PubMed Health⌕ Search

Biomedical subjects

J Hochberger

Publications and source records attributed to J Hochberger.

At least 19 recordsLinked to original sources

The compactEASIE is a feasible training model for endoscopic novices: a prospective randomised trial.

BACKGROUND: The objective benefit of a training using the compact Erlangen Active Simulator for Interventional Endoscopy-simulator was demonstrated in two prospective educational trials (New York, France). The present study analysed whether endoscopic novices are able to reach a comparable level of endoscopic skills as in the above-described projects. METHODS: Twenty-seven endoscopic novices (medical students, first year residents) were enrolled in this prospective, randomised trial. The compact Erlangen Active Simulator for Interventional Endoscopy-simulator with an upper GI-organ package and blood perfusion system was used as a training tool. Basic evaluation of endoscopic skills was performed after a practical and theoretical course in diagnostic upper GI endoscopy followed by a stratified randomisation according to the rating in endoscopic skills into intensive (n=14) and control group (n=13). The intensive group was trained 12 times every second week over 7 months in 4 endoscopic disciplines (manual skills, injection therapy, haemoclip, band ligation) by skilled endoscopist (three trainees/simulator). Assessment was performed (single steps/overall) using an analogue scale from 1 to 10 (1=worst, 10=optimal performance) by expert tutors. The control group was not trained. Blinded final evaluation of all participants was performed in January 2003. RESULTS: We observed in all techniques applied a significant improvement of endoscopic skills and of the performance time in the intensive group compared to the control group (p<0.001). The comparison with the previous projects showed that the intensively trained novices achieved comparable levels of performance to the GI fellows in the New York and France Project (at least 80% of the median score in three out of four techniques). CONCLUSION: Endoscopic novices acquired notable skills in interventional endoscopy in the simulator by an intensive, periodical training using the compactEASIE.

Clinical Competence↗

"Hemodynamic efficacy" of two endoscopic clip devices used in the treatment of bleeding vessels, tested in an experimental setting using the compact Erlangen Active Simulator for Interventional Endoscopy (compactEASIE) training model.

BACKGROUND AND STUDY AIMS: Hemoclip therapy is a well-established procedure in the treatment of gastrointestinal bleeding. Although new products are provided periodically by the industry, comparative investigations are lacking. We compared two different hemoclip devices in an experimental setting, assessing them using objective hemostatic parameters. MATERIALS AND METHODS: We compared two disposable clip devices (Olympus HX-200L-135 (n = 40) vs. Wilson-Cook Tri-Clip (n = 40)) in an experimental setting using the compact Erlangen Active Simulator for Interventional Endoscopy (compactEASIE) training model equipped with an upper gastrointestinal-organ package for bleeding simulation. This was a randomized, prospective, controlled trial. Four investigators with different levels of endoscopic experience applied ten hemoclip devices of each type to the spurting vessels, the clips allocated using a randomized list for each investigator. The efficacy of hemostasis was determined by continuous measurement of the pressure within the afferent vessel before and after clip application and calculation of the relative reduction of vessel diameter by the clip device. The system pressure was recorded over the period from 1 minute before to 1 minute after clip application. A secondary end point was a subjective assessment of the whole clip application procedure by the endoscopist and the assisting nurse, using a visual analog scale (0 - 100, with 100 representing the best experience). RESULTS: A total of 39/40 clips of each type were applied successfully. Both clip devices led to a significant increase in system pressure, representing significant relative reduction of vessel diameter (Olympus 5.4 +/- 7.5 %, p < 0.001; Cook 4.9 +/- 8.0 %, p < 0.001). Overall, there was no significant difference between the two devices ( P = 0.756). However, the investigator with the least experience in endoscopy (< 100 procedures) produced significantly inferior results compared with the other three investigators, who had performed between 2000 and 6000 procedures each ( P < 0.05). We found no evidence of a learning curve from the intra-observer results. The devices received good, but not significantly different, overall ratings by the endoscopists (Olympus 69 +/- 24 vs. Wilson-Cook 65 +/- 16) and by the assisting nurses (Olympus 77 +/- 9 vs. Wilson-Cook 70 +/- 22). CONCLUSIONS: Using an established cadaveric training model, no significant difference was found between the two types of hemoclip devices with respect to their "hemostatic efficacy". However, the experience of the endoscopist appears to play a major role in successful clip application. The use of a feedback mechanism in emergency endoscopy training, using continuous intravessel pressure monitoring, may substantially enhance the efficacy of training, resulting in a similar improvement in clinical results.

Cadaver↗

Objective benefit of a 1-day training course in endoscopic hemostasis using the "compactEASIE" endoscopy simulator.

BACKGROUND AND STUDY AIMS: The Erlangen Active Simulator for Interventional Endoscopy (EASIE) was introduced in 1997 as a training model for interventional endoscopy. Objective evidence of the benefits of training with this model has not previously been published. As part of two long-term projects, the benefits of a 1-day training course with the "compactEASIE" simulator were evaluated. MATERIALS AND METHODS: Fourteen American and 18 French gastroenterology fellows were enrolled. These fellows were participants in the intensive groups performing training in endoscopic hemostasis, with a total number of 28 fellows in New York and 36 in France. Gastrointestinal endoscopy faculty members in New York and France evaluated and timed the fellows in four disciplines to establish baseline skills (manual skills; injection and coagulation; Hemoclip application; and variceal ligation) with the compactEASIE simulator. The trainees were reevaluated after an intensive 1-day course (with two or three fellows and one instructor per station), also including preparation and assistance for each procedure. The assessment (overall and parts) was done by expert tutors using an ordinal scale ranging from 1 to 10 (1 = poorest, 10 = best), recording also mistakes and performance time. The compactEASIE simulator, equipped with an upper gastrointestinal organ package and an artificial blood perfusion system, was used as the training tool. RESULTS: A highly significant improvement ( P < or = 0.001) was observed in the performance of all endoscopic techniques. A significant reduction in performance time was also observed with three of the four endoscopic techniques. Successful hemostasis was significantly improved in two out of three techniques. CONCLUSIONS: A 1-day training course on endoscopic hemostasis using the compactEASIE simulator is capable of improving the performance of hemostasis procedures. Long-term effects of repeated training sessions are currently subject of collaborative studies in New York and France.

Clinical Competence↗

Successful laserlithotripsy in Bouveret's syndrome using a new frequency doubled doublepulse Nd:YAG laser (FREDDY).

Gastric outlet obstruction as a result of gallstone (Bouveret syndrome) is a rare but serious complication of cholelithiasis. In many cases, surgery has been conducted for treatment. In recent years, minimal invasive treatment modalities (e.g. shockwave lithotripsy) have been shown to be effective in some of those patients. Laserlithotripsy has so far been described in two cases with a Rhodamine-6G dye laser. We present the case of a 90-year-old woman with duodenal obstruction due to a huge gallstone. The patient was referred to our hospital because attempts at endoscopic extraction and extracorporeal shockwave lithotripsy had failed. The man was treated successfully in just one session with a new cost-efficient frequency doubled doublepulse Nd:YAG laser (FREDDY) using a total of 5726 laser pulses (120 mJ pulse energy, 10 Hz pulse repetition rate) and recovered rapidly. Laserlithotripsy can be considered an effective non-invasive therapeutic alternative to surgical treatment in Bouveret's syndrome, especially in old or high-risk patients.

Aged↗

The compact Erlangen Active Simulator for Interventional Endoscopy: a prospective comparison in structured team-training courses on "endoscopic hemostasis" for doctors and nurses to the "Endo-Trainer" model.

BACKGROUND: In 1997 Hochberger and Neumann presented the "Erlangen Biosimulation Model" (commercialized as the "Erlangen Endo-Trainer") at various national and international meetings. The new compactEASIE is a simplified version of the original "Biosimulation Model" (Endo-Trainer) and is specially designed for easy handling. CompactEASIE is reduced in its features, focusing exclusively on flexible endoscopy training. The acceptance of training in endoscopic hemostasis is accepted by workshop participants, as evaluated by a questionnaire on both models. METHODS: Eleven structured courses on endoscopic hemostasis for doctors and nurses organized by the same endoscopists from 3/1998 to 5/1999 were evaluated using one of both models. The questionnaires were filled in by 207/291 trainees (71%). The Endo-Trainer was used in 4 (n = 103) and the compactEASIE in 7 courses (n = 104). Both simulators were equipped with identical types of specially prepared pig-organ packages consisting of esophagus, stomach and duodenum, including artificial sewn-in vessels, polyps and varices. Blood perfusion was done with a roller pump connected to the sewn-in vessels and blood surrogate. All workshops were identical concerning the course structure: a 30-min theoretical introduction on ulcer bleeding was followed by 2 h of practical training in injection techniques and hemoclip application. The second part of variceal therapy consisted of a 30-min theoretical introduction prior to 2 h of practical training on sclerotherapy, band ligation and cyanoacrylate application. Finally, a questionnaire on the trainees' pre-experience and their rating of the different workshop sections was handed out to each participant. RESULTS: Previous endoscopic experience was comparable in both groups. The training in both simulators was highly accepted by the trainees (compactEASIE 95% excellent and good versus EASIE (Endo-Trainer) 97%) and did not show any significant difference (P = 0.493). Even in the assessment of the single techniques, no statistical difference was observed. Furthermore, the assessments of the closeness to reality and the endoscopic environment in both simulators were identical. CONCLUSIONS: Both simulators (Endo-Trainer, compactEASIE) are excellent educational tools for interventional endoscopy with a high level of acceptance. The easy-to-handle, "lightweight" compactEASIE is a significant, progress tool for the future.

Clinical Competence↗

Management of difficult common bile duct stones.

More than 80% of all CBD stones can be effectively treated by endoscopic sphincterotomy and stone extraction using baskets or balloon catheters. For stones up to 2.5 cm in diameter, mechanical lithotripsy is the method of choice as a next step. Very large, impacted, or very hard concretions, however, often make mechanical lithotripsy cumbersome or even impossible. For these stones laser lithotripsy, EHL, and ESWL are nonoperative options, especially for elderly patients and patients with an elevated surgical risk. Because these methods are often only available at endoscopic centers, stenting is a treatment modality for immediate stone therapy, but as a definitive treatment it should be restricted to selected cases. ESWL, EHL, and laser lithotripsy yield similar success rates of 80% to 95% and may be used complementarily in endoscopic centers. ESWL is the preferred therapy in intrahepatic lithiasis. Laser lithotripsy shows the best results in CBD stones. Electrohydraulic lithotripsy is rarely used because of its high potential for tissue damage and bleeding. Laser lithotripsy using smart laser systems such as the rhodamine 6G dye laser and the FREDDY laser system can simplify the treatment of these difficult bile duct stones. The rhodamine 6G-dye laser allows blind fragmentation of these stones by exclusive insertion of a 7-F metal marked standard catheter into the bile duct by standard duodenoscopes using intermittent fluoroscopy. An oSTDS safely cuts off the laser pulse if contact with the stone is lost, thus preserving the bile duct from potential damage. Unfortunately the system is no longer produced. The new FREDDY laser lithotriptor with a piezoacoustic stone/tissue discrimination system offers an alternative to the rhodamine 6G dye laser system at less than half the financial investment. Effective stone fragmentation is accompanied by only low tissue alteration. The holmium:YAG laser is an effective multidisciplinary lithotriptor, but it can be used only under cholangioscopic control, limiting its use to gastroenterologic centers.

Choledocholithiasis↗

Endoscopic antireflux treatment: fact, fiction or future?

Medical therapy with proton pump inhibitors (PPIs), aside from surgery, is the established and most effective treatment approach for chronic gastroesophageal reflux disease (GERD). Recently developed endoscopic antireflux procedures may be an alternative for a subset of patients with uncomplicated, mild GERD. Given the perioperative morbidity and mortality risk of laparoscopic fundoplication, less invasive semi-surgical and flexible endoscopic techniques may be an option for patients who cannot or wish not to take long-term medication. These clinical procedures include endoscopic suturing devices, focal radiofrequency coagulation in the cardia and bioimplants. While many of these techniques have shown good results in preliminary studies, long-term results are not yet available and therefore all such procedures have to be considered experimental. Their effectiveness will need to be compared with that of established treatment forms.

Electrocoagulation↗

A score card for upper GI endoscopy: Evaluation of interobserver variability in examiners with various levels of experience.

BACKGROUND: In most European countries, training in GI endoscopy has largely been based on hands-on acquisition of experience in patients rather than on a structured training programme. With the development of training models systematic hands-on training in a variety of diagnostic and therapeutic endoscopy techniques was achieved. Little, however, is known about methods of objectively assessing trainees' performance. We therefore developed an assessment 'score card' for upper GI endoscopy and tested it in endoscopists with various levels of experience. The aim of the study was therefore to assess interobserver variations in the evaluation of trainees. METHODS: On the basis of textbook and expert opinions a consensus group of eight experienced endoscopists developed a score card for diagnostic upper GI endoscopy with biopsy. The score card includes an assessment of the single steps of the procedure as well as of the times needed to complete each step. This score card was then evaluated in a further conference including ten experts who blindly assessed videotapes of 15 endoscopists performing upper GI endoscopy in a training bio-simulation model (the 'Erlangen Endo-Trainer'). On the basis of their previous experience (i. e. the number of endoscopies performed) these 15 endoscopists were classified into four groups: very experienced, experienced, having some experience and inexperienced. Interobserver variability (IOV) was tested for the various score card parameters (Kendall's rank-correlation coefficient 0.0-0.5 poor, 0.5-1.0 good agreement). In addition, the correlation between the score card assessment and the examiners' experience levels was analysed. RESULTS: Despite poor IOV results for all the parameters tested (Kendall coefficient < 0.3), the assessment parameters correlated well when the examiners' different experience levels were taken into account (correlation coefficient 0.59-0.89, p < 0.05). The score card parameters were suitable for differentiating between the four groups of examiners with different levels of endoscopic experience. CONCLUSIONS: As expected with scores involving subjective assessment of performance, the variability between reviewers was substantial. Nevertheless, the assessment score was capable of distinguishing reliably between different experience levels in terms of a good individual observer consistency. The score card can therefore be used to document both training status and progress during endoscopy training courses using bio-simulation models, and this might be able to provide improved quality assurance in GI endoscopy training.

Animals↗

Release of mast cell tryptase from human colorectal mucosa in inflammatory bowel disease.

BACKGROUND: Histologic detection of mast cells cannot adequately reflect their function and state of activation, since degranulated mast cells may escape from histologic assessment. To better define the role of mast cells in inflammatory bowel disease, the spontaneous secretion of mast cell tryptase, a highly mast cell specific protease, was measured from colorectal samples. METHODS: After detection of the initial basal tryptase release, gut mucosal samples were incubated in a modified Hanks/RPM1 medium using a mucosa oxygenation system. Spontaneous tryptase secretion from 153 viable samples of 22 controls, 30 patients with Crohn disease (CD) and 19 with ulcerative colitis (UC) was followed over 4 h. Tryptase was measured by radioimmunoassay. RESULTS: The rates of the initial basal tryptase release revealed that mast cell activation occurs during active inflammation in CD and UC. While the time course of tryptase release was similar in all three groups, spontaneous tryptase secretion (over 4 h) was found to be significantly enhanced and prolonged only in UC (P < 0.01 compared to controls), but not in CD. CONCLUSIONS: This study provides clear evidence from viable endoscopic colorectal samples that mast cell mediators were secreted during active inflammation in CD and UC. However, the extent of mast cell involvement and activation differs considerably between CD and UC. Significantly increased rates of tryptase secretion were found both in non-inflamed and inflamed tissue of UC, indicating that mast cell involvement is a typical feature of UC.

Adult↗

Immunoglobulin E and eosinophilic cationic protein in segmental lavage fluid of the small and large bowel identify patients with food allergy.

OBJECTIVE: Members of the general population often assume that they suffer from food allergy, but the true prevalence is low. Testing for the diagnosis of food-related hypersensitivity entails laborious procedures, including GI endoscopy. Our objective was to develop an endoscopic screening approach for food allergy. METHODS: Endoscopically guided segmental lavage was performed in 11 patients with GI allergy and in 20 controls during lower GI endoscopy of the terminal ileum, the coecum, and the rectosigmoid. Eosinophilic cationic protein (ECP) and protein were measured in native lavage fluid, and immunoglobulin E (IgE) was also measured after a 10-fold lavage concentration. RESULTS: IgE/protein in lavage fluid from the coecum (0.055 +/- 0.068 U/mg vs 0.003 +/- 0.012 U/mg; p = 0.001) and the rectosigmoid (0.134 +/- 0.170 U/mg vs 0.019 +/- 0.042 U/mg; p < 0.05) was significantly elevated in patients with GI allergy. ECP/protein was significantly elevated at the terminal ileum (22.95 +/- 37.67 microg/mg vs 7.09 +/- 7.68 microg/mg; p < 0.05) and the rectosigmoid (23.66 +/- 19.43 microg/mg vs 11.97 +/- 16.39 microg/mg; p < 0.05). The combined use of GI lavage IgE and ECP as a diagnostic test for food allergy resulted in a sensitivity of 91% and a specificity of 80%. CONCLUSIONS: In endoscopically guided segmental lavage fluid, IgE and ECP/protein are increased in patients with food allergy. These measurements seem to offer an attractive diagnostic tool and may serve as a screening method.

Adult↗

Mucosal production of antigastric autoantibodies in Helicobacter pylori gastritis.

BACKGROUND: Apart form bacterial virulence factors of Helicobacter pylori, certain host factors influence the pathogenesis of H. pylori gastritis. In particular, antigastric autoantibodies that are detectable in the sera of a substantial proportion of H. pylori were shown to correlate with the development of gastric atrophy. The aim of this study was to analyze the possible antigastric autoimmune response in H. pylori gastritis at the site where the action is, i.e. , in the gastric mucosa. MATERIAL AND METHODS: Gastric biopsy specimens from antrum and corpus mucosa of 24 H. pylori-infected and of 33 noninfected patients were cultured for 3 days, and tissue culture supernatants were analyzed for the amount of locally produced IgA and IgG. Antigastric autoantibodies were screened in the sera and in the supernatants by means of immunohistochemistry. RESULTS: The infected patients had significantly higher concentrations of locally produced IgA, whereas the IgG concentrations were virtually the same in infected and noninfected patients. IgG or IgA antigastric autoantibodies, or both, were detectable only in the sera (38%) and supernatants (17%) of infected patients. Interestingly, the patient with the strongest local autoimmune response showed body-predominant H. pylori gastritis, with destruction of gastric glands and atrophy of the body mucosa. CONCLUSIONS: These results demonstrate that antigastric autoimmune reactions are detectable at the site of the disease and might be relevant for the pathogenesis of gastric mucosa atrophy in H. pylori gastritis.

Adult↗

In vitro study concerning the efficiency of the frequency-doubled double-pulse Neodymium:YAG laser (FREDDY) for lithotripsy of calculi in the urinary tract.

BACKGROUND AND OBJECTIVES: In a preclinical study we have tested both in vitro and in vivo, a new type of pulsed solid-state laser system that has not been applied in urology so far and has been developed for optimized intracorporal lithotripsy of biliary, salivary, and urinary calculi. STUDY DESIGN/MATERIALS AND METHODS: Sixty one calculi from the human urinary tract were split in vitro into fragments with a remaining particle size of </= 2 mm using the prototype of a short-pulsed passively Q-switched and frequency-doubled double-pulse Neodymium:YAG laser. In a supplementary animal test, the bladder mucosa of five rabbits was directly exposed to a highly rated laser beam to be able to assess the tissue lesion potential of the system. RESULTS: All the 61 urinary calculi with different composition were successfully split in vitro within a short period of time (2.5 +/- 4.6 minutes). During histopathologic examination of the exposed bladder walls of the rabbits only a small tissue lesion potential with urothelium changes exclusively at the surface was ascertained. CONCLUSION: The high degree of fragmentation efficiency, the purchase and maintenance costs, which due to its design are substantially lower in comparison to other laser lithotriptors, and the high degree of safety during application make this new laser a real alternative not only to the present laser lithotripsy systems but also to common ballistic lithotriptors.

Animals↗

Disposable-sheath, flexible gastroscope system versus standard gastroscopes: a prospective, randomized trial.

BACKGROUND: Endoscopically transmitted infections due to inadequate disinfection are rare but well-recognized complications. A new prototype of a flexible, fiberoptic endoscope has been developed that uses a disposable sheath to cover and protect all working surfaces of the endoscope from contamination. The present study investigated the function, reprocessing, and hygienic status of this endoscope system in comparison with standard systems. METHODS: In a prospective, randomized trial, 100 upper endoscopic procedures (50 standard, 50 sheathed) were performed. Analog rating scales were used to evaluate endoscopic performance and reprocessing. Reprocessing time, procedure duration, insertion depth, total instrument downtime, and problems occurring during the procedure were recorded. Microbiologic swabs were obtained from each endoscope. RESULTS: Mean procedure duration was slightly longer with the sheathed system than with standard endoscope (9.9 vs. 8.4 min). Set up and reprocessing times, however, were significantly shorter with the Endosheath (8.9 vs. 48.4 min with the standard endoscope). The disposable-sheath endoscope system permits the rate of performance of procedures to be increased by a factor of up to 3.0. Both endoscopists and reprocessing personnel preferred the standard endoscope. No post-procedure sheath leakage or rupture was seen. CONCLUSION: Our results suggest that the "disposable endoscope" may have important advantages in terms of decreased instrument turn-around time and potentially improved safety.

Adolescent↗