PubMed Health⌕ Search

Biomedical subjects

J Larky

Publications and source records attributed to J Larky.

2 recordsLinked to original sources

Consonant perception by users of Nucleus and Clarion multichannel cochlear implants.

A study was carried out to compare the consonant perceptions of five Nucleus multichannel cochlear implant users, five Clarion-CIS users, and four Clarion-CA users. All subjects were administered the Iowa Medical Consonant Recognition Test in the auditory-only condition. The groups averaged approximately 1 year of implant use at the time of testing, and the average age at implantation was 47 years for the Nucleus users, 60 years for the Clarion-CIS users, and 56 years for the Clarion-CA users. The percent-corrected scores for all three devices were variable and ranged from 34% to 84%, with each group averaging about 50% correct consonant recognition. Consonant feature information transmission was calculated for five features: manner of articulation, nasality, place of articulation, duration, and voicing. The highest information transmission in the Nucleus group was for the features of duration (71%), nasality (60%), and voicing (57%), which agrees with previous studies. The Clarion-CIS group had the highest information transmission for duration, place of articulation, manner of articulation, and nasality (50%, 29%, 28%, and 27%). The Clarion-CA group had the highest information transmission for the features voicing, place of articulation, and duration (41%, 40%, and 37%). This study indicates that the Clarion device may carry some acoustic information related to place of articulation, a feature that has not been found to be encoded well by other multichannel cochlear implants.

Adult↗

Factors affecting auditory performance of postlinguistically deaf adults using cochlear implants.

A model of auditory performance and a model of ganglion cell survival in postlinguistically deafened adult cochlear implant users are suggested to describe the effects of aetiology, duration of deafness, age at implantation, age at onset of deafness, and duration of implant use. The models were compared with published data and a composite data set including 808 implant users. Qualitative agreement with the model of auditory performance was found. Duration of deafness had a strong negative effect on performance. Age at implantation had a slight negative effect on performance, increasing after age 60 years. Age at onset of deafness had little effect on performance up to age 60. Duration of implant use had a positive effect on performance. Aetiology had a relatively weak effect on performance.

Adolescent↗