PubMed Health⌕ Search

Biomedical subjects

J Kubica

Publications and source records attributed to J Kubica.

At least 19 recordsLinked to original sources

Percutaneous coronary intervention triggers a systemic inflammatory response in patients treated for in-stent restenosis -- comparison with stable and unstable angina.

OBJECTIVE AND DESIGN: It is believed that the magnitude of the systemic inflammatory response induced by percutaneous coronary intervention (PCI) impacts on the long-term outcomes in patients with stable angina (SA) and unstable angina (UA). We aimed to determine whether an inflammatory response appears in in-stent restenosis (ISR) patients undergoing balloon angioplasty and to assess its pattern and magnitude in relation to SA and UA subjects. SUBJECTS: 80 patients (59 with SA, 10 with UA, 11 with ISR) were enrolled into the prospective study. TREATMENT: SA and UA patients undergoing single vessel coronary balloon angioplasty followed by stenting versus ISR subjects in whom only balloon angioplasty was performed. METHODS: C-reactive protein (CRP), serum amyloid A (SAA), tumor necrosis factor alpha (TNF-alpha) and interleukin 10 (IL-10) were measured in blood samples collected before and 6, 24 h and 1 month after the procedure. RESULTS: A comparable pattern of inflammatory response in terms of CRP and SAA concentrations in subjects undergoing PCI due to ISR and SA was discovered while in unstable patients its magnitude was substantially higher. CRP and SAA levels increased significantly in each group with the peak value at 24 h and the baseline levels remarkably correlated with the highest markers' concentrations. In contrast, preprocedural TNF-alpha concentrations were higher in ISR group when compared with SA and UA patients. Additionally, in ISR group a twofold increase in their values of borderline significance at 6 h was noted. SA and UA subjects were found to have significantly lower TNF-alpha levels at 6 and 24 h after the intervention though the marker concentrations markedly increased with peak values at 1 month. The levels of IL-10 did not differ at any time point between the groups. CONCLUSIONS: We suggest that PCI triggers a systemic inflammatory response in patients with ISR and considerable differences in its pattern when compared with SA and UA patients were demonstrated. Moreover, a high preprocedural TNF-alpha level and its increase provoked by PCI in the ISR group warrant the need for further investigation of its possible involvement in the restenosis process.

Angina Pectoris↗

Echocardiographic morphometry of the right chambers of the heart in permanent cardiac pacing.

Permanent cardiac pacing is a method of choice in the treatment of specific arrhythmias and conduction disturbances. Clinical studies show that cardiac performance diminished at the site of impulse spreading. It determines local hypotrophy below the position of the pacing lead (early electric activation) with hypertrophic changes in the opposite lying myocardium (late electric activation). It seems that morphological changes, especially research by intravital methods, so relevant in permanent pacing to today's invasive cardiologist, are not understood in full. In connection with this we decided, on the basis on the echocardiographic examination, to evaluate in detail the morphology of the right ventricle and atrium in patients with permanent pacing. Research was carried out on a group of 124 patients (68 males, 56 females) from 40-93 years of age (avg. 68 +/- 14 yrs): 86 patients had implanted pacemakers or AICD (group I), the control group consisted of 38 patients with other cardiac diseases without any pacemaker devices (group II). We measured echocardiographically the following diameters: end-diastolic and systolic diameters of the right ventricle/atrium in short and long axis, diameter of the tricuspid orifice valve and calculated area of the tricuspid orifice based on a special formula. Regarding the morphometric parameters of the right ventricle and right atrium, we confirmed that all diameters of group I were overshooting in correlation to group II. Those differences, such as RVd-short and -long, RVs-long, RVinflow, RA-long and -short, TRId, were statistically significant. Regarding the area of the tricuspid orifice (TRIa), we did not observe any changes in the two examined groups. We concluded that patients with implanted devices have changes in the morphometric parameters of the right ventricle, atrium and orifice, but they do not depend on the duration of pacemaker implantation.

Adult↗

Adjunctive stent implantation following directional coronary atherectomy in patients with coronary artery disease.

OBJECTIVES: This prospective case-control study evaluated the acute and long-term results of stent implantation preceded by debulking of the plaque by means of directional coronary atherectomy. BACKGROUND: In comparison with balloon angioplasty, intracoronary stenting produces a larger luminal diameter, maintains artery patency and reduces the incidence of restenosis. Optimal stent deployment is a pivotal factor for achieving the best results, but the bulk of the atherosclerotic plaque opposes stent expansion and may limit the success of the procedure. Debulking of the plaque may provide a better milieu for optimal stent deployment. METHODS: Directional coronary atherectomy followed by a single Palmaz-Schatz stent implantation was attempted in 100 patients. The successes, complications and angiographic results of the combined procedure were evaluated both acutely and during follow-up. Matched patients undergoing successful Palmaz-Schatz stent implantation alone during the same period served as controls. RESULTS: Atherectomy followed by stent implantation was performed in 94 patients with 98 lesions; periprocedural complications were observed in four cases. The stenosis diameter decreased from 76+/-9% at baseline to 30+/-13% after atherectomy (p < 0.0001), and 5+/-9% after stent implantation (p < 0.0001); it increased to 27+/-15% at 6-month angiography (p < 0.0001). During the 14+/-10 months of follow-up, none of the patients died or experienced myocardial infarction, but three patients underwent target lesion revascularization. The patients undergoing stent implantation alone achieved smaller acute gains, tended to have a higher late lumen loss, had a higher restenosis rate (30.5% vs. 6.8%, p < 0.0001) and showed a greater incidence of clinical events during follow-up (p < 0.0001). CONCLUSIONS: Debulking atherosclerotic lesions by means of directional coronary atherectomy before stent implantation is a safe procedure with a high success rate and a low incidence of restenosis at follow-up.

Atherectomy, Coronary↗

Correlation between clinical and morphologic findings in unstable angina.

This study was undertaken to verify the hypothesis that the discrepant findings in published reports on the prevalence of thrombus in unstable angina depend on the inclusion of different clinical subsets in the various studies. We therefore correlated the clinical characteristics of patients included under the label of unstable angina with the morphologic features assessed by coronary angiography and intravascular ultrasound, and with histopathologic findings of atherectomy specimens. Fifty-eight patients with unstable angina (class B of the Braunwald classification) undergoing coronary arteriography followed by either coronary angioplasty (n = 20) or directional coronary atherectomy (n = 38) were studied. Fifteen patients were in class IB and 43 were in class II to IIIB. Among these 43 patients with angina at rest, 28 had ST-segment elevation during pain, and 15 had ST-segment depression, and 26 developed negative T waves on the baseline electrocardiogram (ECG) as a result of prolonged or repeated episodes of resting chest pain. Intravascular ultrasound examination of the culprit lesion was performed in 43 patients before the interventional procedure, and histopathologic analysis of atherectomy specimens was performed in 38 patients. Complex lesion morphology by angiography was observed in 31 patients (53%) without any significant relation to various clinical subsets. Patients in Braunwald class IB had more calcific plaques than patients in class II to IIIB (p < 0.001). Among patients with angina at rest, those with negative T waves on the baseline ECG, as well as those with transient ST elevation during pain, had a significantly higher incidence of noncalcific lesions (p = 0.001 for both). Analysis of atherectomy specimens revealed acute coronary lesions (thrombus and/or intraplaque hemorrhage) in 18 patients (47%). The incidence of acute coronary lesions was significantly higher in patients with than without negative T waves on the baseline ECG (p = 0.005), and increased further when negative T waves were combined with ST elevation during pain (p = 0.001). Multivariate analysis revealed that the presence orf negative T waves on the baseline ECG was the only explanatory variable related to the presence of acute coronary lesions by histology (p = 0.03). Patient subsets included in the broad spectrum of unstable angina have different morphologic features and incidence of acute coronary lesions by histology. These data provide an explanation for the discrepant findings in published reports on the relevance of thrombus formation in the pathogenesis of unstable angina.

Angina, Unstable↗

[Evaluation of efficacy and mechanism of action of angioplasty and directed atherectomy assisted by intravascular ultrasonography].

Intravascular ultrasound (IVUS) is a unique method of coronary lumen visualization enabling also examination the structure of the artery wall. Aim of this study was to assess efficacy and mechanisms of action of balloon angioplasty (PTCA) and directional atherectomy by means of IVUS. IVUS examination was performed before and after mechanical revascularization procedure in 37 pts (DCA-19 pts, PTCA-18 pts). Both PTCA and DCA resulted in enlargement of the coronary artery lumen (2.29 +/- 1.19 mm2 vs 2.93 +/- 1.55 mm2) but, also external diameter of the vessel increased after the procedure (1.94 +/- 1.10 mm2 and 0.74 +/- 1.01 mm2 retrospectively). In 55.6% of cases after PTCA plaque rupture or artery wall dissection was observed, mainly in eccentric lesions (70%). IVUS allowed to recognize details of artery lumen and define efficiency of procedure. In about 15% cases decision to continue PTCA or DCA was made on the basis of IVUS images only. The mechanism in which PTCA modifies the artery lumen is diverse and depends on the structure of lesion. Factors possibly responsible for enlargement of the lumen are: stretching, squeezing and translocation of atheroma as well as cracking and dissections along the arterial wall. DCA effectiveness depends on the withdraw of the atheromatous deposit, however, in over one-half of cases also stretching has some effect.

Aged↗

Influence of plaque composition on luminal gain after balloon angioplasty, directional atherectomy, and coronary stenting.

This study was conducted to correlate the acute luminal enlargement achieved by three different nonsurgical revascularization procedures in 79 patients (32 treated by balloon angioplasty, 29 by directional atherectomy, and 18 by coronary stenting) with the morphologic characteristics of coronary plaques assessed by preprocedure intravascular ultrasound. The absolute luminal gain was 2.41 +/- 1.54 mm2 for balloon angioplasty, 3.17 +/- 1.8 mm2 for directional atherectomy, and 4.56 +/- 1.45 mm2 for coronary stenting (p = 0.00005). However, when luminal gain was corrected for the external vessel area (luminal gain index), such difference was no longer present (0.22 +/- 0.12 for balloon angioplasty, 0.24 +/- 0.15 for directional atherectomy, and 0.30 +/- 0.12 for coronary stenting, p = not significant). Concentric plaques treated by coronary stenting had a higher luminal gain index than eccentric plaques (p = 0.01). A comparison of the three devices showed that a similar luminal gain index was achieved in soft plaques, whereas coronary stenting was superior to directional atherectomy (0.41 +/- 0.10 vs 0.20 +/- 0.09, p = 0.002) and balloon angioplasty (0.41 +/- 0.10 vs 0.19 +/- 0.08, p = 0.0005) in concentric plaques. Coronary stenting also induced a greater luminal gain index than directional atherectomy in calcific plaques (0.30 +/- 0.11 vs 0.18 +/- 0.09, p = 0.04). In conclusion, these data show that plaque morphology assessed by preprocedure intracoronary ultrasound influences the acute luminal enlargement achieved by different coronary interventions. The knowledge of plaque composition may be useful in guiding the choice of the device to be used to obtain a larger acute luminal gain.

Adult↗

Influence of plaque morphology on the mechanism of luminal enlargement after directional coronary atherectomy and balloon angioplasty.

OBJECTIVE: To relate the mechanism of luminal gain after directional atherectomy and balloon angioplasty to the morphological characteristics of the coronary lesions, assessed by intravascular ultrasound imaging. DESIGN: Intravascular ultrasound imaging was performed before and after the revascularisation procedure to assess the contribution of wall stretching and plaque reduction in luminal gain. SUBJECTS: 32 patients undergoing balloon angioplasty and 29 undergoing directional coronary atherectomy. MAIN RESULTS: The main luminal area in vessels treated by balloon angioplasty increased from 1.51 (SD 0.30) to 3.91 (1.09) mm2 (P < 0.0001) with a concomitant increase in total vessel area from 11.44 (2.73) to 13.07 (2.83) mm2 (P < 0.0001). Therefore stretching of the vessel wall accounted for 68% of the luminal gain while plaque reduction accounted for the remaining 32%. This mechanism ranged from 45% in non-calcific plaques to 81% in echogenic plaques. The main luminal area in vessels treated by directional atherectomy increased from 1.49 (0.32) to 4.68 (1.73) mm2 (P < 0.0001), with a concomitant increase of total vessel area from 13.61 (4.67) to 15.2 (4.04) mm2 (P = 0.006). Thus stretching of the vessel wall accounted for 49% of the luminal area gain and plaque reduction for the remaining 51%. The presence of calcium influenced the relative contribution of these two mechanisms to the final luminal gain after directional atherectomy, since in calcific plaques stretching of the vessel wall accounted for only 9% of the luminal gain as compared to 56% in non-calcific plaques. After balloon angioplasty there was greater evidence of coronary dissections (32% v 3% after directional atherectomy, P < 0.01) and plaque fissure (60% v 0%, P < 0.01). Plaque fissure was more frequently seen in echolucent and concentric lesions, whereas dissections prevailed in echogenic and eccentric lesions. CONCLUSIONS: Intravascular ultrasound imaging may allow the assessment of acute changes in lumen and vessel wall after revascularisation procedures, and help in evaluating the potential effect of the structure and morphology of coronary lesions on the mechanism of luminal enlargement.

Adult↗

[Advantages and controversies regarding physiologic electrostimulation of the heart in sinus node disease].

UNLABELLED: Pacing mode in sinus node disease (SND) is one of controversies in cardiac pacing. We evaluated atrial pacing mode (AAI) in SND patients (pts). Between 1985 and 1994 AAI pacemaker was inserted in 179 pts due to symptomatic SND of varied etiology. RESULTS: The majority of pts (91.6%) were free from syncopal episodes after AAI implantation, in 15 pts (8.4%) syncopes were occasionally observed due to disturbances in pacemaker function, AVB III degrees, vaso-vagal syndrome, orthostatic hypotonia or atherosclerotic insufficiency of the cerebral circulation. In 49 (51%) out of 96 pts with brady-tachy syndrome (BTS), episodes of supraventricular tachyarrhythmia were not observed after AAI insertion and in the majority of the remaining pts the frequency of the episodes decreased significantly. Chronic atrial fibrillation developed in 5 (5.2%) pts. In some of the pts the symptoms related to chronic heart failure decreased or disappeared. A reoperation was performed in 44 (24%) pts due to electrode dislocation or fracture, atrio-ventricular conduction disturbances, an increase in pacing threshold or due to local infections. During the follow-up period 13 (7.3%) pts died of reasons unrelated to cardiac pacing therapy. CONCLUSION: In the majority of SND pts AAI pacing mode prevents from syncopal episodes caused by sinus node disfunction. It decreases the symptoms of heart failure in SND pts and stabilizes the sinus rhythm in the majority of BTS pts. Complications accompanying AAI do not post a major threat for the pts and can be easily resolved. They should by no means discourage from AAI implantation in SND.

Cardiac Pacing, Artificial↗

Effects of coronary angioplasty on left ventricular function.

It is well known that myocardial revascularization after successful coronary bypass surgery results in improved left ventricular function. Coronary angioplasty also results in successful revascularization, favorably affecting both stunned and hibernating myocardium. We studied 22 patients with chronic stable angina who underwent successful angioplasty for an isolated narrowing of the proximal or midportion of the left anterior descending artery. These patients also performed isometric exercises before and after angioplasty, which can be used to characterize left ventricular function. Revascularization after angioplasty induced an immediate improvement in left ventricular function in those patients with dysfunction secondary to hibernating myocardium. Further studies are needed to assess the possibility of the myocardial stunning phenomenon occurring after angioplasty in those patients without left ventricular improvement.

Angioplasty, Balloon, Coronary↗

Assessment of left ventricular function by isometric handgrip exercise after thrombolysis in patients with refractory unstable angina.

The handgrip test has been proposed for the evaluation of the hemodynamic reserve in patients with coronary artery disease and to quantitate the impairment of left ventricular (LV) function. The present study was designed to evaluate the effect of thrombolytic therapy in patients with refractory unstable angina in order to test the hypothesis that a reduction in intracoronary thrombosis could ameliorate their hemodynamic response to the handgrip test. During left heart catheterization, 20 patients with refractory unstable angina of recent onset performed a handgrip test before (HG1) and 24-72 hours after (HG2) being randomized to receive recombinant tissue-type plasminogen activator or placebo, according to a double-blind parallel group design. HG1 induced an increase in heart rate (p < 0.001), in systolic pressure (p < 0.001), and a reduction in ejection fraction (p < 0.05). Changes in LV end-diastolic pressure during baseline handgrip were highly different in individual patients, resulting in a trend toward an increase. Similarly, a different individual response was observed in the behavior of the isovolumetric and relaxation indices. In comparison with HG1, no difference was detected during HG2 in the 2 treatment groups with respect to changes in LV volumes, ejection fraction, LV systolic and diastolic pressures, +dP/dt, (dP/dt)/P, -dP/dt, and tau index. In patients with refractory unstable angina of recent onset, the handgrip test performed before and after thrombolysis did not prove to be useful in assessing directional changes of LV performance, mainly because of the different individual response to the baseline handgrip test.

Angina, Unstable↗

Influence of elastic recoil on restenosis after successful coronary angioplasty in unstable angina pectoris.

The elastic behavior of the dilated coronary vessel has been reported to affect the immediate results of coronary angioplasty. To determine whether elastic recoil may also influence the long-term restenosis process, 98 consecutive patients with unstable angina and 1-vessel disease were studied. An automated coronary quantitative program was used for the assessment of balloon and coronary luminal diameters. Elastic recoil was defined as the percent reduction between minimal balloon diameter at the highest inflation pressure and minimal lesion diameter immediately after coronary angioplasty. Follow-up coronary arteriography was performed 8 to 12 months after the procedure in all patients. The mean elastic recoil averaged 17.7 +/- 16% and was correlated to the degree of residual stenosis immediately after coronary angioplasty (r = 0.64; p < 0.001). Restenosis, defined as > 50% diameter stenosis at follow-up, developed in 53 patients (54%). There was no correlation between the degree of elastic recoil and the changes in minimal lesion diameter observed during follow-up, whereas a positive correlation between the amount of elastic recoil and the incidence of restenosis was documented (r = 0.84; p < 0.05). Thus, the elastic properties of the dilated vessel do not influence the active process of restenosis. However, because elastic recoil negatively influences the initial results of angioplasty, it is more likely that further reductions in lumen diameter during follow-up can reach a threshold of obstruction considered critical for a binary definition of restenosis.

Adult↗

[The evaluation of intracoronary stents by intravascular echography].

BACKGROUND: Intravascular ultrasound (IVUS) provides high resolution of vessel wall pathoanatomy, and because of the highly reflective nature of stent surfaces, can evaluate alterations in stent geometry. METHODS: This study was performed to assess, by IVUS stent, expansion patterns in patients undergoing implantation of metallic coronary stents, and the mechanisms of restenosis in those patients. Twenty-five patients were studied: 9 pts acutely and 16 pts at routine follow-up 5-8 months after Palmaz-Schatz stent placement. The images recorded by IVUS (25 Mhz 3.9F catheter Intertherapy Inc. California) were quantitatively analyzed for: luminal diameter (LD), luminal cross-sectional area (LA), cross-sectional diameter (SD) and area (SA), comprised by the stent struts. We used quantitative coronary angiography (QCA) (Image Comm System) to measure lumen diameter (LD) and luminal cross-sectional area (LA) in patients in whom IVUS was not performed at the moment of stent placement. These values were considered reference values of LD and LA of the stent at follow-up. RESULTS: During follow-up, patients showed a reduction of vessel lumen LD (2.09 +/- 0.17 mm) measured by IVUS, versus baseline LD (2.87 +/- 0.39 mm) measured by QCA. SD (2.76 +/- 0.31 mm) and SA (6.30 +/- 1.24 mm2) were unchanged in comparison with LD (2.87 +/- 0.39 mm) and LA (6.47 +/- 1.77 mm2) measured by QCA at the time of stent implantation. CONCLUSIONS: These data suggest that the mechanism of restenosis is due to intimal proliferation rather than stent collapse.

Angioplasty, Balloon, Coronary↗

[Left ventricular stroke volume in individuals with dual chamber pacemaker (DDD). Effect of atrioventricular delay].

UNLABELLED: Programming of atrioventricular delay in patients with dual chamber pacemaker is very important for left ventricular filling and has a consequence for its stroke volume. The aim of this study was to evaluate the influence of atrioventricular delay for left ventricular stroke volume during pacing at two different rates. The study was performed in 36 patients with DDD pacemaker aged from 30 to 81 years, mean 56.1 +/- 14.6. Using Doppler echocardiography we have assessed left ventricular stroke volume during two pacing rates (70 and 100 ppm) with four atrioventricular delays (100, 150, 200 and 250 ms). We have found statistically significant difference between stroke volume with various atrioventricular delays. During pacing rate of 70 ppm the maximal difference was 19% and 15% during 100 ppm. Comparing both pacing rates the distributions of hemodynamically optimal atrioventricular delays was also significantly different. The best atrioventricular delay from the hemodynamic point of view was 36 ms longer during 70 ppm of pacing rate than during 100 ppm (p = 0.0009). The most often optimal delay at 70 ppm was 190-200 ms, and the rarest optimal delay was 90-100 ms; during 100 ppm pacing respectively: 140-150 ms and 240-250 ms. We have observed considerable personal variability in the hemodynamic response for atrioventricular delay changing as well as in the hemodynamically optimal values of this parameter during both pacing rates. CONCLUSIONS: 1. Atrioventricular delay programming has significant influence on left ventricular stroke volume. 2. Programming of atrioventricular delay should be performed individually in every patient because of personal variability of optimal values of this parameter.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

[Complications associated with use of atrial electrodes].

The higher complication rate with atrial than ventricular leads make the physiological mode of pacing less popular. The aim of this study was to assess the complications associated with atrial leads. Between July 1985 and December 1991 we inserted 174 atrial leads in 165 patients (pts) with sick sinus syndrome or/and a-v block (AAI and DDD system respectively). A variety of different types of unipolar leads have been used: passive fixation simple or J shaped with the porous tip of vitreus-carbon (n = 49) and platinum-iridium (n = 78) or polished tip of Elgiloy (n = 18), active fixation (n = 29). The leads were manufactured by Siemens-Elema, CPI, Biotronik, Medtronic and Vitatron. All leads have similar acute electrical characteristics. The mean follow-up period lasted 28 months (12-83) until June 1992. We observed the following complications: displacement of electrode tip in 16 pts (9.7%), the disturbances of sensing in 10 pts (6%), 3rd degree of a-v block in 6 pts (5.4%) of 111 pts with AAI pacing, the exit-block in 3 pts (1.8%), suppuration in 3 pts (1.8%) in pacemaker area, various in 1 pt (0.6%). Total complication rate, which required reoperation was 20.6%. Complications associated with atrial leads implantation are not dangerous, may be easily treated and should not limit the indication for physiological pacing.

Adult↗

Atrioventricular conduction disturbances in patients with sinoatrial node disease and atrial pacing.

In sinoatrial node disease (SND) atrial pacing may be limited by progression of AV block. The incidence of AV block after AAI systems implantation range, according to various authors, from 0% to 12%. The aim of this study was to examine the AV conduction disturbances that forced a change in the mode of pacing in patients with AAI pacemakers. The information was collected retrospectively from a cohort of 122 patients. The follow-up period ranged from 5 to 83 months (mean = 35). Among these patients there were 37 with sinus bradycardia and 85 with bradycardia-tachycardia syndrome. Their mean age was 63 years. Before AAI pacemaker insertion, all patients had normal AV conduction on 12-lead ECG, and all but five had a Wenckebach cycle length shorter than 500 msec. Seven out of these 122 patients (5.7%) developed symptomatic conduction disturbances (second-degree type I AV block in five, second degree type II AV block in one, and third-degree AV block in one), necessitating a change from AAI to another mode of pacing. We conclude that progression of AV block after atrial pacemaker implantation in patients with SND is infrequent and mild in the majority of cases. Intraventricular disturbances such as left anterior hemiblock represent contraindication to AAI pacing particularly in patients who may be in need of antiarrhythmic drugs.

Arrhythmia, Sinus↗

Left atrial size and wall motion in patients with permanent ventricular and atrial pacing.

It is well known that during permanent ventricular pacing atrial arrhythmias and embolic complications occur much more frequently in comparison to permanent atrial or sequential pacing. Hemodynamic disturbances caused by ventriculoatrial conduction (VAC) are thought to be responsible for those complications. The aim of this study was to compare the left atrial size and its wall motion in three groups of patients with sick sinus syndrome. Group 1: 58 patients with VVI pacing and VAC observed (22 males, 36 females, aged 31-86, mean 62.3). Group 2: 43 patients with primary AAI pacing (13 males, 30 females, aged 27-74, mean 57.8). Group 3: 13 patients with AAI or DDD replacing the primary VVI mode due to pacemaker syndrome and/or heart failure, all with VAC present during VVI pacing (7 males, 6 females, aged 26-80, mean 59.8). Two-dimensional/M-mode echocardiography was performed in all these patients. In group 1 mean diastolic as well as mean systolic atrial diameters were significantly greater (P less than 0.005) and wall motion significantly smaller (P less than 0.005) in comparison to the other groups. Left atrial wall motion amounted to only 7.4% of the mean diastolic diameter in this group. Mean left atrial diastolic and systolic diameters and wall motion in patients with pacemakers preserving atrioventricular synchrony (group 2 and group 3) were almost identical and wall motion amounted to about 22% of the diastolic diameter in both these groups. We conclude that ventriculoatrial conduction leads to significant enlargement of left atrium and to the atrial wall-motion decrease. This predisposes to arrhythmias and embolic complications.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗