Bleeding and activation of coagulation during and after transurethral prostatectomy: importance of the acute-phase response and prostate specific antigen?

OBJECTIVE: To evaluate the importance of coagulation activation in patients with benign prostatic hyperplasia, undergoing transurethral prostatic resection (TURP) and to examine whether changes in activity are related to blood loss, the circulatory entry of prostate specific antigen (PSA), operative trauma (resected tissue weight) and the inflammatory response, as assessed by C-reactive protein (CRP). PATIENTS AND METHODS: TURP was performed in 24 men and the weight of resected tissue and blood loss determined. The activation of coagulation was followed using new sensitive and specific assays, and the changes related to blood loss, the release of PSA, operative trauma and the acute-phase response. The area under the curve (AUC) for the measured quantities was used in correlation analysis. RESULTS: TURP was followed by a marked activation in coagulation. There was no correlation between the markers of coagulation and the operative blood loss, but the latter correlated with the weight of resected tissue (P=0.001). Postoperatively, the blood loss correlated with prothrombin fragment (F1+2; P=0.010), with thrombin-antithrombin complexes (TAT; P=0.024), and with the PSA concentrations (P=0.016) but not with fibrinogen. Serum concentrations of PSA increased significantly and the AUC in the operative period correlated with F1+2 (P=0.003) and TAT (P<0. 005), but postoperatively only with F1+2 (P=0.013). The weight of resected tissue correlated operatively with PSA (P=0.012) but not with the concentrations of F1+2 or TAT. Postoperatively, there was a correlation with the acute-phase proteins, CRP (P=0.005), fibrinogen (P=0.012) and with PSA (P=0.020). CONCLUSION: The operative blood loss is caused by surgical factors and the observed postoperative hypercoagulable state can be explained as a physiological response to bleeding, i.e. to secure haemostasis. The activity of coagulation was unrelated to operative trauma, but the acute-phase proteins were. The release of PSA into the circulation probably has an effect on blood coagulation.

Acute-Phase Reaction↗

Are olive oil diets antithrombotic? Diets enriched with olive, rapeseed, or sunflower oil affect postprandial factor VII differently.

BACKGROUND: The incidence of ischemic heart disease (IHD) in Crete was lower than expected on the basis of blood lipid concentrations of participants in the Seven Countries Study. A favorable effect of a high intake of olive oil on thrombogenesis may have contributed to this finding. OBJECTIVE: We compared the effects of virgin olive oil with those of rapeseed and sunflower oils on blood coagulation factor VII (FVII), a key factor in thrombogenesis. DESIGN: In a randomized and strictly controlled crossover study, 18 healthy young men consumed diets enriched with 5 g/MJ (19% of total energy) olive oil, sunflower oil, or rapeseed oil for periods of 3 wk. On the final day of each period, participants consumed standardized high-fat meals (42% of energy as fat). Fasting and nonfasting blood samples were collected after each period. RESULTS: Mean (+/-SEM) nonfasting peak concentrations of activated FVII (FVIIa) were 11.3 +/- 5.1 U/L lower after olive oil than after sunflower oil, an 18% reduction (P < 0.05). Olive oil also tended to cause lower FVIIa peak concentrations than did rapeseed oil (mean difference: 8.6 U/L, a 15% reduction; P = 0.09). There were no significant differences between diets with respect to nonfasting factor VII coagulant activity (FVII:c), prothrombin fragment 1+2 (F1+2), and tissue factor pathway inhibitor (TFPI) concentrations, or with respect to fasting plasma values of FVII protein, FVII:c, FVIIa, F1+2, or TFPI. CONCLUSION: A background diet rich in olive oil may attenuate the acute procoagulant effects of fatty meals, which might contribute to the low incidence of IHD in Mediterranean areas.

Adult↗

DNA-polymorphisms and plasma levels of vascular disease risk factors in Greenland Inuit--is there a relation with the low risk of cardiovascular disease in the Inuit?

Greenland Inuit are a population with a low risk of cardiovascular disease. Recently, we stated that frequencies of potentially high risk alleles of the apolipoproteins, fibrinogen, factor V, glycoprotein IIIa and factor VII (FVII) genes have different allele frequencies in the Inuit when compared with Caucasian populations. We have extended this study and evaluated whether or not this was also true for the genetic polymorphisms of tissue-type plasminogen activator (t-PA), plasminogen activator inhibitor-1 (PAI-1), angiotensin-converting enzyme (ACE) and angiotensinogen in a group of 133 Greenland Inuit, aged 30-34 gamma. In addition, we compared the plasma levels of these factors and those of C-reactive protein (CRP) and D-Dimer in Inuit and in Danes, comparable for age and gender. Frequencies (f) were assessed of the alleles that are known as the potential high risk alleles in Caucasians. In the Inuit, the f(insertion allele) of the t-PA intron8ins311 polymorphism was 0.37 (CI 0.32-0.43), the f(4G allele) of the PAI-1 promoter polymorphism was 0.88 (CI 0.83-0.91), the f(deletion allele) of the ACE intron16ins287 polymorphism was 0.40 (CI 0.33-0.47) and the f(M-allele) of the angiotensinogen M/T353 polymorphism was 0.30(CI 0.25-0.38). As for fibrinogen and FVII polymorphisms, these frequencies are all significantly different from what is reported for Caucasian populations. In the Inuit, plasma levels of fibrinogen and D-Dimer were higher than in the Danes, the PAI-1 levels were lower and FVII, t-PA and CRP levels were comparable. The observed allele frequencies of the polymorphisms of t-PA, fibrinogen, FVII, ACE, angiotensinogen and the plasma levels of PAI-1 and D-Dimer were in accordance with the low CVD risk in the Inuit, considering the observed associations between these measures and CVD risk in Caucasian populations, but for other measures this was not the case (allele frequencies of the PAI-1 polymorphism, and plasma levels of fibrinogen, FVII and t-PA). In conclusion there are clear differences in genetic background and plasma levels of risk factors in Greenland Inuit compared with Caucasian populations, and these differences were sometimes, but not always, in accordance with the observed low cardiovascular disease risk of the Inuit population.

Adult↗

Correction for lack of coincidence of normal and abnormal calibration slopes in ISI determination.

An underlying assumption of the WHO orthogonal regression model for prothrombin time standardisation is that a single line describes the relationship between PT of abnormal and normal plasmas. The aim was to evaluate Tomenson's correction for lack of coincidence using the model of the ECAA human reagent with lyophilized plasma calibrations. Local ISI calibrations using ECAA lyophilized normal and abnormal plasmas were performed on coagulometers with the ECAA human thromboplastin. They gave a high incidence of non-linearity of the two calibration slopes. The mean percentage deviation from assigned values of the target coumarin plasmas coagulometer INR at 45 centres before local ISI correction was 16.6% and 11.9% respectively in two studies. After local ISI calibration. the unsigned deviation was reduced to 5.54% and 6.61% respectively. Tomenson's correction for non-linearity further reduced the mean deviation to 3.08% and 2.96% respectively in the two studies demonstrating the value of the procedure.

Humans↗

Longevity is independent of common variations in genes associated with cardiovascular risk.

Do extremely old persons have a genetically favourable profile which has protected them from cardiovascular death? We have tried to answer this question by measuring DNA polymorphisms of selected cardiovascular risk indicators [factor VII, FVII (R/Q353, intron 7 (37bp)n, and -323ins10), beta fibrinogen (-455G/A), plasminogen activator inhibitor type 1, PAI-1 (-675(4G/5G)), tissue plasminogen activator, t-PA (intron 8 ins311), platelet receptor glycoprotein IIb/IIIa, GPIIb/IIIa (L/P33), prothrombin (20210G/A), methylene tetrahydrofolate reductase, MTHFR (A/V114), angiotensin converting enzyme, ACE (intron 16 ins287), and angiotensinogen (M/T235)]. Blood was collected from 187 unselected Danish centenarians, and 201 healthy Danish blood donors, aged 20-64 years (mean age 42 years). Genomic DNA was amplified using PCR and the genotype was determined by RFLP methods or allele-specific amplification followed by agarose gel electrophoresis. The frequencies of the high-risk alleles in centenarians were: for FVII R/Q353 0.91; for FVII intron 7 (37bp)n 0.67; for FVII-323 ins10 0.90; for fibrinogen 0.16; for PAI-1 0.52; for t-PA 0.59; for GPIIb/IIIa 0.16; for prothrombin 0.008; for MTHFR 0.33; for ACE 0.52; and for angiotensinogen 0.36. Comparable frequencies were observed in the blood donors. Subgroup analysis of men and women separately gave similar results. The genotype frequencies in the centenarians and the blood donors were similar for all polymorphisms, and this study suggests that common variations in genes associated with cardiovascular risk do not contribute significantly to longevity.

Adult↗

Multicentre randomised study of computerised anticoagulant dosage. European Concerted Action on Anticoagulation.

BACKGROUND: The demand for anticoagulant treatment is increasing. We compared the benefits of computer-generated anticoagulant dosing with traditional dosing decided by experienced medical staff in achieving target international normalised ratios (INRs). METHODS: In five European centres we randomly assigned 285 patients in the stabilisation period and stabilised patients to the computer-generated-dose group (n=137) or traditional-dose group (n=148). Centres had a specialist interest in oral anticoagulation but no previous experience with computer-generated dosing. The computer program calculated doses and times to next visit. Our main endpoint was time spent in target INR range (Rosendaal method). FINDINGS: For all patients combined, computer-generated dosing was significantly beneficial overall in achieving target INR (p=0.004). The mean time within target INR range for all patients and all ranges was 63.3% (SD 28.0) of days in the computer-generated-dose group compared with 53.2% (27.7) in the traditional-dose group. For the stabilisation patients alone, computer-generated doses led to a non-significant benefit in all INR ranges (p=0.06), whereas in the stable patients the benefit was significant (p=0.02). INTERPRETATION: The computer program gave better INR control than the experienced medical staff and at least similar standards to the specialised centres should be generally available. Clinical outcome and cost effectiveness remain to be assessed.

Administration, Oral↗

A comparison of artificially-depleted, lyophilized coumarin and fresh coumarin plasmas in thromboplastin calibration. European Concerted Action on Anticoagulation.

Artificially-depleted lyophilized plasmas and lyophilized coumarin plasmas were prepared and compared with fresh coumarin plasmas to assess their comparative reliability in local thromboplastin calibration using the manual prothrombin time (PT) technique. Their certified PT values were inserted in turn on the vertical axis in place of the PT obtained with fresh coumarin plasmas. PT results were obtained at eight ECAA national laboratories ('test centres') and inserted on the horizontal axis. The resulting thromboplastin calibration slopes were compared with conventional fresh coumarin plasma calibration slopes at the same 'test centres'. When 60 artificially-depleted plasmas were substituted for 60 fresh plasmas, the mean calibration slopes with the human plain International Reference Preparation (IRP) were 4.2% higher. For comparison with 20 lyophilized coumarins, three sets of 20 artificially-depleted plasmas were selected in sequential order from the 60. The lyophilized coumarin plasmas gave a mean deviation of 9.6% from the fresh plasma calibration slopes compared with values of 2.0%, 6.1% and 11.7% for the three sets of 20 depleted plasmas. Although both types of lyophilized plasma calibration slopes give measurable differences from conventional fresh plasmas, these may be regarded as acceptable in clinical terms.

Blood Coagulation Tests↗

A comparison of linear and orthogonal regression analysis for local INR determination in ECAA coagulometer studies. European Concerted Action on Anticoagulation.

International sensitivity index calibrations based on the W.H.O. recommended method depend on orthogonal regression analysis. As this is not readily available in statistical packages, comparison has been made with simple linear regression analysis in a study of coagulometer effects on the International Normalized Ratio (INR) at 155 European centres. Sets of seven lyophilized normal and 20 lyophilized artificially depleted abnormal plasmas were provided with five coumarin test plasmas and two European Concerted Action on Anticoagulation reference thromboplastins (low International Sensitivity Index (ISI) human and high ISI rabbit). Local ISI based on the artificially depleted lyophilized plasmas using conventional orthogonal regression gave good correction for local coagulometer effects on the human reagent and minimal correction with the rabbit reagent INR. Results were considerably worse after attempts at correction using calibration based on linear regression analysis with both reagents. The results indicate that calibration of coagulometer prothrombin time systems using simple linear regression is not appropriate.

Animals↗

Association of factor VII protein concentration with lifestyle factors.

Several studies have demonstrated that changes in fasting levels of factor VII coagulant activity (FVII:C), a thrombotic risk marker, are due to changes in FVII protein concentrations (FVII:Ag). Consequently, studies on FVII now often include measurements of FVII:Ag. The present cross-sectional study examined the association between several behavioural variables (body mass index, physical activity, tobacco or alcohol consumption) or physiological variables (total cholesterol, HDL-cholesterol, triglycerides, glucose, insulin, fibrinogen, resting pulse, systolic blood pressure, bleeding time) and FVII:Ag in 439 51-y-old Danish men. In the multivariate analyses, body mass index (BMI), low physical activity, total cholesterol, short bleeding time, and insulin showed an independent positive association with FVII:Ag. The strongest independent association with FVII:Ag was found for total cholesterol. These results suggest that blood lipids are major determinants of FVII:Ag, but that other lifestyle factors such as insulin, BMI and physical activity can also influence FVII:Ag. Furthermore, the association between FVII:Ag and bleeding time suggests an effect of FVII or the FVII pathway on primary haemostasis.

Adult↗

Minimum lyophilized plasma requirement for ISI calibration. European Concerted Action on Anticoagulation.

The minimum requirement of lyophilized plasma samples for a reliable International Sensitivity Index (ISI) was assessed by calibrations based on reducing numbers from a maximum of 60 depleted and 20 plasma samples from patients receiving coumarin using a manual technique and low ISI thromboplastin. The probability of achieving an international normalized ratio (INR) result within a clinically important range of 20% deviation has been assessed at European Concerted Action on Anticoagulation (ECAA) national laboratories in calibrations of ECAA reference thromboplastin against the certified prothrombin time (PT) with a reference thromboplastin. With conventional orthogonal regression using a certified PT and linear regression using certified INR, deviations and the coefficient of variation of the calibration slope increased with reduced numbers. The INR deviations became marked when the number of abnormal plasma samples was reduced to fewer than 20. Calibrations of 3 abnormal plasma samples and 1 lyophilized normal plasma sample gave a high incidence of deviations greater than 10% with an INR of 3.0. The study demonstrates that with both methods of analysis, an optimum minimum number of lyophilized plasma samples is needed for a reliable local ISI.

Calibration↗

The importance of "like to like" ISI calibrations with freeze dried plasmas. European Concerted Action on Anticoagulation.

AIM: To assess reliability of like to like and cross species calibrations using two types of certified freeze dried plasma calibrants--artificially depleted of vitamin K clotting factors, and from coumarin treated patients. METHODS: Six ECAA national control laboratories provided certified values for the freeze dried plasmas in terms of the human plain international reference preparation (IRP) (BCT/441) with the manual prothrombin time technique. Eight other ECAA national laboratories determined international sensitivity index (ISI) values in full fresh plasma same species and cross species WHO calibrations against a low ISI human IRP (BCT/441) of the ECAA low ISI human thromboplastin and high ISI ECAA rabbit thromboplastin. Parallel calibrations were performed using the certified values. RESULTS: Calibrations on fresh plasmas of the human ECAA reference thromboplastin (stated ISI = 0.95) gave ISI of 0.957 against the human IRP and 1.66 against the rabbit IRP. The ECAA rabbit (stated ISI = 1.67) gave an identical value on the fresh plasma calibration v the human IRP. With freeze dried depleted plasmas certified in terms of the human IRP, the ISI of the ECAA human was 1.01, but the ECAA rabbit (stated ISI = 1.67) gave a low ISI of 1.47. The freeze dried coumarin plasmas gave an ISI of 0.943 for the ECAA human but only 1.493 for the ECAA rabbit. CONCLUSIONS: Fresh plasmas give reliable ISI when calibrating thromboplastins in same species and cross species calibrations. Freeze dried plasmas certified in terms of a single IRP, whether artificially depleted or of coumarin plasma origin, cannot be used for calibration of dissimilar thromboplastins.

Anticoagulants↗

The European Concerted Action on Anticoagulation (ECAA) evaluation of a set of lyophilized normal plasmas to establish the normal prothrombin time for coagulometer systems.

Establishing the mean normal prothrombin time (MNPT) from fresh samples for prothrombin ratios and INR often presents difficulty in selection and collection of donors. A set of seven lyophilized normal plasmas has therefore been prepared at the ECAA Central Facility and studied at 143 laboratories in sixteen European states using coagulometers in serial field exercises. All centres tested either the high ISI ECAA rabbit or low ISI ECAA human reference thromboplastin. The MNPT of fresh plasmas and means of the lyophilized samples were closely comparable with most routine rabbit thromboplastins. Using human thromboplastins means with the lyophilized normals were marginally but significantly longer and with the bovine Thrombotest significantly shorter than the MNPT of fresh plasmas causing alterations in INR. There was no appreciable effect on INR of 2.5 and 3.5 when lyophilized normals were substituted for fresh normals with the rabbit reagents.

Animals↗

The European Concerted Action on Anticoagulation (ECAA): field studies of coagulometer effects on the ISI of ECAA thromboplastins.

Local calibration studies have been performed with lyophilized plasmas at 155 European laboratories to assess coagulometer effects on manual ISI of ECAA thromboplastins (low ISI human recombinant and high ISI rabbit brain). Common sets of 7 normal and 20 artificially depleted lyophilized plasmas were tested with the thromboplastins in the routine local coagulometers. With the human reagent, marked lowering of the manual ISI resulted with most coagulometers, which was associated with disproportionate shortening of the normals. Where this shortening did not occur, there was little coagulometer effect on the ISI. With the rabbit reagent, proportionate shortening with both normal and abnormal plasmas occurred in most instruments with little effect on ISI. INR correction by local ISI assignment appeared successful with the ECAA human reagent. There was negligible INR correction from local calibration of the ECAA rabbit reagent in coagulometers where thromboplastin ISI were unchanged from the ECAA established manual values.

Animals↗

The effect of chemical anti-inhibitors on fibrinolytic enzymes and inhibitors.

Fibrinolytic enzyme inhibitors hamper the determination of the specific fibrinolytic serine protease activity. Reportedly, chemical anti-inhibitors eliminate the influence of fibrinolytic inhibitors, but it remains unclear to what extent they change the specific activity of fibrinolytic serine proteases. We studied the influence of chemical anti-inhibitors (chloramine T, flufenamate, sodium lauryl sulfate, and methylamine) on fibrinolytic serine proteases and fibrinolytic enzyme inhibitors using the physiological substrate fibrin as plasmin substrate. Low concentrations of chloramine T (0.01 mmol/l) prevent the inhibition of plasminogen activators. Higher concentrations (1 mmol/l) reduce the inhibition of plasmin, but simultaneously quench the plasminogen activator activity. Flufenamate eliminates most fibrinolytic enzyme inhibitors, but increases the activity of plasmin (apparent recovery 140%) and plasminogen activators (apparent recovery > 200%). Sodium lauryl sulfate eliminates the major fibrinolytic enzyme inhibitors, but increases the activity of plasmin (apparent recovery > 200%) and plasminogen activator, urokinase type (apparent recovery 130%). Methylamine affects only plasmin inhibition. We conclude that chemical anti-inhibitors may invalidate the analytical specificity of methods for the determination of fibrinolytic serine protease activity.

Chloramines↗