PubMed Health⌕ Search

Biomedical subjects

J Hoogmartens

Publications and source records attributed to J Hoogmartens.

At least 19 recordsLinked to original sources

Improved reversed-phase liquid chromatographic method combined with pulsed electrochemical detection for the analysis of amikacin.

A two-step gradient liquid chromatographic method combined with pulsed electrochemical detection is described for the determination of amikacin and its impurities. The mobile phase is composed of an aqueous solution containing 1.8 g/l sodium 1-octanesulphonate, 14 ml/l tetrahydrofuran, 50 ml/l of phosphate buffer pH 3.0 and sodium sulphate, which was 20 g/l in mobile phase A and 28 g/l in mobile phase B. 0.5 M sodium hydroxide was added post-column to enhance the detection. An investigation of different reversed-phase columns indicated that the Discovery (C18, 5 microm, 250 mm x 4.6 mm i.d.) column was the most suitable. Compared to previously published investigations, the proposed method showed higher sensitivity and efficiency, allowing the separation of the main component amikacin from 16 impurities, 7 of which were of unknown identity. A central composite experimental design was used to assess the robustness. The method showed good repeatability and linearity in the assay range. The method was further applied to analyze some commercial samples.

Algorithms↗

Characterization of impurities in dirithromycin by liquid chromatography/ion trap mass spectrometry.

With a recently developed liquid chromatographic (LC) method, using a phosphate buffer, several unknown impurities present in dirithromycin samples were separated. In this paper, a reversed-phase liquid chromatography-tandem mass spectrometry method is described for the investigation of dirithromycin and related substances. The method employed uses a Zorbax Extend C18 column (250 mm x 4.6 mm I.D.), 5 microm, and a mobile phase consisting of acetonitrile, 2-propanol, water and ammonium acetate solution pH 8.5. Mass spectral data are acquired on an LCQ ion trap mass spectrometer equipped with an electrospray ion (ESI) source operated in the positive ion mode. The LCQ is ideally suited for the identification of related substances because it provides on-line LC/MS(n) capability, which allows efficient identification without time-consuming isolation and purification procedures. Using this method, the fragmentation behavior of dirithromycin and its related substances was studied and the unknown impurities occurring in commercial samples were investigated. In total the structures of nine impurities were elucidated, among which three were different analogues with a modification in the side chain on the oxazine ring. Two impurities showed a different alkyl group in position C13. In two impurities the desosamine sugar was involved with changes in the degrees of methylation of the amino group. One unknown impurity was identified as dirithromycin F and another unknown was characterized as dirithromycin N-oxide.

Chromatography, Liquid↗

Analysis of neomycin using an improved liquid chromatographic method combined with pulsed electrochemical detection.

An isocratic liquid chromatographic method with pulsed electrochemical detection is described for the determination of neomycin in the presence of its impurities. The mobile phase is composed of an aqueous solution containing 35 g/l of sodium sulphate, 1 g/l of sodium 1-octanesulfonate, 14 ml/l of tetrahydrofuran (THF) and 50 ml/l of 0.2 M phosphate buffer pH 3.0. Sodium hydroxide was added post column to enhance the detection. An investigation of different reversed-phase columns indicated that the Discovery (C18 5 microm, 250 mm x 4.6 mm I.D.) column was the most suitable. The proposed method shows high efficiency, allowing the separation of the main component neomycin B from neomycin C and 15 other impurities. A central composite design was used to assess the robustness of the method. The method showed good selectivity, repeatability, linearity and sensitivity. This method was applied to analyse commercial samples.

Anti-Bacterial Agents↗

Evaluation of an International Pharmacopoeia method for the analysis of indinavir sulfate by liquid chromatography.

A gradient LC method for the determination of indinavir sulfate (IDV) and its impurities has been recently published in a consultation document of the International Pharmacopoeia, WHO Drug Information. The method uses a base-deactivated reversed-phase C18 column (25 cm x 4.6 mm i.d.), 5 microm kept at a temperature of 40 degrees C. The mobile phases consist of acetonitrile, phosphate buffer pH 7.5 and water. The flow rate is 1.0 ml/min. UV detection is performed at 220 nm. A system suitability test (SST) is described to govern the quality of the separation. The separation towards IDV components was investigated on 16 C18 columns and correlation was made with the column classification system developed in our laboratory. The method was evaluated using a Hypersil BDS C18 column (25 cm x 4.6 mm i.d.), 5 microm. A central composite design was applied to examine the robustness of the method. The method shows good precision, linearity, sensitivity and robustness. Six commercial samples were examined using this method.

Chromatography, Liquid↗

Determination of stigmasterol, beta-sitosterol and stigmastanol in oral dosage forms using high performance liquid chromatography with evaporative light scattering detection.

A validated and repeatable high performance liquid chromatography (HPLC) method with online evaporative light scattering (ELSD) was developed for the analysis of two sterols, stigmasterol, beta-sitosterol and a stanol, stigmastanol, found to be common in many herbal formulations and health care supplements. The method is based on the separation of the three marker compounds on a C8 column (Phenomenex Luna, 5 microm, 150 mmx4.6 mm i.d.) using methanol:water (95:5 v/v) as the mobile phase, and a flow rate of 1 ml/min to separate all the marker compounds within 12 min. Cholesterol (50 microg/ml) was used as internal standard and methanol as the extraction solvent. The ELSD response parameters were optimised and the limits of detection (LOD) and quantification (LOQ) were calculated to be 2 and 5 microg/ml, respectively, which is more sensitive than obtained by photo diode array detection (5 and 7 microg/ml). Using ELSD, the percentage relative standard deviation (%R.S.D.) of intra-day and inter-day (3 days) precision for each marker was better than 3%, the accuracy data were within 97-103% and the recovery data were found to be within 95-107% for the five commercially available products examined. This method was used to assay commercially available products formulated as oral dosage forms purported to contain African Potato and associated sterols and stanol and proved to be suitable for the routine analysis and quality control of such products.

Administration, Oral↗

Investigation of vancomycin and related substances by liquid chromatography/ion trap mass spectrometry.

Liquid chromatography (LC) methods compatible with mass spectrometry (MS) that are suitable for impurity profiling of vancomycin mixtures have not been described in the literature. The mobile phases of the existing methods contain non-volatile additives and/or solvents that give problems in combination with MS. In this paper, a reversed-phase LC/tandem mass spectrometry method is described for the investigation of vancomycin and related substances. The LC method uses a Zorbax Extend C18 column (250 x 4.6 mm i.d.), 5 microm, and a mobile phase consisting of methanol, water and ammonium acetate solution (pH 9.0). This method allows us to separate vancomycin and its impurities. Mass spectral data are acquired on an LCQ ion trap mass spectrometer equipped with an electrospray interface operated in the positive and negative ion modes. The LCQ is ideally suited for identification of impurities and related substances because it provides on-line LC/MSn capability, which allows efficient identification without time-consuming isolation and purification procedures. Using this method, the fragmentation of vancomycin and known derivatives was studied and the structures of six substances occurring in commercial samples were elucidated.

Anti-Bacterial Agents↗

Improved LC of minocycline drug substance.

An isocratic liquid chromatographic method is described for the separation of minocycline and its impurities. This method uses XTerra RP-18, 5 microm (25 cm x 4.6 mm I.D.), a silica-based stationary phase with reduced silanol activity. A mobile phase composed of acetonitrile-0.2 M tetrabutylammonium hydrogen sulphate pH 6.5-0.2 M ethylenediaminetetraacetic acid pH 6.5-water (20:20:20:40; v/v/v/v) was used at a flow rate of 1 ml/min. The column temperature was set at 35 degrees C. UV detection was performed at 280 nm. Optimisation of the separation method and a robustness study were performed by means of a central composite experimental design. The method allows to separate minocycline from known impurities. Some unidentified impurities are also separated. The total time of analysis is less than 20 min.

Anti-Bacterial Agents↗

Evaluation of the stability of chlortetracycline in granular premixes by monitoring its conversion into degradation products.

A methodology for the evaluation of the stability of chlortetracycline (CTC) in granular premixes is described. This methodology is based on the monitoring of the conversion of CTC into its degradation products by an improved gradient liquid chromatography (LC) method, based on one previously described by our laboratory. Sample preparation involves the extraction of CTC and its degradation products prior to LC analysis, using acidified methanol as extraction solvent. The gradient elution LC method proved to be very sensitive, especially towards the late eluting anhydro derivatives. The use of a Hypersil C8 BDS, 5 microm, 250 mm x 4.6 mm i.d. column is recommended since this column allowed a complete separation of the different impurities from each other and from the main component CTC. The applicability of this approach was demonstrated by the analysis of stability samples.

Anti-Bacterial Agents↗

Development of a liquid chromatographic method for ear drops containing neomycin sulphate, polymyxin B sulphate and dexamethasone sodium phosphate.

Two liquid chromatographic methods were developed to analyse ear drops containing neomycin sulphate, polymyxin B sulphate and dexamethasone sodium phosphate. This formulation will be described in the Belgian National Formulary. Since neomycin, an aminoglycoside antibiotic, has no UV chromophore and pre or post column derivatization is complicated, pulsed electrochemical detection on a gold electrode was chosen to determine neomycin. Polymyxin B sulphate and dexamethasone sodium phosphate do have a UV chromophore. So, a single LC method with UV detection was developed for the determination of polymyxin B sulphate and dexamethasone sodium phosphate. The sample pretreatment is simply done by diluting the formulation with water. For each method, the influence of the different chromatographic parameters on the separation, the interference of other active compounds and excipients, the repeatability and the linearity were investigated. Finally, the content of the actives in the formulation was studied at 0, 2, 4, 6, and 8 weeks.

Chemistry, Pharmaceutical↗

Analysis of purity in 19 drug product tablets containing clopidogrel: 18 copies versus the original brand.

In this study, 18 copies of PLAVIX tablets containing clopidogrel hydrogensulfate were compared to the innovator drug product for uniformity of mass, impurity profile, content, dissolution properties and stability. In order to be able to separate the R-enantiomer of clopidogrel, an enantiospecific liquid chromatographic method was used to determine the impurities and to perform the assay. The paddle method was used for dissolution testing. Most of the copies were not similar compared to the original drug product: their amount of impurities was higher, the content of clopidogrel lower, the dissolution profiles different and after 3 months under stress conditions in the original packaging, the results for the samples and the reference were significantly different in most of the cases.

Chromatography, High Pressure Liquid↗

Analysis of erythromycin and benzoylperoxide in topical gels by liquid chromatography.

Gels containing a combination of erythromycin and benzoylperoxide are frequently used in the treatment of acne vulgaris. A method was developed to determine the content of both erythromycin and benzoylperoxide in these gels. Erythromycin was extracted from the gel in conditions where the oxidative power of benzoylperoxide was neutralised by addition of ascorbic acid and this extract was analysed on an Xterra RP(18) column, with a mobile phase containing acetonitrile-0.2 M K2HPO4-water (35:5:60, v/v/v). The detection wavelength was 215 nm. A second extraction procedure was developed for the analysis of benzoylperoxide. The extraction solution was analysed on a Hypersil C(18) BDS column and a mobile phase containing acetonitrile-water (58:42, v/v). Detection was performed at 254 nm. The flow rate was 1.0 ml/min in both methods. The selectivity, repeatability, linearity and recovery of both methods were examined. Special attention was given to determination of the recovery and the uncertainty on the recovery. This allowed evaluation of the bias of the extraction method. The method developed was used to examine the stability of a gel for topical use.

Administration, Topical↗

Hyphenation of liquid chromatography to ion trap mass spectrometry to identify minor components in polypeptide antibiotics.

The application of liquid chromatography-ion trap mass spectrometry for the characterization of linear and cyclic polypeptide antibiotics was investigated. The aim was on-line identification of impurities in those antibiotic complexes without recourse to time-consuming isolation and purification procedures. Hyphenated techniques, such as liquid chromatography coupled to mass spectrometry, are ideally suited for this purpose. Characterization was performed with an ion trap mass spectrometer offering MS(n) capability; this enables more structural information to be obtained. Liquid chromatography in combination with ion trap mass spectrometry was successfully applied for the characterization of impurities in gramicidin, polymyxin B, polymyxin E, and bacitracin and the study of the degradation products of polymyxins B and E.

Amino Acid Sequence↗

Interlaboratory study of a liquid chromatography method for erythromycin: determination of uncertainty.

Erythromycin is a mixture of macrolide antibiotics produced by Saccharopolyspora erythreas during fermentation. A new method for the analysis of erythromycin by liquid chromatography has previously been developed. It makes use of an Astec C18 polymeric column. After validation in one laboratory, the method was now validated in an interlaboratory study. Validation studies are commonly used to test the fitness of the analytical method prior to its use for routine quality testing. The data derived in the interlaboratory study can be used to make an uncertainty statement as well. The relationship between validation and uncertainty statement is not clear for many analysts and there is a need to show how the existing data, derived during validation, can be used in practice. Eight laboratories participated in this interlaboratory study. The set-up allowed the determination of the repeatability variance, s(2)r and the between-laboratory variance, s(2)L. Combination of s(2)r and s(2)L results in the reproducibility variance s(2)R. It has been shown how these data can be used in future by a single laboratory that wants to make an uncertainty statement concerning the same analysis.

Anti-Bacterial Agents↗

Determination of kanamycin in serum by solid-phase extraction, pre-capillary derivatization and capillary electrophoresis.

An effective method based on solid-phase extraction (SPE) and capillary electrophoresis (CE) for the determination of kanamycin in human serum was developed and validated. Off-line SPE was employed for the isolation of kanamycin from serum on a carboxypropyl-bonded phase (CBA) weak cation-exchange cartridge. A mixture of 0.2 M borate (pH 10.5)-methanol (50:50, v/v) was used as analyte eluting solvent. After pre-capillary derivatization with o-phthalaldehyde/mercaptoacetic acid reagent, the sample was analyzed by CE with a separation buffer of 30 mM borax, pH 10.0, containing 16% (v/v) methanol. A linear response over the concentration range 5-40 microgram/ml was obtained with a detection limit of 2 microgram/ml. Intra-day and inter-day precision were 6.2 and 10.3% RSD, respectively. Recoveries of approximately 90% were found. For the determination of lower levels of kanamycin (<5 microgram/ml), NH(4)OH (25%, w/v)-methanol (30:70, v/v) was used for analyte elution. After evaporation, reconstitution and derivatization, the sample was analyzed by on-line field-amplified sample stacking (FASS) CE. Good linearity in the concentration range 0.4-5 microgram/ml was obtained with a detection limit of 0.1 microgram/ml. Intra-day and inter-day RSD were 3.4 and 11.2%, respectively. Recoveries of approximately 60% were found. The method was successfully applied to the analysis of kanamycin in sera of tuberculosis patients at peak level and trough level concentrations.

Anti-Bacterial Agents↗

Analysis of unknown compounds in azithromycin bulk samples with liquid chromatography coupled to ion trap mass spectrometry.

A selective reversed-phase liquid chromatography/mass spectrometry (LC/MS(n)) method is described for the identification of azithromycin impurities and related substances in commercial azithromycin samples. Mass spectral data are acquired on an LCQ ion trap mass spectrometer equipped with an atmospheric pressure chemical ionization interface operated in positive ion mode. The LCQ provides on-line LC/MS(n) capability, making it ideally suited for identification purposes. In comparison with UV detection, this hyphenated technique provides as its main advantage efficient identification of novel substances without time-consuming isolation and purification procedures. Using this technique, six novel related substances detected in commercial azithromycin samples have been studied.

Anti-Bacterial Agents↗

Analysis of a formulation containing lincomycin and spectinomycin by liquid chromatography with pulsed electrochemical detection.

A reversed phase ion-pair liquid chromatographic method using a base deactivated column and pulsed electrochemical detection on a gold electrode is described. It allows the separation of a mixture of spectinomycin sulfate, lincomycin hydrochloride and their related substances. A step gradient was necessary to obtain a good separation together with a reasonable analysis time of 40 min. The mobile phases consisted of an aqueous solution of 3.3 or 0.55 g/l pentanesulfonic acid, 10 mM acetic acid and 20 ml/l tetrahydrofuran. Both mobile phases were adjusted to pH 4.0 with diluted sodium hydroxide. The influence of the different chromatographic parameters on the separation was investigated. Two commercial samples were analyzed using the described method. In total 12 components could be separated.

Anti-Bacterial Agents↗

Study of the stability of polymyxins B(1), E(1) and E(2) in aqueous solution using liquid chromatography and mass spectrometry.

Polymyxins B(1), E(1) (colistin A) and E(2) (colistin B) were subjected to degradation in aqueous solutions of different pH values (1.4, 3.4, 5.4 and 7.4) and at different temperatures (37, 50 and 60 degrees C) in order to investigate the characteristics of decomposition. The progress of decomposition was followed by reversed-phase liquid chromatography on YMC-Pack Pro, C-18 stationary phase. The degradation curves showed (pseudo) first order kinetics. The pH-rate profiles indicate that colistin is more susceptible to degradation in solutions of pH above 5 and is more stable in acidic media. The degradation of polymyxin B(1) was most rapid at pH 7.4. Qualitative analysis of the degradation products by LC/MS reveals that racemization is the major mechanism of degradation in both acidic and neutral media.

Anti-Bacterial Agents↗

Isocratic liquid chromatographic method for the analysis of azithromycin and its structurally related substances in bulk samples.

An isocratic liquid chromatographic method with UV detection at 215 nm, which is suitable for the analysis of azithromycin (AZT) in bulk samples, is described. AZT is separated from its synthesis intermediates and a degradation product as well as from six unknown impurities on an XTerra RP18 column at 70 degrees C using a mobile phase consisting of acetonitrile-pH 6.5 0.2M K2HPO4-water (35:10:55, v/v/v) at 1.0 mL/min. The XTerra stationary phase contains methyl groups that are incorporated in the bulk structure of the material. This allows for special selectivities. Robustness is evaluated by a full factorial design experiment. The method shows good selectivity, repeatability, linearity, and sensitivity.

Anti-Bacterial Agents↗