PubMed HealthSearch

Biomedical subjects

J Koehnke

Publications and source records attributed to J Koehnke.

7 recordsLinked to original sources

Frequency dependence of binaural performance in listeners with impaired binaural hearing.

Binaural performance was measured as a function of stimulus frequency for four impaired listeners, each with bilaterally symmetric audiograms. The subjects had various degrees and configurations of audiometric losses: two had high-frequency, sensorineural losses; one had a flat sensorineural loss; and one had multiple sclerosis with normal audiometric thresholds. Just noticeable differences (jnd's) in interaural time, interaural intensity, and interaural correlation as well as detection thresholds for NoSo and NoS pi conditions were obtained for narrow-band noise stimuli at octave frequencies from 250-4000 Hz. Performance of the impaired listeners was generally poorer than that of normal-hearing listeners, although it was comparable to normal in a few instances. The patterns of binaural performance showed no apparent relation to the audiometric patterns; even the two subjects with similar degree and configuration of hearing loss have very different binaural performance, both in the level and frequency dependence of their performance. The frequency dependence of performance on individual tests is irregular enough that one cannot confidently interpolate between octaves. In addition, it appears that no subset of the measurements is adequate to characterize the performance in the rest of the measurements with the exception that, within limits, interaural correlation discrimination and NoS pi detection performance are related.

Acoustic Stimulation

Effects of roving level variation on monaural detection with a contralateral cue.

Monaural detection with a contralateral cue (MDCC) was measured with and without a 20-dB overall roving level to determine the contribution of loudness to performance on this task. Psychometric functions were obtained for three normal-hearing subjects as a function of the signal-to-noise ratio for pure-tone and 1/3-oct noiseband signals at 500 and 4000 Hz with a wideband noise masker. At 4000 Hz, the roving level degrades performance for the narrow-band noise signal by about 5.3 dB. In addition, the presence of the contralateral cue degrades performance for both the pure-tone and narrow-band noise signals at 4000 Hz by 3 to 6 dB. At 500 Hz, however, performance is not affected by the roving level, and is improved by 3 to 6 dB by the contralateral cue. These results indicate that loudness is being used as a cue only for detection of the 4000-Hz narrow-band noise.

Acoustics

Fringed correlation discrimination and binaural detection.

Results are reported from a series of binaural detection and interaural correlation discrimination experiments at 500 Hz. The experiments include fringed correlation discrimination in which the correlation change is restricted to a narrow (38 Hz) target band of frequencies and the reference correlation is maintained in a fringe band of frequencies. This experiment is designed to be analogous to a detection experiment with a narrow-band target; in both cases the correlation changes only inside the target band. A simplified theoretical framework is used to compare the results of the detection and correlation discrimination experiments. Results are consistent with the notion that binaural detection and interaural correlation discrimination are effected by a common mechanism when the reference correlation is unity (as in the NoS pi case). When the reference correlation is zero (as in the NuSo case), detection performance is significantly better than predicted from the measured ability to discriminate interaural correlation.

Attention

Range effects in the identification of lateral position.

Experiments on the identification of interaural time and interaural amplitude differences were conducted to evaluate the effects of stimulus range on identification performance. Three stimulus sets, large range (LR), small-range center (SRC), and small-range side (SRS), were used in experiments on interaural time and amplitude identification. As expected, data for both sets of measurements show worse resolution for LR than SRC or SRS, demonstrating that the ability to distinguish between two fixed interaural differences can be strongly influenced by the total range of such differences in the stimulus set.

Auditory Perception

Masking effects in binaural detection and interaural time discrimination.

This study was designed to investigate the effects of masker level and frequency on binaural detection and interaural time discrimination. Detection and interaural time discrimination of a 700-Hz sinusoidal signal were measured as a function of the center frequency and level of a narrow-band masking noise. The masker was a continuous, diotic, 80-Hz-wide noise that varied in center frequency from 250 to 1370 Hz. In the detection experiment, the signal was presented either diotically (NoSo) or interaurally phase reversed (NoS pi). In the interaural time discrimination experiment, the signal level needed to discriminate a 30-microseconds interaural delay was measured. As would be expected, the presence of the masker has a greater effect on NoSo detection than NoS pi detection, and for masker frequencies at or near the signal frequency. In contrast, interaural time discrimination can be improved by the presence of a low-level masker. Also, performance improves more rapidly as the signal/masker frequency separation increases for NoSo detection than for interaural time discrimination and NoS pi detection. For all three tasks, significant upward spread of masking occurs only at the highest masker level; at low masker levels, there is a tendency toward downward spread of masking.

Adult

Performance in several binaural-interaction experiments.

The relationship between interaural correlation discrimination and binaural detection was investigated using common experimental procedures and common subjects. Psychometric functions were obtained for four normal-hearing subjects at 500 and 4000 Hz using third-octave noise signals for the correlation discrimination experiment, and pure-tone signals and third-octave noise maskers for the detection experiment. Results from these two measurements, which were compared by expressing the signal-to-noise ratio as an equivalent change in interaural correlation, support the idea that interaural correlation discrimination and binaural detection are closely related. Since large intersubject differences in binaural performance were observed in these experiments, interaural-time, interaural-intensity, and monaural-intensity discrimination were measured in a second experiment. The results of the second experiment show large intersubject differences for the interaural tasks, but not for the monaural task.

Acoustic Stimulation

The comparative effects of signal sensation level and sound-pressure level on interaural time discrimination.

A series of experiments was performed to examine the extent to which precision of interaural time discrimination depends on the sound-pressure level (SPL) and/or sensation level (SL) of the signal. All experiments used a tone burst signal and a continuous white noise masker, which was either diotic or interaurally phase reversed. Results of the first experiment indicate that (1) at equal signal SLs, interaural time and intensity discrimination is more precise when measured with the added diotic noise, and (2) addition of the phase reversed noise, previously shown to cause less precise interaural time discrimination, has a similar effect on interaural intensity discrimination. In the second experiment, interaural time JNDs for a signal of constant SPL were measured as a function of noise level. Results show that a low-level diotic noise can benefit interaural time discrimination, particularly at 500 Hz. The third and fourth experiments were performed to measure interaural time discrimination as a function of increasing signal SPL but constant signal-to-noise ratio. The data show the JND decreasing with increasing signal SPL at nearly the same rate with or without the added noise, indicating that an increase in signal-to-noise ratio is not necessary for improved discrimination.

Auditory Perception