The use of remifentanil for intubation in paediatric patients during sevoflurane anaesthesia guided by Bispectral Index (BIS) monitoring.

We studied the intubating conditions, haemodynamic and endocrine changes following tracheal intubation during sevoflurane anaesthesia guided by Bispectral Index (BIS) monitoring in 40 children who received either remifentanil 1 microg.kg-1 (group R) or saline 1 ml.kg-1 (group S). Acceptable intubating conditions were found in all patients in group R (n = 20), compared to only 12 patients in group S (p = 0.002). There were no intergroup differences in heart rate, systolic blood pressure and plasma concentrations of epinephrine and norepinephrine at any time point and changes in haemodynamic variables throughout the study period were moderate. Titration of sevoflurane delivery to a target BIS of 35 +/- 5 led to almost equal end-tidal sevoflurane concentrations in either group and remifentanil did not affect the BIS. There were no side-effects in either group that required intervention. Intubating conditions during sevoflurane anaesthesia in children were found to be improved by a single bolus dose of remifentanil 1 microg.kg-1.

Analgesics, Opioid↗

A follow-up study on occupational exposure to inhaled anaesthetics in Eastern European surgeons and circulating nurses.

OBJECTIVE: Although no dose-response relationship exists for the health risks associated with the occupational exposure to inhaled anaesthetics, public health authorities recommend threshold values. The aim of the present study was to assess whether and to what extent these threshold values are exceeded in surgeons and circulating nurses of an Eastern European university hospital, before and after measures had been taken to reduce occupational exposure. METHODS: At nine workplaces, occupational exposure to nitrous oxide and the volatile anaesthetic used (halothane or isoflurane) was measured within the breathing zones of surgeons and circulating nurses by means of photoacoustic infrared spectrometry. The measurements were carried out in 1996 and were repeated in 1997 after the installation of active scavenging devices at five workplaces, and an air-conditioning system at one workplace. RESULTS: Occupational exposure to nitrous oxide and halothane or isoflurane was lower in 1997 compared with that of 1996. In 1996, 89% of the nitrous oxide values were above the European threshold value of 100 ppm, whereas in 1997 approximately 50% were above this limit. In 1996 the majority of the measurements for the volatile anaesthetics were already below 5 ppm halothane and 10 ppm isoflurane and the number of measurements exceeding these limits was further reduced in 1997. CONCLUSION: The measures taken were effective in reducing waste gas exposure. Nevertheless, further efforts are necessary, especially for nitrous oxide, to reach Western European standards and to minimise possible health risks. These efforts comprise the installation of (active) scavenging devices, air-conditioning systems and new anaesthesia machines at all workplaces, the use of low-flow anaesthesia, the replacement of inhaled anaesthetics by intravenous anaesthetics and an appropriate working technique.

Anesthetics, Inhalation↗

Nitric oxide-dependent down-regulation of angiotensin II type 2 receptors during experimental sepsis.

OBJECTIVE: The systemic renin-angiotensin system is highly activated during septic shock. This has focused interest in regulation of the adrenal angiotensin II type 2 receptor (AT2) as the target thought to mediate angiotensin II-induced adrenal catecholamine release during experimental sepsis in vivo. In addition, the influence of typical endogenous mediators of sepsis, such as proinflammatory cytokines and nitric oxide, on AT2 receptor expression should be investigated in vitro. DESIGN: Prospective animal trial followed by a controlled cell culture study. SETTING: Laboratory of the Department of Anesthesiology. SUBJECTS: Male Sprague-Dawley rats weighing 200-250 g, PC12 cell line. INTERVENTIONS: Rats were injected with lipopolysaccharide to stimulate Gram-negative sepsis or lipoteichoic acid to stimulate Gram-positive sepsis. AT2 receptor expression, abundance of the proinflammatory cytokines (interleukin-1beta, tumor necrosis factor-alpha, and interferon-gamma), and nitric oxide synthase II expression have been determined in the adrenal gland. Rat adrenal pheochromocytoma cells were incubated with these cytokines or with the nitric oxide donors sodium nitroprusside or S-nitroso-N-acetylpenicillamine to investigate the regulation of AT2 receptors during severe inflammation on a cellular level. MEASUREMENTS AND MAIN RESULTS: In the adrenal gland, AT2 receptor expression was down-regulated in both models of sepsis, whereas tissue cytokine concentrations were elevated and nitric oxide synthase II expression was induced. Incubation of PC12 cells with proinflammatory cytokines resulted in a dose-dependent diminished expression of AT2 receptors, which was mimicked by incubation with nitric oxide donors. Blocking of cytokine-induced nitric oxide synthesis by co-incubation of PC12 cells with NG-nitro-l-arginine methyl ester prevented down-regulation of AT2 receptors. CONCLUSIONS: These findings show that in our model of sepsis, the expression of AT2 receptors in the adrenal gland is down-regulated in a nitric oxide-dependent manner. Because AT2 receptors are thought to be involved in adrenal catecholamine secretion in a stimulatory fashion, the diminished expression of AT2 receptors could play an important role in the pathogenesis of septic shock via impaired angiotensin II-induced adrenal catecholamine release, despite a strong activation of the systemic renin-angiotensin system.

Adrenal Glands↗

Downregulation of angiotensin II type 1 receptors during sepsis.

Our study aimed to characterize the mechanisms underlying the attenuated cardiovascular responsiveness toward the renin-angiotensin system during sepsis. For this purpose, we determined the effects of experimental Gram-negative and Gram-positive sepsis in rats. We found that sepsis led to a ubiquitous upregulation of NO synthase isoform II expression and to pronounced hypotension. Despite increased plasma renin activity and plasma angiotensin (Ang) II levels, plasma aldosterone concentrations were normal, and the blood pressure response to exogenous Ang II was markedly diminished in septic rats. Mimicking the fall of blood pressure during sepsis by short-term infusion of the NO donor sodium nitroprusside in normal rats did not alter their blood pressure response to exogenous Ang II. Therefore, we considered the possibility of an altered expression of Ang II receptors during sepsis. It turned out that Ang II type 1 receptor expression was markedly downregulated in all organs of septic rats. Further in vitro studies with rat renal mesangial cells showed that NO and a combination of proinflammatory cytokines (interleukin-1beta, tumor necrosis factor-alpha, and interferon-gamma) downregulated Ang II type 1 receptor expression in a synergistic fashion. In summary, our data suggest that sepsis causes a systemic downregulation of Ang II type 1 receptors that is likely mediated by proinflammatory cytokines and NO. We suggest that this downregulation of Ang II type 1 receptors is the main reason for the attenuated responsiveness of blood pressure and of aldosterone formation to Ang II and, therefore, contributes to the characteristic septic shock.

Adrenal Glands↗

Occupational exposure to inhaled anaesthetics: a follow-up study on anaesthetists of an eastern European university hospital.

BACKGROUND: Although no dose-response relationship for the health risks associated with the occupational exposure to inhaled anaesthetics exists, public health authorities recommend threshold values. The aim of the present study was to assess if and to what extent these threshold values are exceeded in an eastern European university hospital before and after measures had been taken to reduce occupational exposure. METHODS: At nine workplaces occupational exposure of anaesthetists to nitrous oxide and halothane or isoflurane was measured by means of photoacoustic infrared spectrometry. The measurements were carried out in 1996 and were repeated in 1997 after the installation of active scavenging devices at five workplaces and an air-conditioning system at one workplace. RESULTS: Occupational exposure to nitrous oxide and halothane or isoflurane was lower in 1997 compared to 1996. In 1997 most of the nitrous oxide values still exceeded the threshold value of 100 ppm, whereas most of the halothane and isoflurane values were already below the threshold values of 5 ppm and 10 ppm in 1996. CONCLUSION: The measures taken were effective in reducing waste gas exposure. Nevertheless, further efforts are necessary, especially for nitrous oxide, to reach western European standards. These efforts comprise structural measures such as active scavenging devices and air-conditioning systems at all workplaces, the use of total intravenous anaesthesia, low-flow anaesthesia and an appropriate working technique.

Anesthesiology↗

Evaluation of self-reported failures in cognitive function after cardiac and noncardiac surgery.

Long-term cognitive deficits after cardiac surgical procedures involving cardiopulmonary bypass have been well documented. The occurrence of prolonged cognitive changes after noncardiac surgery has not, however, been clearly established. Using the Cognitive Failures Questionnaire, which permits self-assessment of cognitive impairment, we studied 50 patients before and 2 months after coronary bypass surgery and major vascular surgical procedures. Pre-operative test scores did not differ between groups. Postoperatively, 24 cardiac surgical patients and 22 vascular surgical patients completed the questionnaire. Both groups reported significantly more cognitive failures occurring after surgery than in the pre-operative period. This suggests that there are factors other than the exposure to cardiopulmonary bypass during cardiac surgery that affect self-assessed, long-term postoperative cognitive sequelae.

Aged↗

Dry soda lime markedly degrades sevoflurane during simulated inhalation induction.

We have investigated gas composition during simulated inhalation induction with sevoflurane to elucidate possible mechanisms of incidental prolonged induction times and airway irritation. Using a circle system, 8% sevoflurane in oxygen 6 litre min-1 was washed into an absorbing canister filled with fresh soda lime containing 2.9% KOH (Draegersorb, 'D') or no KOH (< 0.01%, Sofnolime, 'S'). The absorbent was dried by oxygen 20,000 litre before every second experiment. Maximum soda lime temperatures attained after 4-6 min were 107 degrees C using dry D and 62 degrees C (61 degrees C) with dry S. Temperature did not increase with fresh soda lime. With dry soda lime, sevoflurane was not detected at the T-piece for 3 min and reached 6-7% within 6-10 min. After 1 min, we detected methanol and compound A (CH2F-O-C(= CF2) (CF3)). Total amounts over 20 min were: methanol 1125 mg (D dry), 334 mg (S dry) and < 5 mg (fresh soda lime); compound A 148 mg (D dry), 13 mg (S dry) and 3-8 mg (fresh); and fluoride 8.5 mg (D dry), 3.3 mg (S dry) and 1 mg (fresh). Formaldehyde was detected only with dry lime (D > 2.5 mg, S > 0.6 mg). In summary, the use of moist soda lime is of crucial importance during inhalation induction. With dry soda lime, the patient may inhale potentially toxic degradation products in significant amounts. Sevoflurane degradation is aggravated by a high KOH content of the lime. The observed airway irritation may be caused by formic acid, which is generated in isomolar concentrations with methanol (Cannizzaro reaction). The amount of compound A found with dry KOH-containing lime is unlikely to be noxious.

Anesthesia, Closed-Circuit↗

Continuous cardiac output measurement: pulse contour analysis vs thermodilution technique in cardiac surgical patients.

We have analysed the clinical agreement between two methods of continuous cardiac output measurement pulse contour analysis (PCCO) and a continuous thermodilution technique (CCO), were both compared with the intermittent bolus thermodilution technique (BCO). Measurements were performed in 26 cardiac surgical patients (groups 1 and 2, 13 patients each, with an ejection fraction > 45% and < 45%, respectively) at 12 selected times. During operation, mean differences (bias) between PCCO-BCO and CCO-BCO did not differ in either group. However, phenylephrine-induced increases in systemic vascular resistance (SVR) by approximately 60% resulted in significant differences. Significantly higher absolute bias values of PCCO-BCO compared with CCO-BCO were also found early after operation in the ICU. Thus PCCO and CCO provided comparable measurements during coronary bypass surgery. After marked changes in SVR, further calibration of the PCCO device is necessary.

Adult↗

Compound A does not accumulate during closed circuit sevoflurane anaesthesia with the Physioflex.

We have investigated inspiratory and end-tidal gas composition during sevoflurane anaesthesia in a closed circle system with continuous gas flow (70 litre min-1, Physioflex) to determine possible accumulation of sevoflurane degradation products. During five abdominal operations in adults lasting more than 2 h, anaesthesia was maintained with an end-tidal concentration of 2% sevoflurane in 40% oxygen-air. The circle included an absorbing canister filled with 1 litre of fresh soda lime. Samples were obtained at the end of an expiration from the tracheal tube and from the inspiratory limb before, and at selected times after, addition of sevoflurane. The temperature of soda lime was 24.7 +/- 0.7 degrees C at the beginning and reached a maximum of 31.2 +/- 1.0 degrees C after 20-30 min, followed by a plateau. Inspiratory compound A (CH2F-O-C(= CF2)(CF3)) 3-8 ppm was detected after 10 min, but did not accumulate in the circle over 2 h without flushing. Expired concentrations were consistently lower with 1.5-3 ppm signalling absorption by patients. Calculated total amounts absorbed over 2 h varied between 2.0 and 7.2 ppm h. Other degradation products such as compound B or methanol were not detected. In summary, we did not detect sevoflurane metabolites with soda lime in significant amounts during closed circle anaesthesia with the Physioflex. The observed concentrations of compound A were below the threshold of nephrotoxicity in rats by a factor of more than 20.

Aged↗

Cardiovascular autonomic dysfunction and hemodynamic response to anesthetic induction in patients with coronary artery disease and diabetes mellitus.

UNLABELLED: Autonomic neuropathy is a major complication of diabetes mellitus and is reported to be associated with increased perioperative hemodynamic instability. We investigated the relationship between autonomic dysfunction and hemodynamic response to anesthetic induction in diabetic and nondiabetic patients with coronary artery disease. We studied 60 patients scheduled for coronary artery surgery, 30 suffering from diabetes mellitus. Preoperative evaluation included traditional cardiovascular autonomic function tests (coefficient of variation of 150 beat-to-beat intervals in heart rate at rest, heart rate response to deep breathing, and heart rate and arterial blood pressure response to standing), spectral analysis of blood pressure and heart rate variability (HRV), and the computation of spontaneous baroreflex sensitivity. After premedication with clorazepate, anesthesia was induced with sufentanil (0.5 microg/kg), etomidate (0.1-0.2 mg/kg), and vecuronium (0.1 mg/kg). Heart rate and blood pressure before anesthetic induction and before and after tracheal intubation were compared between groups. Autonomic function tests, spectral analysis of HRV, and spontaneous baroreflex sensitivity revealed significant differences between patient groups. Most diabetic patients (n = 23) had one or more abnormal test results, in contrast to most nondiabetic patients, who did not show signs of autonomic neuropathy (n = 23). There was no relationship between cardiovascular autonomic function and hemodynamic behavior during anesthetic induction. The blood pressure response to anesthetic induction was not different between patient groups, even when comparing the subgroups with and without abnormal autonomic function tests. These findings indicate that increased hemodynamic instability during anesthetic induction is not obligatory in patients with diabetes mellitus and autonomic dysfunction. IMPLICATIONS: This study indicates that increased hemodynamic instability during anesthetic induction is not obligatory in patients with coronary artery disease and autonomic dysfunction.

Adult↗

[Occupational exposure and environmental pollution: the role of inhalation anesthetics with special consideration of sevoflurane].

There are a number of assays available to study genetic toxicity of inhalation anaesthetics. Those discussed in this review are the Ames Salmonella mutagenesis test and assays for structural chromosome aberrations, micronuclei (MN) and sister chromatid exchanges (SCEs). None of these assays showed abnormalities induced by volatile inhalation anaesthetics. Only Compound A induced a slight increase in the number of SCEs. However, the implications of this in vitro study are unclear. Results of studies focussing on the effects of long-term occupational exposure to inhalation anaesthetics are controversial. Neither harmfulness nor safety of chronic exposure to low concentrations of inhalation anaesthetics have been proven. Although there is no clear evidence of harmfulness, there is general agreement that occupational exposure should be minimized for precautionary reasons. This particularly applies to N2O. Therefore, occupational exposure standards have been established in many countries, though not yet for sevoflurane and desflurane. In Germany, occupational exposure can be kept below the threshold values, when working in operation theatres with a standard air conditioning system, a high-flow scavenging system, low leakage anaesthesia machines and preventative maintenance of equipment. Under these conditions occupational exposure is low even when using laryngeal mask airways and uncuffed tracheal tubes. Sevoflurane is a halocarbon, but is only partially halogenated and the only halogen it contains is fluorine. Sevoflurane, therefore, appears to have an insignificant effect on ozone depletion and its contribution to the greenhouse effect is negligible.

Anesthesiology↗

Nitrous oxide impairs the neutrophil oxidative response.

BACKGROUND: Nitrous oxide has been shown inconsistently to impair the oxidative function of neutrophils. The choice of the stimulus, receptor agonists, or stimuli acting independent of receptors seems to determine whether nitrous oxide impairs the oxidative functions, suggesting an interference with the cytosolic signaling of neutrophils. METHODS: Production of hydrogen peroxide by neutrophils was assessed using flow cytometric analysis. N-formyl-methionyl-leucyl-phenylalanine (FMLP), C5a, dioctanylglycerol, and phorbol-12-myristate-13-acetate were used as stimuli. In addition, the expression of receptors for FMLP and the cytosolic-free calcium response of cells were measured. RESULTS: Nitrous oxide depresses C5a- or FMLP-induced generation of reactive oxygen derivatives in a concentration-dependent manner. However, the response with direct activation of protein kinase C was unaffected. Further, the number of FMLP receptors and the cytosolic calcium response were unaffected. Inhibition of the oxidative response was not reversible within the observation period of 4 h. CONCLUSIONS: Nitrous oxide inhibited the intracellular signaling of the investigated G-protein-coupled receptors for chemotactic peptides. No interference of nitrous oxide with reduced nicotinamide adenine dinucleotide phosphate oxidase, the oxidative enzyme system of neutrophils, nor with its activation through protein kinase C was detected.

Adult↗

Waste gas exposure during desflurane and isoflurane anaesthesia.

BACKGROUND: Currently, there are no data available concerning the occupational exposure to desflurane during general anaesthesia. This prospective, randomized study reports on occupational exposure to desflurane, compared to isoflurane, in a modern operation theatre (OT). METHODS: The study was performed in an OT equipped with a modern air-conditioning system and with a low-leakage anaesthesia machine connected to a central scavenging system. Trace concentrations of the anaesthetics were measured continuously by means of a photoacoustic infrared spectrometer during general anaesthesia in 30 patients undergoing eye surgery. Values were obtained within the breathing zone of the anaesthetist, the surgeon, the auxiliary nurse and at the mouth of the patient. RESULTS: Desflurane and isoflurane were administered with median (range) endtidal concentrations of 4.7 (3.8-10.3) vol% and 0.9 (0.6-1.4) vol%, respectively. The personnel-related median values of the average trace concentrations of desflurane and isoflurane were 0.5 (0.01-7.5) ppm and 0.2 (0.01-1.6) ppm, respectively. CONCLUSIONS: Occupational exposure to desflurane is low in the environment of a modern OT, even though it has to be administered in approximately 5-fold higher concentrations compared to isoflurane.

Air Conditioning↗

[Biological monitoring during exposure to the anesthetics isoflurane and sevoflurane].

Exposure to traces of inhaled anaesthetic agents may impair the health of the operating theatre personnel. Although no cause-effect relationship has been found, most public health authorities recommend various occupational exposure standards to minimize possible health risks. If metabolites of the substances are known, biological monitoring is an alternative to the monitoring of the operating theatre's air. The new anaesthetic agent Sevoflurane is considerably more transformed to fluoride than Isoflurane. Concerning fluoride there exist Biological Tolerance Values of 4.0-7.0 mg fluoride (F-) per gram creatinine (Crea). The aim of our study was to compare the fluoride excretion under the occupational exposure to sevoflurane and isoflurane. By the means of a direct-reading instrument trace concentrations of sevoflurane, isoflurane, and nitrous oxide were measured during 40 anaesthetic procedures. Urine samples were collected before (Z1) and after the workshift (Z2), and in the morning of the next day (Z3). The analysis was done by the means of an ionselective electrode. The personnel-related concentrations (median, range) were 0.50 (0.16-7.04) ppm isoflurance and 27.36 (5.87-467.10) ppm nitrous oxide, and 0.79 (0.15-1.95) ppm sevoflurane and 17.74 (2.45-84.20) ppm nitrous oxide. The resulting fluoride values presented at Z1, Z2, and Z3 as median (range) during exposure to isoflurane were 0.15 (0.11-0.53), 0.19 (0.11-0.53), 0.20 (0.11-0.31) mg F-/g Crea, and 0.15 (0.10-0.46), 0.22 (0.13-0.44), 0.23 (0.15-0.69) mg F-/g Crea during exposure to sevoflurance, respectively. The trace concentrations were clearly under 10 ppm for the volatile substances and 100 ppm for nitrous oxide. The values are comparable to data recorded under similar working conditions. The measured fluoride values were low and remained under the legal tolerance values. Under the described conditions potential health risks were low.

Air Pollution, Indoor↗