Cellular phone interference with external cardiopulmonary monitoring devices.

OBJECTIVES: To determine the potential effect (electromagnetic interference) of cellular telephones on external cardiopulmonary monitoring devices. METHODS: For this study, we tested 17 different medical devices with 5 portable telephones (4 digital, 1 analog) to assess the potential for electromagnetic interference. The telephones were tested in a normal operating mode to simulate a typical hospital environment with patients or their families using their cellular phones. The medical devices were connected to the appropriate simulators for proper operation while the tests were under way. The screens and alarms of the medical devices were monitored while the telephones were maneuvered in the y and z planes near the devices. Clinically important interference was defined as interference that may hinder interpretation of the data or cause the equipment to malfunction. RESULTS: Any type of interference occurred in 7 (41%) of the 17 devices tested during 54.7% of the 526 tests. The incidence of clinically important interference was 7.4%. CONCLUSIONS: Cellular telephones may interfere with the operation of external cardiopulmonary monitoring devices. However, most of the test results showed that the interference would rarely be clinically important.

Electrocardiography↗

Use of a transurethral microwave thermotherapeutic device with permanent pacemakers and implantable defibrillators.

OBJECTIVE: To determine whether a device (Urologix Targis system) used for transurethral microwave treatment interferes with sensing, pacing, and arrhythmia detection by permanent pacemakers and implantable cardioverter-defibrillators (ICDs). METHODS: We tested 13 pacemakers in both bipolar and unipolar sensing configurations and 8 ICDs in vitro. Pacemakers and ICDs were programmed to their most sensitive settings. Energy outputs of the microwave device were typical of those used clinically. The probe of the microwave device was anchored 1.2 cm from the pacemaker or ICD being tested. RESULTS: No sensing, pacing, or arrhythmic interactions were noted with any ICD or any pacemaker programmed to the bipolar configuration. One pacemaker (Guidant Vigor 1230) showed intermittent tracking when programmed to the unipolar configuration. CONCLUSIONS: Most patients with permanent pacemakers or ICDs can safely undergo transurethral microwave therapy using the device tested. Pacemakers and ICDs should be programmed to the bipolar configuration (if available) during therapy. The pacemaker or ICD should be interrogated before and after therapy to determine whether programming changes occurred as a result of treatment. However, our findings suggest that this is unlikely.

Artifacts↗

Contrasting heating patterns and efficiency of the Prostatron and Targis microwave antennae for thermal treatment of benign prostatic hyperplasia.

OBJECTIVES: To determine the design and performance characteristics of two microwave antennae for use in thermal treatment of benign prostatic hyperplasia. METHODS: Prostatron and Targis antennae were subjected to detailed physical examination and measurement. The heating patterns generated by these two types of antennae were characterized in detail using tissue-equivalent phantoms. Measurements of return loss as a function of frequency were conducted to evaluate the capacity of the antennae for impedance matching. Percent reflected power was calculated from the return loss results to provide a relative measure of potential for efficient delivery of thermal energy. RESULTS: The Prostatron antenna was found to be a monopole design consisting of a coaxial cable with a 3.3-cm length of inner conductor exposed at the tip. The Targis antenna was observed to be a dipole design with a 2.8-cm helical coil attached through a ground connection and a tap point to a coaxial cable. The heating pattern of the Targis antenna was symmetric; that of the Prostatron was asymmetric with substantial back heating along the catheter axis in the direction of the microwave power source. The mean extension of the 30 degrees C isotherm in the direction of the power source with the Prostatron antenna (71.5 mm; 95% confidence interval [CI], 63.4 to 79.6 mm) was 55% greater (P < 0.0005) than that with the Targis antenna (46.0 mm; 95% CI, 38.2 to 53.8 mm). Return loss with the Targis antenna declined sharply to a relative minimum value of -32.9 dB (95% CI, -73.8 to 8.0 dB) at 915 MHz, providing evidence of this antenna's capacity for impedance matching; little change was observed with the Prostatron in return loss over a frequency range 100 MHz above and below this antenna's standard operating frequency of 1296 MHz. The mean reflected power of the Targis antenna (0.4%; 95% CI, 0.0% to 1.4%) was lower by more than 20-fold (P = 0.036) than that of the Prostatron antenna (11.0%; 95% CI, 3.4% to 18.7%); thus, the potential for efficient operation was greater with the Targis than the Prostatron antenna. CONCLUSIONS: The Targis microwave antenna was found to provide a more targeted heating pattern and have a capacity for more efficient thermal energy delivery than the Prostatron antenna. These differences observed in vitro could potentially translate into clinical advantages in vivo, such as improved tolerability of microwave treatment, reduced risk of complications, greater thermoablative efficacy, and scalability.

Diathermy↗

Optimization of wide-area ATM and local-area ethernet/FDDI network configurations for high-speed telemedicine communications employing NASA's ACTS.

A high data rate terrestrial and satellite network was implemented to transfer medical images and data. This article describes the a optimization of the workstations and switching equipment incorporated into the network. Topics discussed in this article include tuning of the network software, the configuration of the Sun Microsystems workstations, the FORE Systems asynchronous transfer mode switches, as well as the throughput results of two telemedicine experiments undertaken by Mayo's physician staff. The technical staff was successful in achieving the data throughput needed by the telemedicine software; particularly important was the proper determination of peak throughput and TCP window sizes to ensure optimum use of the resources available on the Sun Microsystems and Hewlett Packard workstations.

Angiography↗