PubMed Health⌕ Search

Biomedical subjects

J L O'Brien

Publications and source records attributed to J L O'Brien.

At least 19 recordsLinked to original sources

Demonstration of a simple entangling optical gate and its use in bell-state analysis.

We demonstrate a new architecture for an optical entangling gate that is significantly simpler than previous realizations, using partially polarizing beam splitters so that only a single optical mode-matching condition is required. We demonstrate operation of a controlled-z gate in both continuous-wave and pulsed regimes of operation, fully characterizing it in each case using quantum process tomography. We also demonstrate a fully resolving, nondeterministic optical Bell-state analyzer based on this controlled-z gate. This new architecture is ideally suited to guided optics implementations of optical gates.

Journal Article↗

Demonstrating superior discrimination of locally prepared states using nonlocal measurements.

We experimentally demonstrate the superior discrimination of separated, unentangled two-qubit correlated states using nonlocal measurements, when compared with measurements based on local operations and classical communications. When predicted theoretically, this phenomenon was dubbed "quantum nonlocality without entanglement." We characterize the performance of the nonlocal, or joint, measurement with a payoff function, for which we measure 0.72 +/- 0.02, compared with the maximum locally achievable value of 2/3 and the overall optimal value of 0.75.

Journal Article↗

Measurement of quantum weak values of photon polarization.

We experimentally determine weak values for a single photon's polarization, obtained via a weak measurement that employs a two-photon entangling operation, and postselection. The weak values cannot be explained by a semiclassical wave theory, due to the two-photon entanglement. We observe the variation in the size of the weak value with measurement strength, obtaining an average measurement of the S1 Stokes parameter more than an order of magnitude outside of the operator's spectrum for the smallest measurement strengths.

Journal Article↗

Quantum process tomography of a controlled-NOT gate.

We demonstrate complete characterization of a two-qubit entangling process--a linear optics controlled-NOT gate operating with coincident detection--by quantum process tomography. We use a maximum-likelihood estimation to convert the experimental data into a physical process matrix. The process matrix allows an accurate prediction of the operation of the gate for arbitrary input states and a calculation of gate performance measures such as the average gate fidelity, average purity, and entangling capability of our gate, which are 0.90, 0.83, and 0.73, respectively.

Journal Article↗

Measuring entangled qutrits and their use for quantum bit commitment.

We produce and holographically measure entangled qudits encoded in transverse spatial modes of single photons. With the novel use of a quantum state tomography method that only requires two-state superpositions, we achieve the most complete characterization of entangled qutrits to date. Ideally, entangled qutrits provide better security than qubits in quantum bit commitment: we model the sensitivity of this to mixture and show experimentally and theoretically that qutrits with even a small amount of decoherence cannot offer increased security over qubits.

Journal Article↗

Measuring a photonic qubit without destroying it.

Measuring the polarization of a single photon typically results in its destruction. We propose, demonstrate, and completely characterize a quantum nondemolition (QND) scheme for realizing such a measurement nondestructively. This scheme uses only linear optics and photodetection of ancillary modes to induce a strong nonlinearity at the single-photon level, nondeterministically. We vary this QND measurement continuously into the weak regime and use it to perform a nondestructive test of complementarity in quantum mechanics. Our scheme realizes the most advanced general measurement of a qubit to date: it is nondestructive, can be made in any basis, and with arbitrary strength.

Journal Article↗

Demonstration of an all-optical quantum controlled-NOT gate.

The promise of tremendous computational power, coupled with the development of robust error-correcting schemes, has fuelled extensive efforts to build a quantum computer. The requirements for realizing such a device are confounding: scalable quantum bits (two-level quantum systems, or qubits) that can be well isolated from the environment, but also initialized, measured and made to undergo controllable interactions to implement a universal set of quantum logic gates. The usual set consists of single qubit rotations and a controlled-NOT (CNOT) gate, which flips the state of a target qubit conditional on the control qubit being in the state 1. Here we report an unambiguous experimental demonstration and comprehensive characterization of quantum CNOT operation in an optical system. We produce all four entangled Bell states as a function of only the input qubits' logical values, for a single operating condition of the gate. The gate is probabilistic (the qubits are destroyed upon failure), but with the addition of linear optical quantum non-demolition measurements, it is equivalent to the CNOT gate required for scalable all-optical quantum computation.

Journal Article↗

Progress in silicon-based quantum computing.

We review progress at the Australian Centre for Quantum Computer Technology towards the fabrication and demonstration of spin qubits and charge qubits based on phosphorus donor atoms embedded in intrinsic silicon. Fabrication is being pursued via two complementary pathways: a 'top-down' approach for near-term production of few-qubit demonstration devices and a 'bottom-up' approach for large-scale qubit arrays with sub-nanometre precision. The 'top-down' approach employs a low-energy (keV) ion beam to implant the phosphorus atoms. Single-atom control during implantation is achieved by monitoring on-chip detector electrodes, integrated within the device structure. In contrast, the 'bottom-up' approach uses scanning tunnelling microscope lithography and epitaxial silicon overgrowth to construct devices at an atomic scale. In both cases, surface electrodes control the qubit using voltage pulses, and dual single-electron transistors operating near the quantum limit provide fast read-out with spurious-signal rejection.

Journal Article↗

Ancilla-assisted quantum process tomography.

Complete and precise characterization of a quantum dynamical process can be achieved via the method of quantum process tomography. Using a source of correlated photons, we have implemented several methods, each investigating a wide range of processes, e.g., unitary, decohering, and polarizing. One of these methods, ancilla-assisted process tomography (AAPT), makes use of an additional "ancilla system," and we have theoretically determined the conditions when AAPT is possible. Surprisingly, entanglement is not required. We present data obtained using both separable and entangled input states. The use of entanglement yields superior results, however.

Journal Article↗

Density-dependent spin polarization in ultra-low-disorder quantum wires.

There is controversy as to whether a one-dimensional (1D) electron gas can spin polarize in the absence of a magnetic field. Together with a simple model, we present conductance measurements on ultra-low-disorder quantum wires supportive of a spin polarization at B=0. A spin energy gap is indicated by the presence of a feature in the range (0.5-0.7)x2e(2)/h in conductance data. Importantly, it appears that the spin gap is not constant but a function of the electron density. Data obtained using a bias spectroscopy technique are consistent with the spin gap widening further as the Fermi level is increased.

Journal Article↗

Novel synthesis of the glycosidase inhibitor deoxymannojirimycin and of a synthetic precursor D-lyxo-hexos-5-ulose.

[reaction: see text]. The synthesis of D-lyxo-hexos-5-ulose (5-ketomannose, 1,5-dicarbonyl sugar), a synthetic precursor to the glycoprocessing inhibitor deoxymannojirimycin, was carried out by an in situ epoxidation and hydrolysis of a trimethylsilyl-protected 6-deoxyhex-5-enopyranoside followed by facile removal of the protecting groups. A novel nine-step synthesis of deoxymannojirimycin has also been achieved from methyl alpha-D-mannopyranoside; this involved methanolysis of epoxides derived from an acetylated 1-azido-6-deoxyhex-5-enopyranoside followed by deprotection and catalytic hydrogenation.

1-Deoxynojirimycin↗

Neuropsychologic testing within 18 hours after cardiac surgery.

OBJECTIVE: To undertake neuropsychologic testing within 18 hours of cardiac surgery after fast-track anesthesia. DESIGN: Prospective study. SETTING: University hospital, single center. PARTICIPANTS: Fifty patients undergoing first-time elective coronary artery surgery. INTERVENTIONS: A neuropsychologic test battery was administered preoperatively and 18 hours and 5 days after surgery. MAIN RESULTS: Seven patients were withdrawn, and 9 patients did not attempt the postoperative tests (on both occasions) because of medical complications. Thirty patients completed > or =4 tests at both postoperative occasions. Of these, 9 patients (30%) showed a deficit in > or =2 tests at 18 hours postoperatively, and 3 (10%) showed a deficit at 5 days postoperatively. CONCLUSION: In the absence of medical complications and despite the difficulties, early postoperative neuropsychologic testing is possible after fast-track anesthesia. Such testing has the potential to more clearly define the course of cognitive decline after cardiac surgery.

Aged↗

Comparison of anxiety assessments between clinicians and patients with acute myocardial infarction in cardiac critical care units.

BACKGROUND: Although anxiety is common after acute myocardial infarction and can adversely affect physical recovery, it is not part of the routine clinical assessment of patients with myocardial infarction. Furthermore, evidence suggests that patients and clinicians differ significantly in their assessments of patients' anxiety levels. OBJECTIVES: To determine the extent to which clinicians assess anxiety in patients with acute myocardial infarction and to compare patients' self-ratings with their clinicians' assessments. METHODS: In a prospective, descriptive study, 101 patients used the Spielberger State Anxiety Index to assess their anxiety during the first 48 hours after admission for acute myocardial infarction. Patients' scores were compared with nurses' and physicians' assessments of the patients' anxiety as reported in the medical record. RESULTS: Only 45 patients (45%) had anxiety assessments noted in the record. Of those 45, 26 patients (58%) were described simply as anxious without any further description of the level of anxiety. Eleven (24%) of those 45 patients had behaviors of anxiety recorded, again without any indication of the level of anxiety. No association between patients' self-assessments and their clinicians' assessments was apparent (lambda = .03; P > .05). CONCLUSIONS: Anxiety was not routinely assessed, despite nearly half the patients reporting moderate to extreme anxiety when asked. When clinicians assessed anxiety, their assessments did not match patients' self-ratings of anxiety. A simple, easy-to-use instrument for discriminating levels of anxiety is needed.

Aged↗

A controlled trial of low-molecular-weight heparin (dalteparin) versus unfractionated heparin as anticoagulant during continuous venovenous hemodialysis with filtration.

OBJECTIVE: To compare the efficacy, safety, and cost of fixed-dose low-molecular-weight heparin (dalteparin) with adjusted-dose unfractionated heparin as anticoagulant for continuous hemofiltration. DESIGN: Prospective, randomized, controlled clinical trial. SETTING: University-affiliated adult intensive care unit PATIENTS: All patients requiring continuous hemofiltration for acute renal failure or systemic inflammatory response syndrome (SIRS) were eligible. Fifty-seven patients were enrolled. Eleven were excluded, seven because of major protocol violations and four died before hemofiltration. INTERVENTIONS: Patients received continuous venovenous hemodialysis with filtration with prefilter replacement at 500 mL/hr and countercurrent dialysate at 1000 mL/hr. Filters were primed with normal saline containing anticoagulant. Dalteparin-treated patients received a commencement bolus of 20 units/kg and a maintenance infusion at 10 units/kg/hr. Heparin-treated patients received a commencement bolus of 2000-5000 units and a maintenance infusion at 10 units/kg/hr, titrated to achieve an activated partial thromboplastin time in the patient of 70-80 secs. MEASUREMENTS AND MAIN RESULTS: The primary outcome measure--time to failure of the hemofilter--was compared using survival analysis. Twenty-two patients (13 with acute renal failure and nine with SIRS; total, 41 filters) were randomized to heparin. Twenty-five patients (16 with acute renal failure and nine with SIRS; total, 41 filters) were randomized to dalteparin. Mean (SE) activated partial thromboplastin time in the heparin group was 79 (4.3) secs. Mean (SE) anti-factor-Xa activity in the six patients given dalteparin who were assayed was 0.49 (0.07). Mean (SE) prehemofiltration platelet count was 225 (35.5) x 10(9) for heparin and 178 (18.1) x 10(9) for dalteparin (p = .24, unpaired Student's t-test). Mean (SE) prehemofiltration hemoglobin was 11.4 (0.61) g/dL for heparin and 10.6 (0.38) g/dL for dalteparin (p = .31, unpaired Student's t-test). PRIMARY OUTCOME: There was no significant difference in the time to failure between the two groups (p = .75, log rank test). For dalteparin, Kaplan-Meier (K-M) mean (SE) time to failure of the hemofilter was 46.8 (5.03) hrs. For heparin, K-M mean (SE) time to failure was 51.7 (7.51) hrs. The 95% CI for difference in mean time to failure was -13 to 23 hrs. The power of this study to detect a 50% change in filter life was >90%. SECONDARY OUTCOMES: Mean (SE) reduction in platelet count during hemofiltration was 63 (25.8) x 10(9) for heparin and 41.8 (26.6) x 10(9) for dalteparin (p = .57, unpaired Student's t-test). Eight patients given dalteparin and four patients given heparin had screening for heparin-induced thrombocytopenia; three of the dalteparin patients and one of the heparin patients were positive (p = 1.0, Fisher's exact test). There were three episodes of trivial bleeding and two episodes of significant bleeding for dalteparin, and there were three episodes of trivial bleeding and four episodes of significant bleeding for heparin (p = .53, chi-square test). The mean (SE) decrease in hemoglobin concentration during hemofiltration was 0.51 (0.54) g/dL for heparin and 0.28 (0.49) g/dL for dalteparin (p = .75, unpaired Student's t-test). The mean (SE) packed-cell transfusion volume during hemofiltration was 309 (128) mL for heparin and 290 (87) mL for dalteparin (p = .90, unpaired Student's t-test). Daily costs, including coagulation assays, of hemofiltration were approximately 10% higher using dalteparin than with heparin. CONCLUSIONS: Fixed-dose dalteparin provided identical filter life, comparable safety, but increased total daily cost compared with adjusted-dose heparin. Unfractionated heparin remains our anticoagulant of choice for continuous hemofiltration in intensive care.

Acute Kidney Injury↗

Evaluation of respiratory artifact correction techniques in multishot spiral functional MRI using receiver operator characteristic analyses.

Navigator corrections and low-spatial frequency (LSF) oversampling are investigated as methods for reducing respiration-related effects in multishot functional MRI. Both techniques take advantage of the smoothly varying or nearly constant phase variations linked to the respiration cycle. These techniques were tested in functional MRI studies with spiral k-space acquisitions. Receiver operator characteristic (ROC) analyses and the temporal variance averaged across the brain were used to evaluate their effectiveness. Both methods were found to increase the area under the ROC curve and to reduce the standard deviation, with the LSF oversampling method being more effective.

Artifacts↗

Only two of the Trichomonas vaginalis triplet AP51 adhesins are regulated by iron.

The sexually transmitted parasite Trichomonas vaginalis cytoadheres to the vaginal epithelium, and four candidate trichomonad adhesins have been identified. One such protein, termed AP51, was characterized further. To do this, we studied a 1 kb cDNA clone (AP51.2) isolated from a phagemid expression library, which encoded a fusion protein of approximately 38 kDa that was immuno-crossreactive with anti-AP51 serum and retained functional adhesive properties. We performed 5'-PCR amplification to recover the missing 5' end in order to provide the complete cDNA sequence for the gene encoded by AP51.2 (ap51-2). Other PCR products revealed almost complete sequences for two additional ap51 genes, making AP51 a member of a multigene family of at least three distinct proteins and genes. The ap51-1 and ap51-3 genes each encoded for 407 amino acids while ap51-2 encoded 408 amino acids, and not unexpectedly, these genes had a high percent identity at the DNA and amino acid levels. Mapping confirmed the sequence distinctions and uniqueness of the three ap51 genes. Southern analysis using gene-specific probes revealed the single copy nature of each of the ap51 genes, all of which were present among the numerous agar clones of single trichomonads of the isolates tested. Importantly, Northern analysis showed transcriptional regulation by iron of only the ap51-1 and ap51-3 genes but not ap51-2, perhaps indicating the presence of two bona fide isoforms of the ap51 genes. The 3'-untranslated region of ap51-3 had a short poly (A) tail as well as the sequence motif AUUUA, which may relate to differential degradation of ap51-3 transcripts, in comparison to ap51-1 and ap51-2. Finally, the ap51 genes had partial homology to the beta-subunit of succinyl-CoA synthetase, reinforcing the idea that molecular mimicry may play a role in host parasitism by T. vaginalis.

Adhesins, Bacterial↗

Early extubation following coronary artery bypass surgery: a prospective randomized controlled trial. The Fast Track Cardiac Care Team.

STUDY OBJECTIVES: To determine the safety of early extubation (EE) after coronary artery surgery. DESIGN: Prospective randomized controlled trial. SETTING: The cardiac surgery operating room and ICU of a university-affiliated teaching hospital. PATIENTS: One hundred eligible patients presenting for elective coronary artery surgery. INTERVENTIONS: Patients randomized to the EE group were administered a reduced dose of fentanyl (15 microg/kg) and an anesthetic compatible with EE, while patients randomized to the conventional extubation (CE) group were given fentanyl (50 microg/kg). MEASUREMENTS AND RESULTS: The time to extubation in the EE group (median, 240 min; range, 30 to 930 min) was significantly less than the CE group (median, 420 min; range, 125 to 1,140 min) (p<0.01). Twenty patients were withdrawn from the study according to protocol guidelines. There were no cases of reintubation or complications attributable to EE. CONCLUSIONS: By using an appropriate anesthetic technique and postoperative management, EE can be achieved following coronary artery bypass surgery without major complications.

Anesthesia↗