Histologic evaluation of threaded HA-coated root-form implants after 3.5 to 11 years of function: a report of three cases.

This article presents a histologic evaluation of three hydroxyapatite (HA)-coated root-form implants retrieved from humans after being in function for 3.5 to 11 years. If the coronal portion, where bone loss was observed clinically and radiographically, is excluded, all implants appeared to be well osseointegrated, with intimate contact between the surrounding bone and the coating. There was no sign of resorption or dissolution of the HA coating. The coating had a uniform thickness (50 microm) equal to the thickness originally provided by the manufacturer In the few areas where there was no bone contact, the HA coating appeared to line the implant with no sign of dissolution. The few detached particles had tight contact with the bone, demonstrating the biocompatibility of the HA. The observations from the three reported cases suggest that the HA coating of dental implants may not be susceptible to resorption or dissolution under long-term function.

Adult↗

Study of a needleless intermittent intravenous-access system for peripheral infusions: analysis of staff, patient, and institutional outcomes.

OBJECTIVE: To assess the effect on staff- and patient-related complications of a needleless intermittent intravenous access system with a reflux valve for peripheral infusions. DESIGN: A 6-month cross-over clinical trial (phase I, 13 weeks; phase II, 12 weeks) of a needleless intermittent intravenous access system (NL; study device) compared to a conventional heparin-lock system (CHL, control device) was performed during 1991 on 16 medical and surgical units. A random selection of patients was assessed for local intravenous-site complications; all patients were assessed for the development of nosocomial bacteremia and device-related complications. Staff were assessed for percutaneous injuries and participated in completion of product evaluations. A cost analysis of the study compared to the control device was performed. SETTING: A 1,100-bed, teaching, referral medical center. PATIENTS AND STAFF PARTICIPANTS: 594 patients during 602 patient admissions, comprising a random sample of all patients with a study or control device inserted within a previous 24-hour period on study and control units, were assessed for local complications. The 16 units included adult inpatient general medicine, surgical, and subspecialty units. Pediatrics, obstetrics-gynecology, and intensive-care units were excluded. All patients on study and control units were assessed for development of nosocomial bacteremia and device-related complications. All staff who utilized, manipulated, or may have been exposed to sharps on study and control units were assessed for percutaneous injuries. Nursing staff completed product evaluations. INTERVENTION: The study device, a needleless intermittent intravenous access system with a reflux valve, was compared to the control device, a conventional heparin lock, for peripheral infusions. RESULTS: During the study, 35 percutaneous injuries were reported. Eight injuries were CHL-related; no NL-related injuries were reported (P=.007). An evaluation of 602 patient admissions, 1,134 intermittent access devices, and 2,268 observed indwelling device days demonstrated more pain at the insertion site for CHL than NL; however, no differences in objective signs of phlebitis were noted. Of 773 episodes of positive blood cultures on study and control units, 6 (0.8%) were device-related (assessed by blinded investigator), with no difference between NL and CHL. Complications, including difficulty with infusion (P<.001) and disconnection of intravenous tubing from device (P<.001), were reported more frequently with CHL than with NL. Of nursing staff responding to a product evaluation survey, 95.2% preferred the study over control device. The projected annual incremental cost to our institution for hospitalwide implementation of NL for intermittent access for peripheral infusions was estimated at $82,845, or $230 per 1,000 patient days. CONCLUSIONS: A needleless intermittent intravenous access system with a reflux valve for peripheral infusions is effective in reducing percutaneous injuries to staff and is not associated with an increase in either insertion-site complications or nosocomial bacteremia. Institutions should consider these data, available institutional resources, and institution-specific data regarding the frequency and risk of intermittent access-device-related injuries and other types of sharps injuries in their staff when selecting the above or other safety devices.

Anticoagulants↗

Implant diameter and bone density: effect on initial stability and pull-out resistance.

It is well known that the standard diameter dental implant so often utilized is often inadequate in patients with poor bone quality or quantity, and larger diameter implants have been utilized to overcome this deficiency. The objective of this study was to compare the pull-out resistance of small and large diameter (3.25- and 4.5-mm) dental implants and the relationship of these implants to bone density. Two groups of implants, consisting of 18 implants of each diameter, were placed in the mandibles of five embalmed humans. The bone mineral density of the area surrounding the implant site in the coronal cross section was measured by quantitative computed tomography (QCT). Initial implant stability was tested with a periodontium diagnostic device and pull-out resistance was tested with a mechanical testing system. Results showed the same initial stability for the two implants. The maximum pull-out force required for the large diameter implants was 15% greater than that required for the small diameter implants, although given the small number of samples, this difference was not statistically significant. There were significant positive correlations between the pull-out resistance and the bone density for both the large and small diameter implants (p < 0.05, p < 0.01). We conclude that larger diameter implants appear to have advantages over smaller ones; however, more extensive testing is needed to determine quantitatively the increased load-carrying capacity.

Aged↗

The experimental verification of the efficacy of finite element modeling to dental implant systems.

In vitro experimental data of angular displacement vs. applied force were obtained on a fully osseointegrated pair of endosseous implants in a mandible of a macaca mulatta monkey. These data are compared with calculated displacement data for a given force from a three-dimensional finite element model reproducing the geometric structure of a portion of the mandible holding the implants. The displacements show agreement over a range of forces in the elastic region within 3%. The FE model yields a full description of the bending of the implant and the distribution of the stress in the bone surrounding the implants.

Alveolar Process↗

[Peri-implant defects. Surgical treatment].

The Authors present a clinical case of vertical bone loss in the peri-implant tissue, surgically treated. The adopted protocol led to the complete clinical and radiological recovery six months after surgery.

Alveolar Bone Loss↗

Suspension mechanism of subperiosteal implants in baboons.

It has been noted that overloading of an implant can lead to the premature loss of implants (Jones et al., 1979; Travis and Jones, 1986). An understanding of the mechanism by which subperiosteal implants support masticatory loads could lead to appropriate design changes for best utilization of this mechanism and thus increase the predictability of subperiosteal implants (James, 1983). This study attempts to analyze the suspension mechanism in implants recovered from a baboon after 10 years' use.

Animals↗

Histologic evaluation of hydroxyapatite-coated root-form implant retrieved after 7 years in function: a case report.

This case report presents a clinical, radiographic, and histologic evaluation of 2 non-adjacent, hydroxyapatite-coated, root-form implants retrieved from the maxillary canine area of a patient after 7 years in function. Clinical examination revealed immobile implants with no sign of pathosis. Radiographic examination indicated close proximity of the bone to the implant surface without evidence of radiolucency. Histologically, the 2 implants appeared to be well integrated with the surrounding bone; 84% of the surface of the first implant and 79% of the surface of the second implant had close bone apposition at the interface. There was no evidence of dissolution of the hydroxyapatite coating. The bone appeared to be in immediate contact with the coating. These observations suggest that a particular hydroxyapatite coating on root-form implants can resist degradation during long-term function.

Aged↗

Histologic evaluation of a 9-year-old hydroxyapatite-coated cylindric implant placed in conjunction with a subantral augmentation procedure: a case report.

The histologic examination of dental implants retrieved from humans provides a unique opportunity to evaluate the bone-implant interface. This case report presents a clinical, radiographic, and histologic evaluation of a cylindrical hydroxyapatite- (HA) coated implant retrieved from the posterior maxillary area of a patient after 9 years after placement. The implant had been placed in conjunction with a subantral augmentation procedure with HA as the graft material. Clinical examination revealed an immobile implant with no sign of pathosis. Radiographic examination indicated close proximity of the bone to the implant surface without evidence of radiolucency. Histologically, because of tissue destruction during implant retrieval, only the apical portion of the implant was available for examination under light microscopy, and it appeared to be integrated with the surrounding bone; 45.9% of the surface of the implant had close bone apposition at the interface. There was no evidence of dissolution of the HA coating and the bone appeared to be in immediate contact with the coating. Residual graft particles were present and in close proximity with the implant surface. These observations suggest that the subantral augmentation procedure performed simultaneously with the placement of an HA-coated implant with HA as the graft material apparently resulted in osseointegration between the implant and the surrounding bone. The implant was maintained without complication for 9 years.

Alveolar Ridge Augmentation↗