PubMed Health⌕ Search

Biomedical subjects

J L Lima

Publications and source records attributed to J L Lima.

36 records · Page 2Linked to original sources

Ion-selective electrodes for promethazine determinations in pharmaceutical preparations and application to flow injection analysis.

The construction and evaluation of PM-selective electrodes with a conventional configuration and without internal reference solution are described. Two different PVC membranes were prepared with PM tetraphenylborate dissolved in 2-nitrophenyl octyl ether (type A) or bis (2-ethylhexyl)sebacate (type B). When the electrodes were evaluated in 0.01 M ionic strength solutions, both presented linear responses from 5 x 10(-5) to 1 x 10(-2) M, slopes close to the theoretical value, practical detection limits of approximately 2 x 10(-5) M, reproducibilities of +/- 0.2 mV/day, and a quick response (< 20 s). Using phosphate buffer solutions (pH 6.0), type B electrodes presented a lower practical detection limit and a better reproducibility than type A. Selectivity against several cations was assessed by the separated solutions method, and the type B electrodes were generally more selective. The type B membrane was also used for the construction of tubular electrodes for the automatic analysis of pharmaceutical products by flow injection analysis (FIA). These tubular detectors, evaluated in a low dispersion FIA system, presented better selectivity and sensitivity than the corresponding conventional ones. Several pharmaceutical preparations were analyzed with both conventional and tubular electrodes. The results obtained by FIA presented relative deviations of < 2% when compared with those obtained from the United States Pharmacopoeia monographs.

Electrodes↗

Construction and evaluation of PVC conventional and tubular tripelennamine-selective electrodes: their application in pharmaceutical preparations.

The construction and evaluation of tripelennamine conventionally-shaped ion-selective electrodes and tubular detectors for the determination of this compound in pharmaceutical formulations are described. Electrodes with conventional configuration have been constructed without an internal reference solution, using several types of immobilized ionic sensors in PVC. The different electrode membranes were prepared by using tripelennamine tetraphenylborate as ionic-exchanger, dissolved in 2-nitrophenyl octyl ether (type A), dibutylphthalate (type B) and bis-(2-ethylhexyl)sebacate (type C) as plasticizer solvents. The general working characteristics of the different types of conventional electrodes were evaluated in tripelennamine solutions, with adjusted ionic strength, showing a linear response in the concentration range of about 4 x 10(-5) - 1 x 10(-1) M and a slope near the theoretical value. The electrodes presented a fast response (> 20 s) and a high reproducibility (> or = 0.2 mV per day). The electrode selectivity in the presence of some interferents, such as sodium, potassium, lithium, ammonium, chlorpheniramine, diphenydramine, promethazine, meclizine and pentazocine, was good, particularly for those whose sensor membrane was prepared with tripelennamine tetraphenylborate dissolved in 2-nitrophenyl octyl ether (type A). Tubular detectors were also prepared using the same sensor membrane and were evaluated in a low-dispersion flow-injection manifold. Under these conditions the detectors presented response characteristics similar to those of the corresponding conventionally-shaped electrodes. The analysis of different pharmaceutical forms (creams, syrups and gels) gave good results with mean recoveries of 99.8-100.6% when the experiments were conducted by direct potentiometry and 99.9-100.4% where the same determinations were conducted by flow-injection analysis with tubular detectors.

Chemistry, Pharmaceutical↗

Simultaneous assay of nitrite, nitrate and chloride in meat products by flow injection.

A flow injection (FI) analytical method for the simultaneous assay of nitrite, nitrate and chloride in meat products is reported. The method is based on the potentiometric determination of chloride using a tubular ISE and on the spectrophotometric determination of nitrite. The FI system consisted in splitting the flow after potentiometric detection using a tubular detector and the subsequent confluence of the flow before reaching the spectrophotometric detector. This allowed the reduction of nitrate to nitrite in part of the sample plug on an on-line copper cadmium reductor column. Since each channel had a different residence time, two peaks were obtained for nitrite and nitrite plus nitrate. Spectrophotometric determination was made after a diazotization-coupling reaction. The results obtained were in good agreement with reference procedures and showed adequate precision (RSDs less than 6% for chloride and nitrite and 2% for nitrate). A high sampling rate was obtained (120 determinations per hour corresponding to 40 samples per hour).

Chlorides↗

Potentiometric determination of formation constants of copper(II)/bile acid/peptide in aqueous solution.

A potentiometric method was used to study the equilibria in aqueous solution for the systems copper(II)/bile acid salt/peptide [bile acid salt-sodium cholate or glycocholate; and peptide-glutamic acid (glutamate), glutamine or glutamylglutamic acid], specifically to assess cooperative binding between small peptides and bile acids in the presence of copper(II). The results obtained suggest large cooperativity in formation of ternary complexes with amino acids when they are coordinated to copper(II) as bidentate ligands.

Amino Acid Sequence↗

FIA titrations of ephedrine in pharmaceutical formulations with a PVC tetraphenylborate tubular electrode.

A flow injection system for the titration of ephedrine in pharmaceutical products with potentiometric detection was developed. For this purpose a tetraphenylborate tubular electrode was constructed. The electrode was prepared without inner reference solution and with a PVC membrane based on tetrapentylammonium tetraphenylborate as ion exchanger and 2-nitrophenylphenyl ether as mediator solvent. Its operational characteristics were evaluated in a low dispersion manifold and compared with more conventionally shaped electrodes using the same sensor. In the pH range 2.5-11.5, the electrodes showed linear response between 3.8 x 10(-6) and 0.1 M with a slope of -56.4 mV/log[BPh4]. Ephedrine determinations in pharmaceutical products were carried out in a single channel manifold with a mixing chamber incorporated and using the tubular electrode as detector. Recovery rates of 98.6 +/- 2.5% were obtained in the analysis of tables, nasal drops and syrups with a sampling rate of about 60 h-1.

Electrodes↗

Sequential flow-injection determination of ionic and total calcium in saliva.

In this paper a flow injection manifold for the sequential determination of ionic and total calcium in a small (75 microL) sample of saliva is presented. This setup incorporates two detectors, a tubular potentiometric detector and an atomic absorption spectrophotometer, for determining the ionic and total calcium, respectively. Furthermore, the saliva samples can be injected directly into the manifold without any pre-treatment or loss of carbon dioxide. The results of the analyses of 20 saliva samples were in good agreement with those obtained by the two reference procedures, the direct potentiometry for ionic calcium and atomic absorption spectroscopy for total calcium. The paired Student's t-test showed that there were no statistical differences in the results obtained. The relative standard deviations of ten consecutive measurements of the same salive sample were approximately 3% for ionic calcium and 4% for total calcium. Effects of differences in coexisting ions, ionic strength, and pH between standard solutions and samples were negligible.

Calcium↗

Flow injection system based on the sandwich technique for saving expensive reagents.

We report the application of a sandwich technique in flow injection systems which afford low consumption of expensive reagents and two reagent recirculation systems. The potential applicability of the technique thus developed was assessed by determining glucose in serum samples by the enzymatic glucosidase/peroxidase method. It was possible to perform up to 450 determinations with the same amount of reagent used to perform 50 determinations by batch procedures. The sampling rate was 80 determinations per hour with a 0.9% relative standard deviation.

Blood Glucose↗

Vitamins B1 and B6 tubular electrodes as FIA detectors; their use in the analysis of pharmaceutical products.

Ion-selective electrodes without an inner reference solution and tubular potentiometric detectors for the determination of vitamins B1 and B6 in pharmaceutical preparations by flow injection analysis (FIA) are reported. The membranes were prepared with the vitamin tetra(2-chlorophenyl)borate (TCPB) dissolved in o-nitrophenyloctyl ether (o-NPOE) and immobilized on PVC. Intrinsic behaviour of the tubular detectors was assessed using a low-dispersion single-channel FIA manifold and was compared with conventionally-shaped electrodes using the same membrane. Data obtained in the determination of vitamins B1 and B6 in pharmaceutical preparations with a double channel flow injection manifold incorporating the tubular detectors are presented and compared with those obtained by the U.S. Pharmacopeia method and by direct potentiometry with conventionally-shaped electrodes.

Electrodes↗

[Benzoate determination in medicinal syrups with a PVC membrane ion selective electrode without inner reference solution].

Two electrodes sensitives to benzoate ion, without inner reference solution, in which tetraoctylammonium benzoate in dibutylphtalate (type A) or 2-nitrophenyloctylether (type B) immobilized in PVC are used in membranes, applied on a conductive support, were prepared. The response characteristics and behaviour of this low-cost electrodes are presented. The analytical application possibilities are discussed and shown as practical examples on analyses of the ion in medicals syrups.

Benzoates↗

Solid-state PVC flow-through benzoate electrode.

A general construction procedure for conventional shape ion-selective electrodes based on a conductive support prepared with a mixture of a non-conductive epoxy and graphite was used in the preparation of a flow-through benzoate electrode to be used as potentiometric detector in flow injection analysis manifolds. The membranes were prepared from tetraoctylammonium benzoate in o-nitrophenyloctylether immobilized on PVC. The results of the assessment of the tubular electrodes behaviour in low dispersion manifolds against that of conventional electrodes with the same membrane are reported. Data obtained with a double-channel flow injection manifold incorporating these tubular detectors for benzoate determinations in several commercially available pharmaceutical preparations are also presented.

Benzoates↗

Flow injection analysis of inorganic cationic species in serum and urine.

This paper describes three flow injection analysis (FIA) systems for the automatic determination of sodium, potassium, lithium, calcium, magnesium, zinc, copper and iron in certain biological fluids and compares the results obtained to those of flame photometry and atomic absorption spectrometry. The set-ups were designed to allow the samples to be prepared in the same manner as that used for batch procedures with the same analytical instrument. For determinations requiring a high sample dilution, it was found of definite advantage to split the stream and pass large amounts of liquid through the detection systems. The comparison of the results obtained by FIA and conventional methods yielded correlation coefficients in the range 0.990 to 0.999. The proposed methodology show good precision, with variation coefficients between 0.5% to 5%.

Calcium↗

PVC membrane electrode without inner reference solution for the direct determination of ephedrine in pharmaceutical preparations.

A PVC membrane electrode, without inner reference solution, based on an ion association extraction system responding to ephedrine is described. It incorporates an ephedrine-tetrakis (4-chlorophenyl)borate ion-pair complex in 2-nitrophenyloctyl ether. The prepared electrode exhibits a near Nernstian response (57.5 mV per decade) over the concentration range of 2 x 10(-5)-10(-1) M ephedrine in solutions of pH 2.5-9. The reproducibility of the electrode potentials were +/- 1 mV by day during at least 6 months. Response time was about 6 s for ephedrine concentrations between 10(-5) and 10(-1) M. Determinations of ephedrine in pharmaceutical preparations (tablets, nasal drops and syrups) by direct potentiometry gave an average recovery of 99.1% (w/w) and a mean standard deviation of 1.9% (w/w).

Chemistry, Pharmaceutical↗

Monosegmented flow-analysis of serum cholesterol.

A monosegmented flow system is designed for enzymatic spectrophotometric determination of cholesterol in blood serum. The sample (4.5 microliters), enzymatic reagent (150 microliters) and an air plug (100 microliters) are simultaneously inserted into a carrier stream buffered to pH 7.4 (potassium dihydrogenphosphate). In order to avoid the step of air removal, a relocating detector was used. This system handles about 42 samples per hour, yielding precise results (R.S.D. usually < 3.0%). Sensitivity is 46 mAU 1/mmol (mAU stands for milliabsorbance units), being the method linear up to 10.3 mmol/l cholesterol. Accuracy was assessed by running 30 samples already analysed by a conventional procedure: no statistical difference between methods was found at the 95% confidence level.

Buffers↗

Optimal design of an enzymatic reactor for flow injection analysis.

A simulation procedure for the optimization of enzymatic reactors used in sandwich flow injection systems is evaluated. The system is modeled as a plug-flow reactor with axial dispersion. To calibrate it, dispersion coefficients can be evaluated using residence time distribution techniques; meanwhile, enzymatic kinetics must be determined for the system considered, according to the values of the substrate conversion attained. The model has been linked to an optimization routine based on the Powell algorithm. The proposed approach has been evaluated in a system performing simultaneous determinations of glucose and glycerol, considered the common carbon sources in a fermentation process.

Biotechnology↗

[The growth curve in asthmatic children].

The growth of 209 children with moderate and severe bronchial asthma seen at two different Health Care Centers for Bronchial Asthma Patients: (ICr and USP) was studied. The two groups differ mainly in socioeconomic level. Age at the onset of the disease, as well as duration and severity of the illness were considered. The first manifestations of the disease occurred before two years of age in 68.4% of the children. There was a predominance of males over females, with an almost 2:1 ratio in severe cases. The relationship between socioeconomic level and severity of the disease was highly significant (p less than 0.002). Weight and height were predominantly in the 50 percentile or below. This predominance was more evident for height. The height percentiles were significantly lower for the ICr group (p less than 0.01). Only 5.7% of the population studied had been submitted to prolonged (more than 3 months) corticoid treatment.

Adolescent↗

Merging zones standard addition technique for determination of copper in beer by flow injection atomic absorption spectrophotometry.

A flow injection system for determination of copper in beer by atomic absorption spectrophotometry by the standard additions method is described. The manifold, based on the merging zone technique, prevents the burner head from clogging, as observed with the conventional reference method. With 5 standard additions, results are comparable with those of the reference method. Relative deviations were less than 5.8%, precision was better than 6.4%, and sampling rate was about 30 samples/ h. A less precise, less accurate, but faster procedure (75 samples/h) is possible with only 2 standard additions. The detection limit was 5 micrograms/L.

Beer↗