Testing a 3-D radiation therapy planning program.

This report describes a systematic effort to test all functions of a large 3-D radiation therapy planning program, including graphics and user interaction. Previous studies in quality assurance for radiation therapy programs do not adequately address the problem of programming errors. They compare dose estimates calculated by planning programs to actual doses measured in phantoms, so they cannot distinguish programming errors from measurement errors or physical unsoundness of the beam model. Moreover, they fail to exercise graphics and user interaction functions. This report describes a different methodology: test cases are derived from the program specification, results are calculated by an independent technique, and compared to program output. Derivation of test cases is described in detail. Effectiveness of testing is assessed by reporting the number of errors revealed by testing and comparing to the number of errors discovered during routine use in five successive program versions. The size of the test set is related to the total program size, and the effort devoted to deriving and performing tests is compared to the total program development effort. We conclude that systematic testing can reveal errors that are not found by informal testing, routine program use, or comparison with measurements. However, additional errors remain that are only discovered during use. This study suggests that a typical large planning system may include more than 100 errors when it is released for clinical use. Methods for increasing testing effectiveness are recommended.

Radiotherapy, Computer-Assisted

3-D radiation therapy treatment planning: overview and assessment.

A 3-D treatment planning system is one that can represent all radiation therapy treatment machine motions, and which can calculate the dose at any point in the patient treatment volume. As a corollary to these two requirements, a 3-D planning system must also be able to display 3-D plan geometry and doses in some useful way. This article reviews three visible aspects of 3-D planning systems: graphic displays, dose computation methods, and ease of use. It also discusses a less visible, but no less important, aspect: the underlying software engineering. Although 3-D planning systems first appeared in research institutions more than a decade ago, and potential benefits have been demonstrated, they are used only rarely in routine clinical practice. This review concludes that adequate displays and computation techniques are now available, but improved packaging, engineering, and ease of use are required before 3-D planning will be practiced widely.

Computer Graphics