Clinical evaluation of morphology discrimination: an algorithm for rhythm discrimination in cardioverter defibrillators.

The aim of this study was to test the new morphology discrimination diagnostic algorithm for ICDs that differentiates supraventricular tachycardias (SVTs) from VTs by analysis of ventricular depolarization complexes morphology. Twenty-five patients implanted with a St. Jude Ventritex single chamber ICD were studied during electrophysiological evaluation at predischarge and were followed for 7 +/- 4 months. Sensitivity and specificity for VT detection and overall diagnostic accuracy of the morphology discrimination algorithm were calculated on 326 detected events. At electrophysiological evaluation, the algorithm was tested during 67 episodes of right atrial pacing, during 119 episodes of RV pacing (at basal interventricular septum and RV apex) and during 27 episodes of sustained AF: specificity was 98%, sensitivity was 66%, and diagnostic accuracy was 80%. All episodes of AF were correctly diagnosed as SVT. Exclusion of detections related to pacing at the basal interventricular septum, resulted in a specificity of 98%, a sensitivity of 85%, and a diagnostic accuracy of 93%. During follow-up, evaluation of the morphology discrimination algorithm on 113 spontaneous episodes (31 VTs, 31 AF, 7 SVTs, and 44 sinus tachycardias) exhibited a specificity of 89%, a sensitivity of 100%, and a diagnostic accuracy of 92%. In conclusion, the morphology discrimination algorithm exhibits a high specificity in discriminating VTs from SVTs, although with a corresponding reduction in sensitivity. The preliminary experience on spontaneous episodes is promising. To correct for the reduction in sensitivity, it is advisable to use this algorithm in parallel with other algorithms for rhythm discrimination (sudden onset, stability) coupled with extended high rate.

Adult↗

Hemodynamic responses to rapid pacing: a model for tachycardia differentiation.

The hemodynamic responses to rapid atrial and ventricular pacing were examined in 10 closed-chest anesthetized dogs in an attempt to distinguish hemodynamically stable from unstable tachycardias. Pressure monitoring catheters were placed in the femoral artery, right atrium, and right ventricle to measure mean arterial pressure, mean right atrial pressure, and mean right ventricular pressure at baseline heart rate and after rapid high right atrial and right ventricular apex pacing. Pressures recorded during rapid pacing (average of the pressures at 30 and 60 seconds of pacing) at pacing rates of 180, 250, and 280/minute were compared to those recorded initially at baseline heart rates. Rapid right ventricular apex pacing resulted in significant increases in mean right atrial pressure (from 6 +/- 1 mmHg (mean +/- standard error) to 12 +/- 1 mmHg, a 100% increase, P less than 0.001) and mean right ventricular pressure (from 11 +/- 1 mmHg to 16 +/- 1 mmHg, a 45% increase, p less than 0.02) with marked hemodynamic compromise (mean arterial pressure decreased from 85 +/- 6 mmHg to 50 +/- 6 mmHg, a 41% decrease, P less than 0.01). These parameters remained stable (no statistically significant difference from baseline) during high right atrial pacing. In half of the dogs high right atrial pacing at rates greater than or equal to 250 resulted in atrioventricular Wenckebach. Thus, it is concluded that mean right atrial pressure and mean right ventricular pressure may be useful in distinguishing hemodynamically significant tachycardias, and in the future design of antitachycardia devices.

Animals↗