PubMed Health⌕ Search

Biomedical subjects

J J Berzas Nevado

Publications and source records attributed to J J Berzas Nevado.

At least 19 recordsLinked to original sources

Screening of citalopram, fluoxetine and their metabolites in human urine samples by gas chromatography-mass spectrometry. A global robustness/ruggedness study.

Capillary gas chromatography with mass spectrometry detection in SIM mode (GC-MS-SIM) has been used for the analysis of citalopram (CIT), fluoxetine (FLX), and all of their metabolites in urine samples. The instrumental parameters affecting GC separation and MS-SIM detection were investigated. A validation procedure was performed on urine matrix and a simultaneous robustness/ruggedness evaluation is also presented in this paper. An optimized solid-phase extraction (SPE) has been applied, reaching in this way to limits of detection (LODs) between 0.7 ng L(-1) (CIT) and 33.6 microg L(-1) (CIT-PA). A pharmacokinetic screening in clinical urine samples has been also carried out.

Citalopram↗

Determination of ibuprofen and tetrazepam in human urine by micellar electrokinetic capillary chromatography.

A new micellar electrokinetic capillary chromatography method (MEKC) is proposed for the determination of ibuprofen and tetrazepam in human urine samples over a concentration range of therapeutic interest. A fused silica capillary (60 cm x 75 microm) is used. Ibuprofen and tetrazepam are detected via UV detection at 220 and 228 nm, respectively. Separation is performed at 25 degrees C and at a separation voltage of 30 kV, with 15 mM borate buffer (pH 10.2) containing 40 mM sodium dodecylsulfate as the electrolyte solution. Under these conditions the analytes were separated in <11 min. Sulfamethazine is used as an internal standard. Prior to determination, the samples are purified and enriched by means of an extraction-preconcentration step with a preconditioned C18 cartridge and by eluting the compounds with methanol. Good linearity, accuracy, precision, robustness and solution stability were achieved for the technique. Detection limits of 200 microg L(-1) for ibuprofen and 300 microg L(-1) for tetrazepam were obtained. These analytes were then determined in real urine using the technique.

Benzodiazepines↗

Assay validation for three antidepressants in pharmaceutical formulations: practical approach using capillary gas chromatography.

An easy and fast capillary gas chromatographic FID method, which was already described by the same authors for the simultaneous determination of fluoxetine, fluvoxamine and clomipramine without derivatization step, is now submitted to a validation procedure in several pharmaceutical formulations. Main aspects of the validation method are examined and discussed, since methods for regulatory submission in most cases must demonstrate: specificity in presence of all potential components, concentration range over which the response is lineal, accuracy, precision, acceptable detection and quantitation limits and stability of the procedure. The pharmaceutical preparations subject of validation were: 'Prozac' (capsules), 'Dumirox' (tablets) and 'Anafranil' (tablets) containing fluoxetine, fluvoxamine and clomipramine, respectively. The results presented in this report show the applied gas chromatographic method is acceptable for the determination of the three antidepressants in the pharmaceutical formulations above mentioned.

Antidepressive Agents↗

Nonaqueous capillary electrophoresis method for the analysis of gleevec and its main metabolite in human urine.

The viability of nonaqueous capillary electrophoresis (NACE) was investigated for determination of gleevec and its main metabolite in human urine using a fused-silica capillary. Baseline separation of the studied solutes was obtained using a nonaqueous solution composed of 12 mM ammonium acetate and 87.6 mM acetic acid in methanol-acetonitrile (ACN) (80:20, v:v) providing analysis time shorter than 3 min. Different aspects including stability of the solutions, linearity, accuracy and precision were studied in order to validate the method in the urine matrix. Detection limits of 24 microg L(-1) for gleevec and its metabolite were obtained. A robustness test of the method was carried out using the Plackett-Burman fractional factorial model with a matrix of 15 experiments. The developed method is simple, rapid and sensitive and has been used to determine gleveec and its metabolite at clinically relevant levels in human urine. Before NACE determination, a solid-phase extraction (SPE) procedure with a C18 cartridge was necessary. Real determination of these analytes in two patient urines were done.

Antineoplastic Agents↗

Development of a Micellar electrokinetic capillary chromatography method for the determination of three drugs employed in the erectile dysfunction therapy.

A Micellar electrokinetic capillary chromatography method is proposed for the determination of sildenafil, vardenafil and tadalafil, which are employed in oral therapy for erectile dysfunction. Optimum conditions for the separation were investigated. A background electrolyte solution consisting of 10 mM phosphate buffer adjusted to pH 12.0, sodium dodecyl sulfate (SDS) 25 mM, hydrodynamic injection, and 25 kV as separation voltage were used. Relative standard deviations (R.S.D.s) were 1.0, 1.0, 0.4% and 2.9, 2.9, 1.9% for migration time and corrected peak area (CPA) (n = 9) for sildenafil, vardenafil and tadalafil, respectively. Detection limits obtained for the three drugs ranged from 0.19 to 0.61 mg L(-1). A linear concentration range between 1 and 20 mg L(-1) was obtained. A ruggedness test of this method was checked using the fractional factorial model of Plackett-Burman, in which the influence of six factors at three different levels was tested on different electrophoretic results: resolution and corrected peak area. The statistical evaluation of the electrophoretic results was achieved by Youden and Steiner method. The described method is rapid, sensitive and rugged and it was tested in the pharmaceutical formulations analysis obtaining recoveries between 98 and 107% respect to the nominal content.

Carbolines↗

Distribution of mercury in the aquatic environment at Almadén, Spain.

The world's largest mercury mine is placed at Almadén, Spain. However, there is a lack of information about the environmental impact of these mining activities in the ecosystem that surrounds this area. The aim of this article is to document the concentration of mercury in waters, sediments and bivalves of the aquatic system impacted by historic mine wastes. Simultaneously, a comprehensive study has been undertaken to characterise this hydrosystem and to determine the influence of some major physico-chemical parameters on the fate of mercury. Samplings were carried out for the last few years. Concentration of mercury in waters ranged from not detectable to 20 microg/l. For the sediments study, samples have been taken both from contaminated and non-contaminated sites within the basin. The regional background mercury concentration is higher than values typically cited for natural backgrounds. At exposed sites the mercury concentrations between 5 and 1000 microg/g were measured. These values are one to four order of magnitude greater than regional background levels. In the comparison between the results obtained at the present moment and those available for the 1974-1977 period, a general diminution of mercury levels is observed. Mercury concentrations in fresh water bivalves ranged between 1 and 4 microg/g (d.w.), with around 30% as monomethylmercury. In the discussion of the implications for risk assessment data available for other areas affected both for mine activities and mercuriferous belt are included.

Animals↗

Determination of lormetazepam and its main metabolite in serum using micellar electrokinetic capillary chromatography with direct injection and ultraviolet absorbance detection.

The use of micellar electrokinetic chromatography for the determination of lormetazepam and its metabolite, lorazepam, in serum samples at a concentration range of therapeutic interest was investigated. The separation was carried out at 30 degrees C and 25 kV, using a 15 mM borate-phosphate buffer (pH 8) with 30 mM sodium dodecyl sulfate as the separation electrolyte and 15% methanol as organic modifier. The analyses were carried out in 20 min under these conditions. Detection limits of 0.5 mg l(-1) were achieved for both benzodiazepines in serum. This method was employed for the quantitative resolution of both drugs (at different concentration ratios) in serum with very good recoveries.

Anti-Anxiety Agents↗

Determination of sildenafil citrate and its main metabolite by sample stacking with polarity switching using micellar electrokinetic chromatography.

Micellar electrokinetic capillary chromatography (MEKC) coupled with sample stacking and polarity switching was investigated for the determination of Viagra (sildenafil citrate, SC) and its metabolite (UK-103,320, UK) in human serum in the concentration range of clinical interest. Human serum samples spiked with SC and UK were eluted with methanol from a C18 cartridge, the extract was evaporated and regenerated in a solution that contained 1 mM phosphate buffer (pH 12.3) and 20% methanol. The MEKC separation was performed using an injection time of 275 s, a polarity switching time of 93 s, a phosphate buffer, (pH 12.3, 15 mM) containing 25 mM sodium dodecyl sulfate as separation electrolyte and a fused-silica capillary. The analysis takes about 6 min and gives satisfactory inter-day precision with respect to migration times and linear responses over the 80-900 ng/ml concentration range investigated for SC and UK. Intra-day RSDs (n=4 graphs) for the slopes of the calibration graphs were 4.86% for SC and 3.50% for UK. Inter-day RSDs for the slopes were 4.37% for SC and 5.39% for UK. Detection limits (S/N=3) were about 17 ng/ml for both compounds in human serum. A 1-ml volume of blood serum was necessary to do this determination.

Calibration↗

Micellar electrokinetic capillary chromatography for the determination of fluoxetine and its metabolite norfluoxetine in biological fluids.

A micellar electrokinetic capillary chromatography (MEKC) for determining fluoxetine and its metabolite (norfluoxetine) is proposed. Optimal conditions for the quantitative separation were investigated. A background electrolyte solution consisting of 5 mM phosphate buffer adjusted to pH 12.3 and 40 mM of 1-decanesulfonic acid sodium salt (DSS), hydrodynamic injection and 25 kV of separation voltage were used. Good linearity and precision were obtained for both compounds. Detection limits of 0.2 mg/l for fluoxetine and norfluoxetine were obtained. The developed method is rapid and it has been applied to determine fluoxetine and its metabolite in human serum and urine. The samples were purified and enriched by means of extraction-preconcentration step with a preconditioned C18 cartridge and eluting the compounds with methanol.

Chromatography, Micellar Electrokinetic Capillary↗

Determination of sulfametoxazole, sulfadiazine and associated compounds in pharmaceutical preparations by capillary zone electrophoresis.

A capillary zone electrophoresis method is presented to separate sulfadiazine, sulfamethoxazole, trimethoprim, bromhexine and guaiacol by using a fused-silica capillary (60.2 cm x 75 microm I.D.). The separation was carried out at 30 kV and 25 degrees C in a 15 mM phosphate buffer adjusted to pH 6.2 as electrolyte. Under these conditions, the run time was 6 min and the limits of quantification were about 1 mg/l for every component. The method was applied to pharmaceutical preparations and the results provided recoveries close to 100%.

Anti-Infective Agents↗

Micellar electrokinetic capillary chromatography for the determination of Viagra and its metabolite (UK-103,320) in human serum.

Micellar electrokinetic capillary chromatography (MEKC) was investigated for the determination of Viagra (sildenafil citrate, SC) and its metabolite (UK-103,320) in human serum in a concentration range of clinical interest. For MEKC, human serum samples spiked with SC and UK were obtained directly after elution with methanol from a tC18 cartridge. The extract was evaporated and regenerated in a solution 1 mM of phosphate buffer (pH 12.3) which contained a methanol percentage of 20% that was analyzed using phosphate buffer (pH 12.3, 10 mM) containing 30 mM sodium dodecyl sulfate (SDS) as separation electrolyte and a fused-silica capillary. This method gave satisfactory interday precision with respect to migration times relative standard deviation (RSD < 1%) and linear responses for the concentration ranges investigated (0.50-3.50 mg L(-1) for the compound SC and 0.90-4.60 mg L(-1) for UK). An intraday RSD (n = 5 graphs) between the slopes of the calibration graphs was acceptable (6.40%) for SC and (3.37%) for UK. A satisfactory interday precision between slopes was also obtained (RSD 4.10% for SC and a RSD 2.72% for UK) which demonstrated the ruggedness of this method. Detection limits (S/N = 3) were about 200 ng/mL for both compounds in human serum. MEKC was shown as a good method with regards to simplicity, precision and sensitivity.

Electrophoresis, Capillary↗

Simultaneous determination of sulfaquinoxaline, sulfamethazine and pyrimethamine by liquid chromatography.

A liquid chromatography method is described to determine sulfaquinoxaline (SQX), sulfamethazine (SMT), and pyrimethamine (PMT), by using a Kromasil C18 column and a 40 mM NaH2PO4 buffer solution, containing 10 mM NaClO4 (pH 3.0)-acetonitrile (65:35) as mobile phase. The mobile phase flow-rate and sample volume injected were 1.5 ml/min and 20 microl, respectively and the samples were dissolved in the mobile phase. The limits of quantification were found to be about 180 microg/l (3.6 ng) for each compound. The method was applied in veterinary commercial formulations. Analyses were made by means of the standard addition method, whose results were compared with those obtained by preparing "tests" (from the stock solutions) and with those obtained by a capillary electrophoresis method. Both methods showed similar results, and then it was proved that some commercial claimed levels were not in agreement with the obtained results by using our analytical method, as they were in other cases.

Anti-Infective Agents↗

Determination of fluoxetine, fluvoxamine, and clomipramine in pharmaceutical formulations by capillary gas chromatography.

A simple and fast capillary gas chromatographic method with flame ionization detection is proposed for the simultaneous determination of fluoxetine, fluvoxamine, and clomipramine without a prederivatization. The reported method is the first one that allows the determination of three selective serotonin reuptake inhibitors. Optimal conditions for the quantitative separation were investigated: column head pressure (80 kPa), injector and detector temperatures (260 and 250 degrees C), time and temperature for the splitless step (0.75 min and 60 degrees C), size of sample (2 microL), and oven temperature program, providing analysis times shorter than 10 min. Aspects such as the stability of the solutions, linearity, accuracy, and precision are examined in order to validate this method. Peak purity and detection and quantitation limits are also assessed using mass selective detection. The scope of the validated method is tested in the analysis of pharmaceutical preparations, with recoveries between 97.5 and 102.5% with regard to their nominal contents.

Chromatography, Gas↗

Simultaneous determination of cis- and trans-resveratrol in wines by capillary zone electrophoresis.

A capillary zone electrophoresis method for determining cis- and trans-resveratrol isomers is proposed. Optimal conditions for the quantitative separation were investigated. A background electrolyte solution consisting of 40 mM borate buffer adjusted to pH 9.5, hydrodynamic injection and 5 kV of separation voltage were used. Good linearity and precision were obtained for the two isomers. Detection limits of 0.06 mg L-1 for trans-resveratrol and 0.08 mg L-1 for cis-reveratrol were obtained. The developed method is rapid and sensitive and it has been applied to determine cis- and trans-resveratrol in several red wines. The samples were purified and enriched by passing them through a preconditioned C18 cartridge and eluting the isomers with acetonitrile-water (3 + 7).

Anticarcinogenic Agents↗

Flow-injection spectrophotometric determination of adrenaline and dopamine with sodium hydroxide.

A new, rapid and economical flow-injection method for determining adrenaline and dopamine is proposed on the basis of the hydrolysis of these compounds in alkaline medium. The method was optimized by using a spectrophotometer operating at lambda = 390 nm as detector. Calibration graphs were linear up to 2 x 10(-4) M with quantification limits of 2.5 x 10(-6) M and 3.3 x 10(-6) M for dopamine and adrenaline respectively. Flow-injection allows the measurement of 130 samples per hour. The method was successfully applied for the determination of catecholamines in pharmaceuticals.

Chemistry, Pharmaceutical↗

Determination of pyridoxal in human serum by matrix isopotential synchronous fluorescence spectrometry.

The determination of pyridoxal in human serum was performed using a fluorimetric technique that is useful for the determination of compounds in samples with unknown background fluorescence, based on synchronous scans through a trajectory joining points of equal intensity of a fluorescence matrix three-dimensional spectrum. This technique, called matrix isopotential synchronous fluorescence can be improved by means of the application of derivatives. The determination of pyridoxal in human serum was performed with this technique without any prior separation steps. The validity, applicability and simplicity of the method were demonstrated. The measurements were performed in aqueous medium at pH 7.0 adjusted by adding 0.05 M phosphate buffer solution. A complete statistical analysis of the experimental data was performed and the results showed that correlation coefficients are between 0.9901 and 0.9958 for all the calibration graphs, and in all cases the intercepts on the ordinate were negligible. The experimental F (1.72) is smaller than theoretical value (3.89) as expected from an analysis of variance. The reproducibility of the method was tested and the results were a standard deviation of 0.0117 microgram ml-1 and a relative error of 4.91%.

Humans↗

Determination of pyridoxamine in urine by matrix isopotential synchronous fluorescence spectrometry.

A spectrofluorimetric technique was applied to the determination of compounds in samples with unknown background fluorescence, consisting of performing synchronous scans through a trajectory joining points of equal intensity of a fluorescence matrix three-dimensional spectrum, which is called 'matrix isopotential synchronous fluorescence'. This technique can be improved by application of derivatives. The determination of pyridoxamine in urine was performed using this technique and the validity, applicability and simplicity of the method were demonstrated. With first-derivative matrix isopotential synchronous fluorescence the maximum sensitivity was 12.5 mg l-1 for pyridoxamine in real urine samples. The measurements were performed in aqueous medium at pH 7.0, adjusted by adding 0.05 mol l-1 phosphate buffer, and without any previous derivatization reactions. A complete statistical analysis of the experimental data was performed. Pyridoxamine in urine was determined by this method with good results and without the need for tedious prior separation.

Adolescent↗