclei at mitosis. The colony-forming assay quantifies reproductive death. Parallel experiments were run with cobalt gamma-rays for comparison. After Co irradiation, the MN-free BNC dose-response curve coincided with that of the loss of colony-forming ability, suggesting the potential of the former as a predictive test of cell killing. After Ar irradiation, there was a dissociation between the two effects, especially at high doses: cell death was greater than the frequency of BNC with MN. The inactivation cross-section was 74 microns2; it was 39 microns2 for MN yield. Therefore, the relative biological effectiveness (RBE) was higher for cell killing than for MN yield (0.8 and 0.5, respectively at a Co dose of 3 Gy). The total MN count in BNC followed the same pattern of response as the fraction of BNC with MN.(ABSTRACT TRUNCATED AT 250 WORDS)

Argon↗

Association study with two markers of a human homeogene in infantile autism.

Epidemiological data and family studies in autism show that there is a genetic susceptibility factor in the aetiology of this syndrome. We carried out an association study in infantile autism. Two markers of the homeogene EN2 involved in cerebellar development were tested in a population of 100 autistic children and in a population of 100 control children. With the MP4 probe showing a PvuII polymorphism, significant differences in the allele frequencies between the two populations were found (chi 2 = 7.99, df = 1, p < 0.01). With the MP5 probe showing an SstI polymorphism, no difference appeared (chi 2 = 1.17, not significant). Several clinical examinations allowed us to characterise the autistic children. Most of them had high scores for autistic behaviour and language disorders but low scores for neurological syndromes. Two children had a significant family history and six children had confirmed syndromes or diseases of genetic origin. Discriminant analysis between clinical and molecular data did not give significant results. These preliminary results must be supported by further analyses of this gene and by studies of its potential involvement in the pathophysiology of the autistic syndrome.

Adolescent↗