Dose-controlled exposure of A549 epithelial cells at the air-liquid interface to airborne ultrafine carbonaceous particles.

The geometry of commercially available perfusion chambers designed for harbouring three membrane-based cell cultures was modified for reliable and dose-controlled air-liquid interface (ALI) exposures. Confluent A549 epithelial cells grown on membranes were integrated in the chamber system and supplied with medium from the chamber bottom. Cell viability was not impaired by the conditions of ALI exposure without particles. Expression of the inflammatory cytokines interleukin 6 and interleukin 8 by A549 cells during ALI exposure to filtered air for 6h and subsequent stimulation with tumor necrosis factor was not altered compared to submersed controls, indicating that the cells maintained their functional integrity. Ultrafine carbonaceous model particles with a count median mobility diameter of about 95+/-5 nm were produced by spark discharge at a stable concentration of about 2 x 10(6) cm(-3) and continuously monitored for accurate determination of the exposure dose. Delivery to the ALI exposure system yielded a homogeneous particle deposition over the membranes with a deposition efficiency of 2%. Mid dose exposure of A549 cells to this aerosol for 6h yielded a total particle deposition of (2.6+/-0.4) x 10(8) cm(-2) corresponding to (87+/-23) ng cm(-2). The 2.7-fold (p < or = 0.05) increased transcription of heme oxygenase-1 indicated a sensitive antioxidant and stress response, while cell viability did not reveal a toxic mechanism.

Aerosols↗

Distribution pattern of inhaled ultrafine gold particles in the rat lung.

The role of alveolar macrophages in the fate of ultrafine particles in the lung was investigated. Male Wistar-Kyoto rats were exposed to ultrafine gold particles, generated by a spark generator, for 6 h at a concentration of 88 microg/m3 (4 x 10(6)/cm3, 16 nm modal mobility diameter). Up to 7 days, the animals were serially sacrificed, and lavaged cells and lung tissues were examined by transmission electron microscopy. The gold concentration/content in the lung, lavage fluid, and blood was estimated by inductively coupled plasma-mass spectrometry. Gold particles used were spherical and electron dense with diameters of 5-8 nm. The particles were individual or slightly agglomerated. By inductively coupled plasma-mass spectrometry analysis of the lung, 1945 +/- 57 ng (mean +/- SD) and 1512 +/- 184 ng of gold were detected on day 0 and on day 7, respectively, indicating that a large portion of the deposited gold particles was retained in the lung tissue. In the lavage fluid, 573 +/- 67 ng and 96 +/- 29 ng were found on day 0 and day 7, respectively, which means that 29% and 6% of the retained gold particles were lavageable on these days. A low but significant increase of gold (0.03 to 0.06% of lung concentration) was found in the blood. Small vesicles containing gold particles were found in the cytoplasm of alveolar macrophages. In the alveolar septum, the gold particles were enclosed in vesicles observed in the cytoplasm of alveolar type I epithelial cells. These results indicate that inhaled ultrafine gold particles in alveolar macrophages and type I epithelial cells are processed by endocytotic pathways, though the uptake of the gold particles by alveolar macrophages is limited. To a low degree, systemic particle translocation took place.

Animals↗

Long-term clearance kinetics of inhaled ultrafine insoluble iridium particles from the rat lung, including transient translocation into secondary organs.

Recently it was speculated that ultrafine particles (UFP) may translocate from deposition sites in the lungs to systemic circulation and whether long-term clearance differs between ultrafine and micrometer-sized particles. We have studied lung retention and clearance kinetics in 12 healthy male adult WKY rats up to 6 mo after an inhalation of (192)Ir-radiolabeled, insoluble, ultrafine 15- to 20-nm iridium particles. Whole-body retention was followed by external gamma counting, and particle clearance kinetics were determined by excretion radioanalysis. Four rats each were sacrificed after 3 wk and 2 and 6 mo; all organs as well as tissues and the carcass were radioanalyzed to balance the entire deposited radioactivity of the particles. The most prominent fraction was retained in the lungs at each time point of sacrifice (26%, 15%, 6%, respectively), and clearance out of the body was solely via excretion. Extrapulmonary particle uptake did not continue to increase but decreased with time in liver, spleen, heart, and brain when compared to previous data obtained during the first 7 days after inhalation (Kreyling et al., 2002). UFP long-term lung retention derived from whole-body measurements was comparable to previously reported data using insoluble micrometer-sized particles (Bellmann et al., 1994; Lehnert et al., 1989). In addition, differential analysis including daily excretion data revealed a pattern of fractional particle clearance rate of the ultrafine iridium particles similar to that of micrometer-sized particles reported by Snipes et al. (1983) and Bailey et al. (1985).

Administration, Inhalation↗

Fate and toxic effects of inhaled ultrafine cadmium oxide particles in the rat lung.

Female Fischer 344 rats were exposed to ultrafine cadmium oxide particles, generated by spark discharging, for 6 h at a concentration of 70 microg Cd/m(3) (1 x 10(6)/cm(3)) (40 nm modal diameter). Lung morphology and quantification of Cd content/concentration by inductively coupled plasma (ICP)-mass spectrometry were performed on days 0, 1, 4, and 7 after exposure. Cd content in the lung on day 0 was 0.53 +/- 0.12 microg/lung, corresponding to 19% of the estimated total inhaled cumulative dose, and the amount remained constant throughout the study. In the liver no significant increase of Cd content was found up to 4 days. A slight but statistically significant increase was observed in the liver on day 7. We found neither exposure-related morphological changes of lungs nor inflammatory responses in lavaged cells. Another group of rats were exposed to a higher concentration of ultrafine CdO particles (550 microg Cd/m(3) for 6 h, 51 nm modal diameter). The rats were sacrificed immediately and 1 day after exposure. The lavage study performed on day 0 showed an increase in the percentage of neutrophils. Multifocal alveolar inflammation was seen histologically on day 0 and day 1. Although the Cd content in the lung was comparable between day 0 and day 1 (3.9 microg/lung), significant elevation of Cd levels in the liver and kidneys was observed on both days. Two of 4 rats examined on day 0 showed elevation of blood cadmium, indicating systemic translocation of a fraction of deposited Cd from the lung in this group. These results and comparison with reported data using fine CdO particles indicate that inhalation of ultrafine CdO particles results in efficient deposition in the rat lung. With regard to the deposition dose, adverse health effects of ultrafine CdO and fine CdO appear to be comparable. Apparent systemic translocation of Cd took place only in animals exposed to a high concentration that induced lung injury.

Animals↗

Effects of inhaled CdO particles on the sphingolipid synthesis of rat lungs.

Surfactant lipids of the alveolar space protect the lung from various environmental stimuli. We investigated the influence of ultrafine (UF) CdO particles inhalation on two key enzymes involved in lung sphingolipid metabolism, serine palmitoyltransferase (SPT), and sphingomyelinase (SMase). Rats inhaled either 0.63 mg UF-CdO/m(3) for 6 h (group 1), or 1.08 mg UF-CdO/m(3) 12 h/day for 10 days (group 2). Two corresponding control groups inhaled filtered clean air. Additional rats intratracheally instilled with lipopolysaccharide (LPS) were used as positive controls. Semiquantitative reverse-transcription polymerase chain reaction (RT-PCR) of lung tissue showed a significant increase in the level of SPT mRNA (LCB2 subunit) expression in group 2 compared to the corresponding controls (p <.01). Group 1 and LPS were not statistically different from control. No alteration in the mRNA level of SMase was detected in any exposure group. The immunohistochemical analysis showed that SPT (LCB2 subunit) localization was stronger in the alveolar type II cells of group 2 lungs compared to the corresponding controls. These results were correlated with alterations in BALF cellular and biochemical parameters and lung morphology. Since SPT is the key enzyme for de novo sphingolipid synthesis in lung surfactant and SMase is responsible for sphingomyelin catabolism, we can postulate that high-dose UF-CdO exposure for 10 days induces an increase in sphingolipid synthesis in the type II cells of rat lungs that would not be promptly followed by its degradation.

Acyltransferases↗

Respiratory mechanics in mice: strain and sex specific differences.

To assess the contribution of genetic background to respiratory mechanics, we developed a ventilator unit to measure lung function parameters in the mouse. We studied two commonly used inbred mice strains originating from Mus musculus domesticus (C57BL/6 and C3HeB/FeJ) and a third strain derived from Mus musculus molossinus [Japanese fancy mouse 1 (JF1)]. The ventilator allows for accurate performance of the different breathing manoeuvres required for measuring in- and expiratory reserve capacity, quasi-static and dynamic compliance, and airway resistance. In combination with a mass spectrometer for monitoring gas concentrations, single-breath manoeuvres were performed and He-expirograms obtained, from which dead space volume and slope of phase III were determined. From each strain and each sex, 10, 2-month old animals were studied immediately after being killed by an intraperitoneal overdose of xylazine and ketamine. C3HeB/FeJ and C57BL/6 exhibited comparable lung volumes. In male C3HeB/FeJ mice, e.g. vital capacity (VC) was 1072 +/- 79 microL, inspiratory reserve capacity 782 +/- 88 microL, and dead space volume at total lung inflation 216 +/- 18 microL. Lung volumes of JF1 were significantly lower (e.g. VC 611 +/- 53 microL, P < 0.01) even when normalized to body weight. In all three strains, specific lung volumes were significantly higher in females than in males, possibly explained by a higher oxygen demand during pregnancy and lactation, both of which fill most of their life times. Static compliance in C3HeB/FeJ was 64.3 +/- 5.4 microL cmH2O-1. It was smaller in C57BL/6 and JF1 mice, even when related to the lung volume. Analysis of the degree of genetic vs. non-genetic components of the phenotypic variation revealed that at least 80% of the total variation of lung volumes and static compliance in the mixed population is attributable to genetic differences between individuals. These differences will be verified in further studies by segregation and genetic linkage analysis.

Animals↗

[Pneumological diagnostics by means of models aerosols. IV. Clearance of aerosol particles from the pulmonary alveoli. Foundations and first clinical results].

The elimination of deposited particles (inorganic and organic particles, bacteria, viruses) from the periphery of the human lung (alveolar clearance) implies phagocytosis by alveolar macrophages, intracellular digestion, migration and translocation. Alveolar clearance of poorly soluble particles happens very slowly and primarily depends on the function of alveolar macrophages. In humans, the transport of particles to the bronchial tree is of secondary relevance, suggesting that the elimination of particles primarily depends on digestion (dissolution) processes within macrophages. The dissolved material is excreted via urine, if there is no further metabolization within the body. The pathophysiology of the alveolar clearance mechanisms in the human lung can be studied by a magnetic tracer technique (magnetopneumography). Ferromagnetic magnetite test-particles are deposited in the periphery of the lung by controlled inhalation. After magnetization and particle alignment in a strong external magnetic field pulse, the amount of retained particles can be detected by a sensitive magnetic field sensor (SQUID, superconducting quantum interference device). Long lasting cigarette smoking and chronic lung inflammations (sarcoidosis, interstitial lung fibrosis) induce a significant impairment of alveolar clearance capacity, while patients with chronic bronchitis show only a moderate impairment of alveolar clearance.

Aerosols↗

Increased sputum IL-8 and IL-5 in asymptomatic nonspecific airway hyperresponsiveness.

Since asymptomatic, nonspecific airway hyperresponsiveness (BHR) may be due to an enhanced local inflammatory response, we studied molecular markers of inflammation in induced sputum from subjects with asymptomatic BHR (n = 14) compared with control subjects (n = 13) and patients with chronic obstructive pulmonary disease (COPD) (n = 10). Pulmonary lung function parameters were measured by spirometry and body plethysmography. Hyperresponsiveness was defined based on histamine challenge. Induced sputum samples were collected and the solid phase was isolated and analyzed for leukocyte numbers and differential and for cytokines (ELISA). IL-8 was 2.4-fold increased (p = 0.036) in the sputum of subjects with asymptomatic BHR (24.8 +/- 22.0 ng/mL; +/- SD) and 11.2-fold enhanced in patients with COPD (117.8 +/- 106.3 ng/mL) as compared with control subjects (10.5 +/- 7.7 ng/mL). In control subjects, no IL-5 was measured, however, sputum of those with asymptomatic BHR contained IL-5 at 0.044 +/- 0.090 ng/mL fluid and COPD patients at 1.00 +/- 2.01 ng/mL. GM-CSF could not be detected in sputum samples of any subjects investigated. Number of total leukocytes was higher in those with asymptomatic BHR and COPD (with BHR: 9.4 +/- 10.8 x 10(5); COPD: 83.5 +/- 182.5 x 10(5)) compared with persons without BHR (2.9 +/- 3.4 x 10(5)). PMN were increased in patients with asymptomatic BHR (4.1 +/- 5.3 x 10(5)) (38.8 +/- 24.7%) and COPD (32.9 +/- 71.0 x 10(5)) (75.4 +/- 18.6%) compared with controls (0.7 +/- 0.9 x 10(5)) (25.8 +/- 25.7%). In contrast to PMN counts in those with asymptomatic BHR (0.06 +/- 0.11 x 10(5)) (1.5 +/- 3.7%), eosinophil counts were only slightly increased compared with control subjects (0.01 +/- 0.02 x 10(5)) (0.6 +/- 0.9%). This study supports the hypothesis that BHR in asymptomatic people is associated with airway inflammation that may predispose to development of chronic diseases such as COPD.

Adult↗

[Measurement of the Fowler dead space in patients with pulmonary emphysema using C18O2].

In patients with lung emphysema, changes in lung volumes as well as changes in airway resistance are well known. The change in airway resistance is caused by obstruction of central airways, which is supposed to reduce the respiratory dead space. Until now, it was not possible to measure the respiratory dead space in patients with lung emphysema using the method of Fowler [2], because in this method distinction of the three phases of an inert gas expirogram is essential. While this distinction is easy in healthy subjects (fig. 1; expirogram 3), the separation of the three phases in patients with lung emphysema is not possible due to gradual transition of phase II into phase III in these patients (fig. 1; expirogram 2). The use of C18O2 as tracer gas allows to separate phase II and phase III even if the patients have severe emphysema (fig. 1; expirogram 1). CO2 labeled with the stable oxygen isotope 18O (C18O2) is completely taken up in the gas exchanging region of the lung, but not from the conducting airways. Therefore C18O2 is only expired from the dead space of the lung, but not from the alveolar region. Hence, C18O2 allows exact measurement of the respiratory dead space in patients with lung emphysema. 21 healthy nonsmoking subjects and 29 patients with clinical signs of lung emphysema participated in this study. There was a good correlation between respiratory dead space, measured by the use of Ar-gas and C18O2-gas in healthy subjects (fig. 2). This indicates, that the use of C18O2 is a valid method to measure the functional dead space. As expected, there was also a correlation between the airway resistance and respiratory dead space in patients with lung emphysema (fig. 3), but not in healty subjects. There was no significant difference of the mean values of the respiratory dead space between these two groups (223 +/- 43 ml in healthy subjects vs. 227 +/- 52 ml in patients), even though there were large differences in airway resistance (0.20 +/- 0.10 kPa/l/s vs. 0.49 +/- 0.27 kPa/l/s). This may be due to a loss of alveolar function in the area of the terminal bronchioli, which is typical for emphysematous patients. This entails a shift of functional dead space towards lung periphery and therefore causes an increase of the volume of functional dead space. But this enlargement may be compensated by the volume reduction, caused by the airway obstruction. Hence, these two oppositional mechanisms may result in only minimal change of dead space volume.

Adult↗

Comparison of clearance of particles inhaled with bolus and extremely slow inhalation techniques.

Ten healthy nonsmokers inhaled 6-microm (aerodynamic diameter) Teflon particles labelled with 111In twice, once with the shallow bolus technique (volumetic lung depth 76+/-20 mL ([+/- SD]) and once with the extremely slow inhalation technique (0.05 L/s). The radioactivity in the lungs was measured at 1 and 24 hours as well as at 1, 2, and 3 weeks after both inhalations. The 24-hour lung retention a percentage of lung deposition was significantly lower for the bolus inhalation, 46%+/-9% (+/- SD) than for the extremely slow inhalation, 56%+/-11%. The retention after 21 days as a percentage of the 24-hour retention was 55%+/-9% for the shallow bolus inhalation and 56%+/-10% for the extremely slow inhalation. Also within the subjects, clearance was similar for the 2 modes of inhalation. Deposition of particles inhaled with the 2 modes of inhalation was calculated with 2 model, one being based on Monte (Carlo particle transport together with an asymmetric lung model. Deposition predicted with this model agreed well with the experimental data under the assumption that there are large retained fractions only in small ciliated airways (bronchioli) and not in large ones. For the bolus inhalation, the model predicted 43% to 50% deposition in the bronchial (BB) region of initial lung deposition, 33% to 38% in the bronchiolar (bb) region, and 16% to 22% in the alveolar region. For the extremely slow inhalation, the model predicted 31% to 34% deposition in the BB region, 45% to 47% in the bb region, and 21% to 22% in the alveolar region. In addition, it predicted about the same ratio between bb and alveolar depositions for the 2 modes of inhalation. Thus, both the experimental and theoretical data indicate that the shallow bolus particles to a considerable extent reach both the bb and the alveolar regions and that they do that at about the same extent as the particles inhaled extremely slow. This conclusion is concerning the experimental data based on the assumption that there are no large retained fractions in the BB region. Another interpretation of the similar clearance for the two modes of inhalation is that there are large retained fractions in both the BB and the bb regions and that individual charactristics of clearance of these fractions are of importance rather than the site of deposition.

Administration, Inhalation↗

Impulse oscillometry in healthy nonsmokers and asymptomatic smokers: effects of bronchial challenge with methacholine.

The clinical application of respiratory impedance measurements by oscillation techniques for monitoring bronchial challenge testing is hampered by the fact that data in healthy nonsmokers and asymptomatic smokers are very limited. The objective of this study was to analyze the changes in impedance to a methacholine provocation test in healthy nonsmokers and asymptomatic smokers, and to investigate whether smokers show a different response compared to nonsmokers. The response to methacholine challenge was assessed by impulse oscillometry (IOS) (resistance R and reactance X at 5, 10, 15, 20, 25, and 35 Hz) and spirometry (FEV1, MEF50) in 105 healthy subjects (55 nonsmokers: "NS"; 50 asymptomatic smokers: "S") in whom the provocation dose of 2.44 mg methacholine did not result in a fall of FEV1 below 20% predicted of the baseline value. The baseline reactance X values of S were significantly lower compared to NS from 10 to 35 Hz (p < or = 0.01), whereas S and NS did not differ in resistance R over the whole frequency spectrum from 5 to 35 Hz. S showed a significantly higher mean baseline resonant frequency X(f0); i.e., the frequency at which inertial forces are equal and opposite to elastic forces, compared to NS (NS: X(fo) = 10.8+/-2.9 Hz; S = 12.6+/-4.0 Hz, p = 0.01). In both groups methacholine challenge resulted in an increase in R (f) especially at 5 and 10 Hz, and a marked decrease in X(f) over the whole frequency spectrum. In S a significantly higher decrease of postchallenge X5Hz and X10Hz was measured compared to NS (NS: deltaX(5Hz) = -0.044+/-0.003; S: deltaX(5HZ) = -0.083+/-0.013; p = 0.0017. NS: deltaX(10Hz) = -0.050+/-0.001; S: deltaX(10Hz) = -0.082+/-0.017; p = 0.008). R and X at low frequencies showed a three to four times higher postchallenge reaction compared to FEV1. Pre- and postchallenge FEV1 did not correlate with resistance R (f) and reactance X(f) over the whole frequency spectrum. In S perchallenge X(f) values from 10 to 35 HZ were significantly lower, and postchallenge decrease of X5Hz and X10Hz values were significantly higher compared to that of NS, whereas pre- and postchallenge R(f) values were similar in both groups. These results can be explained by changes in the elastic properties of the lung induced by a diffuse subclinical respiratory bronchiolitis.

Adult↗

Pulmonary and systemic distribution of inhaled ultrafine silver particles in rats.

The cardiovascular system is currently considered a target for particulate matter, especially for ultrafine particles. In addition to autonomic or cytokine mediated effects, the direct interaction of inhaled materials with the target tissue must be examined to understand the underlying mechanisms. In the first approach, pulmonary and systemic distribution of inhaled ultrafine elemental silver (EAg) particles was investigated on the basis of morphology and inductively coupled plasma mass spectrometry (ICP-MS) analysis. Rats were exposed for 6 hr at a concentration of 133 microg EAg m(3) (3 x 10(6) cm(3), 15 nm modal diameter) and were sacrificed on days 0, 1, 4, and 7. ICP-MS analysis showed that 1.7 microg Ag was found in the lungs immediately after the end of exposure. Amounts of Ag in the lungs decreased rapidly with time, and by day 7 only 4% of the initial burden remained. In the blood, significant amounts of Ag were detected on day 0 and thereafter decreased rapidly. In the liver, kidney, spleen, brain, and heart, low concentrations of Ag were observed. Nasal cavities, especially the posterior portion, and lung-associated lymph nodes showed relatively high concentrations of Ag. For comparison, rats received by intratracheal instillation either 150 microL aqueous solution of 7 microg silver nitrate (AgNO(3) (4.4 microg Ag) or 150 microL aqueous suspension of 50 microg agglomerated ultrafine EAg particles. A portion of the agglomerates remained undissolved in the alveolar macrophages and in the septum for at least 7 days. In contrast, rapid clearance of instilled water-soluble AgNO(3) from the lung was observed. These findings show that although instilled agglomerates of ultrafine EAg particles were retained in the lung, Ag was rapidly cleared from the lung after inhalation of ultrafine EAg particles, as well as after instillation of AgNO(3), and entered systemic pathways.

Administration, Inhalation↗

Agglomerates of ultrafine particles of elemental carbon and TiO2 induce generation of lipid mediators in alveolar macrophages.

Agglomerates of ultrafine particles (AUFPs) may cause adverse health effects because of their large surface area. To evaluate physiologic responses of immune cells, we studied whether agglomerates of 77-nm elemental carbon [(EC); specific surface area 750 m2/g] and 21 nm titanium dioxide (TiO(2) particles (specific surface area 50 m(2)/g) affect the release of lipid mediators by alveolar macrophages (AMs). After 60-min incubation with 1 microg/mL AUFP-EC (corresponding to 7.5 cm(2) particle surface area), canine AMs (1 x 10(6) cells/mL) released arachidonic acid (AA) and the cyclooxygenase (COX) products prostaglandin E(2) (PGE(2), thromboxane B(2), and 12-hydroxyheptadecatrienoic acid but not 5-lipoxygenase (5-LO) products. AUFP-TiO(2) with a 10-fold higher mass (10 microg/mL) than AUFP-EC, but a similar particle surface area (5 cm(2) also induced AMs to release AA and COX products. Agglomerates of 250 nm TiO(2) particles (specific surface area 6.5 m(2)/g) at 100 microg/mL mass concentration (particle surface area 6.5 cm(2) showed the same response. Interestingly, 75 cm(2)/mL surface area of AUFP-EC and 16 cm(2)/mL surface area of AUFP-TiO(2) additionally induced the release of the 5-LO products leukotriene B(4) and 5-hydroxyeicosatetraenoic acid. Respiratory burst activity of stimulated canine neutrophils was partially suppressed by supernatants of AMs treated with various mass concentrations of the three types of particles. Inhibition of neutrophil activity was abolished by supernatants of AMs treated with COX inhibitors prior to AUFP-incubation. This indicates that anti-inflammatory properties of PGE(2) dominate the overall response of lipid mediators released by AUFP-affected AMs. In conclusion, our data indicate that surface area rather than mass concentration determines the effect of AUFPs, and that activation of phospholipase A(subscript)2(/subscript) and COX pathway occurs at a lower particle surface area than that of 5-LO-pathway. We hypothesize a protective role of PGE(2) in downregulating potential inflammatory reactions induced by ultrafine particles.

Air Pollutants↗

All trans-retinoic acid selectively down-regulates matrix metalloproteinase-9 (MMP-9) and up-regulates tissue inhibitor of metalloproteinase-1 (TIMP-1) in human bronchoalveolar lavage cells.

BACKGROUND: The balance between proteinases and antiproteinases plays an important role in tissue destruction and remodelling. In chronic obstructive pulmonary disease (COPD) and emphysema, an imbalance between matrix metalloproteinases (MMPs) and inhibitors of tissue metalloproteinase (TIMPs) has been reported. Alveolar macrophages are considered to be the main source of MMPs. We therefore have analyzed the effects of free and liposomal all trans-retinoic acid (ATRA) on the expression of MMP-9 and TIMP-1 in bronchoalveolar lavage (BAL) cells from patients with COPD and patients with other lung diseases. MATERIAL AND METHODS: BAL cells were incubated 1-3 day with either liposomal or free ATRA. Supernatants were tested for MMP-9 and TIMP-1 protein in specific ELISA systems; mRNA analysis was performed by semi-quantitative RT-PCR and by quantitative LightCycler PCR. RESULTS: We demonstrate that either liposomal or free ATRA selectively down-regulates MMP-9 and up-regulates TIMP-1. At the protein level, MMP-9 is decreased 3-fold and TIMP-1 is increased 3.5-fold compared to the base line with empty liposomes or untreated cells. The ratio of MMP-9 and its inhibitor TIMP-1, which may be crucial to the overall proteolytic potential decreased by factor 8. That this countercurrent effect of ATRA is not due to an altered protein stability but to transcriptional regulation could be demonstrated by RT-PCR. Quantitative LightCycler analysis revealed a 2.5-fold decrease of MMP-9 mRNA and a 4.5 fold increase of TIMP- 1 mRNA. CONCLUSIONS: These data suggest that ATRA treatment via its impact on the proteinase/antiproteinase ratio may become a new therapeutic strategy for patients with inflammatory destructive lung diseases.

Antineoplastic Agents↗