Laser in situ keratomileusis for myopia up to -11 diopters with up to -5 diopters of astigmatism with the summit autonomous LADARVision excimer laser system.

OBJECTIVE: To assess the safety and effectiveness of the Summit Autonomous LADARVision active tracking narrow beam excimer laser system for laser in situ keratomileusis (LASIK) correction of myopia and astigmatism. DESIGN: A multicenter, prospective noncomparative case series. PARTICIPANTS: This cohort consisted of 177 eyes corrected for spherical myopia up to -11 diopters (D) and 170 eyes corrected for myopia up to -11 D spherical equivalent with astigmatism up to -5 D. INTERVENTION: Treatments were performed at four sites in the United States using a 6-mm optic zone for spherical myopes and a 5.5-mm optic zone with a 1-mm blend for astigmats. MAIN OUTCOME MEASURES: Visual acuity, subjective refraction, vector analysis, subject satisfaction, intraocular pressure, complications, and adverse reactions. RESULTS: Six-month follow-up was available on 157 spherical eyes and 113 astigmatic eyes. For spherical myopes, uncorrected visual acuity (UCVA) was 20/20 or better in 60.5%, 20/25 or better in 80.3%, and 20/40 or better in 93.9%. The mean spherical equivalent was -0.29 +/- 0.45 D with 75.2% +/- 0.50 D and 94.9% +/- 1.00 D of intended. A loss of two lines of best spectacle-corrected visual acuity (BSCVA) occurred in 0.6%, and no eyes lost greater than two lines of BSCVA. For astigmatic myopes, UCVA was 20/20 or better in 52.0%, 20/25 or better in 74.5%, and 20/40 or better in 94.1%. The mean spherical equivalent was -0.23 +/- 0.49 D with 75.2% +/- 0.50 D and 95.6% +/- 1.00 D of intended. A loss of two lines of BSCVA occurred in 0.9%, and no eyes lost greater than two lines of BSCVA. Vector analysis showed that 99% of the intended cylinder was corrected on average with a mean angle of error of 4.2 degrees. Refractive stability was achieved between 1 and 3 months in 97.5% of spherical eyes and 99.4% of astigmatic eyes and confirmed between 3 and 6 months in 100% of both spherical and astigmatic eyes. CONCLUSIONS: Eyes treated for myopia up to -11 D of spherical equivalent with or without astigmatism up to -5 D show early refractive stability, good UCVA outcomes, no significant loss of BSCVA, accurate correction of astigmatism, and slight undercorrection without a change from the photorefractive keratectomy algorithm and with a single treatment.

Adult↗

Photorefractive keratectomy for low-to-moderate myopia and astigmatism with a small-beam, tracker-directed excimer laser.

OBJECTIVE: To assess the safety and effectiveness of the Autonomous Technologies Corporation LADARVision excimer laser system for photorefractive keratectomy correction of myopia and astigmatism. DESIGN: A multicenter, prospective, noncomparative case series. PARTICIPANTS: The cohort consisted of 467 eyes corrected for spherical myopia and 211 eyes corrected for myopia with astigmatism. INTERVENTION: Treatments were performed at six sites in the United States using a 6-mm ablation zone for spherical myopes and a 5.5-mm zone with a 1.0-mm blend for astigmats. MAIN OUTCOME MEASURES: Visual acuity, subjective refraction, corneal haze, intraocular pressure, complications, adverse reactions, patient satisfaction, and corneal endothelial changes. RESULTS: Twelve-month follow-up was available on 414 spherical eyes and 175 astigmatic eyes. The results for spherical eyes with correction between -1 and -5.99 diopters (D) were: uncorrected visual acuity (UCVA) of 20/40 or better achieved by 98.1%, 20/20 or better by 72%, 1.8% lost 2 lines and 0.3% lost greater than 2 lines of best spectacle-corrected visual acuity (BSCVA); 76.4% were within 0.50 D of the target correction and 94.4% were within 1.00 D. The results for myopia with astigmatism with spherical equivalent correction between -1 and -5.99 D were: UCVA of 20/40 or better in 97.4%, 20/20 or better in 61.7%, 2.5% lost 2 lines and no eyes lost greater than 2 lines BSCVA; 73.9% were within 0.50 D of the target correction and 95% were within 1.00 D. For spherical myopes combined with myopic astigmats corrected for 6 to 10 D, results were: UCVA of 20/40 or better in 93.4%, 20/20 or better in 61.2%, 2.3% lost 2 lines and no eyes lost greater than 2 lines of BSCVA; 67.2% were within 0.50 D of the desired correction and 87.8% were within 1.00 D. Refractive stability was achieved between 3 and 6 months for the spherical and astigmatic groups. No eyes had corneal haze graded as moderate or greater, and there was no significant decrease in endothelial cell density. CONCLUSIONS: Patients treated for 1 to 10 D of spherical equivalent myopia, with or without astigmatism, showed early refractive stability, excellent UCVA, no significant loss of BSCVA, no loss of endothelial cell density, and very low levels of corneal haze to 12 months after surgery.

Adult↗

Bilateral photorefractive keratectomy with intentional unilateral undercorrection in an aircraft pilot.

An aircraft pilot had bilateral photorefractive keratectomy (PRK) with intentional undercorrection in the nondominant eye for best uncorrected far and near visual acuity (monovision). After PRK, the patient was able to pilot an aircraft with no deleterious effects directly related to surgery. Evaluation of similar cases and further study will allow consensus on whether PRK is appropriate in these patients.

Aerospace Medicine↗

Results of excimer laser photorefractive keratectomy for the correction of myopia.

PURPOSE: This report summarizes the authors' 3-year experience with excimer laser photorefractive keratectomy on 240 eyes of 161 patients. METHODS: With constant laser emission parameters, nitrogen flow across the cornea was used on 79 eyes, whereas 161 eyes had no nitrogen flow. Of the 240 eyes, 74 were operated on without suction ring fixation. Postoperative pain management included patching and oral analgesics in 77 eyes and the use of topical diclofenac or ketorolac and a therapeutic soft contact lens in 163 eyes. Follow-up ranged from 1 month (206 eyes) to 36 months (10 eyes). RESULTS: At 3 months, 88% (144 eyes) had uncorrected visual acuity of 20/40 or better; 86% (151 eyes) had corrected visual acuity to within +/- 1 diopter of intended correction, and 10% (17 eyes) lost two or more lines of best-corrected visual acuity. At 12 months, 89% (122 eyes) achieved uncorrected visual acuity of 20/40 or better, 79% (115 eyes) had corrected visual acuity to within +/- 1 diopter of intended correction, and 4% (6 eyes) lost two or more lines of best-corrected visual acuity. At 24 months, 92% (44 of 48 eyes) had uncorrected visual acuity of 20/40 or better, 86% (44 of 51 eyes) had corrected visual acuity to within +/- 1 diopter of intended correction, and 5% (2 eyes) lost two or more lines of best-corrected visual acuity. At 36 months, 90% (9 eyes) achieved an uncorrected visual acuity of 20/40 or better, 90% (9 eyes) had corrected visual acuity to within +/- 1 diopter of intended correction, and no eyes lost two or more lines of best-corrected visual acuity. CONCLUSIONS: The results obtained with one procedure are within accepted standards of accuracy for refractive surgery, and there is the potential for refinement of the final optical correction. Complication rates are low and are not vision threatening. They included increased intraocular pressure, epithelial "map dot" changes, and recurrent corneal erosion syndrome, "central islands," and others. Photorefractive keratectomy appears to be a safe procedure over the short and medium term.

Adult↗

A two-year experience with excimer laser photorefractive keratectomy for myopia.

PURPOSE: This report summarizes the authors' 2-year experience with excimer laser photorefractive keratectomy (PRK) on 160 eyes of 128 patients. METHODS: All eyes were treated with an excimer laser: fluence, 160 mJ/cm2; frequency, 5 Hz; ablation zone diameter, 5.0 to 5.5 mm; and depth per pulse, 0.21 to 0.27 microns. A suction fixation ring was used in all eyes either with nitrogen flow (79 eyes) or without nitrogen flow (81 eyes) across the cornea. Follow-up ranged from 1 month (152 eyes) to 24 months (12 eyes). RESULTS: At 3 months, 82% (139) of eyes achieved an uncorrected visual acuity of 20/40 or better; 83% were corrected to within +/- 1 diopter (D) of intended correction and 30% lost one line of best-corrected visual acuity. At 6 months, 88% (124) of eyes achieved an uncorrected visual acuity of 20/40 or better; 84% were corrected to within +/- 1 D of intended correction and 15% lost one line of best-corrected visual acuity. At 12 months, 91% (71) of eyes achieved an uncorrected visual acuity of 20/40 or better; 84% were corrected to within +/- 1 D of intended correction and 17% lost one line of best-corrected visual acuity. At 24 months, 100% (12) of eyes achieved an uncorrected visual acuity of 20/40 or better; 91.6% were within +/- 1 D of intended correction and 0% lost one line of best-corrected visual acuity. CONCLUSIONS: In eyes with a follow-up of 6 to 24 months, 77% to 100% achieved an uncorrected visual acuity of 20/40 or better and 84% to 92% were corrected to within +/- 1 D of the intended correction. The authors conclude that excimer laser PRK appears to be a safe procedure capable of correcting the eyes of patients with low to moderate myopia with approximately the same degree of accuracy as radial keratotomy.

Adult↗

Effect of thermokeratoplasty on corneal curvature.

A cadaver eye model was used to evaluate and quantify the use of thermokeratoplasty for steepening the central cornea to correct hyperopia. Four groups of eye-bank eyes were treated with four separate surgical plans. Each plan involved the placement of controlled thermal burns (in the depths of the corneal stroma, using a cautery probe) applied in a radial pattern up to a premarked optical zone. The plans differed in the sequence of surgical steps. All plans progressively added radials and applications (to decrease optical zone) in various sequences. Corneal curvature was measured at baseline and at each surgical step. As more surgery was done within each plan, the corneas became progressively steeper. Total mean changes in corneal curvature ranged from 16.26 diopters to 19.76 diopters, depending on the plan. At each optical zone, as the number of radials increased, the effect increased. With progressively smaller optical zone size, the effect also increased.

Cornea↗

Lens implant exchanges for incorrect power: results of an informal survey.

Despite the introduction of ultrasonic axial length measurements and a variety of intraocular lens implant prediction formulas, postoperative predicted errors greater than 2 diopters occur in approximately 5% to 10% of lens implantations, and occasional errors of 5 diopters to 7 diopters or greater are still encountered. An informal survey revealed successful lens implant exchanges for initial postoperative refractive errors of +4.37 to -14.00 diopters in eight eyes.

Eye Diseases↗

A simple, convenient tonometer tip disinfection technique.

A simple tonometer tip disinfection system is described. 10% sodium hypochlorite (household bleach) in a contact lens vial is taped to the base of the Goldmann applanation tonometer. The tonometer tip is then soaked for ten minutes in this vial.

Disinfection↗

Four-incision radial keratotomy for low to moderate myopia.

The first 112 consecutive eyes (75 patients) to undergo four-incision radial keratotomy (RK) performed by four surgeons were evaluated retrospectively. The preoperative myopia (spherical equivalent) ranged from -1.12 to -7.00 D (95% between -1.12 and -4.25 D). The preoperative uncorrected visual acuity was 20/100 or worse in 95% of the eyes. A six-month follow-up was achieved in 95% of the eyes and 45% were followed over one year. Following four incision RK, 79% of the eyes achieved 20/40 or better vision and 82% were corrected to within 1 D of emmetropia. Following repeat RK in 15 eyes (13%), 82% had uncorrected visual acuity of 20/40 or better, and 90% were corrected to within 1 D of emmetropia. Only 3.5% of the eyes were overcorrected by more than 1 D and only one eye had induced astigmatism greater than 1 D. For eyes with preoperative myopia up to -4.25 D over 90% achieved uncorrected visual acuity of 20/40 or better and were within 1 D of emmetropia following primary four incision RK and a second four incisions in 13 eyes (12%). Only 3.5% of the eyes in this group were overcorrected by more than 1 D. There were no serious complications.

Adult↗

A study of optical zone size and incision redeepening in experimental radial keratotomy.

The effects of optical clear zone size and incision redeepening following four- and eight-incision radial keratotomy were studied in a series of human cadaver eyes. Keratometry was measured with both the Terry keratometer and corneascope photographs. After eight incisions, induced corneal flattening for each clear zone (Terry keratometry readings) was 3.0 mm, 9.06 diopters; 4.0 mm, 6.44 D; 5.0 mm, 5.23 D; and 6.0 mm, 2.29 D. Differences were statistically significant, except for the 4.0-mm and 5.0-mm zones. Induced corneal flattening following eight incisions (corneoscopy) was 3.0 mm, 9.83 D; 4.0 mm, 8.87 D; 5.0 mm, 6.04 D; and 6.0 mm, 2.59 D. Differences were statistically significant, except for the 3.0-mm and 4.0-mm zones. Peripheral redeepening of the incisions did not significantly increase the amount of corneal flattening for any optical zone, as measured by the Terry keratometer. However, the 3.0-mm optical zone flattened an additional 1.23 D after the redeepening incisions, as measured by corneoscopy. The redeepening incisions were complicated by perforations in 38% of the eyes. Titrating the effect of radial keratotomy by varying the size of the optical zone appears to be valid, but the value of peripheral redeepening in the acute laboratory situation is not supported by these data.

Cornea↗

Multiple complications following radial keratotomy in an elderly patient: a case report.

A 68-year-old female underwent a 16-incision radial keratotomy in 1980. Her post-op course was complicated by marked overcorrection (+11.00), irregular astigmatism, and endothelial cell loss of almost 50%. Radial keratotomy in the elderly should be approached with caution because of the apparent increased effect of the surgery that occurs with increasing age.

Aged↗

Powderfree surgical gloves.

The first commercially available powderless glove was compared to other popular ophthalmic gloves. They were compared with scanning electron microscopy (SEM), the ease of donning, and tactile sensitivity. SEM revealed the new gloves to, in fact, be entirely powderfree. Customary washing procedures of the presently available commercial gloves revealed the inability to remove powder from the surfaces.

Gloves, Surgical↗

Analysis of incision depth following experimental radial keratotomy.

Eight-incision radial keratotomy was performed on a series of cadaver eyes using ultrasonic pachymetry and both metal and diamond blades. There were no statistically significant differences in mean corneal flattening (approximately 9.5 diopters) obtained with either the diamond or metal blades. Short diamond knife incisions produced less flattening that was statistically significant (5.8 diopters). Histologic analysis of incision depth revealed similar results with both the diamond (84%) and metal (86%) blades.

Cadaver↗

Evaluation and comparison of sources of variability in the measurement of corneal thickness with ultrasonic and optical pachymeters.

Two studies were carried out to determine and compare the effects of several sources of variation on the measurement of corneal thickness using the standard optical pachymeter and three ultrasonic pachymeters. Sources of variation included: intra- and inter-session variation, inter-observer variation, left/right eye variation, and variations due to alternate settings of ultrasonic sound frequencies. It was found that the optical pachymeter had a) two to three times as much intra-session variation as that of the ultrasound pachymeters, b) significant inter-observer variation (P = 0.015), and c) significant differences between left and right eye thickness determinations (P less than 0.005). On the other hand, ultrasonic pachymeters demonstrated a) high reproducibility, b) no inter-observer variation, and c) no left/right eye variation. These results have implications for the use of pachymetry in measuring corneal thickness for radial keratotomy and other refractive surgery.

Cornea↗