PubMed Health⌕ Search

Biomedical subjects

J Hemmerlé

Publications and source records attributed to J Hemmerlé.

11 recordsLinked to original sources

Mechanically responsive films of variable hydrophobicity made of polyelectrolyte multilayers.

Mechanically responsive surfaces that allow to switch reversibly from a hydrophobic to a hydrophilic substrate are reported. The surfaces are constituted of polyelectrolyte multilayers deposited on modified charged silicone sheets. n bilayers of poly(allylamine)-Nafion (PAH-Naf) and m bilayers of poly(allylamine)-poly(acrylic acid) (PAH-PAA) composed the multilayers. A (PAH-Naf)(n) film possesses a water contact angle of around 105 degrees, whereas the contact angle of a (PAH-Naf)(4)-(PAH-PAA)(m) multilayer is around 50 degrees. When such a film with m < 5 and terminated by PAA is stretched out, its water contact angle increases up to around 100 degrees. Successive elongation/retraction cycles allow the water contact angle to alternate reversibly between 100 and 57 degrees indicating the reversible mechanical responsive nature of the film.

Letter↗

Modeling of the detachment of a molecule from a surface: illustration of the "Bell-Evans effect".

This article deals with the modeling of the detachment of a molecule initially adsorbed on a surface and submitted to an external force whose strength increases with time. By means of an atomic force microscope (AFM), it is possible to measure the force when the molecule separates from the substrate. However, it is known that this force depends to a large extend on the rate at which the pulling force is applied ("Bell-Evans effect"). Two models are described to illustrate this behavior. First, a random walk approach is suggested to reveal the fundamental principle of the escape over a time-dependent energy barrier. Second, a multi bead-and-spring model is proposed to mimic the AFM experiment and numerical simulations, based on Brownian dynamics, are performed.

Binding Sites↗

Odontoblast dysfunction in osteogenesis imperfecta: an LM, SEM, and ultrastructural study.

The inherited dentin defect dentinogenesis imperfecta (DI), while clinically obvious in osteogenesis imperfecta (OI) Types IB and IC, II, III, and IVB, is now thought to be present in all children with OI, in a continuum from minimal to severe dentin pathology. This collaborative study further clarifies the structural and ultrastructural dentin changes in the teeth of OI children with clinically obvious DI, and attempts to explain these in terms of odontoblast dysfunction. Collaborative studies were carried out in Melbourne, Australia, and Strasbourg, France, using light and polarized-light microscopy, scanning and transmission electron microscopy (SEM, TEM), selected-area diffraction (SAD), and x-ray spectroscopy (EDX). These showed structurally normal enamel (but containing long and broad lamellae) and a normally scalloped dentino-enamel junction (DEJ), but severe pathologic changes in the dentin. An initial narrow band of normal-appearing dentin tubules (including the mantle layer) ceased abruptly and was replaced by a wavelike laminar zone parallel to the DEJ with occluded tubules. Multiple parallel channels of 5-10 microns diameter were present at right angles to the DEJ indenting this zone, some terminating in retro-curved "processes." The abnormal dentin containing these channels almost completely occluded the pulp chamber. The structural and ultrastructural changes seen can be explained on the basis of the collagen defect in OI resulting in odontoblast dysfunction, which produces a distinct phenotype and one that is different from that in bone.

Child↗

Semi-automatized processing of AFM force-spectroscopy data.

Atomic force microscopy operated in the force-spectroscopy mode is now a widespread technique, often used to investigate ligand-receptor interactions with the goal of measuring forces at the individual molecule level. However, in an experiment, the simultaneous interaction of several ligand/receptor pairs cannot be excluded. This may produce complicated force curves, although unambiguous ruptures are sometimes observed. In the case of the non-specific adhesion of molecules, such as fibrinogen, to a surface, it is usually difficult to identify the real events on the force curves. This can render the application of fixed rules uneasy and in addition can introduce some degree of arbitrariness if the analysis has to be performed by hand. In the present paper a computer algorithm, aimed at speeding up the processing, and at applying selection rules in a reproducible manner, is proposed. It is applied to force recordings performed at various retraction velocities, thus various loading rates. The influence on the evaluation of the rupture forces of the different parameters that can be set by the operator is discussed.

Adsorption↗

Unbinding process of adsorbed proteins under external stress studied by atomic force microscopy spectroscopy.

We report the study of the dynamics of the unbinding process under a force load f of adsorbed proteins (fibrinogen) on a solid surface (hydrophilic silica) by means of atomic force microscopy spectroscopy. By varying the loading rate r(f), defined by f = r(f) t, t being the time, we find that, as for specific interactions, the mean rupture force increases with r(f). This unbinding process is analyzed in the framework of the widely used Bell model. The typical dissociation rate at zero force entering in the model lies between 0. 02 and 0.6 s(-1). Each measured rupture is characterized by a force f(0), which appears to be quantized in integer multiples of 180-200 pN.

Fibrinogen↗

Characterization, at the bone crystal level, of the titanium-coating/bone interfacial zone.

Well integrated and clinically functional titanium dental implants retrieved in humans after 14 and 40 months of settlement were used for the characterization of the interfacial area between the plasma-sprayed coating and the surrounding mineralized bone. Electron microscopic studies were performed from undecalcified intact coating/bone interfaces. The concomitant presence of direct bone tissue apposition on the titanium coating, as well as the interposition of amorphous material along the same interfacial zones emphasizes the dynamic biologic aspect of the osseointegration process. A very striking finding of these ultrastructural and microanalytical investigations was the presence of tiny titanium grains ranging from 5 to 50 nm in diameter at the surface of bulky plasma-sprayed coating particles. High-resolution transmission electron microscopy revealed a continuity between the lattice planes of the coating material and those of the minute titanium grains; thus indicating a chemical binding. The thickness of the granular titanium layer interposed between coating particles and mineralized bone tissue ranged up to 600 nm. The observation of calcium-phosphate needle-like crystallites within the porous layer made of titanium grains indicates a bone ingrowth process, suggesting a bone-binding mechanism to the outer surface of the coated titanium implant.

Aged↗

Direct observation of the anchoring process during the adsorption of fibrinogen on a solid surface by force-spectroscopy mode atomic force microscopy.

Atomic force microscopy in a force-spectroscopy mode has been used to investigate the kinetics of the adsorption process of fibrinogen molecules on a silica surface. An original "approach/retraction" cycle of the tip/surface was used for this purpose. Fibrinogen molecules were adsorbed on the atomic force microscopy tip and were brought into contact with the silica surface for different interaction times varying from 5 to 2,000 ms. Multiple consecutive ruptures were observed. The mean number of ruptures nr per cycle increases steadily with the interaction time as well as the mean strength fr which varies from 300 pN for 5 ms to 1,400 pN for 2,000 ms. The minimal interaction time for a fibrinogen molecule to bind strongly to a silica surface during an adsorption process appears to lie between 50 and 200 ms. The histograms of the distances between two consecutive ruptures in one cycle exhibit maxima around 20-25 nm. This length is comparable to the characteristic distance between D and E globules of one fibrinogen molecule and suggests that fibrinogen molecules mainly adsorb through their D and E globules.

Fibrinogen↗

Ultrastructural features of the bone response to a plasma-sprayed hydroxyapatite coating in sheep.

The intentions of this study were to characterize the macroscopic, microscopic, and structural aspects of a plasma-sprayed implant and to thoroughly investigate bone tissue response after its implantation in sheep. Therefore, we used scanning electron microscopy, transmission electron microscopy (TEM), high-resolution TEM, X-ray diffraction, and energy-dispersive X-ray analyses. Assessment of the biomaterial prior to implantation showed a coating with irregular outlines and varying thickness, mainly consisting of hydroxyapatite (HA) covering a rough metallic implant core. Six months after insertion of the HA-coated Ti-6A1-4V implant, neither mechanical failure of the coating-substrate interface nor a significant loss of coating thickness was evident. However, an occasional lack of HA coating and phagocytosis of HA particles were noted. More generally, the implant was surrounded by well-mineralized bone investing the smallest cavities of the plasma-sprayed layer. Newly formed microcrystals with size, shape, and structure similar to those of bone apatite crystals were growing directly at the coating surface. These results suggest that the bone-bonding behavior of the considered grooved implant should provide satisfactory osseointegration and be suitable for fixed prostheses.

Animals↗

Transformation of hydroxyapatite to fluorapatite by irradiation with high-energy CO2 laser.

High-energy laser irradiation has been shown to cause crystalline transformations in apatites, which may lead to the formation of tricalcium phosphates with a resulting decrease in acid resistance. Depending on the nature and energy density of laser irradiation used, however, an increase of acid resistance of dental enamel has also been reported after laser irradiation. The aim of the present study was to investigate the phase transformation of hydroxyapatite (HA) to fluorapatite (FA) in a model system that incorporates sodium fluoride (NaF) into apatite structure by using laser irradiation. A CO2 laser was used at energy densities ranging from 21 to 500 J/cm2. Synthetic HA mixed with NaF (10:1) was the target of laser irradiation. The crystalline structures were then investigated using X-ray diffraction analysis. The results showed that a phase transformation of HA to FA could be realized, and that the threshold energy density needed was 38 J/cm2. Not only is the finding crystallographically important, but it also opens new perspectives for future research regarding the development of laser technology for clinical purposes.

Apatites↗

HRTEM study of biological crystal growth mechanisms in the vicinity of implanted synthetic hydroxyapatite crystals.

Calcium phosphates are widely used as biomaterials. Ultrastructural assessments are of the utmost importance in our understanding of interfacial phenomena. The aim of this study was to learn more about the newly formed crystal growth mechanisms. The interfaces between implanted synthetic hydroxyapatite crystals (HAS) and newly formed crystallites were thoroughly examined on a molecular level. The bone-grafting material (HAS) was implanted into two adult patients, and small biopsies were recovered 6 months after implantation. The raw biomaterial was analyzed by x-ray diffraction and high-resolution transmission electron microscopy (HRTEM). Six months after their implantation, the HAS aggregates were surrounded by a mineralized bone matrix. Tiny crystallites also filled the spaces between the HAS crystals within the aggregates. These newly formed crystallites growing at the surfaces of the implanted HAS crystals appeared to be apatitic. The crystallographic investigations of the nucleation and growing mechanisms of the newly formed crystallites were performed by HRTEM in association with computer simulation and mathematical processing of digitized images. A relationship was noted between the orientation axes of crystallites growing nearby and the zone axes of the implanted HAS, thus strongly suggesting a guiding or substratum role of the HAS particles.

Adult↗

Ultrastructural aspects of the intact titanium implant-bone interface from undecalcified ultrathin sections.

An osseointegrated oral implant with surrounding bone was used for electron microscopical analyses of the implant-bone interface. The bulk metal was removed by sawing and grinding techniques, leaving only the plasma-sprayed titanium coating anchored in mineralized bone. Ultrathin sections were realized from these reduced interface areas and underwent ultrastructural and crystallographic assessments. The microscopical observations showed that ultramicrotomy was suitable for producing such interface sections. Two different, concomitant, interfacial structures were noticed. On the one hand it was possible to observe bone crystals directly apposed on the implant surface; on the other, a granular electron-dense substance was interposed between the plasma-sprayed coating and the bone. The applied technical approach allows one to study the osseointegration process, at high resolution levels, of intact interfaces from complete osseointegrated implants.

Alloys↗