Pulse-spray thrombolysis with reteplase: optimization and comparison with tPA in a rabbit model.

PURPOSE: To critically evaluate and optimize methodology for pulse-spray thrombolysis with reteplase in a rabbit inferior vena cava (IVC) thrombosis model and to compare results with optimized parameters for the use of tissue plasminogen activator (tPA). MATERIALS AND METHODS: Occlusive IVC thrombus was produced in 102 rabbits and treated 2 days later for 1 hour with pulse-spray thrombolysis using reteplase. Methodologic variables included pulse frequency, concentration and amount of reteplase, infusion versus pulse therapy, and admixture of heparin. After the rabbits were killed, residual thrombus was weighed and percent lysis was estimated on the basis of previous control values. Results were compared with those achieved with tPA in 18 additional rabbits and also with previous tPA results. RESULTS: As in earlier tPA studies, pulse-spray methods were far more effective than constant infusion. Pulses at 30-second intervals produced better results than pulses at 2-minute intervals. At the optimal concentration of 0.02 U/mL (molarity 90 x 10(-8) ), reteplase produced 79% lysis. At two-fold higher or lower concentrations, lysis was reduced by approximately 25%, and at eight-fold higher or six-fold lower concentrations, lysis was reduced by approximately 50%. Optimal concentration of tPA was 0.02 mg/mL, yielding 78% lysis. Admixture of reteplase with heparin suggested improvement, but differences were statistically insignificant. CONCLUSION: When used with pulse-spray methodology, reteplase demonstrated a steep bell-shaped response-concentration curve similar in pitch and amplitude to that of tPA. The optimal molar concentration of reteplase was approximately three times that of tPA. However, at their respective optimal concentrations, reteplase and tPA were equally effective.

Animals↗

Augmented experimental pulse-spray thrombolysis with tissue plasminogen activator, enabling dose reduction by one or more orders of magnitude.

PURPOSE: To critically evaluate and optimize methodologic details of pulse-spray thrombolysis with tissue plasminogen activator (tPA) in a subacute rabbit inferior vena cava thrombosis model. MATERIALS AND METHODS: Occlusive inferior vena cava thrombi were produced in 104 rabbits and 2 days later were treated for 1 hour with pulse-spray thrombolysis using tPA. Methodologic variables included pulse frequency, concentration and amount of tPA, infusion versus pulse therapy, and admixture of heparin. After the rabbits were killed, residual thrombus was weighed. RESULTS: The authors' earlier standard regimen (3 mg of tPA in 6 mL of heparinized saline, 0.2-mL hand pulses, frequency 1 pulse per 2 minutes) produced 60% mean lysis. Optimization involved increasing the pulse frequency to two per minute and decreasing tPA concentration by 98% to 0.01 mg/mL, modifications that produced 22% more thrombolysis, despite 92% reduction in amount of tPA to 0.25 mg. CONCLUSION: Consistent with the in vitro work of other investigators, a roughly bell-shaped dose-response curve was elicited in vivo for pulse-spray with tPA. By diluting tPA to an optimal level, and increasing pulse frequency to two per minute, thrombolysis was markedly augmented. These results suggest that the conventional dose of tPA used for clinical pulse-spray thrombolysis can be reduced by one to two orders of magnitude, possibly markedly reducing procedural risk.

Animals↗

Percutaneous introducibility of the expandable vascular sheath system and injury potential of balloon-assisted thrombectomy: preliminary In vivo results.

PURPOSE: To test the percutaneous introducibility of the expandable vascular sheath (EVS) system and the safety of percutaneous balloon-assisted thrombectomy. METHODS: The EVS was inserted directly (n = 9) or through a 9.5 Fr regular vascular introducer sheath (n = 9) into the femoral arteries and veins and carotid arteries in four dogs (18-21 kg). Balloon-assisted thrombectomies were simulated in iliac arteries. Histologic examinations were done at sites of funnel deployment immediately (n = 4) and 25 days (n = 8) after the intervention. RESULTS: The EVS was successfully introduced into six of nine vessels by a direct percutaneous approach. Balloon-assisted thrombectomy using the EVS device caused localized intimal denudation, disruption of the internal elastic lamina, and mild hemorrhages into the media; one arterial dissection at the site of funnel deployment was seen. All indirect insertions and funnel deployments were successful. Twenty-five days after the experiments, intimal hyperplasia was noted in all cases. CONCLUSION: Percutaneous balloon-assisted thrombectomy may cause mild vascular injuries. Direct percutaneous introduction of the EVS device cannot be recommended yet.

Animals↗

Percutaneous balloon-assisted thrombectomy: preliminary in vivo results with an expandable vascular sheath system.

PURPOSE: To test an expandable vascular sheath system for percutaneous transcatheter balloon-assisted thrombectomy in vivo. MATERIALS AND METHODS: A 9-F expandable vascular sheath system was used. The system consisted of a sheath with a deployable funnel configuration and a 3-F balloon catheter used coaxially. Thrombus was created in the inferior vena cava of 24 rabbits. Thrombus with a mean weight +/- 1 standard deviation of 1,028 mg +/- 67 was removed percutaneously with the expandable sheath system at 2 days (n = 16) and 7 days (n = 8) after formation; 7-day patency was examined after removal of 2-day-old thrombus (n = 8). Histologic examination was performed in the inferior vena cava. RESULTS: In all cases of 2-day-old occlusion, complete patency of the inferior vena cava was achieved. In cases of 7-day-old occlusion, patency could be completely restored in four (50%) cases; in two (25%) cases each, there was partial removal or no thrombus could be extracted. Histologic findings were comparable with those observed after balloon embolectomy. CONCLUSION: Percutaneous transcatheter balloon-assisted embolectomy is feasible with the expandable vascular sheath system.

Animals↗

Accuracy of contrast-enhanced magnetic resonance angiography in chronic thromboembolic disease.

RATIONALE AND OBJECTIVES: We evaluated the accuracy of contrast-enhanced magnetic resonance (MR) angiography in demonstrating the findings of chronic pulmonary thromboembolism (CPTE) compared with conventional pulmonary angiography. METHODS: We examined 18 patients with CPTE proved by conventional pulmonary angiography and 16 healthy control patients. T1-weighted and single-breathhold, two-dimensional multiplanar spoiled gradient-recalled pulmonary images were obtained after injection of gadopentetate dimeglumine. Images were interpreted independently by two radiologists. RESULTS: All patients with CPTE were identified on MR angiography images by both readers. Sensitivity and specificity for MR angiography in diagnosing abnormal segments were 76% and 95% for reader 1 and 68% and 93% for reader 2, respectively. Sensitivity and specificity for MR angiography in depicting abnormal lobes were 83% and 96% for reader 1 and 82% and 93% for reader 2, respectively. Interobserver agreement was high; kappas for abnormal segments and abnormal lobes were .72 and .84, respectively. The T1-weighted spin-echo images demonstrated a mosaic signal intensity pattern in all patients with CPTE. CONCLUSION: Contrast-enhanced MR angiography accurately depicts abnormal segments and lobes in occlusive vascular disease and clearly distinguishes between patients with CPTE and those with healthy lungs.

Chronic Disease↗

Postangiographic femoral artery pseudoaneurysms: further experience with US-guided compression repair.

PURPOSE: To assess the efficacy of ultrasound-guided compression repair (UGCR) in postcatheterization femoral artery pseudoaneurysms. MATERIALS AND METHODS: One hundred thirty-three patients with pseudoaneurysms were considered for UGCR. Patients underwent compression with duplex and color Doppler ultrasound. Immediate and long-term successes were evaluated. RESULTS: Seven patients were not candidates for UGCR. UGCR was technically possible in 117 of the 126 patients who were candidates. UGCR was successful in 109 patients. The failure rate was significantly higher in patients who were receiving anticoagulant medication (P < .001). Pseudoaneurysm size, age, and structure (simple vs multiloculated) had no bearing on success or failure. The time required for successful compression was not related to treatment with anticoagulants but was related to pseudoaneurysm structure. Complications included one case of a distal embolus and two episodes of hypotension. CONCLUSION: UGCR is a simple and expedient method for the treatment of postcatheterization femoral artery pseudoaneurysms.

Aneurysm, False↗

Hand ischemia in patients with hemodialysis access grafts: angiographic diagnosis and treatment.

PURPOSE: To determine the cause of symptoms and efficacy of transcatheter therapy in a series of patients with dialysis grafts and hand pain referred for arteriography. MATERIALS AND METHODS: Thirteen patients with 14 hemodialysis grafts underwent arteriography for possible hand ischemia. The sites of proximal graft anastomosis were the distal radial artery (n = 6) and the mid- to distal brachial artery (n = 6). Transcatheter therapy was performed via the graft or by antegrade brachical puncture. RESULTS: The cause of symptoms was ischemia from obstructive arterial disease in seven cases (three with superimposed steal), graft steal alone in three, ischemic monomelic neuropathy in two, and carpal tunnel syndrome in two. Five arterial stenoses were treated with angioplasty, with improvement or resolution of symptoms in four patients. CONCLUSION: In this group, symptoms were usually the result of inflow or outflow arterial disease, alone or in combination with graft steal. Transcatheter therapy (angioplasty or embolization) is effective in selected cases.

Adult↗

Pulse-spray pharmacomechanical thrombolysis of thrombosed hemodialysis access grafts: long-term experience and comparison of original and current techniques.

OBJECTIVE: Pulse-spray pharmacomechanical thrombolysis is an evolving method for the treatment of vascular occlusions in which a highly concentrated fibrinolytic agent is injected as a high-pressure spray directly into thrombus. The purpose of this retrospective study was to analyze our long-term experience with this technique for the treatment of clotted hemodialysis grafts and to compare the efficacy and safety of the original and current methods. SUBJECTS AND METHODS: Over 6 years, 284 cases of dialysis graft thrombosis were considered suitable for treatment with pulse-spray thrombolysis. The original technique involved the injection of highly concentrated urokinase directly into a clot through two crisscross catheters with multiple side holes. The current technique includes early fragmentation of residual clot with a balloon catheter, intrathrombic injection of heparin, mechanical treatment of a lysis-resistant clot at the arterial anastomosis, and routine administration of aspirin. After thrombolysis, underlying obstructions were treated with balloon angioplasty, atherectomy, or stents. The technical success, immediate clinical success, and frequency of complications for the entire population were analyzed. In addition, the results for 36 cases treated with the original technique were compared with the results for 37 recent cases treated with the current technique. RESULTS: Of 284 cases considered suitable for treatment, thrombolysis was not done in eight cases because the venous anastomosis could not be crossed. Thrombolysis was discontinued in two cases because of extravasation of contrast material. The technical success for all grafts considered for treatment was 96%; 92% of treated grafts remained patent for at least 24 hr. Major complications occurred in 1% of cases, and minor complications occurred in 9% of cases. The clinical efficacies of the original and current techniques were 86% and 92%, respectively. The mean thrombolytic agent infusion time was reduced from 44 +/- 20 min to 23 +/- 13 min (p < .001). The overall procedure time for the recently treated subgroup was 67 +/- 26 min. There was no significant difference in the frequencies of major and minor complications between the treatment subgroups. CONCLUSION: Pulse-spray pharmacomechanical thrombolysis is a reliable, rapid, and safe method for recanalization of occluded dialysis grafts. The current technique has been proven as safe and effective as the original technique but offers the advantage of a significant reduction in the time required for the infusion of thrombolytic agent.

Anastomosis, Surgical↗

Is thrombolysis of occluded popliteal and tibial bypass grafts worthwhile?

PURPOSE: We analyzed the short- and long-term results for patients undergoing thrombolysis of occluded infrainguinal bypass grafts at our institution over a 62-month period. METHODS: Thirty-one patients with 40 episodes of graft thrombosis in 33 grafts managed by thrombolysis were retrospectively reviewed. The effects of graft age, material, and anatomy, symptoms, treatment, anticoagulation, and occlusion duration were evaluated for impact on patency after thrombolysis. Dose and duration of therapy with use of the technique of pulse-spray thrombolysis was assessed. RESULTS: Thrombolysis successfully reestablished patency in 92% of grafts treated. Mean lysis time and urokinase dose were 118 minutes and 607,000 units, respectively. Responsible lesions were identified and treated by angioplasty or surgery in 35 of 37 cases. The patency rate after thrombolysis was 28% at 30 months, and the secondary patency rate was 46% at 18 months. Duration of occlusion, symptoms, treatment, graft anatomy, and prior graft revision did not impact on patency. Mean secondary patency was 21.5 months in grafts in place over 1 year and 7.0 months in grafts in place for less than 1 year. Mean secondary patency was 23.8 months in polytetrafluoroethylene grafts and 8.4 months in vein grafts. The limb salvage rate was 84% at 30 months, and the patient survival rate was 84% at 42 months. CONCLUSIONS: Pulse-spray thrombolysis is effective in rapidly recanalizing thrombosed infrainguinal grafts. Grafts failing in the first year after placement should generally be replaced, reserving thrombolysis and revision for grafts greater than 1 year old. Vein grafts tolerate thrombosis less well than synthetic conduits and have decreased long-term patency.

Adult↗

Overdilation of the Wallstent to optimize portal decompression during transjugular intrahepatic portosystemic shunt placement.

PURPOSE: To optimize shunt size with overdilation of the Wallstent during creation of a transjugular intrahepatic portosystemic shunt (TIPS). MATERIALS AND METHODS: A TIPS was created in 25 patients with variceal bleeding (n = 22) or intractable ascites (n = 3). All shunts were created with one or more Wallstents that were dilated with an 8- or 10-mm balloon. In 11 patients with inadequate portal decompression or persistent filling of varices, shunts were overdilated with a 12-mm balloon. RESULTS: Mean portosystemic pressure gradient fell from 18.0 mm Hg +/- 6.4 (standard deviation) to 6.8 mm Hg +/- 2.8 after shunt placement. In 11 patients in which shunts were overdilated, the mean gradient fell from 12.7 mm Hg +/- 5.6 after 10-mm dilation to 6.9 mm Hg +/- 2.8 (P = .01) after 12-mm dilation. In six, variceal filling occurred after 10-mm dilation but diminished or ceased after overdilation. Stent disruption did not occur. New or worsened encephalopathy occurred in four of 14 patients with 10-mm and six of 11 patients with 12-mm shunt dilation and responded to medical therapy in all but two. CONCLUSION: Overdilation of the Wallstent during TIPS placement is effective and safe in patients with inadequate portal decompression after 10-mm shunt dilation.

Adult↗

Pulse-spray pharmacomechanical thrombolysis for treatment of thrombosed dialysis access grafts.

The results of pulse-spray pharmacomechanical thrombolysis (PSPMT) of 209 thrombosed hemodialysis grafts were reviewed. In PSPMT, concentrated urokinase is injected forcefully through catheters with multiple tiny sideholes or sideslits. Catheters placed in a crisscross fashion cover the entire clot simultaneously. This therapy was successful in treating patients with thrombosed grafts. Of the 200 grafts with complete therapy, 197 grafts (99%) were patent at the end of the procedure. Mean time for pulsed-spray lysis was 40 minutes. Etiologies for graft thrombosis were anastomotic venous outflow stenosis, stenosis of the venous outflow away from the anastomosis, arterial stenosis, intragraft stenosis, pseudoaneurysms, and no identifiable cause in a small percentage. There were 16 complications, 8 of which required additional therapy or potentially compromised the graft. These results suggest that pharmacomechanical thrombolysis and angioplasty provide rapid, consistent, and safe recanalization of thrombosed hemodialysis grafts and represent an additional therapeutic approach to graft management.

Angioplasty, Balloon↗

Effects of intrathrombic administration of prostaglandin E1 during pulse-spray thrombolysis with tissue-type plasminogen activator in experimental thrombosis.

The effects of intrathrombic and intravenous injection of prostaglandin E1 (PGE1) during pulse-spray thrombolysis were studied in a rabbit model. Thrombi were produced in the inferior vena cava of 46 rabbits by means of vessel wall injury and placement of steel coils. At 2 days, pulse-spray thrombolysis was performed by using a catheter with multiple side holes spanning the clot. A control group received injections of saline. In all other rabbits, 3 mg of tissue-type plasminogen activator (tPA) was injected into the thrombus over 1 hour, and 500 U of heparin was intravenously administered. PGE1 was administered either intravenously (50 micrograms) or directly into the thrombus (10, 25, or 50 micrograms) in four groups. After treatment, the rabbits were killed and the residual clot was weighed. The relationship between clot length and volume measured on angiograms and clot weight was assessed in 13 additional untreated rabbits. Linear regression analysis was used to estimate the initial clot weight on the basis of measured clot length in treated animals. The extent of clot lysis was significantly greater with injection of tPA and 10-, 25-, or 50-micrograms PGE1 directly into the thrombous than with administration of tPA alone.

Alprostadil↗

Occluded peripheral arteries and bypass grafts: lytic stagnation as an end point for pulse-spray pharmacomechanical thrombolysis.

Angiographic demonstration of luminal narrowing during pulse-spray pharmacomechanical thrombolysis (PSPMT) may reflect residual lysable clot, organized thrombus, platelet-rich clot, atherosclerosis, neointimal hyperplasia, or functional narrowing. The authors evaluated the efficacy and safety of lytic stagnation (initial rapid lysis followed by insubstantial further lysis with additional treatment) as an end point for PSPMT. Lytic stagnation was evaluated with serial angiography in 16 arterial and five bypass graft occlusions. Substantial lysis occurred after administration of mean doses of 512,000 units +/- 182,000 of urokinase or 5.3 mg +/- 2.0 of tissue-type plasminogen activator. Additional treatment with either of those agents produced minimal or no further change in the appearance of residual disease. Recanalization was successful in all patients after angioplasty. Distal emboli were noted in four cases, in three of which angioplasty of large intraluminal filling defects had been performed. The authors conclude that lytic stagnation is a reliable and safe end point for PSPMT in the absence of large intraluminal filling defects.

Adult↗

Diagnosis of arteriogenic impotence: efficacy of duplex sonography as a screening tool.

OBJECTIVE: The results of duplex sonography of the cavernosal artery were compared with the results of pharmacoarteriography in a series of impotent men in order to assess the validity of sonography as a screening tool for the diagnosis of arteriogenic impotence. SUBJECTS AND METHODS: Duplex sonography was performed in 30 impotent men after intracavernosal injection of papaverine and phentolamine. Maximal acceleration, peak systolic velocity, and resistive index were determined for the cavernosal artery. All patients had selective pharmacoarteriography and cavernosometry, which were used to diagnose arterial disease (bilateral hemodynamically significant stenoses or occlusions), suspected arteriolar dysfunction (inconspicuous helicine arterioles), or venoocclusive insufficiency (pharmacologic maintenance erectile flow greater than 25 ml/min). Seventeen patients had arterial insufficiency, four had arteriolar dysfunction, and nine had no significant arterial disease. RESULTS: Significant differences in Doppler measurements were found between patients without significant arterial disease and those with arterial insufficiency, including peak systolic velocity (50 +/- 25 cm/sec vs 33 +/- 17 cm/sec, p = .04), acceleration (524 +/- 261 cm/sec2 vs 199 +/- 111 cm/sec2, p < .001), and resistive index (88 +/- 12% vs 73 +/- 11%, p = .002). Differences were also noted between the group without significant arterial disease and the group with arteriolar dysfunction. When peak systolic velocity of less than 25 cm/sec or acceleration less than 400 cm/sec2 was used as an indication of inadequate arterial patency, the sensitivities were 35% and 100%, the specificities were 61% and 46%, and the negative predictive values were 42% and 100%, respectively, in the diagnosis of arterial insufficiency. CONCLUSION: Duplex sonography of the cavernosal arteries may be a useful screening tool in patients with suspected arteriogenic impotence only when acceleration is evaluated in addition to peak systolic velocity. The specificity of the method may be partially limited by the inability to distinguish between arterial and arteriolar disease.

Adolescent↗