PubMed Health⌕ Search

Biomedical subjects

J Heo

Publications and source records attributed to J Heo.

At least 37 records · Page 2Linked to original sources

Utility of stress single-photon emission computed tomography (SPECT) perfusion imaging in predicting outcome after coronary artery bypass grafting.

Previous studies have examined the predictors of outcome in medically treated patients with coronary artery disease (CAD). There is limited information on predictors of outcome after coronary artery bypass grafting (CABG). This study examined the predictors of outcome of 255 patients with CAD, at a mean time of 5 years after CABG for angina pectoris. The 255 patients underwent coronary angiography and stress single-photon emission computed tomography (SPECT) myocardial perfusion imaging after CABG. During a mean follow-up of 41 +/- 28 months after stress testing, there were 34 hard events (24 cardiac deaths and 10 nonfatal myocardial infarctions). The hemodynamics during stress testing, and age and gender were not predictors of events. The SPECT variables of multivessel perfusion abnormality, perfusion deficit size, and increased lung thallium uptake were predictors of death and total events by uni- and multivariate survival analysis. There were 14 events in 45 patients (31%) with multivessel abnormality and increased lung thallium uptake, 14 events in 101 patients (14%) with either multivessel abnormality or increased lung uptake, and 6 events in 109 patients (6%) with neither of these 2 variables (p = 0.0001). The annual mortality and total event rates were 7.5% and 9.5% with both variables, 3.4% and 4.3% with either variable, and 0.6% and 1.7% with neither of the variables (p = 0.01). Thus, stress SPECT perfusion imaging is useful to stratify patients after CABG into low, intermediate, and high risk groups for future cardiac events.

Adenosine↗

Prediction of outcome of patients with life-threatening ventricular arrhythmias treated with automatic implantable cardioverter-defibrillators using SPECT perfusion imaging.

BACKGROUND: In the present study, we examined the predictors of outcome of 103 patients with coronary artery disease and left ventricular dysfunction who had life-threatening ventricular arrhythmias and were treated with implantable cardioverter-defibrillators with the use of single-photon emission computed tomography (SPECT). METHODS AND RESULTS: During a mean follow-up of 29 months, there were 29 cardiac deaths. In comparison with patients who died, survivors had less diabetes mellitus (45% versus 19%, P < .007), higher left ventricular ejection fraction (23 +/- 9% versus 27 +/- 11%, P = .04), and fewer perfusion defects as determined with stress SPECT (15 +/- 5 versus 12 +/- 5, P < .004). Most of the perfusion defects were fixed, indicative of scarring; the extent of reversible defects did not differ (2 +/- 3 in survivors and 3 +/- 4 in nonsurvivors). Multivariate Cox survival analysis identified the number of fixed defects as the only independent predictor of death (chi 2 = 10, P = .002). There were six deaths among 42 patients (14%) with < 8 fixed defects compared with 23 deaths among 61 patients (38%) with > or = 8 defects (P = .005). The 4-year survival was better in patients with < 8 segmental fixed defects than in those with > or = 8 fixed defects (80% versus 36%) (chi 2 = 8, P = .005). CONCLUSIONS: The myocardial perfusion pattern is an important determinant of outcome in patients with life-threatening ventricular arrhythmias who are treated with a implantable cardioverter-defibrillator. The extent of scarring separates patients into high- and low-risk groups with a 2.7-fold difference in death rate.

Aged↗

Effect of Ca2+ channel blockers, external Ca2+ and phospholipase A2 inhibitors on t-butylhydroperoxide-induced lipid peroxidation and toxicity in rat liver slices.

OBJECTIVES: This study was undertaken to examine the effect of oxidant on lipid peroxidation and lethal cell injury in rat liver slices. METHODS: t-Butylhydroperoxide (t-BHP) was employed as a model of an oxidant. The lipid peroxidation and lethal cell injury were estimated by measuring the formation of malondialdehyde (MDA) and lactate dehydrogenase (LDH) release, respectively. RESULTS: t-BHP increased lipid peroxidation and LDH release in a dose-dependent manner over concentrations of 0.5-10 mM. t-BHP-induced lipid peroxidation was completely prevented by an antioxidant, N,N-diphenyl-p-phenylenediamine (DPPD), but LDH release was partially decreased. Both t-BHP-induced lipid peroxidation and LDH release were significantly protected by iron chelator, deferoxamine, sulfhydryl reducing agent, dithiothreitol and glutathione. Ca2+ channel blockers, verapamil, diltiazem and nifedipine exerted a significant protective effect against t-BHP-induced lipid peroxidation and LDH release. By contrast, addition of external Ca2+ chelator, ethylene glycol bis(b-aminoethyl ether)-N,N-tetraacetic acid (EGTA) did not alter t-BHP-induced lipid peroxidation, whereas t-BHP-induced lethal cell injury was significantly prevented. Phospholipase A2 (PLA2) inhibitors, mepacrine and butacaine produced a partial protective effect. CONCLUSIONS: These results suggest that t-BHP induces cell injury by lipid peroxidation-dependent and -independent mechanisms which can be partially prevented by Ca2+ channel blockers and PLA2 inhibitors.

Animals↗

Exercise-rest same-day SPECT sestamibi imaging to detect coronary artery disease.

UNLABELLED: This study examined the results of exercise-rest same-day SPECT protocol in 193 patients, of whom 132 had coronary artery disease (CAD) by angiography (> or = 50% diameter stenosis), and 61 had a low pretest probability of CAD. METHODS: The rest study was combined with first-pass radionuclide angiography using the multicrystal gamma camera in 72 patients. RESULTS: The sensitivity of SPECT was 76% (25/33 patients) in patients with one-vessel, 84% in patients with two-vessel (38/45) and 98% in patients with three-vessel CAD (53/54) (P = 0.01 versus one- or two-vessel CAD). The sensitivity of SPECT in patients with CAD was higher than ST depression (88% versus 28%, P = 0.001). The exercise was submaximal in 53 patients (40%). The perfusion defects were reversible (complete or partial) in 80 patients and fixed in 36 patients. The left ventricular ejection fraction was 50 +/- 12% in patients with reversible defects (n = 44) and 39 +/- 9% in patients with fixed defects (n:19) (P = 0.0004). The normalcy rate in subjects with a low pretest probability of CAD was 95% (53 of 61 subjects). CONCLUSION: The exercise-rest same-day sestamibi protocol provides high diagnostic accuracy for CAD detection. The protocol may eliminate the need for rest studies in patients with normal exercise images, help improve laboratory throughput and lower costs.

Adult↗

Dynamic planar myocardial perfusion imaging in patients with one-vessel disease with intracoronary injection of technetium 99m teboroxime during papaverine-induced coronary hyperemia.

This study examined the imaging results and kinetics of technetium 99m teboroxime after its intracoronary injection during papaverine-induced coronary hyperemia in patients with one-vessel disease before and after coronary angioplasty. Thirteen patients with > or = 90% diameter stenosis of either the left anterior descending or the left circumflex coronary artery were included. Two patients were excluded because of ventricular tachycardia during papaverine injection in one patient and unsuccessful angioplasty in the second patient. One mCi of technetium 99m teboroxime was injected into the left main coronary artery during coronary hyperemia induced by intracoronary injection of papaverine. Dynamic acquisition in a frame mode (20 sec/frame) was performed for 5 minutes in the left anterior oblique projection with a multicrystal gamma camera before and after successful angioplasty. Ischemic:normal count ratio increased from 0.75 +/- 0.4 before to 1.00 +/- 0.50 after angioplasty (p < 0.1). The T 1/2 of teboroxime was 6.5 +/- 1.5 min in the normal zone and 7.2 +/- 1.9 min in the ischemic zone (p, NS). Perfusion defects were visible in the territory of the stenosed coronary artery in 9 of 11 patients before angioplasty and in 7 of 11 patients after angioplasty. The image quality was excellent in all studies. Thus this study shows that performing dynamic imaging with intracoronary injection of technetium 99m teboroxime is feasible. This technique may be useful to study the impact of angioplasty on coronary flow and tracer kinetics.

Aged↗

Myocardial viability: methods of assessment and clinical relevance.

Myocardial hibernation is hypoperfused dysfunctional myocardium that has the potential to recover function after coronary revascularization. Although recovery of regional function after revascularization is the gold standard for assessing the diagnostic accuracy of various techniques, improvements of EF, symptoms, and survival are fundamental end points. Despite important differences in the markers of viability by positron-emission tomography, single-photon emission tomography, two-dimensional echocardiography, and magnetic resonance imaging, their positive and negative predictive values in nonrandomized studies are fairly comparable. Assessment of myocardial viability may be clinically important in many patients but especially in those with EF < 30% and congestive heart failure. The degree of improvement in EF after coronary revascularization depends on the extent of hibernation, the suitability of coronary structure for revascularization, the lack of perioperative infarction, the completeness of revascularization, and the long-term patency of grafts.

Cardiac Catheterization↗

Early postoperative rise in defibrillation threshold in patients with nonthoracotomy defibrillation lead systems: attenuation with biphasic shock waveforms.

INTRODUCTION: In patients with non-thoracotomy defibrillation lead (NTL) systems coupled with monophasic shock waveforms, the defibrillation threshold (DFT) rises early after implantation. There is little information regarding features predictive of the DFT rise, or DFT changes early after implantation of NTL systems coupled with biphasic shock waveforms. METHODS AND RESULTS: DFT measurements were performed serially at implantation, prior to hospital discharge (mean 4 +/- 3 days), and at follow-up (mean 49 +/- 22 days) in 146 patients with an NTL system. Factors were assessed for association with a "clinically important" early postimplantation DFT rise, defined as a rise of > or = 2 energy steps (2 to 4 J per step; > or = 5 J total). A clinically important early postimplantation DFT rise occurred in 48 patients (33%). Univariate predictors of the rise included the monophasic shock waveform, the Medtronic Transvene lead system, the presence of a subcutaneous defibrillation patch, and the number of shocks delivered during the implantation procedure. However, the only independent predictor of a clinically important DFT rise was the monophasic shock waveform (F = 18, P < 0.001). For the monophasic patient group (n = 79), the incidence of a DFT rise was 53% (n = 42). For the biphasic patient group (n = 67), the incidence of a DFT rise was 9% (n = 6). The clinical characteristics of the monophasic and biphasic groups were not significantly different, nor were their DFTs at implantation. Among a subgroup of 18 consecutive patients who underwent serial DFT testing utilizing both monophasic and biphasic waveforms, the incidence of a clinically important DFT rise with monophasic (n = 9,50%) was higher than with biphasic shocks (n = 3,17%; P = 0.05). CONCLUSION: NTL systems coupled with biphasic shock waveforms have an attenuated incidence of a clinically important DFT rise early after implantation, relative to patients with NTL systems coupled to monophasic waveforms.

Analysis of Variance↗

Circadian variation of ventricular arrhythmia recurrences after cardioverter-defibrillator implantation in patients with healed myocardial infarcts.

Past studies using Holter monitoring and retrospective reviews of death certificates have documented peak occurrence of sudden death and nonsustained ventricular tachycardia (VT) in the morning hours. We used the Ventritex Cadence device (Ventritex, Sunnyvale, California) which documents the date and time of all stored arrhythmias leading to device therapy to evaluate the circadian pattern of sustained ventricular arrhythmia recurrence. Mean follow-up after defibrillator implantation was 628 +/- 285 days. All 390 patients had at least 1 episode (range 1 to 43) of sustained VT documented from analysis of the stored electrograms associated with an arrhythmia event. Stored electrograms were available for review and analysis in 3,041 device detections; 349 stored events were excluded because they did not fulfill the diagnostic criteria for VT or failed to document the onset of the ventricular arrhythmia at the beginning of the recorded event of the arrhythmia episode. Criteria for the diagnosis of VT or ventricular fibrillation were met in 2,692 arrhythmia episodes occurring in 390 patients. There was circadian variation for ventricular arrhythmia recurrence for the whole patient group with the data fit to the sinusoidal density function: f(t) = 126 - 51 x cos (-57 + 2 pi t/24) - 25 x sin (63 + 2 pi t/12) (p < 0.0001). Ventricular arrhythmia occurrence rate was lowest between 2:00 and 3:00 A.M., and highest between 10:00 and 11:00 A.M. In addition, the same circadian pattern was demonstrated regardless of patient age, gender, left ventricular ejection fraction (< 35% or > or = 35%), and VT cycle length (< 300 or > or = 300 ms).(ABSTRACT TRUNCATED AT 250 WORDS)

Age Factors↗

Prognostic value of rest-redistribution tomographic thallium-201 imaging in ischemic cardiomyopathy.

The relation between the presence of viable myocardium by rest-redistribution thallium imaging and prognosis is not well defined. This study examined the prognostic value of rest-redistribution single-photon emission computed tomographic imaging with thallium-201 in patients with coronary artery disease (CAD) and left ventricular (LV) dysfunction. Patients were divided into 2 groups: group 1 patients (n = 47) were treated medically and group 2 patients (n = 38) underwent coronary revascularization. The 2 groups were comparable in the extent of CAD and in LV ejection fraction. Thallium images showed normal tracer uptake in 1 group 1 and 3 group 2 patients, fixed defects in 26 group 1 and 18 group 2 patients, and both reversible and fixed defects in 20 group 1 and 17 group 2 patients (p = NS). Based on analysis of 20 segments/patient, reversible defects were seen in 4 +/- 4 segments/patient in group 1 and 5 +/- 5 segments/patient in group 2 (p = NS). Viable myocardium (defined as normal tracer uptake, reversible defects, or mild fixed defects) was seen in 14 +/- 4 segments/patient in group 1 and 15 +/- 5 segments/patient in group 2 (p = NS). During a mean follow-up of 31 months, there were 16 group 1 (34%) and 6 group 2 (16%) deaths. The annual mortality rate was 13% in group 1 and 6% in group 2. Actuarial survival analysis showed better survival in group 2 than in group 1 (p = 0.056). Thus, viable myocardium in patients with CAD and LV dysfunction is associated with poor prognosis with medical therapy. Coronary revascularization improves prognosis.

Actuarial Analysis↗

Optimizing patient selection for coronary angiography.

Indications for coronary angiography depend on the patient's clinical presentation. In many situations, coronary angiography may be reserved for patients who have severe symptoms, despite optimal medical therapy, and for patients defined to be at high risk, based on noninvasive stress testing. These patient groups include those with chest pain syndromes, postmyocardial infarction, unstable angina, postcoronary revascularization, severe left ventricular dysfunction, survivors of sudden cardiac death, and those about to undergo major vascular noncardiac surgery.

Angina Pectoris↗

Comparison of thallium-201 single-photon emission computed tomography and electrocardiographic response during exercise in patients with normal rest electrocardiographic results.

OBJECTIVES: This study compared the diagnostic accuracy of exercise thallium-201 single-photon emission computed tomography (SPECT) with the exercise electrocardiographic (ECG) response in patients with normal baseline ECG results. BACKGROUND: Previous studies comparing exercise thallium imaging with exercise electrocardiography have included patients with abnormal rest ECG results that may have biased the results in favor of thallium imaging. METHODS: Of 321 patients with a pretest likelihood of coronary artery disease of 70 +/- 29% (mean +/- SD) who underwent exercise stress testing and coronary angiography, 68 had no coronary artery disease; 94 had one-vessel disease; 79 had two-vessel disease; and 80 had three-vessel or left main coronary artery disease. RESULTS: The diagnostic accuracy of SPECT was higher than that of the ECG response (79% vs. 49%, p < 0.0001). Patients with extensive (left main or three-vessel) coronary artery disease were older and had a lower work load, lower heart rate, greater ST segment depression and more extensive perfusion abnormalities than patients with no disease or one- or two-vessel disease. Multivariate discriminant analysis of exercise and thallium variables identified multivessel thallium abnormalities (F = 35), exercise heart rate (F = 18) and extent of ST segment depression (F = 6) as independent predictors of extensive disease. Of the 80 patients with left main or three-vessel disease, 37 (46%) had > or = 2-mm ST segment depression, 44 (55%) had multivessel SPECT abnormalities, and 61 (76%) had either > or = 2-mm ST depression or multivessel SPECT abnormalities (p = 0.0005 vs. the ECG response; p = 0.01 vs. SPECT). CONCLUSIONS: In patients with an intermediate to high pretest probability of coronary artery disease and normal baseline ECG results, SPECT is superior to the ECG response in detecting coronary disease. Further, SPECT provides incremental power in identifying patients with extensive (left main or three-vessel) coronary disease.

Aged↗