The surgical diathermy: principles of operation and safe use.

An understanding of the principles of operation and hazards of the surgical diathermy is necessary for the safety of the anaesthetized patient. The surgical diathermy performs its function by the application of high density radio frequency current which can be used to cut or coagulate tissue. Its improper use can result in electrical burns and even electrocution. The principles underlying its safe use are outlined, and detailed recommendations are made to ensure the patient's safety.

Disposable Equipment↗

Measurement errors in pneumotachography due to pressure transducer design.

When pneumotachography is used during intermittent positive pressure ventilation (IPPV), the design of some differential pressure transducers can cause measurement errors. These errors may be avoided by using differential pressure transducers which have small, equal chambers free from temperature sensitive electrical elements. Few of the transducers which are sensitive enough for clinical use fulfil these requirements.

Diagnostic Errors↗

Errors in pneumotachography with intermittent positive pressure ventilation.

Instrument errors that can occur when pneumotachography is used during Intermittedt Positive Pressure Ventilation (IPPV) have been described previously (Kafer 1973). Our efforts to eliminate these errors led to the discovery of further inaccuracies, which appear to be due to the design of the differential pressure transducers used with pneumotachograph head. A system was used in which a sine-wave pump delivered a constant tidal volume to a dummy lung, the tidal volume being measured by means of a pneumotachograph. Using Grass, Statham and Devices differential pressure transducers, the volume recorded as leaving the dummy lung was consistently greater than that recorded as entering, and changing the pneumatic polarity of the differential pressure transducer produced large differences in the recorded volume. In some cases the error was greater than the volume being measured. There would seem to be several causes of such errors. The Sanborn 270 differential pressure transducer and the Greer micromanometer appeared to be free of these artifacts. The results of this study throw into doubt much previously published work using pneumotachography during IPPV.