PubMed Health⌕ Search

Biomedical subjects

J Hendrick

Publications and source records attributed to J Hendrick.

7 recordsLinked to original sources

Legal aspects of clinical ethics committees.

In an increasingly litigious society where ritual demands for accountability and "taking responsibility" are now commonplace, it is not surprising that members of clinical ethics committees (CECs) are becoming more aware of their potential legal liability. Yet the vulnerability of committee members to legal action is difficult to assess with any certainty. This is because the CECs which have been set up in the UK are--if the American experience is followed--likely to vary significantly in terms of their functions, procedures, composition, structures and authority. As a consequence it is difficult to generalize about the legal implications. Nevertheless, despite these difficulties this article will outline the broad legal principles governing the potential liability of committee members. It will also consider the relationship between CECs and the courts. It begins, however, with a brief analysis of the relationship between ethics and law in committee deliberations, and in particular of the role of law and legal expertise on CECs.

Committee Membership↗

Myocardial and interstitial matrix metalloproteinase activity after acute myocardial infarction in pigs.

A structural event during the evolution of a myocardial infarction (MI) is left ventricular (LV) remodeling. The mechanisms that contribute to early changes in LV myocardial remodeling in the post-MI period remain poorly understood. Matrix metalloproteinases (MMPs) contribute to tissue remodeling in several disease states. Whether and to what degree MMP activation occurs within the myocardial interstitium after acute MI remains to be determined. Adult pigs (n = 15) were instrumented to measure regional myocardial function and interstitial MMP levels within regions served by the circumflex and left anterior descending arteries. Regional function was measured by sonomicrometry, and interstitial MMP levels were determined by selective microdialysis and zymography as well as by MMP interstitial fluorogenic activity. Measurements were performed at baseline and sequentially for up to 3 h after ligation of the obtuse marginals of the circumflex artery. Regional fractional shortening fell by over 50% in the MI region but remained unchanged in the remote region after coronary occlusion. Release of soluble MMPs, as revealed by zymographic activity of myocardial interstitial samples, increased by 2 h post-MI. The increased zymographic activity after MI was consistent with MMP-9. Myocardial interstitial MMP fluorogenic activity became detectable within the ischemic region as early as 10 min after coronary occlusion and significantly increased after 1 h post-MI. MMP fluorogenic activity remained unchanged from baseline values in the remote region. The present study demonstrated that myocardial MMP activation can occur within the MI region in the absence of reperfusion. These unique results suggest that MMP release and activation occurs within the ischemic myocardial interstitium in the early post-MI period.

Animals↗

Characterization and complementation of a Pichia stipitis mutant unable to grow on D-xylose or L-arabinose.

Pichia stipitis CBS 6054 will grow on D-xylose, D-arabinose, and L-arabinose. D-Xylose and L-arabinose are abundant in seed hulls of maize, and their utilization is important in processing grain residues. To elucidate the degradation pathway for L-arabinose, we obtained a mutant, FPL-MY30, that was unable to grow on D-xylose and L-arabinose but that could grow on D-arabinitol. Activity assays of oxidoreductase and pentulokinase enzymes involved in D-xylose, D-arabinose, and L-arabinose pathways indicated that FPL-MY30 is deficient in D-xylitol dehydrogenase (D-XDH), D- and L-arabinitol dehydrogenases, and D-ribitol dehydrogenase. Transforming FPL-MY30 with a gene for xylitol dehydrogenase (PsXYL2), which was cloned from CBS 6054 (GenBank AF127801), restored the D-XDH activity and the capacity for FPL-MY30 to grow on L-arabinose. This suggested that FPL-MY30 is critically deficient in XYL2 and that the D-xylose and L-arabinose metabolic pathways have xylitol as a common intermediate. The capacity for FPL-MY30 to grow on D-arabinitol could proceed through D-ribulose.

Arabinose↗

Cloning and disruption of the beta-isopropylmalate dehydrogenase gene (LEU2) of Pichia stipitis with URA3 and recovery of the double auxotroph.

Transformation of Pichia stipitis is required to advance genetic studies and development of xylose metabolism in this yeast. To this end, we used P. stipitis URA3 (PsURA3) to disrupt P. stipitis LEU2 in a P. stipitis ura3 mutant. A highly fermentative P. stipitis mutant (FPL-DX26) was selected for resistance to 5'-fluoroorotic acid to obtain P. stipitis FPL-UC7 (ura3-3). A URA3:lacZ "pop-out" cassette was constructed containing PsURA3 flanked by direct repeats from segments of the lacZ reading frame. The P. stipitis LEU2 gene (PsLEU2) was cloned from a P. stipitis CBS 6054 genomic library through homology to Saccharomyces cerevisiae LEU2, and a disruption cassette was constructed by replacing the PsLEU2 reading sequence with the PsURA3:lacZ cassette. FPL-UC7 (ura3-3) was transformed with the disruption cassette, and a site-specific integrant was identified by selecting for the Leu- Ura+ phenotype. The ura3 marker was recovered from this strain by plating cells onto 5'-fluoroorotate and screening for spontaneous URA3 deletion mutants. Excision of the flanked PsURA3 gene resulted in the Leu- Ura- phenotype. The double auxotrophs are stable and can be transformed at a high frequency by PsLEU2 or PsURA3 carried on autonomous-replication-sequence-based plasmids.

3-Isopropylmalate Dehydrogenase↗

Comparing no-touch and tympanic thermometer temperature recordings.

Temperature is a vital sign which can be measured using various types of clinical thermometers. Pulmonary artery temperature is considered the 'gold standard', but this measurement is not usually clinically practical. There is currently no consensus for optimal alternative site or equipment. This research compares 178 simultaneous measurements from 5 clinical areas, using two types of thermometers: tympanic and no-touch temporal. No-touch thermometers were all set to oral equivalent. Tympanic thermometers were adjusted to either oral (n=105) or core (n=73) equivalent. Maximum acceptable difference was identified as 1oC. Two data sets (oral/core; oral/oral) were analysed using Bland-Altman method on Excel programmes, comparing all thermometers and separating oral and core-equivalent tympanics. The two thermometers were found not to be equivalent. As a simple comparison between two thermometers, this research cannot identify which thermometer is more accurate.

Bias↗