PubMed Health⌕ Search

Biomedical subjects

J Hornegger

Publications and source records attributed to J Hornegger.

4 recordsLinked to original sources

Retrospective interactive rigid fusion of (18)F-FDG-PET and CT. Additional diagnostic information in melanoma patients.

AIM: This study investigates whether interactive rigid fusion of routine PET and CT data improves localization, detection and characterization of lesions compared to separate reading. For this purpose, routine PET and CT scans of patients with metastases from malignant melanoma were used. PATIENTS, METHODS: In 34 patients with histologically confirmed malignant melanoma, FDG-PET and spiral CT were performed using clinical standard protocols. For all of these patients, gold standard was available. Clinical and radiological follow-up identified 82 lesions as definitely pathological. Two board-certified nuclear medicine physicians and two board-certified radiologists analyzed PET and CT images independently from each other. For each patient up to 32 anatomical regions (24 lymph node regions, 8 extranodular regions) were systematically classified. Discordant areas were interactively analyzed in manually and rigidly registered images using a commercially available fusion tool. No side-by-side reading was performed. RESULTS: Image fusion disclosed that the evaluation of the PET images alone led to a mislocalization in 26 of 91 focally FDG enhancing lesions. The overall sensitivities of PET, CT, and image fusion were 85, 88, and 94%, respectively; the overall specificities of PET, CT and image fusion were 98, 95 and 100%, respectively. Image fusion exhibited statistically significant higher specificity values as compared with CT. Ten definitely malignant sites were false-negative in CT, but could be detected by PET. On the other hand, twelve metastases were false-negative in PET, but could be detected by CT. These included two lesions, which had a clear correlate on the PET image when the fused images were evaluated. On the whole, registration of the PET and CT images yielded additional diagnostic information in 44% of the definitely malignant lesions. CONCLUSION: Retrospective image fusion of independently obtained PET and CT data is particularly valuable in exactly localizing foci of abnormal FDG uptake and improves the detection of metastases of malignant melanoma.

Adult↗

[Anatomical accuracy of lesion localization. Retrospective interactive rigid image registration between 18F-FDG-PET and X-ray CT].

UNLABELLED: The aim of this study was to evaluate the anatomical accuracy and reproducibility of retrospective interactive rigid image registration (RIR) between routinely archived X-ray computer tomography (CT) and positron emission tomography performed with 18F-deoxyglucose (FDG-PET) in oncological patients. METHODS: Two observers registered PET and CT data obtained in 37 patients using a commercially available image fusion tool. RIR was performed separately for the thorax and the abdomen using physiological FDG uptake in several organs as a reference. One observer performed the procedure twice (O1a and O1b), another person once (O2). For 94 malignant lesions, clearly visible in CT and PET, the signed and absolute distances between their representation on PET and CT were measured in X-, Y-, and Z-direction with reference to a coordinate system centered in the CT representation of each lesion (X-, Y-, Z-distances). RESULTS: The mean differences of the signed and absolute distances between O1a, O1b, and O2 did not exceed 3 mm in any dimension. The absolute X-, Y-, and Z-distances ranged between 0.57 +/- 0.58 cm for O1a (X-direction) and 1.12 +/- 1.28 cm for O2 (Z-direction). When averaging the absolute distances measured by O1a, O1b, and O2, the percentage of lesions misregistered by less than 1.5 cm was 91% for the X-, 88% for the Y-, and 77% for the Z-direction. The larger error of fusion determined for the remaining lesions was caused by non-rigid body transformations due to differences in breathing, arm position, or bowel movements between the two examinations. Mixed effects analysis of the signed and absolute X-, Y-, and Z-distances disclosed a significantly greater misalignment in the thorax than in the abdomen as well as axially than transaxially. CONCLUSION: The anatomical inaccuracy of RIR can be expected to be <1.5 cm for the majority of neoplastic foci. Errors of alignment are bigger in the thorax and in Z-direction, due to non-rigid body transformations caused, e.g., by breathing.

Fluorodeoxyglucose F18↗

A linear programming approach to limited angle 3D reconstruction from DSA projections.

OBJECTIVES: We investigate the feasibility of binary-valued 3D tomographic reconstruction using only a small number of projections acquired over a limited range of angles. METHODS: Regularization of this strongly ill-posed problem is achieved by (i) confining the reconstruction to binary vessel/non-vessel decisions, and (ii) by minimizing a global functional involving a smoothness prior. RESULTS: Our approach successfully reconstructs volumetric vessel structures from three projections taken within 90 degrees. The percentage of reconstructed voxels differing from ground truth is below 1%. CONCLUSION: We demonstrate that for particular applications--like Digital Subtraction Angiography--3D reconstructions are possible where conventional methods must fail, due to a severely limited imaging geometry. This could play an important role for dose reduction and 3D reconstruction using non-conventional technical setups.

Angiography, Digital Subtraction↗

Multiplanar reconstructions and three-dimensional imaging (computed rotational osteography) of complex fractures by using a C-arm system: initial results.

With use of a calibrated angiographic C-arm system and a postprocessing workstation, the authors acquired volume data sets from two-dimensional digital projection images obtained during a C-arm rotation around the patient axis. Multiplanar reconstruction and three-dimensional images of complex fractures were reconstructed and compared with spiral computed tomographic studies in a cadaveric pig study and in eight patients. Computed rotational osteography provided high-resolution multiplanar reconstruction and three-dimensional images of complex fractures.

Animals↗