PubMed Health⌕ Search

Biomedical subjects

J Lötjönen

Publications and source records attributed to J Lötjönen.

6 recordsLinked to original sources

Statistical shape model of atria, ventricles and epicardium from short- and long-axis MR images.

We describe a new 3-D statistical shape model of the heart consisting of atria, ventricles and epicardium. The model was constructed by combining information on standard short- and long-axis cardiac MR images. In the model, the variability of the shape was modeled with PCA- and ICA-based shape models as well as with non-parametric landmark probability distributions and a probabilistic atlas. The statistical atlas was built from 25 healthy subjects. The shape model was evaluated by applying it to image segmentation. The probabilistic atlas was found to be superior to the other shape models (P < 0.001) in this study.

Adult↗

The effect of geometric and topologic differences in boundary element models on magnetocardiographic localization accuracy.

This study was performed to evaluate the changes in magnetocardiographic (MCG) source localization results when the geometry and the topology of the volume conductor model were altered. Boundary element volume conductor models of three patients were first constructed. These so-called reference torso models were then manipulated to mimic various sources of error in the measurement and analysis procedures. Next, equivalent current dipole localizations were calculated from simulated and measured multichannel MCG data. The localizations obtained with the reference models were regarded as the "gold standard." The effect of each modification was investigated by calculating three-dimensional distances from the gold standard localizations to the locations obtained with the modified model. The results show that the effect of the lungs and the intra-ventricular blood masses is significant for deep source locations and, therefore, the torso model should preferably contain internal inhomogeneities. However, superficial sources could be localized within a few millimeters even with nonindividual, so called standard torso models. In addition, the torso model should extend long enough in the pelvic region, and the positions of the lungs and the ventricles inside the model should be known in order to obtain accurate localizations.

Biomedical Engineering↗

Model extraction from magnetic resonance volume data using the deformable pyramid.

A general framework for automatic model extraction from magnetic resonance (MR) images is described. The framework is based on a two-stage algorithm. In the first stage, a geometrical and topological multiresolution prior model is constructed. It is based on a pyramid of graphs. In the second stage, a matching algorithm is described. This algorithm is used to deform the prior pyramid in a constrained manner. The topological and the main geometrical properties of the model are preserved, and at the same time, the model adapts itself to the input data. We show that it performs a fast and robust model extraction from image data containing unstructured information and noise. The efficiency of the deformable pyramid is illustrated on a synthetic image. Several examples of the method applied to MR volumes are also represented.

Algorithms↗

Bioelectromagnetic localization of a pacing catheter in the heart.

The accuracy of localizing source currents within the human heart by non-invasive magneto- and electrocardiographic methods was investigated in 10 patients. A non-magnetic stimulation catheter inside the heart served as a reference current source. Biplane fluoroscopic imaging with lead ball markers was used to record the catheter position. Simultaneous multichannel magnetocardiographic (MCG) and body surface potential mapping (BSPM) recordings were performed during catheter pacing. Equivalent current dipole localizations were computed from MCG and BSPM data, employing standard and patient-specific boundary element torso models. Using individual models with the lungs included, the average MCG localization error was 7+/-3 mm, whereas the average BSPM localization error was 25+/-4 mm. In the simplified case of a single homogeneous standard torso model, an average error of 9+/-3 mm was obtained from MCG recordings. The MCG localization accuracies obtained in this study imply that the capability of multichannel MCG to locate dipolar sources is sufficient for clinical purposes, even without constructing individual torso models from x-ray or from magnetic resonance images.

Body Surface Potential Mapping↗

Reconstruction of 3-D geometry using 2-D profiles and a geometric prior model.

A method has been developed to reconstruct three-dimensional (3-D) surfaces from two-dimensional (2-D) projection data. It is used to produce individualized boundary element models, consisting of thorax and lung surfaces, for electro- and magnetocardiographic inverse problems. Two orthogonal projections are utilized. A geometrical prior model, built using segmented magnetic resonance images, is deformed according to profiles segmented from projection images. In our method, virtual X-ray images of the prior model are first constructed by simulating real X-ray imaging. The 2-D profiles of the model are segmented from the projections and elastically matched with the profiles segmented from patient data. The displacement vectors produced by the elastic 2-D matching are back projected onto the 3-D surface of the prior model. Finally, the model is deformed, using the back-projected vectors. Two different deformation methods are proposed. The accuracy of the method is validated by a simulation. The average reconstruction error of a thorax and lungs was 1.22 voxels, corresponding to about 5 mm.

Diagnostic Imaging↗

Nonfluoroscopic localization of an amagnetic stimulation catheter by multichannel magnetocardiography.

This study was performed to: (1) evaluate the accuracy of noninvasive magnetocardiographic (MCG) localization of an amagnetic stimulation catheter; (2) validate the feasibility of this multipurpose catheter; and (3) study the characteristics of cardiac evoked fields. A stimulation catheter specially designed to produce no magnetic disturbances was inserted into the heart of five patients after routine electrophysiological studies. The catheter position was documented on biplane cine x-ray images. MCG signals were then recorded in a magnetically shielded room during cardiac pacing. Noninvasive localization of the catheter's tip and stimulated depolarization was computed from measured MCG data using a moving equivalent current-dipole source in patient-specific boundary element torso models. In all five patients, the MCG localizations were anatomically in good agreement with the catheter positions defined from the x-ray images. The mean distance between the position of the tip of the catheter defined from x-ray fluoroscopy and the MCG localization was 11 +/- 4 mm. The mean three-dimensional difference between the MCG localization at the peak stimulus and the MCG localization, during the ventricular evoked response about 3 ms later, was 4 +/- 1 mm calculated from signal-averaged data. The 95% confidence interval of beat-to-beat localization of the tip of the stimulation catheter from ten consecutive beats in the patients was 4 +/- 2 mm. The propagation velocity of the equivalent current dipole between 5 and 10 ms after the peak stimulus was 0.9 +/- 0.2 m/s. The results show that the use of the amagnetic catheter is technically feasible and reliable in clinical studies. The accurate three-dimensional localization of this multipurpose catheter by multichannel MCG suggests that the method could be developed toward a useful clinical tool during electrophysiological studies.

Adult↗