PubMed Health⌕ Search

Biomedical subjects

J Kevin Harrison

Publications and source records attributed to J Kevin Harrison.

15 recordsLinked to original sources

Where's the flap?

We present a case of aortic intramural hematoma (IMH) in an elderly woman who presented with sudden onset of mid-scapular pain. The patient underwent a series of multimodality imaging studies before the diagnosis of IMH was evident by cardiovascular magnetic resonance, which is rapidly becoming the gold standard in the evaluation of acute aortic disease due to its high spatial resolution and ability to characterize tissue composition. Early diagnosis and prompt treatment is critical in improving the outcome of patients with IMH.

Aged↗

Peripheral blood levels of matrix metalloproteinases in patients referred for percutaneous balloon mitral valve commissurotomy.

BACKGROUND AND AIM OF THE STUDY: Inflammation may play a central role in the progression of stenotic valvular heart disease. Serum levels of matrix metalloproteinases (MMPs), markers of extracellular matrix (ECM) turnover and potential markers of active inflammation, have been recently demonstrated in several inflammatory processes. The present study was designed to examine whether systemic evidence of ECM turnover was present in advanced stenotic mitral valve disease. METHODS: Serum levels of MMP-1, -3 and -9 were measured in 114 patients with mitral stenosis referred for percutaneous balloon mitral valve commissurotomy, and compared to those in 48 healthy, age- and gender-matched controls. RESULTS: Serum levels of MMP-1, -3 and -9 did not vary according to hemodynamic profile or heart failure class at the time of blood sampling. Levels of MMP-1 and -3 were not significantly different between those patients with mitral stenosis and controls. The level of MMP-9 was significantly higher in patients with mitral stenosis than in controls, and did not appear to be altered by commissurotomy. CONCLUSION: Serum levels of MMP-9 were elevated in patients with mitral stenosis, providing further evidence that inflammation and ECM remodeling plays an important role in the pathophysiology of valvular heart disease.

Adult↗

The response to inhaled nitric oxide in patients with pulmonary artery hypertension is not masked by baseline vasodilator use.

BACKGROUND: Assessment of pulmonary vasodilator responsiveness is important in determining the prognosis and management of patients with pulmonary hypertension. Many patients, however, are already on vasodilators at the time of testing. It is unclear if these agents should be temporarily discontinued to improve the sensitivity of testing. METHODS: We examined the hemodynamic effects of nitric oxide (NO) inhalation in 60 patients with pulmonary arterial hypertension. Thirty-one of these patients were receiving medications with vasodilating properties. Vasodilator testing was performed with invasive measurement of pressure of the right side of the heart at baseline and during inhalation of 40 ppm NO. RESULTS: No significant demographic differences were seen between patients receiving and not receiving vasodilators. Similar reductions in mean pulmonary artery pressure (19 +/- 12% vs 20 +/- 12%, P = .734) and pulmonary vascular resistance (31 +/- 18 vs 32 +/- 16, P = .967) were seen in patients receiving and not receiving vasodilators. Using the definition of positive vasodilator response (> or = 20% drop in mean pulmonary artery pressure), 55% (17/31) of patients in the baseline vasodilator group had a positive response compared with 62% (18/29) of the patients not on vasodilators (P = .570). CONCLUSIONS: Concurrent use of oral vasodilators does not appear to mask a significant response to inhaled NO on the pulmonary vasculature. Therefore, routine discontinuation of pulmonary vasodilators is likely unnecessary before vasodilator testing in patients with pulmonary arterial hypertension.

Administration, Inhalation↗

Usefulness of percutaneous balloon mitral commissurotomy in preventing the development of atrial fibrillation in patients with mitral stenosis.

A prospective cohort of patients with mitral stenosis and no history of atrial arrhythmias showed no decrease in the incidence of atrial fibrillation (AF) after successful versus unsuccessful Inoue balloon percutaneous balloon mitral valve commissurotomy. Advanced age and left atrial dimension best predicted which patients developed AF during follow-up, whereas percutaneous balloon mitral valve commissurotomy procedural success and left atrial pressure reduction did not have an impact on incidence of AF.

Adult↗

Five-year clinical and echocardiographic evaluation of the Das AngelWings atrial septal occluder.

BACKGROUND: The late outcome of patients treated with atrial septal occluder devices remains incompletely defined. The purpose of this study was to assess the late outcome (range 4-7 years postprocedure) of patients in whom the Das AngelWings septal occluder device was implanted in the atrial septum. We report the clinical and echocardiographic outcome, at an average of 5 years following the procedure, of patients treated with the Das AngelWings device used to close either a secundum atrial septal defect (ASD) or a patent foramen ovale (PFO). METHODS: Thirty-two patients underwent successful percutaneous closure of an atrial septal closure, patent foramen ovale, or fenestration in the lateral tunnel of their Fontan with the Das AngelWings device between June 1995 and March 1998 at Duke University Medical Center. Two of the 32 patients were lost to follow-up. The remaining 30 patients were divided into 3 groups based on indication for device implantation. Group 1 consisted of 14 patients with a secundum ASD and predominantly left-to-right atrial shunting. Group 2 consisted of 8 patients who had a PFO and who suffered a thromboembolic event. Group 3 (compassionate use) consisted of 10 patients with multiple comorbid medical problems with predominantly right-to-left shunting at the atrial level causing hypoxemia. Eight of the patients in group 3 were severely ill at the time of device implantation. The 2 remaining patients in group 3 underwent AngelWings implantation for closure of right-to-left shunting through a Fontan fenestration. Mean follow-up was 59 months. RESULTS: There was no device embolization. No patient in the ASD or PFO/stroke group had a clinical complication. By radiographic examination, 2 of 27 patients had evidence of fracture of the nitinol framework at 2-year follow-up. Residual shunting was present in 44% at 24 hours, 20% at 1 year, and 18.8% at 2 years by use of Doppler color flow imaging and/or microcavitation echocardiographic studies. Mild mitral regurgitation caused by the AngelWings device occurred in 1 patient. One patient in the compassionate use group had a subsequent neurologic event. Five of the 10 patients in the compassionate use group died of comorbid illnesses in follow-up, none directly related to device complications. CONCLUSION: The late clinical outcome of secundum ASD and PFO/stroke patients in this study demonstrates that Das AngelWings closure of the atrial septum is effective and safe. These data are encouraging with respect to the expanding use of other percutaneously implanted ASD occlusion devices, although late clinical safety and efficacy data are needed for the specific devices being implanted.

Adolescent↗

Should we cross the valve: the risk of retrograde catheterization of the left ventricle in patients with aortic stenosis.

CLINICAL SCENARIO: A 67-year-old man is referred to your cardiology clinic complaining of worsening angina and dyspnea on exertion. Physical examination reveals a harsh grade IV/VI late-peaking crescendo-decresendo systolic murmur, loudest at the upper sternal border. The aortic closure sound is diminished. Echocardiography demonstrates left ventricular hypertrophy, an ejection fraction of 50%, no evidence of mitral regurgitation, and severe aortic stenosis (AS) with a peak aortic gradient of 4.8 m/s (92 mm Hg) and a mean aortic gradient of 55 mm Hg. You schedule him for coronary angiography but wonder whether you should reevaluate his aortic valve gradient invasively. LITERATURE SEARCH: Combining the keywords "aortic valve stenosis" and "heart catheterization/adverse effects," you find 72 articles. From these you choose the following: Omran H, Schmidt H, Hackenbroch M, et al. Silent and apparent cerebral embolism after retrograde catheterization of the aortic valve in valvular stenosis: a prospective randomized study. Lancet 2003;361:1241-6. QUESTION: What is the stroke risk of retrograde catheterization of the aortic valve in patients with AS? DESIGN: The study was prospective and randomized; unblinded treatment but with blinded assessment of outcomes. SETTING: The study was conducted at a single center in Bonn, Germany. PATIENTS: A total of 152 patients with known or suspected AS undergoing cardiac catheterization were randomized to catheterization with or without retrograde passage of the aortic valve in a 2:1 randomization format. Patients underwent brain magnetic resonance imaging (MRI) the day before and within 48 hours after cardiac catheterization. Patients with unclear echo findings or contraindications to MRI or transesophageal echocardiography were excluded. There were no significant baseline differences between the 2 groups: mean age 70.5 years, left ventricular ejection fraction 62%, and mean aortic valve gradient 51 mm Hg. All patients were evaluated in the groups to which they had been randomized and, other than the experimental intervention, the 2 groups were treated similarly (with the exception of the administration of 5000 units of intravenous heparin to the group receiving retrograde aortic catheterization). A control group of 32 patients without aortic valvular stenosis was evaluated as well. INTERVENTION: The intervention consisted of retrograde passage of the aortic valve for the purpose of obtaining an invasive aortic valve pressure gradient. MAIN OUTCOME MEASURES: The main outcome measures were acute cerebral embolic events, defined by MRI findings within 48 hours after catheterization (as compared to precatheterization MRI) and by clinical examination. MAIN RESULTS: Twenty-two of 101 patients (22%) assigned to retrograde catheterization developed new focal MRI abnormalities consistent with acute cerebral embolic events. Three of these patients (3%) demonstrated clinically apparent neurologic deficits. None of the patients who did not undergo retrograde catheterization--and none of the control patients--had MRI or clinical evidence of cerebral embolism.

Aged↗

Incidence and predictors of major vascular complications after percutaneous coronary intervention in the glycoprotein IIb/IIIa platelet inhibitor era.

Since the introduction of platelet glycoprotein (GP) IIb/IIIa inhibitors, reports of vascular complications after percutaneous coronary intervention (PCI) have focused on bleeding and the need for surgical repair, whereas specific major vascular complications have been less consistently identified. Moreover, data from clinical trials may lack applicability to the general population. The purpose of this study was to determine the incidence of major vascular complications after PCI and to identify associated risk factors in patients routinely receiving GP IIb/IIIa inhibitors. During a 12-month period, 1,634 consecutive patients underwent PCI at a single institution. Clinical characteristics and procedural data were collected prospectively; data regarding vascular sheath removal were obtained retrospectively. Univariate and multivariable regression methods were used to identify independent predictors of major vascular complications. Major vascular complications occurred in 2.9% of patients. Multivariable analysis revealed advanced age (odds ratio [OR] 1.05, P = 0.0025) and female sex (OR 2.9, P = 0.0002) as clinical characteristics associated with major vascular complications, whereas hypertension had an inverse relationship (OR 0.46, P = 0.013). Procedural factors included use of the following: stents (OR 5.59, P < 0.0001), vascular sheaths >6F (OR 3.25, P = 0.016), and mechanical clamp (OR 2.71, P = 0.0012). The presence of a hematoma >4 cm(2) had a positive predictive value of 12% for major vascular complications. The incidence of major vascular complications in this large, single-center study from the GP IIb/IIIa inhibitor era is consistent with data from the pre-GP IIb/IIIa inhibitor era and recent randomized trials.

Abciximab↗

Trained and supervised physician assistants can safely perform diagnostic cardiac catheterization with coronary angiography.

Using a prospectively collected database of patients undergoing cardiac catheterization, we sought to compare the outcomes of procedures performed by supervised physician assistants (PAs) with those performed by supervised cardiology fellows-in-training. Outcome measures included procedural length, fluoroscopy use, volume of contrast media, and complications including myocardial infarction, stroke, arrhythmia requiring defibrillation or pacemaker placement, pulmonary edema requiring intubation, and vascular complications. Class 3 and 4 congestive heart failure was more common in patients who underwent procedures by fellows compared with those undergoing procedures by PAs (P = 0.001). PA cases tended to be slightly faster (P = 0.05) with less fluoroscopic time (P < 0.001). The incidence of major complications within 24 hr of the procedure was similar between the two groups (0.54% in PA cases and 0.58% in fellow cases). Under the supervision of experienced attending cardiologists, trained PAs can perform diagnostic cardiac catheterization, including coronary angiography, with complication rates similar to those of cardiology fellows-in-training.

Aged↗

C-reactive protein elevation independently influences the procedural success of percutaneous balloon mitral valve commissurotomy.

BACKGROUND: Markers of systemic inflammation including C-reactive protein (CRP) appear to predict morbidity and mortality in various clinical conditions. The presence of systemic inflammation and its impact on the procedural success of percutaneous balloon mitral valve commissurotomy (PBMC) in patients with rheumatic mitral stenosis has not been previously demonstrated. METHODS: Measurements of CRP with a high-sensitivity assay were performed at the time of PBMC or during post-procedural follow-up in 119 patients with mitral stenosis of rheumatic morphology. Patients were questioned to exclude confounders of CRP elevation and categorized into undetectable (< or =0.10 mg/L) and detectable (>0.10 mg/L) CRP levels. Detectable levels were further classified into assay range (>0.10 and < or =6.0 mg/L) and elevated (>6.0 mg/L). RESULTS: CRP was detectable in 76% of patients and elevated (>6.0 mg/L) in 36% of patients studied. Procedural success occurred in 89% of patients with undetectable CRP, as compared with only 67% in patients with detectable CRP (P =.028). This effect remained after controlling for age and valve score (previously described predictors of PBMC success). CONCLUSIONS: Systemic inflammation is common in patients with rheumatic mitral valve stenosis, and the relationship between procedural success and CRP suggests persistent inflammation may affect the results of PBMC.

Aged↗

Serial echocardiographic evaluation of restenosis after successful percutaneous mitral commissurotomy.

OBJECTIVES: This study was designed to determine predictors of restenosis after successful percutaneous mitral commissurotomy (PMC) and its relationship to late clinical outcome. BACKGROUND: The restenosis rate after PMC and its relationship to late clinical outcome is poorly defined. METHODS: Serial echocardiography was performed in 310 patients who underwent PMC. Restenosis, defined as mitral valve area (MVA) <1.5 cm(2) and > or = 50% loss of initial MVA increase, was determined by both two-dimensional (2D) and Doppler echocardiography. Clinical, echocardiographic and cardiac catheterization variables were evaluated to determine predictors of restenosis. The relationship between restenosis and major adverse clinical events (death, repeat PMC or mitral valve replacement) and functional status was assessed. RESULTS: Acute procedural success occurred in 206 patients (66%), who were then followed for restenosis. The cumulative restenosis rate was approximately 40% at six years after successful PMC (44% by 2D and 40% by Doppler MVA). The only independent predictor of restenosis was echocardiographic score (restenosis at five years was 20% for score <8 vs. 61% for score > or = 8, p < 0.001). The decline in MVA and occurrence of restenosis was gradual and progressive during the follow-up period. Procedural results and baseline factors predicted event-free survival. Restenosis by 2D MVA was related to adverse events or New York Heart Association functional class 3 to 4 symptoms, but restenosis was not an independent predictor of clinical outcome by multivariate analysis. CONCLUSIONS: Restenosis is a common, gradual and progressive occurrence after successful PMC and is predicted by higher echocardiographic score. Restenosis is related to late adverse clinical outcome, though clinical outcome remains best predicted by the acute procedural results of PMC.

Aged↗

Successful percutaneous coronary intervention with stent implantation in anomalous right coronary arteries arising from the left sinus of valsalva: a report of two cases.

Percutaneous coronary intervention (PCI) in an anomalous right coronary artery arising from the left sinus of valsalva can be technically challenging because of difficulty in selectively cannulating the vessel. We present two cases of successful stent implantation in an anomalous right coronary artery arising from the left sinus of valsalva. In both cases, we used an oversized 6 Fr Judkins left guiding catheter, which provided excellent angiographic visualization and guide support for stent delivery.

Aged↗

Cost implications of closure of atrial septal defect.

We sought to evaluate the relative cost of surgical and device closure of atrial septal defect. Device closure for atrial septal defects is becoming an alternative to surgical closure. We examined the hospital-generated cost data in 13 patients who underwent surgical repair and 15 patients who underwent device closure of an atrial septal defects (ASD) or patent foramen ovale (PFO) during a prospective clinical trial of the device. The cost of device closure of ASD was 7,837 dollars less on average than surgical closure when the cost of the occlusion device was excluded (device closure cost 7,397 dollars +/- 2,822 dollars, surgical closure cost 15,234 dollars +/- 3,851 dollars; P < 0.001). When adjusted for a 5% failure rate of device closure, the cost savings was 7,076 dollars. Device closure of ASD results in substantial hospital-related cost savings that will be an important consideration once new devices are approved for clinical use.

Adult↗

An anomalous left coronary artery originating from the pulmonary artery in a 72-year-old woman: diagnosis by color flow myocardial blush and coronary arteriography.

An anomalous left coronary artery originating from the pulmonary artery (ALCAPA) is a rare congenital coronary abnormality often associated with myocardial infarction, congestive heart failure and sudden death. Survival to adulthood in individuals with this coronary anomaly is quite uncommon. Since mortality approaches 90% in infancy with untreated ALCAPA, early recognition and surgical correction are essential. Using both echocardiographic myocardial blush and coronary arteriography, we describe the new diagnosis of uncorrected ALCAPA in a 72-year-old woman and review contemporary methods for the diagnosis and management of this particular coronary anomaly.

Aged↗