PubMed Health⌕ Search

Biomedical subjects

J K Kuniyoshi

Publications and source records attributed to J K Kuniyoshi.

3 recordsLinked to original sources

Automated calculation of the centerline of the human colon on CT images.

RATIONALE AND OBJECTIVES: This article presents an evaluation of an automated technique for determining the colon centerline with computed tomographic (CT) data sets. MATERIALS AND METHODS: The technique proceeds as follows. After indication of a voxel in the rectum, voxels corresponding to air were segmented. Points along the colon centerline were estimated on the basis of centers of mass of grown voxels. A second segmentation and centerline calculation was initiated at the cecum. These two centerlines were then averaged. The resulting average was refined by using lumen data obtained perpendicular to the average centerline. The accuracy of the technique was investigated with simulation phantoms. The technique was also evaluated for 40 clinical colon cases. Calculated centerline points were compared with those indicated by radiologists for a randomly selected clinical case. RESULTS: In the simulation studies, the calculated centerline points were, on average, within 2.5 mm of the true centerlines but differed by up to 4 mm in regions of deep folds or sharp turns. In the clinical colon study, 40% of the centerlines were computed with a single seed point and 25% with two seed points. Average centerlines were computed in 1 minute. The root mean square difference between the computed centerline points and those indicated by the radiologists was 4-5 mm (comparable to interobserver variations). CONCLUSION: Accurate centerlines can be determined from colon CT data with this automated technique.

Colon↗

CT colonography with three-dimensional problem solving for detection of colonic polyps.

OBJECTIVE: We performed CT colonography in patients referred for conventional colonoscopy, interpreted the axial images, and used commercially available software to reconstruct endoluminal perspective views to differentiate polyps from folds. SUBJECTS AND METHODS: We prospectively examined 44 patients (27 men and 17 women; mean age, 58 years old) with CT colonography by interpreting the axial images and using three-dimensional rendering for problem solving only. The CT scans were interpreted by two radiologists who were unaware of patients' histories as revealed by colonoscopic findings. The findings on colonography were compared with those of conventional colonoscopy to determine sensitivity, specificity, time spent on interpretation, and confidence of interpretation. RESULTS: Colonoscopy showed normal findings in 28 patients and 22 polyps in the remaining 16 patients. Six polyps were 8 mm or larger, three were 5-7 mm, and 13 were 5 mm or smaller. The findings of the two observers revealed an overall sensitivity of 50% and 38%, respectively, and a specificity of 93% and 86%, respectively. Sensitivity for polyps larger than 8 mm was 83% and specificity was 100% for both observers. The average amount of time spent on interpretation was 28 min 30 sec (range, 14-65 min). Both observers used the endoluminal view for differentiating folds from polyps in 23 (52%) of 44 patients, which had only minimal impact on interpretation time. CONCLUSION: CT colonography can be performed and the images interpreted using currently available hardware and software by initially using the axial images to search for polyps of significant size. Endoluminal views should be used only when necessary to help distinguish normal folds from fixed raised lesions that are suggestive of polyps.

Colonic Polyps↗

Paramagnetic polymerized liposomes as new recirculating MR contrast agents.

We describe a well-tolerated blood pool contrast agent with extended recirculatory half-life based on paramagnetic polymerized liposomes (PPLs). PPLs were constructed from a new type of polymerizable lipid molecule that has a derivative of gadopentetate dimeglumine as the hydrophilic head group and diacetylene groups in the hydrophobic acyl chains, which cross-link when irradiated with ultraviolet (UV) light. Biodistribution, blood pool half-life, and MR image enhancement were determined for PPLs composed of 10% of the gadopentetate dimeglumine lipid and 90% of ditricosadiynoyl tricosadiynayl phosphatidylcholine (DAPC) at a dose of 0.015 mmol Gd+3/kg in rats. In T1-weighed MR images (TR/TE = 400/18 msec), an average signal enhancement of 34% in the kidneys and 20% in the liver was observed, which persisted for at least 90 minutes after administration of the PPLs. Biodistribution studies using radiolabeled PPLs confirmed that 80% of the injected dose remained in the blood pool after 2 hours. The half-life of elimination from the blood pool was 19 hours. The preparation was well tolerated in rats and produced similar MR contrast enhancement of the blood pool as produced by other liposome contrast agents. However, the half-life of PPL elimination from the blood pool was prolonged relative to other liposome systems.

Animals↗