Calf blood flow and posture: Doppler ultrasound calibrated by plethysmography.

A procedure was developed that enables measurement of rapid variations in calf blood flow during voluntary rhythmic contraction of the calf muscles in supine, sitting, and standing positions. During the exercise, maximum blood velocity is measured by Doppler ultrasound equipment in the popliteal artery. The Doppler signals are calibrated by plethysmography to enable calculation of blood flow during exercise in ml.100 ml-1.min-1. Knowledge of the cross-sectional area of the vessel and the angle of insonation is not required in this procedure. Evaluation of the calibration method with 10 healthy volunteers showed that for each subject a new calibration was necessary after a change in posture; the relationship between the blood flow and the maximum Doppler frequency averaged over one heart cycle was linear for each calibration.

Blood Flow Velocity

Calf blood flow and posture: Doppler ultrasound measurements during and after exercise.

To investigate the joint effects of body posture and calf muscle pump, the calf blood flow of eight healthy volunteers was measured with pulsed Doppler equipment during and after 3 min of rhythmic exercise on a calf ergometer in the supine, sitting, and standing postures. Muscle contractions seriously impeded calf blood flow. Consequently, blood flow occurred mainly between contractions and reached a plateau that lasted at least the final 100 s of each exercise series. After exercise the blood flow decreased much faster in the sitting and standing postures than in the supine posture. There was no difference in blood flow between various postures during the same submaximal exercise. However, subjects in the standing posture were able to perform exercise with a higher load than in the supine posture, and blood flow in the standing posture could become twice as high as in the supine posture. We conclude that calf blood flow is regulated according to needs; available perfusion pressure determined maximal blood flow and exercise; and compared with the supine posture, the standing posture and calf muscle pump increase the perfusion pressure.

Adult

Multipurpose ergometer for static and dynamic exercise of the calf muscles.

A calf ergometer is presented that can be used for both static and dynamic exercise in supine, sitting or standing position. During exercise each foot is fixed firmly to a pedal. During dynamic exercise the foot pedal can rotate through an angle which can be varied from 5 to 30 degrees. External work is performed only during plantar flexion. The amount of work is determined by the moment imposed to the pedal by a constant force spring and can be calculated from electrical signals that represent the angle of rotation and the moment exerted to the pedal. During static exercise the foot pedal is secured so that it cannot move.

Equipment Design

The difference in blood pressure between upper arm and finger during physical exercise.

A new apparatus which measures the blood pressure in the finger continuously and yet not invasively was tested for its usefulness during exercise. It was compared with upper arm measurements in 23 volunteers during prolonged bicycle ergometry. Simultaneously, a pulse plethysmogram was recorded from another finger of the same arm, whereas in six additional volunteers Doppler measurements were carried out on the radial artery. The results show that finger systolic pressure ceased to rise at about 40% of maximal exercise; the difference with the continuously rising systolic pressure in the upper arm becoming significant at 140 W. At the same time the amplitude of the finger plethysmogram became significantly higher than its initial value, indicating distinct cutaneous vasodilation, whereas the volunteers also became hot and started to perspire. However, the radial artery 'flow', deduced from the Doppler measurements, did not change significantly during exercise. It increased sharply and markedly in the cooling down period. Simultaneously with this increase in flow, HR and both systolic blood pressures fell drastically whereas the plethysmographic amplitude remained about stable at its raised level. The results fit in with the idea that a compromise is achieved between the need for muscle activity and the need for temperature regulation. It is concluded that the Finapres functions well during exercise, but that the systolic pressure in the finger is not representative for its more central counterpart during cutaneous vasodilation. It is argued that opening up of AVAs may contribute to this pressure effect.

Adult

A continuous wave Doppler velocimeter for monitoring blood flow in the popliteal artery, compared with venous occlusion plethysmography of the calf.

A transcutaneous Doppler velocimeter has been used for monitoring changes in blood flow in the popliteal artery during and after exercise of the calf muscles on a calf-ergometer. The instrument and the positioning of the probe are described. The validity of the Doppler measurements has been assessed by comparing results after exercise and after 5 min arterial occlusion with venous occlusion plethysmography. For 10 healthy volunteers calibration lines were found which are curved. This can be ascribed partly to alinearity of the Doppler instrument and partly to changes of the diameter of the popliteal artery. Displacement of the probe with respect to the artery, which influences the measured velocity signal, can be detected and to a certain extent corrected by taking into account the intensity of the Doppler signal. The largest deviation of a data point from the corresponding calibration line varies for the ten subjects between 90 and 170 Hz in the high flow range (mean Doppler frequency around 1000 Hz) and between 20 and 60 Hz in the low flow range (mean Doppler frequency below 200 Hz).

Adult