Prolonged mechanical support of the left ventricle.

An interdisciplinary group has developed a left ventricular assist pump system composed of a modified sac type pump, a pneumatic power unit, and a synchronizer. The pump fills from the left ventricle and discharges into the aorta. The system was employed for left ventricular assistance in a series of 12 normal calves, with an average pumping period of 70 +/- 8 days. The system was then evaluated in a series of calves in whom profound left ventricular failure had been produced. These studies indicate that the assist pump is effective in supporting the circulation and completely unloading the left ventricle. The assist system has now been employed in four patients who could not be weaned from cardiopulmonary bypass following cardiac valve replacement. The assist pump supported the circulation in three instances. In one patient, the assist pump was employed for 8 days until left ventricular function had improved sufficiently to permit pump removal; the patient was subsequently discharged from the hospital.

Aged↗

Effects of an abdominal left ventricular assist device on myocardial oxygen supply/demand ratios in normally perfused and ischemic bovine myocardium.

The effects of an abdominal left ventricular assist device (ALVAD) on subendocardial oxygen supply/demand ratios as reflected by diastolic pressure-time index/tension-time index (DPTI/TTI) were investigated in calves. Control DPTI/TTI ratios were 1.09 plus or minus 0.12 (mean plus or minus SD). With ALVAD actuation the ratios increased to 5.73 plus or minus 3.2. Following circumflex coronary artery occlusion, control ratios decreased to 0.04 plus or minus 0.05 in the ischemic area and 0.97 plus or minus 0.20 in the nonischemic areas. With ALVAD actuation in the presence of circumflex occlusion, the depressed ratios were increased to 1.37 plus or minus 0.39 in the ischemic zone and 9.71 plus or minus 2.5 in the nonoccluded segments. Subendocardial oxygen supply/demand ratios were significantly improved by ALVAD assistance following induced subendocardial ischemia.

Animals↗

An abdominal left ventricular assist device: preclinical studies.

An abdominally positioned left ventricular assist device (ALVAD) has been evaluated in our most recent series of 25 calves weighing 99 plus or minus 12 kg. The ALVAD is a pneumatically actuated bladder pump, positioned subdiaphragmatically and connected between the left ventricular apex and the infrarenal abdominal aorta. The mean survival time in the calves was 41 days and the longest 65 days. The major effects of the pump are reduction of all indices of left ventricular work and increases in systemic perfusion. In the awake, unanesthetized calf, left ventricular pressure, dP/dt, and stroke work were decreased while peak aortic pressure, stroke volume, and cardiac output increased. These effects were corroborated at cardiac catheterization two to four weeks postoperatively; left ventriculograms also showed increases in ejection fraction. These data demonstrate the ALVAD's effectiveness in assuming left ventricular function and support over extended periods. The device has been developed for short-term postoperative clinical use in patients with reversible left ventricular failure.

Abdomen↗