Long-term persistence of hepatitis G virus in immunocompetent patients.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to J Lerable.
Explore the source record for details and available documents.
BACKGROUND: Passive immunotherapy in human immunodeficiency virus (HIV) infection is based on transfusions of plasma that is rich in HIV antibodies. STUDY DESIGN AND METHODS: To verify whether the clearance of transfused antibodies will maintain an elevated titer of specific antibodies between biweekly transfusions of plasma, the titers of anti-HIV-1 in plasma and in transfusion recipients were measured. Samples from 12 recipients were analyzed by automated scanning of Western blot, before transfusion and at Days 2, 7, and 14 after transfusion. RESULTS: The p24 antibody became detectable or higher than the baseline after transfusion and remained detectable until the second transfusion. Anti-p24 titers were variable and dependent on the antibody titer of the transfused plasma and the baseline p24 antigen titer. CONCLUSION: Biweekly transfusion of plasma with a high anti-HIV titer maintains a high anti-p24 titer between transfusions in AIDS patients treated with passive immunotherapy.
We studied the prognostic value on the decrease of CD4 lymphocyte count of anti-p24 antibody (ab) titer and compared this value with that of polyclonal and monoclonal p24 (ag) titer before and after immune complex dissociation (ICD); 53 human immunodeficiency virus (HIV)-infected patients having CD4+ counts above 400/mm3 when first examined were followed up over a 3-year period including at least four visits; HIV disease progressors (n = 18) were defined as having CD4+ counts below 200/mm3 and non-progressors (n = 35) as having CD4+ counts still above 400/mm3 at the end of follow-up. Sera were collected at each visit and assayed for p24 ag with and without ICD and for anti-p24 ab titer. The mean anti-p24 ab titer of progressors and of non-progressors at entry was significantly different. A threshold of anti-p24 ab titer indicating a HIV progression was determined at 1/300. The proportion of individuals with an anti-p24 ab titer lower than 1/300 at least once during the study period was 34% in non-progressors and 94% in progressors. The difference between progressors and non-progressors at entry was significant with monoclonal p24 ag without ICD and more significant with monoclonal p24 ag after ICD. The marker having the highest predictive value was the anti-p24 ab titer, then monoclonal p24 ag with ICD, then polyclonal p24 ag with ICD. Anti-p24 ab is an earlier and stronger marker of the decrease of CD4 lymphocyte count than p24 ag even after ICD.
BACKGROUND: B19 parvovirus (B19) may be transmitted iatrogenically by blood, and its prevalence in blood donations is estimated at 1 in 3,300 to 1 in 50,000. As a large number of blood donations make up the plasma pools used to produce plasma derivatives, even a virus as rare as B19 in a population of blood donors may result in the frequent contamination of plasma batches. The percentage of albumin batches containing B19 DNA has never been determined. STUDY DESIGN AND METHODS: The presence of B19 DNA was investigated by a polymerase chain reaction assay (with a primer pair in the VP1 region) in a total of 12 and 17 batches of 4- and 20-percent albumin, respectively, from two different manufacturers. RESULTS: No B19 DNA was detected in the batches tested. CONCLUSION: The current fractionation process used to obtain these albumin preparations is seen to allow the efficient degradation and/or elimination of B19.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
With the aim of improving the biological diagnosis of hepatocellular carcinoma (HCC), alpha-fetoprotein (AFP), des-gamma-carboxyprothrombin (DCP) and factor V levels were assayed in 119 patients with HCC and 60 cirrhotic patients without HCC. Among the patients with HCC, increased levels of AFP (greater than 300 ng/ml) and of DCP (greater than 15 mU/ml) were observed in 36% and 69% of the cases, respectively. None of the 60 patients without HCC had increased AFP, and one had abnormal DCP; in this patient, DCP level returned to normal value after vitamin K1 injection. No significant correlation was found between increased AFP and DCP, thus indicating that the two tests complement each other for the diagnosis. A factor V level higher than expected from the reduced prothrombin time test of the patient was detected in 50% of patients with HCC and only 7% of those without HCC. No correlation was found between increased factor V and abnormal AFP or DCP. The thrombin time, fibrinogen activity to antigen ratio, and polymerization index failed to differentiate between cirrhosis and HCC. We conclude that AFP, DCP and factor V may give complementary informations in the diagnosis of HCC, one of these markers at least being positive in 88% of the patients.
Explore the source record for details and available documents.
15 rabbits and 6 dogs were injected with a mixture of thrombin and heparin. Increasing amounts of thrombin, and various ratio of thrombin in relation to heparin, were used. It was found that huge amounts of thrombin could be perfused, under the protection of heparin, without untoward effects. But the high amount of thrombin needed to obtain a 50% reduction of the circulating AT III required a corresponding high amount of protective heparin. Since the secondary injection of protamin sulphate (after the end of the perfusion with the thrombin-heparin mixture) was precipitating the DIC syndrome, such attempts to decrease AT III in man are not feasible.
A purification method for C1 esterase is described. The final product significantly improved the sensitivity and the specificity of the enzymatic measurement of its plasma inhibitor C1-INH or alpha 2-neuraminoglycoprotein (alpha 2-NGP) by esterolysis of a synthetic substrate N-acetyl-L-tyrosine ethyl ester (ALTEe). A comparative study was done between the chromatographed C1 esterase and the native serum euglobulins: qualitative and quantitative determination of the serum contaminants, enzymatic activity measurement of C1-INH in normal subjects and in patients suffering from hereditary angioneurotic oedema (OANH) as well as in therapeutical C1-inhibitor concentrates.
Explore the source record for details and available documents.
Explore the source record for details and available documents.