PubMed Health⌕ Search

Biomedical subjects

J Lloréns

Publications and source records attributed to J Lloréns.

8 recordsLinked to original sources

[The use of high-frequency jet ventilation for ventilatory support in an extreme case].

We report the case of a 27-year old man given a left lateral thoracotomy for emergency repair of the aortic isthmus, which had partially ruptured as a consequence of chest trauma. The patient also suffered serious trauma to the right lung, such that selective ventilation of that lung had to be applied with the left lung collapsed to allow the surgeon access to the descending aorta. Rapid decrease in SpO2 occurred, with excessively high airway pressures, requiring reinstatement of conventional ventilation of both lungs and interruption of surgery. Conventional ventilation was then replaced by high frequency jet ventilation to both lungs. That technique, combined with intermittent inflation of the left lung (inclined), provided sufficient oxygen as well as a wide and sufficiently immobile surgical field.

Adult↗

[Cesarean section on a full-term parturient with convulsive crises].

A 34-years-old woman in her 35th week of pregnancy experienced epileptic seizures and underwent emergency cesarean delivery of a healthy boy under general anesthesia. The patient had no history of epilepsy and the seizures were later attributed to an intracerebral cavernous angioma. She received treatment with phenytoin and was asymptomatic 3 months later. Although seizures unrelated to preeclampsia or eclampsia in pregnancy are rare, differential diagnosis must determine the etiology of the crisis.

Adult↗

[Application of high frequency jet ventilation during microsurgery of the larynx under suspending laryngoscopy].

OBJECTIVES: This study describes the results obtained with high frequency jet ventilation (HFJV) in 19 patients who underwent laryngeal microsurgery under suspending laryngoscopy. MATERIAL AND METHODS: After premedication and anesthetic induction with propofol (Diprivan R, ICI-Farma), we performed an endotracheal intubation (28F tube) under succinyl-choline facilitation. Conventional ventilation was started at a rate of 14-16 cpm with a minute volume of 8-10 l, and a FiO2 of 0.4 (air-oxygen). The endotracheal tube was replaced by an insufflation catheter of 2 mm internal diameter and HFJV was initiated at a rate of 100 cpm, inspiratory time equal to the 33% of the total cycle, generator pressure of 2.5-3.6 kg/cm2, and similar FiO2. We used an Ergojet CVT (Temel SA) respirator that allowed continuous monitoring of the injector released volume during each cycle (Vjet) as well as the air way pressure. Anesthesia was maintained with continuous propofol perfusion. RESULTS: During HFJV there were no significant hemodynamic alterations and surgeons considered that the condition of the surgical field was excellent. Air way pressure was maintained at low levels in all cases, although brief hypertensive episodes occurred during laryngeal manipulation. Oxygenation was satisfactory in all except one patient with chronic obstructive pulmonary disease. Conventional ventilation and HFJV did not induce significant differences in alveolar ventilation nor in PaCO2. However, during HFJV oxygenation and ventilatory levels suffered a high degree of interindividual variability. This phenomenon could be due to the existence of variable degrees of gas reflux during insufflation. CONCLUSIONS: We conclude that HFJV is a very useful technique for anesthesia in laryngeal microsurgery. However, an appropriate monitoring of ventilatory dynamics and a detailed knowledge of the influences of patient's characteristics on HFJV are required.

Adult↗

[Conditioning factors in intrapulmonary gas trapping during controlled mechanic ventilation in anesthesia].

OBJECTIVES: To establish a relation between intrapulmonary gas trapping (Vat) generated by controlled ventilation during anesthesia and the factors that are likely to condition such trapping: flow volume (VT), expiratory time (te), compliance (C), resistance (R) and a time constant in either the anesthetized patient (tau) or under conditions of forced expiration in respiratory function testing (TC 25/50). PATIENTS AND METHODS: Thirty patients undergoing surgery with general anesthesia were ventilated following 3 different patterns with te of 2.66, 2 and 1.33 sec, respectively. We measured Vat, C, R and tau for each pattern. Correlation coefficients were figured and line regressions were drawn for Vat and the conditioning factors. We also figured the correlation between mean Vat and calculated Vat based on TC 25/50. RESULTS: Intrapulmonary gas trapping occurred in 93% of patients and increased significantly as te decreased. Correlations between Vat and the factors were as follows: r=0.76 for tau, r=0.62 for C, r=0.62 for R, r= 0.13 for VT and r2 = -0.92 for te/tau. The correlation coefficient of tau and TC 25/50 was 0.92. CONCLUSIONS: The results obtained indicate that Vat depends above all on the ratio of te to tau and that trapping can be prevented by applying a te that is greater than 3 tau.

Adolescent↗