A Monte Carlo based method to estimate radiation dose from multidetector CT (MDCT): cylindrical and anthropomorphic phantoms.

The purpose of this work was to extend the verification of Monte Carlo based methods for estimating radiation dose in computed tomography (CT) exams beyond a single CT scanner to a multidetector CT (MDCT) scanner, and from cylindrical CTDI phantom measurements to both cylindrical and physical anthropomorphic phantoms. Both cylindrical and physical anthropomorphic phantoms were scanned on an MDCT under the specified conditions. A pencil ionization chamber was used to record exposure for the cylindrical phantom, while MOSFET (metal oxide semiconductor field effect transistor) detectors were used to record exposure at the surface of the anthropomorphic phantom. Reference measurements were made in air at isocentre using the pencil ionization chamber under the specified conditions. Detailed Monte Carlo models were developed for the MDCT scanner to describe the x-ray source (spectra, bowtie filter, etc) and geometry factors (distance from focal spot to isocentre, source movement due to axial or helical scanning, etc). Models for the cylindrical (CTDI) phantoms were available from the previous work. For the anthropomorphic phantom, CT image data were used to create a detailed voxelized model of the phantom's geometry. Anthropomorphic phantom material compositions were provided by the manufacturer. A simulation of the physical scan was performed using the mathematical models of the scanner, phantom and specified scan parameters. Tallies were recorded at specific voxel locations corresponding to the MOSFET physical measurements. Simulations of air scans were performed to obtain normalization factors to convert results to absolute dose values. For the CTDI body (32 cm) phantom, measurements and simulation results agreed to within 3.5% across all conditions. For the anthropomorphic phantom, measured surface dose values from a contiguous axial scan showed significant variation and ranged from 8 mGy/100 mAs to 16 mGy/100 mAs. Results from helical scans of overlapping pitch (0.9375) and extended pitch (1.375) were also obtained. Comparisons between the MOSFET measurements and the absolute dose value derived from the Monte Carlo simulations demonstrate agreement in terms of absolute dose values as well as the spatially varying characteristics. This work demonstrates the ability to extend models from a single detector scanner using cylindrical phantoms to an MDCT scanner using both cylindrical and anthropomorphic phantoms. Future work will be extended to voxelized patient models of different sizes and to other MDCT scanners.

Body Burden↗

A Monte Carlo-based method to estimate radiation dose from spiral CT: from phantom testing to patient-specific models.

The purpose of this work is to develop and test a method to estimate the relative and absolute absorbed radiation dose from axial and spiral CT scans using a Monte Carlo approach. Initial testing was done in phantoms and preliminary results were obtained from a standard mathematical anthropomorphic model (MIRD V) and voxelized patient data. To accomplish this we have modified a general purpose Monte Carlo transport code (MCNP4B) to simulate the CT x-ray source and movement, and then to calculate absorbed radiation dose in desired objects. The movement of the source in either axial or spiral modes was modelled explicitly while the CT system components were modelled using published information about x-ray spectra as well as information provided by the manufacturer. Simulations were performed for single axial scans using the head and body computed tomography dose index (CTDI) polymethylmethacrylate phantoms at both central and peripheral positions for all available beam energies and slice thicknesses. For comparison, corresponding physical measurements of CTDI in phantom were made with an ion chamber. To obtain absolute dose values, simulations and measurements were performed in air at the scanner isocentre for each beam energy. To extend the verification, the CT scanner model was applied to the MIRD V model and compared with published results using similar technical factors. After verification of the model, the generalized source was simulated and applied to voxelized models of patient anatomy. The simulated and measured absolute dose data in phantom agreed to within 2% for the head phantom and within 4% for the body phantom at 120 and 140 kVp; this extends to 8% for the head and 9% for the body phantom across all available beam energies and positions. For the head phantom, the simulated and measured absolute dose data agree to within 2% across all slice thicknesses at 120 kVp. Our results in the MIRD phantom agree within 11% of all the different organ dose values published by the UK's ImPACT group for a scan using an equivalent scanner, kVp, collimation, pitch and mAs. The CT source model was shown to calculate both a relative and absolute radiation dose distribution throughout the entire volume in a patient-specific matrix geometry. Results of initial testing are promising and application to patient models was shown to be feasible.

Adult↗

A virtual source model for Monte Carlo modeling of arbitrary intensity distributions.

A photon virtual source model was developed for simulating arbitrary, external beam, intensity distributions using the Monte Carlo method. The source model consists of a photon fluence grid composed of a matrix of square elements, located 25-cm downstream from the linear accelerator target. Each particle originating from the fluence map is characterized by the seven phase space parameters, position (x, y, z), direction (u, v, w), and energy. The map was reconstructed from fluence and energy spectra acquired by modeling components of the linear accelerator treatment head using the Monte Carlo code MCNP4B. The effect of contaminant electrons is accounted for by the use of a sub-source derived from a phase-space simulation of a 25-MV linac treatment head using the code BEAM. The BEAM sub-source was incorporated into the MCNP4B phase-space model and is sampled using a field-size dependent sampling ratio. A Gaussian blurring kernel is convolved with the photon fluence map to account for the finite focal spot size and scattering effects from structures such as the flattening filter and MLC leaves. Depth dose and profile source calculations for 6-MV and 25-MV photon beams, for 5 x 5 cm2, 10 x 10 cm2, and 15 x 15 cm2 field sizes, are in good agreement with measurement and are well within acceptability criteria suggested by the AAPM Task Group Report No. 53. Irregular field calculations compared with film measurement and with a 3-D pencil beam algorithm show that the source model is capable of accurately simulating arbitrary MLC fields.

Biophysical Phenomena↗

CT-based dosimetry calculations for 125I prostate implants.

PURPOSE: To evaluate the Monte Carlo code MCNP4B for low-energy brachytherapy calculations, including the effects of interseed attenuation and patient specific heterogeneities, on the calculated dose distribution from transperineal implantation of 125I. METHODS AND MATERIALS: The Monte Carlo code MCNP4B was used to model and benchmark the absolute dose distribution from two 125I brachytherapy seeds (model 6711 and 6702). Based upon the physical source model, the total photon intensity and differential energy spectrum were evaluated as a function of angle from the transverse bisector of the source. These spectral and intensity data were reformatted to produce probability distributions for sampling from a virtual point source. The virtual source model and a modified version of MCNP4B is then used for simulating arbitrary brachytherapy source configurations within a homogeneous or heterogeneous patient specific computed tomography (CT)-based lattice geometry. RESULTS AND CONCLUSION: Comparison with TG-43 data and the Monte Carlo calculations is excellent with MCNP4B predicting the radial dose function for the 125I 6711 and 6702 sources within 6% for all data points tested. Attenuation effects from neighboring seeds were investigated for pre- and postimplant seed distributions and found to be negligible. Preliminary dosimetry analysis of postimplant seed distributions comparing homogeneous water versus heterogeneous CT simulation geometries indicates an average decrease of approximately 5.6% for the volume of tissue irradiated to a prescription isodose line of 144 Gy.

Brachytherapy↗

Monte Carlo treatment planning for stereotactic radiosurgery.

OBJECTIVES: In radiosurgery treatment planning there is general acceptance that the target volume can be assumed to be homogeneous and that corrections for variations in contour are unnecessary. Thus, dose algorithms employed in radiosurgery treatment planning are quite unsophisticated; in almost every case the algorithms are the simple product of tissue-maximum and off-axis ratios and an output factor. In small photon beams, however, the lack of side scatter equilibrium compromises these assumptions. METHODS: In this work we have employed Monte Carlo techniques in an attempt to obtain a more accurate representation of radiosurgical dose distributions. Specifically, the Monte Carlo system which we have devised traces the paths of primary and secondary radiation through a patient-specific anatomical representation defined by computed tomography data. In this manner the perturbation effects from external contour changes and internal tissue heterogeneities are accounted for completely. The ability to precisely mimic multi-beam multi-arc stereotactic delivery has been incorporated into our Monte Carlo treatment planning interface. RESULTS: Subsequent calculations show that substantial differences can exist when homogeneity is not assumed. Tissue heterogeneities produce a lateral broadening of the beam, resulting in a smaller volume contained within the higher isodose levels (80-90%) with a corresponding increase in the volume treated at the lower isodose levels (<50%). CONCLUSIONS: These results suggest that further investigation and refinement of radiosurgery dose algorithms is in order.

Humans↗

A CT-based Monte Carlo simulation tool for dosimetry planning and analysis.

The Los Alamos code MCNP4A (Monte Carlo N-Particle version 4A) is currently used to simulate a variety of problems ranging from nuclear reactor analysis to boron neutron capture therapy. A graphical user interface has been developed that automatically sets up the MCNP4A geometry and radiation source requirements for a three-dimensional Monte Carlo simulation using computed tomography data. The major drawback for this dosimetry system is the amount of time to obtain a statistically significant answer. A specialized patch file has been developed that optimizes photon particle transport and dose scoring within the standard MCNP4A lattice geometry. The transport modifications produce a performance increase (number of histories per minute) of approximately 4.7 based upon a 6 MV point source centered within a 30 x 30 x 30 cm3 lattice water phantom and 1 x 1 x 1 mm3 voxels. The dose scoring modifications produce a performance increase of approximately 470 based upon a tally section of greater than 1 x 10(4) lattice elements and a voxel size of 5 mm3. Homogeneous and heterogeneous benchmark calculations produce good agreement with measurements using a standard water phantom and a high- and low-density heterogeneity phantom. The dose distribution from a typical mediastinum treatment planning setup is presented for qualitative analysis and comparison versus a conventional treatment planning system.

Algorithms↗

A verification of the Monte Carlo code MCNP for thick target bremsstrahlung calculations.

The bremsstrahlung spectra from thick targets of Be, Al, and Pb are calculated using the Monte Carlo code MCNP (Monte Carlo N-particle). The current version of MCNP (v.4A) incorporates a coupled electron-photon transport scheme that allows the user to estimate the photon fluence produced from primary electron interactions. The simulation parameters are based on bremsstrahlung measurements of 15 MeV electrons incident on thick targets of Be, Al, and Pb at various angles between 0 degree and 90 degrees. The integrated yield and mean energy of each bremsstrahlung spectrum is calculated for the three targets at these angles. For angles less than 60 degrees the integrated yield calculated by MCNP4A is within 6% of measured values for the three targets. Furthermore, predicted mean energy is within 7% of the values derived from measurement for all angles tested. Also compared are the performances of two MCNP4A fluence tallies; a next-event estimator (detector tally) and a track length estimator (cell tally). Timing studies indicate the detector tally will perform the integrated yield calculations to a precision of 1% approximately 10 to 50 times faster than the conventional cell tally for an emission angle of 0 degree.

Aluminum↗