PubMed Health⌕ Search

Biomedical subjects

J Jespersen

Publications and source records attributed to J Jespersen.

At least 19 recordsLinked to original sources

Estrogen receptor 1 haplotype does not regulate oral contraceptive-induced changes in haemostasis and inflammation risk factors for venous and arterial thrombosis.

BACKGROUND: Administration of oral contraceptives (OCs) has profound effects on the plasma levels of haemostasis and inflammation variables, resulting in an increased thrombosis risk. Individuals show large differences in the response of these variables to OCs. Polymorphism in the estrogen receptor-1 (ER1) gene may explain part of this inter-individual response. METHODS: We investigated the relationship between variants (c.454-397T>C and c.454-351A>G polymorphisms and the combined haplotype) in the ER1 gene in relation to changes in haemostasis and inflammation variables that are known risk factors for thrombosis in 507 healthy, nonsmoking, nulliparous women receiving six cycles of monophasic OCs with 20, 30 or 50 microg/day estrogen. RESULTS: A significant relationship was observed between the ER1 haplotype and changes in tissue-type plasminogen activator activity (P = 0.006), but no clear interaction pattern between the genotypes or between the estrogen doses was seen. No relationships were observed for the other variables, neither in the haplotype nor in the single polymorphism analysis. CONCLUSION: The ER1 haplotype does not have a strong effect on the estrogen-induced changes in haemostasis and inflammation risk markers for arterial and venous thrombosis.

Adult↗

The possible role of myostatin in skeletal muscle atrophy and cachexia.

The presence of sufficient skeletal muscle is of paramount importance for body function. Cachexia can be defined as a wasting syndrome describing the progressive loss of both adipose and skeletal muscle tissue in concert with severe injury, chronic or end-stage malignant and infectious diseases. Generally, cachexia predisposes to poor prognosis, co-morbidities and death. One signaling pathway possibly involved in muscle atrophy and cachexia is the myostatin cascade. This transforming growth factor-beta superfamily member myostatin is a strong candidate for regulating muscle mass, and is shown to inhibit muscle growth in different in vivo mammalian models. Overall, the modulation of the myostatin pathway seems interesting from the perspective of both pathology and sports medicine. Hence, myostatin signaling components and post-translational modulators are possible targets of pharmacological and other treatments against muscle loss, thus potentially contributing to the understanding and mitigation of muscle atrophies associated with inactivity, senescence and disease.

Animals↗

Genetic influence on thrombotic risk markers in the elderly--a Danish twin study.

OBJECTIVE: Several hemostatic variables are identified as cardiovascular risk markers. In young and middle-aged individuals, plasma concentrations of these variables are partly determined by genetic factors. The genetic contribution to cardiovascular disease (CVD) decreases with increasing age, and it is therefore important to determine the heritability of hemostasis also in the elderly. METHODS: The heritability of plasma levels of factor VII, fibrinogen, tissue factor, tissue factor pathway inhibitor, von Willebrand factor, thrombin activatable fibrinolysis inhibitor (TAFI), and D-dimer was determined in 130 monozygotic and 155 dizygotic same-sex twin pairs, aged 73-94 years, who participated in the Longitudinal Study of Aging of Danish Twins. Furthermore, we determined the influence of promoter polymorphisms in corresponding genes on the plasma level variation. RESULTS: Genetic factors accounted for 33% (D-dimer) to 71% (TAFI) of the variation in plasma levels. Polymorphisms were associated with concentrations of FVII and TAFI in sib-pair based analyses, but in linkage analyses the polymorphisms did not explain a significant part of the genetic variation for any of the variables. CONCLUSIONS: Concentrations of hemostatic variables have a substantial genetic variation in the elderly, but in this study the promoter polymorphisms only explained a minimal part of this variation.

Aged↗

Lack of hepatic metabolism of C-telopeptides of type I collagen.

BACKGROUND: Bone biochemical markers have been used in dynamic studies of bone metabolism, and, for accurate interpretation of measured marker levels, it is essential to have information of extra-skeletal metabolism. Therefore, the objective of the present study was to investigate if the circulating C-telopeptides of type I collagen (CTX) was subject to hepatic extraction. METHODS: Splanchnic plasma flow, total plasma volume and the plasma concentration of CTX was determined in an artery and the liver vein of eight healthy female volunteers. For comparison, the concentration of N-terminal propeptide of type I collagen, PINP, was measured. RESULTS: No change in plasma level of CTX could be detected over the liver. In contrast, PINP decreased from an average of 52.9 ng/ml in the artery to 42.4 ng/ml in the vein, corresponding to a 19.8% reduction. CONCLUSIONS: The C-telopeptides of type I collagen (CTX) are not subject to hepatic metabolism.

Adult↗

European Concerted Action on Anticoagulation. A multicentre calibration study of WHO international reference preparations for thromboplastin, rabbit (RBT/90) and human (rTF/95).

A 10 centre calibration was performed after six years to determine the international sensitivity index (ISI) of rTF/95 relative to RBT/90, and to assess any international normalised ratio (INR) bias compared with the original multicentre calibration. After exclusion of one outlying centre, the follow up calibration gave a mean ISI for rTF/95 of 0.99, which although a small difference, is significantly greater than the mean ISI of 0.94 obtained previously. The change in ISI for international reference preparation (IRP) rTF/95 relative to RBT/90 would lead to a slight bias in INR for human compared with rabbit thromboplastins. At a theoretical INR of 3.0, the INR bias is 6.0%, and this is below the accepted 10% level of clinical relevance. Ongoing stability monitoring of World Health Organisation thromboplastin IRP is advised.

Animals↗

Report on the Dutch consensus development meeting for implementation and further development of population screening for colorectal cancer based on FOBT.

A consensus development meeting was held to evaluate whether or not in the Netherlands all requirements were fulfilled for implementation of population screening with FOBT for colorectal cancer, or whether consensus was present that fulfilment by additional research or organisational actions could be obtained within 2-3 years. There was consensus that all classical Wilson and Jungner (1968) criteria, and six additional ones added more recently, had already been fulfilled or could be fulfilled within 2-3 years. Consequently, it was concluded that a national population screening for colorectal cancer should be implemented and carried out in the Netherlands in line with current national and European cancer screening programmes. A list of organisational actions to be taken was established. Research that is needed before the actual national launch of the screening within 2-3 years has been defined. Priorities have to be set for research and organisational actions for the coming 2-3 years for the implementation of population screening. In addition, research suggestions have been defined for the next 10-15 years for evaluation and/or improvement of implemented FOBT screening, and for future screening methodology. It was considered essential that infrastructure for future research would be embedded in the screening programme. A project group to arrange this should be formed.

Adenoma↗

Guidelines on preparation, certification, and use of certified plasmas for ISI calibration and INR determination.

Reliable international normalized ratio (INR) determination depends on accurate values for international sensitivity index (ISI) and mean normal prothrombin time (MNPT). Local ISI calibration can be performed to obtain reliable INR. Alternatively, the laboratory may determine INR directly from a line relating local log(prothrombin time [PT]) to log(INR). This can be done by means of lyophilized or frozen plasmas to which certified values of PT or INR have been assigned. Currently there is one procedure for local calibration with certified plasmas which is a modification of the WHO method of ISI determination. In the other procedure, named 'direct' INR determination, certified plasmas are used to calculate a line relating log(PT) to log(INR). The number of certified plasmas for each procedure depends on the method of preparation and type of plasma. Lyophilization of plasma may induce variable effects on the INR, the magnitude of which depends on the type of thromboplastin used. Consequently, the manufacturer or supplier of certified plasmas must assign the values for different (reference) thromboplastins and validate the procedure for reliable ISI calibration or 'direct' INR determination. Certification of plasmas should be performed by at least three laboratories. Multiple values should be assigned if the differences between thromboplastin systems are greater than 10%. Testing of certified plasmas for ISI calibration may be performed in quadruplicate in the same working session. It is recommended to repeat the measurements on three sessions or days to control day-to-day variation. Testing of certified plasmas for 'direct' INR determination should be performed in at least three sessions or days. Correlation lines for ISI calibration and for 'direct' INR determination should be calculated by means of orthogonal regression. Quality assessment of the INR with certified plasmas should be performed regularly and should be repeated whenever there is a change in reagent batch or in instrument. Discrepant results obtained by users of certified plasmas should be reported to manufacturers or suppliers.

Calibration↗

European Concerted Action on Anticoagulation (ECAA): an assessment of a method for ISI calibration of two whole blood point-of-care PT monitor systems based on lyophilized plasmas using whole blood equivalent PT.

Previously, the attempt to simplify the International Sensitivity Index (ISI) calibration of the CoaguChek Mini whole blood point-of-care test prothrombin time (PT) monitor system was successful using lyophilized plasmas from coumarin-treated patients but not with lyophilized artificially depleted plasmas. With the TAS PT-NC monitor system, both types of plasma failed to provide reliable calibrations. The present study assesses a procedure for the ISI calibration of a TAS PT-NC and CoaguChek Mini whole blood point-of-care test PT monitor systems using lyophilized plasmas. Using lyophilized artificially depleted and coumarin plasma calibrations, we have evaluated a correction for the monitor displayed PT. This was based on a 'line of equivalence' derived from the relationship between whole blood and fresh plasma PT with both types of monitor system. With the TAS PT-NC, the use of this 'line of equivalence' resulted in reliable ISI with both lyophilized coumarin and artificially depleted plasmas. There was no significant difference between mean monitor and mean reference International Normalized Ratio (INR) with the artificially depleted plasmas. With the lyophilized coumarin plasma calibrations there was only a small INR difference. Correction with the 'line of equivalence' therefore facilitates calibration of the TAS PT-NC with lyophilized plasmas. With the CoaguChek Mini, the correction based on the 'line of equivalence' did not improve results but was not required with this system.

Blood Preservation↗

Inflammation, thrombosis and atherosclerosis: results of the Glostrup study.

Inflammation and thrombosis are important mechanisms in cardiovascular disease, as illustrated by the consistent association between inflammatory and hemostatic variables and the risk of cardiovascular events in epidemiological studies. However, the relationship between plasma concentrations of inflammatory and hemostatic markers and the severity of atherosclerosis is not yet well studied. We have evaluated 325 men and 370 women of 60 years, participating in the Danish Glostrup study. We diagnosed atherosclerosis by ultrasonographic measurement of intima-media thickness (IMT) of the right carotid artery and the assessment of plaque occurrence. Plasma samples were analyzed for the concentration of C-reactive protein (CRP), fibrinogen, d-dimer, plasminogen activator inhibitor type-1 (PAI-1) antigen and activity, tissue-type plasminogen activator (t-PA) antigen and activity, factor VII (FVII) antigen, FVII coagulant activity (FVII:C) and activated FVII (FVIIa). DNA variations were determined for fibrinogen, PAI-1, t-PA, FVII, factor XIII and methylene tetrahydrofolate reductase (MTHFR). Subjects with high IMT (upper 10% of distribution, n = 63) had higher CRP levels [2.2 mg L-1 (SE 0.3)] than subjects with IMT in the lowest tertile (n = 217) [1.7 mg L-1 (SE 0.1), P = 0.04], whereas there was no association between the hemostatic variables and IMT. There was an association between fibrinogen and d-dimer concentrations and number of plaques (P < 0.01), whereas there were no associations between CRP and the other hemostatic variables and the number of plaques. Genetic variation in the t-PA and MTHFR gene was associated with IMT. In conclusion, in the Glostrup population study, thrombosis and inflammation are associated with the severity of atherosclerosis, as reflected by IMT and plaque occurrence.

Acute-Phase Proteins↗

Effect of long-term hormone replacement therapy on tissue factor pathway inhibitor and thrombin activatable fibrinolysis inhibitor in healthy postmenopausal women: a randomized controlled study.

It was recently reported from the Women's Health Initiative that healthy women using combined hormone replacement therapy (HRT) for 5 years have an increased cardiovascular risk. We hypothesize that the increased risk is confined to subgroups of atherosclerotic women. Such women may have higher arterial tissue factor expression and higher thrombin formation, and changes in tissue factor pathway coagulation inhibitor (TFPI) and thrombin activatable fibrinolysis inhibitor (TAFI) may be deleterious. Healthy postmenopausal women (n = 719) were randomized to hormone therapy [n = 357; opposed (n = 290) and unopposed (n = 67)] or no treatment (n = 362). Plasma TFPI and TAFI and the TFPI -287T/C and TAFI -438G/A polymorphisms were measured 5-6 years after randomization. Concentrations of TFPI were significantly lower in the hormone group than in the control group (P < 0.001) and in all genotypes of the TFPI polymorphism. Overall, concentrations of TAFI did not differ between the two groups but were reduced by hormone therapy in homozygotes for the rare TAFI -438 A allele (P < 0.05). The hormone effects on TFPI and TAFI were similar in smokers and non-smokers and in women using unopposed and opposed therapy. The observed decrease in TFPI may contribute to the increased cardiovascular risk associated with HRT.

Arteriosclerosis↗

Positive impact of hormone replacement therapy on the fibrinolytic system: a long-term randomized controlled study in healthy postmenopausal women.

BACKGROUND: The mechanisms by which postmenopausal hormone replacement therapy (HRT) may influence risk of cardiovascular disease are still unclear. Impaired fibrinolytic function is associated with an enhanced risk of cardiovascular disease and therefore the effect of HRT on fibrinolysis may be of importance. OBJECTIVES: To investigate the prolonged effect of HRT on the fibrinolytic system and to determine whether two common polymorphisms in the plasminogen activator inhibitor-1 (PAI-1) and tissue-type plasminogen activator (t-PA) genes modulate this effect. METHODS: Healthy postmenopausal women (n = 248) were randomized to HRT (n = 122) or no substitution (n = 126) 5 years prior to investigation. RESULTS: Significantly higher values of t-PA activity and lower values of PAI-1 activity and PAI-1 antigen were found in the HRT group compared with the control group. This effect was independent of smoking and without influence from the two common polymorphisms PAI-1 -675(4G/5G) and t-PA intron8ins311. Furthermore, no difference between opposed estrogen (with norethisterone acetate as the gestagen component) and unopposed estrogen therapy was found. Both an intention-to-treat and a per-protocol analysis were performed and similar results were obtained. CONCLUSIONS: Long-term treatment with HRT in healthy postmenopausal women was found to be associated with a beneficial fibrinolytic profile. This effect was found independent of smoking status, opposed and unopposed estrogen therapy had equal effect, and no influence of the two common polymorphisms PAI-1-675(4G/5G) and t-PA intron8ins311 was found. This effect of HRT on fibrinolytic capacity may be one of the beneficial effects of HRT in relation to cardiovascular diseases.

Drug Therapy, Combination↗

European Concerted Action on Anticoagulation (ECAA). An assessment of lyophilised plasmas for ISI calibration of CoaguChek and TAS whole blood prothrombin time monitors.

AIMS: The recommended method for the international sensitivity index (ISI) calibration of whole blood point of care testing (POCT) prothrombin time (PT) systems was originally described by Tripodi et al in 1993 but is too complex and demanding. The present European Concerted Action on Anticoagulation (ECAA) study aimed to assess the reliability of simpler ISI calibration using lyophilised plasma samples. METHODS: ISI calibrations using three different types of ECAA lyophilised plasma samples (artificially depleted, individual, and pooled coumarin) were compared with whole blood calibrations on CoaguChek Mini and TAS PT-NC POCT monitors at 10 centres. RESULTS: With CoaguChek Mini systems, lyophilised coumarin plasma samples (both single donation and pooled) gave ISI and international normalised ratio (INR) values comparable to whole blood. With artificially depleted plasma, ISI and INR values were too high. With TAS PT-NC systems, all three types of lyophilised plasma samples gave inaccurate ISI and unreliable INR results, similar to previous ECAA findings with fresh plasma calibrations. CONCLUSIONS: With CoaguChek Mini systems, ISI calibration can be simplified by the use of ECAA lyophilised plasma samples from coumarin treated patients. Further study is needed to devise a simpler calibration method for the TAS PT-NC system.

Adult↗

Hormone replacement therapy and hypercoagulability. Results from the Prospective Collaborative Danish Climacteric Study.

OBJECTIVE: To assess the influence of a variety of HRT regimens on the haemostatic balance using markers of fibrin turnover and inhibitors of coagulation. DESIGN: An open randomised study allocating women to either a control group or five different HRT treatment groups. SETTING: Gentofte Hospital, Hellerup, and Rigshospitalet, Copenhagen, Denmark. POPULATION: One hundred and forty-nine postmenopausal women without previous venous thromboembolic disease. METHODS: Prothrombin fragment 1+2 (F(1+2)), fibrin degradation products, antithrombin, protein C, total protein S and activated protein C-normalised ratio were measured at baseline and after 6 and 12 months of HRT in six groups of healthy postmenopausal women: (A). no HRT (reference group), (B). continuous oestradiol valerate (E(2)V) plus cyproterone acetate, (C). cyclic E(2)V plus cyproterone acetate, (D). continuous combined oestrogen (E(2)) plus norethindrone acetate, (E). E(2) combined with local delivery of levonorgestrel and (F). E(2)V plus medroxyprogesterone. HRT-induced changes in the concentration of inhibitors of coagulation and markers of fibrin turnover during 12 months of treatment. RESULTS: Significant decreases of antithrombin and protein S were found in all treatment groups, of protein C in Groups C, D, E and F and of activated protein C-normalised ratio in Groups E and F. Fibrin degradation products increased after three months of treatment, whereas F(1+2) was persistently increased after three months in Group F. The cumulative response of antithrombin was significantly lower in Groups D, E and F than in the reference group. The cumulative response of protein S and activated protein C-normalised ratio was lower, whereas that of F(1+2) was significantly higher in Group F than in the reference group. CONCLUSION: HRT reduces the inhibitory potential of coagulation significantly. The effect is related to the type of E(2)/progestin combination administered, but seems to be oestrogen-derived as the most pronounced effect is found with only quarterly progestin intake. Such procoagulant activity of HRT may well translate into clinical manifestations in thrombosis-prone individuals.

Adult↗

European Concerted Action on Anticoagulation (ECAA). Minimum number of centres for reliable International Sensitivity Index calibration of CoaguChek and TAS point-of-care whole blood monitors.

INTRODUCTION: Prothrombin time (PT) test systems require multicentre calibration for reliable International Sensitivity Index (ISI). Multicentre calibration of CoaguChek Mini and TAS PT-NC point-of-care test (POCT) systems is less precise than conventional PT testing. The aim of the present study was to determine the number of centres required to give reliable ISI and International Normalised Ratio (INR) with these two POCT whole blood PT monitors. MATERIALS AND METHODS: A simulation study, based on results of a 10-centre calibration exercise, was performed to assess reliability of ISI and INR when the number of centres was reduced from 10 to 2. RESULTS AND CONCLUSIONS: With both systems, the range of ISI and INR deviation increased as the number of centres was reduced. For the CoaguChek Mini, at least five centres were needed for satisfactory INR deviation in 95% of calibrations. With the TAS PT-NC, three centres gave satisfactory INR at this level. The number of centres required for multicentre calibration of these two POCT PT systems is greater than the two proposed by World Health Organisation (WHO) Guidelines for conventional PT testing.

Calibration↗

European Concerted Action on Anticoagulation (ECAA): multicentre international sensitivity index calibration of two types of point-of-care prothrombin time monitor systems.

A multicentre modified World Health Organization (WHO)-type international sensitivity index (ISI) calibration has been performed at 10 European Concerted Action on Anticoagulation (ECAA) national laboratories using non-citrated whole-blood on two point-of-care test (POCT) prothrombin time (PT) monitor systems, CoaguChek Mini and TAS PT-NC, using single lots of test cards/strips. The relevant species (human and rabbit) WHO international reference preparations (IRPs) were tested with the manual PT technique on citrated plasma from the same blood donations. The ISI was calculated from the slope of the orthogonal regression line relating log PT (POCT) to log PT (IRP). The mean ISI of the CoaguChek Mini system was 1.75 and 1.13 with the prothrombin time non-citrated Thrombolytic Assessment System (TAS PT-NC). With the CoaguChek Mini system, seven out of 10 calibrations exceeded the current 3% WHO recommended limit for the coefficient of variation (CV) of the slope with conventional PT testing, whereas with the TAS PT-NC system, it was eight out of 10. All the POCT calibrations had a CV of the slope <5%. It is suggested that this level of precision be adopted as the limit of acceptability of calibration of these monitor systems. In these circumstances, the modified WHO-type ISI calibration appeared to be satisfactory for the POCT whole-blood monitors.

Animals↗

Effects of different progestin regimens in hormone replacement therapy on blood coagulation factor VII and tissue factor pathway inhibitor.

BACKGROUND: Long-term hormone replacement therapy (HRT) reduces cardiovascular risk, but an early increased risk was reported in women with coronary heart disease. In such women the arterial intima can express tissue factor, and changes in coagulation factor VII (factor VII) and tissue factor pathway inhibitor (TFPI) may be deleterious. METHODS: We measured factor VII clotting activity, activated factor VII, and concentrations of factor VII and TFPI during 12 months in healthy post-menopausal women randomized to: (i). cyclic oral estrogen/progestin (n = 25); (ii). long-cycle oral estrogen/quarterly progestin (n = 32); (iii). continuous oral estrogen/progestin (n = 21); (iv). continuous oral estrogen/intrauterine progestin (n = 22); (v). no HRT (n = 26). Blood was collected at baseline, 3, 6 and 12 months. Additional sampling was done before progestin intake in the long cycle group. RESULTS: No variations were observed in the reference group. There was a substantial decrease in TFPI concentrations in the HRT groups irrespective of the type of progestin. In women receiving long-cycle treatment, all factor VII measures increased during the unopposed estrogen periods, and the increase was reversed after progestin intake. The integrated response, AUC, for TFPI was significantly lower in the HRT groups compared with the reference group. CONCLUSION: The observed changes may increase the early thrombotic risk associated with HRT use.

Cholesterol, LDL↗

Splanchnic extraction and clearance of tissue plasminogen activator (t-PA) after injection of recombinant t-PA (Actilyse) in resting healthy subjects is proportional to the arterial concentration.

The purpose of the study was to evaluate the splanchnic extraction of tissue plasminogen activator (t-PA) in normal healthy fasting subjects after the injection of recombinant t-PA (rt-PA; Actilyse). In nine healthy volunteers (five male, four female), 21-29 years of age, the concentration of t-PA was determined in plasma samples taken simultaneously from a femoral artery and a large liver vein after a bolus injection (5, 10 or 20 mg) of rt-PA. The splanchnic plasma flow rate, the plasma volume, and the splanchnic extraction fraction of t-PA were determined. After the rt-PA injection, the measured arterial concentration of t-PA decreased from 36 750 to 45 pmol/l for t-PA antigen and from 50 700 to 17 pmol/l for active t-PA. The splanchnic extraction fraction decreased from 0.95 to 0.02 for t-PA antigen and from 0.78 to 0.08 (n = 3) for active t-PA. The extraction fraction was proportional to the arterial concentration of t-PA when the arterial concentration of t-PA was above about 300 pmol/l (both t-PA antigen and active t-PA). The median splanchnic plasma flow rate was 911 ml/min (range, 651-1149 ml/min). In the individual subject, the splanchnic plasma flow rate remained constant during the experimental period. The main conclusion of the study is that the splanchnic clearance and extraction fraction of t-PA, following an injection of rt-PA in the resting fasting steady state, depends on the arterial concentration of t-PA. The higher the arterial concentration of t-PA, the higher the extraction fraction of t-PA.

Adult↗

European Concerted Action on Anticoagulation--comparison of fresh plasma and whole blood multicentre ISI calibrations of CoaguChek Mini and TAS PT-NC whole blood prothrombin time point-of-care monitors.

A procedure for using citrated fresh plasmas for International Sensitivity Index (ISI) calibration of two types of whole blood point-of-care test (POCT) prothrombin time (PT) monitor systems has been assessed in a multicentre study. The CoaguChek Mini and TAS PT-NC systems gave higher ISI with whole blood samples than with fresh plasma calibrations. However. there was good agreement between whole blood and fresh plasma monitor system International Normalised Ratio (INR) and the reference INR of target samples. Reliable INR can therefore be obtained with both whole blood and plasma samples on these two POCT systems based on their respective ISI. With the CoaguChek Mini system, the plasma calibration ISI can also be used to derive reliable INR with whole blood PT results. This was not possible with the TAS PT-NC system.

Animals↗