The mechanical reaction of the pars flaccida of the eardrum to rapid air pressure oscillations modeling different levels of atmospheric disturbances.

Atmospheric pressure fluctuations (APF) might induce mechanical effects in the pars flaccida (PF) of the eardrum. To clarify these effects, different kinds of pressure oscillations (PO), chosen within the range of naturally occurring APF, were applied to the middle ears (ME) of gerbils. The linear displacement of the PF during a PO in the ME was measured by laser interferometry. The compliance of the PF to PO was calculated as the ratio of the amplitude of a PF oscillation to the amplitude of a PO. The displacement of the PF traced the PO in the entire range of frequencies (from 10mHz to 200mHz) and amplitudes (from 10Pa to 110Pa) applied to the ME. Moreover, the PF is found to be displaced by pressure pulses of a few pascals only using a PO with a complex shape. The differences found in the compliance of the PF due to PO with low (less than 20Pa) and high (more than 90Pa) amplitude point out that the mechanism of pressure regulation in the ME through the mechanical reaction of the PF in gerbil ears is better adapted to ordinary levels of natural APF than to extraordinary levels. The implications of these findings for the physiology of the human ME with respect to adaptation to natural APF are discussed.

Animals↗

The effects of slight pressure oscillations in the far infrasound frequency range on the pars flaccida in gerbil and rabbit ears.

This study was designed to clarify whether the pars flaccida (PF) as a flexible part of the tympanic membrane is capable of reacting to pressure oscillations (PO) with amplitudes and frequencies typical for natural atmospheric pressure fluctuations in the far infrasound frequency range (APF). If so, the PF mechanical reactions to APF might be involved in the overall physiologic regulation processes, which make organisms susceptible to APF. The displacements of the PF in response to PO were measured in vitro in ears of gerbils and rabbits by means of laser Doppler vibrometry. The index of the PF reactivity (R(a)) was determined as the ratio of the amplitude of the PF oscillations (PFO) to the amplitude of the PO. All kinds of PO applied caused PFO. The amplitude of the PFO increased when the amplitude of the PO was increased. In gerbils, a decrease in R(a) with the increase in amplitude of the PO was observed. In the range of PO lowest amplitudes (4-20 Pa) R(a) proved to be 1.4 times higher than in the range of highest amplitudes (90-105 Pa). Considering that the natural APF are usually within the range of +/-20 Pa, this fact points to an important contribution of the PF to the pressure dynamics in the middle ear (ME) of gerbils. In rabbit ears, R(a) was lower and recovery from plastic deformation was slower than in gerbils. Our findings are in line with the suggestion that the PF might play an important role in respect of adaptation to natural APF.

Acoustic Stimulation↗

Thickness distribution of fresh eardrums of cat obtained with confocal microscopy.

The aim of this study was to measure the spatial thickness distribution of the cat tympanic membrane (TM), a very thin, virtually transparent and delicate biological membrane. Axial fluorescence images taken perpendicular through isolated TM were recorded for five different cats using confocal laser scanning microscopy. Thickness was measured on the cross-section of the membranes in the axial images. A correction for focal shift due to refractive-index mismatch was applied. Similar thickness distributions were obtained in all measured samples (n = 9). The pars tensa had a rather constant thickness in the central region between the annulus and manubrium. The thickness increased steeply toward the peripheral rim. Thickness was smallest in the inferior region, with values ranging between 5.5 and 9 microm in the central part and up to 50 microm near the annulus. More superiorly, thickness was slightly higher, up to 20 microm, between the annulus and manubrium. The anterior part was thicker than the posterior side. These findings are strongly different from a current value in the literature. Our data allow a more precise representation of the eardrum in mathematical models, which are a prerequisite for a better understanding of middle-ear mechanics. The optical sectioning technique of the confocal microscope did not result in any preparation artifacts and was therefore also used to quantify shrinkage due to preparation of histological sections of TMs.

Animals↗

A procedure to determine the correct thickness of an object with confocal microscopy in case of refractive index mismatch.

A difference in refractive index (n) between immersion medium and specimen results in increasing loss of intensity and resolution with increasing focal depth and in an incorrect axial scaling in images of a confocal microscope. Axial thickness measurements of an object on such images are therefore not exact. The present paper describes a simple procedure to determine the correct axial thickness of an object with confocal fluorescence microscopy. We study this procedure for a specimen that has a higher refractive index than the immersion medium and with a thickness up to 100 microm. The measuring method was experimentally tested by comparing the thickness of polymer layers measured on axial images of a confocal microscope in case of a water-polymer mismatch to reference values obtained from an independent technique, i.e. scanning electron microscopy. The case when the specimen has a lower refractive index than the immersion medium is also shown by way of illustration. Measured thickness data of a water layer and an oil layer with the same actual thickness were obtained using an oil-immersion objective lens with confocal microscopy. Good agreement between theory and experiment was found in both cases, consolidating our method.

Journal Article↗

Three-dimensional modelling of the middle-ear ossicular chain using a commercial high-resolution X-ray CT scanner.

The quantitative measurement of the three-dimensional (3-D) anatomy of the ear is of great importance in the making of teaching models and the design of mathematical models of parts of the ear, and also for the interpretation and presentation of experimental results. This article describes how we used virtual sections from a commercial high-resolution X-ray computed tomography (CT) scanner to make realistic 3-D anatomical models for various applications in our middle-ear research. The important problem of registration of the 3-D model within the experimental reference frame is discussed. The commercial X-ray CT apparatus is also compared with X-ray CT using synchrotron radiation, with magnetic resonance microscopy, with fluorescence optical sectioning, and with physical (histological) serial sections.

Animals↗

A simple method for checking the illumination profile in a laser scanning microscope and the dependence of resolution on this profile.

One of the conditions for a laser scanning microscope to reach its optimal performance is for it to operate at its full numerical aperture (NA). In most commonly used systems, the illumination intensity at the back focal plane of the objective lens is apodized. This paper presents a simple method using a photodiode for checking the actual illumination intensity profile. We show as an example the measured profiles of a laser beam when working with two high-NA immersion objectives in two different confocal systems, and also show that in theoretical studies of the point-spread function, the assumption of a flat compared with a truncated Gaussian beam profile gives rise to severe discrepancies. The measured profiles also serve as an indication of the necessity of a realignment of the optical system.