PubMed Health⌕ Search

Biomedical subjects

J M Almendral

Publications and source records attributed to J M Almendral.

At least 37 records · Page 2Linked to original sources

Multigene families in African swine fever virus: family 360.

A group of cross-hybridizing DNA segments contained within the restriction fragments RK', RL, RJ, and RD' of African swine fever virus DNA were mapped and sequenced. Analysis of these sequences revealed the presence of a family of homologous open reading frames in regions close to the DNA ends. The whole family is composed of six open reading frames with an average length of 360 coding triplets (multigene family 360), four of which are located in the left part of the genome and two of which are in the right terminal EcoRI fragment. In close proximity to the right terminal inverted repeat, we found an additional small open reading frame which was homologous to the 5'-terminal portion of the other open reading frames, suggesting that most of that open reading frame has been deleted. These repeated sequences account for the previously described inverted internal repetitions (J.M. Sogo, J.M. Almendral, A. Talavera, and E. Viñuela, Virology 133:271-275, 1984). Most of the genes of multigene family 360 are transcribed in African swine fever virus-infected cells. A comparison of the predicted protein sequences of family 360 indicated that several residues are conserved, suggesting that an overall structure is maintained for every member of the family. The transcription direction of each open reading frame, as well as the evolutionary relationships among the genes, suggests that the family originated by gene duplication and translocation of sequences between the DNA ends.

Amino Acid Sequence↗

Procainamide-induced slowing of ventricular tachycardia with insights from analysis of resetting response patterns.

To investigate the mechanism of slowing of the rate of ventricular tachycardias (VTs) by procainamide, resetting response patterns were characterized in 24 VTs in 22 patients. All patients had coronary artery disease and inducible sustained VT during procainamide therapy. Only tachycardias with the same surface QRS morphology before and after procainamide were studied: all were slowed by procainamide. The mean cycle length was 292 +/- 61 ms before and 374 +/- 61 ms after procainamide (p less than 0.05). The mean effective refractory period, measured at the right ventricle, was 241 +/- 21 ms before and 261 +/- 24 ms after procainamide (p less than 0.05). During procainamide therapy, single and double extrastimuli were delivered during VT and resetting response patterns identified. Patterns were characterized as flat, increasing or flat plus increasing. Resetting was seen in 17 (71%) of these VTs and resetting response patterns were identified in 16 (94%) of these. The resetting response pattern was flat in 7, flat plus increasing in 5 and increasing in 4. The finding of some flat portion at the end of resetting response patterns in 12 VTs after procainamide indicates that the reentrant impulse conducts through fully recovered tissue within the circuit. It suggests that procainamide slowed these VTs by slowing conduction velocity in fully recovered tissue due to sodium channel blockade and not by prolongation of action potentials and refractory periods.

Cardiac Pacing, Artificial↗

Expression, cloning and cDNA sequence of a fibroblast serum-regulated gene encoding a putative actin-associated protein (p27).

A cDNA clone for a basic putative actin microfilament-associated protein, p27, highly induced in serum-stimulated NIH 3T3 cells, has been isolated by polyclonal antibodies and sequenced. p27 mRNA is a 1.2-kb molecule which is very low in resting NIH 3T3 cells but can be induced at least 100 times after 8 h of fetal calf serum stimulation. In contrast to other inducible mRNAs, p27 mRNA is stable, and its levels can be superinduced by cycloheximide mainly by prolonging transcription. The lack of expression of this messenger in mouse tissues, as well as in all cell lines so far tested, suggests that p27 may be an fibroblast-specific protein. One major open reading frame found in p27 cDNA codes for a 201 amino acid polypeptide not related to any previously described actin-binding protein. Interestingly, it shows alternative hydrophilic and hydrophobic domains of amino acids symmetrically arranged from the middle of the protein. The coordinate induction of p27 and actin mRNAs suggest that p27 may be involved in the cytoskeletal rearrangements induced early in cell growth and proliferation.

Amino Acid Sequence↗

Variable and constant regions in African swine fever virus DNA.

An analysis of the SalI restriction pattern of African swine fever virus DNA showed that the SalI recognition sites did not change after more than 100 virus passages in porcine macrophages. The virus strain BA71V, obtained from the virus isolate BA71 by adaptation to grow in VERO cells, differed from the nonadapted virus in two deletions with a length of 2.5 and 7 kb located close to the DNA ends. A restriction analysis of several virus clones obtained from a naturally infected pig revealed length heterogeneity in both variable regions. A comparison of SalI restriction maps from 23 African swine fever virus field isolates (8 African, 11 European, and 4 American) has shown that the virus genome consists of a central region with a constant length of about 125 kb and two variable regions located close to the DNA ends with a length of 38-47 kb for the left DNA end, and 13-16 kb for the right DNA end. The total length of ASF virus DNA varied between 178 (BA71) and 189 (MOZ64) kb. The 23 African swine fever virus isolates were classified into five groups, according to the arrangement of the SalI sites in the central region. Four groups contained only African isolates, whereas all the European and American isolates belonged to the same group. This distribution of isolates suggests that all non-African virus field isolates have a common origin.

Africa↗

Coupling intervals of ventricular extrastimuli causing resetting of sustained ventricular tachycardia secondary to coronary artery disease: relation to subsequent termination.

Single and double ventricular extrastimuli (VE) delivered during sustained, uniform ventricular tachycardia (VT) are able to reset or terminate the tachycardia. The relation between the coupling intervals of single and double VE resetting VT and those terminating it was examined in 80 uniform, morphologically distinct VT occurring in 52 patients. Of the 80 tachycardias receiving single VE, 41 were reset and 8 terminated. The corrected coupling interval of single VE first causing resetting was 0.81 +/- 0.08 compared with 0.66 +/- 0.06 for termination (p less than 0.001). Forty-two tachycardias received double VE with 33 being reset and 13 terminating. The corrected coupling interval of double VE at which resetting was first seen was 0.86 +/- 0.08 compared with 0.73 +/- 0.05 for termination (p less than 0.001). If the longest corrected coupling interval causing resetting was greater than or equal to 0.75, then 7 of 34 tachycardias terminated with single VE and 13 of 31 terminated with double VE compared with only 1 of 46 terminating with single VE and 0 of 10 with double VE if resetting was not observed by a corrected coupling interval of 0.75 (p less than 0.01 and p less than 0.02, respectively). If the longest corrected coupling interval at which resetting occurred was greater than or equal to 0.75, the predictive value for VT termination was 21% with single VE and 42% with double VE compared with only 2% with single VE and none with double VE if resetting was not observed by this corrected coupling interval.(ABSTRACT TRUNCATED AT 250 WORDS)

Cardiac Pacing, Artificial↗

Complexity of the early genetic response to growth factors in mouse fibroblasts.

Genes whose expression is growth factor regulated are likely to be important components in the mechanisms controlling cell proliferation and differentiation. With the aim of identifying some of those genes, a lambda cDNA library was prepared with poly(A)+ RNA from quiescent NIH 3T3 cells stimulated with serum for 4 h in the presence of cycloheximide. Differential screening of approximately 200,000 recombinant phage plaques revealed 2,540 clones that cross hybridized preferentially with [32P]cDNA derived from RNA of stimulated cells rather than with cDNA derived from nonstimulated cells. Cross hybridization of these clones identified 82 independent sequences, including c-fos and c-myc. Seventy-one clones were further studied. Analysis of the changes in transcription and mRNA levels after serum stimulation demonstrated that the kinetics and extent of the induction vary dramatically between the different genes. Cycloheximide in all cases superinduced the mRNA levels by two mechanisms, inhibiting the shutoff of transcription and prolonging the half-lives of the mRNAs. Our results showed that induction of proliferation is accompanied by the onset of a complex genetic program.

Animals↗

Entrainment of ventricular tachycardia: explanation for surface electrocardiographic phenomena by analysis of electrograms recorded within the tachycardia circuit.

Transient entrainment was demonstrated during 59 pacing events in 18 episodes of sustained uniform ventricular tachycardia (VT) while recording electrograms from the site of origin of tachycardia (LE-SOO). During entrainment, the morphology of the initial component of the LE-SOO was identical to the morphology observed during the tachycardia in 13 VTs (group I), but in five VTs (group II), the initial component changed at a "critical" paced cycle length. The presence of the proposed surface electrocardiographic criteria for entrainment--fixed fusion and a first postpacing complex without fusion but occurring at the paced cycle length--were integrally dependent on the morphologic changes in the local presystolic electrogram. Fixed fusion of the surface electrocardiogram at one or more paced cycle lengths was detected during entrainment at 35 of 59 paced cycle lengths in 12 of 18 tachycardias, 10 of which were group I and two of which were group II VTs. Fixed fusion demonstrated by analysis of the LE-SOO was observed at one or more pacing cycle lengths in 17 of 18 VTs. In five tachycardias in which surface electrocardiographic fusion was not observed, fixed fusion was evident on analysis of the left ventricular LE-SOO during right ventricular pacing. The first postpacing interval, as measured at the surface electrocardiogram, was consistently equal to the paced cycle length in only one of 18 tachycardias and was greater than the VT cycle length in eight of 17 tachycardias. A pathway with a long conduction time was demonstrated during entrainment. However, in those 12 VTs in patients in whom pacing was performed at more than one cycle length and there was preservation of the LE-SOO morphology, the conduction time between the stimulus and presystolic electrogram remained constant. Thus, no evidence for "atrioventricular nodal-like" decremental conduction was observed over a wide range of pacing cycle lengths. We conclude that: (1) two of the previously proposed criteria for diagnosis of entrainment (fixed fusion on the surface electrocardiogram and a first postpacing interval equal to the paced cycle length) are overly restrictive criteria for definition of "entrainment" of VT, (2) analysis of endocardial recordings from the site of origin of tachycardia during attempted entrainment of VT is useful for documenting the presence of entrainment, and (3) such analysis provides a basis for the understanding of surface electrocardiographic phenomenon associated with entrainment.

Cardiac Pacing, Artificial↗

Resetting of ventricular tachycardia with electrocardiographic fusion: incidence and significance.

The incidence and significance of fusion of the QRS complex during resetting of sustained ventricular tachycardias (VTs) was determined in 53 VTs induced by programmed stimulation in 46 patients with prior myocardial infarction. All 53 VTs were reset with one or two extrastimuli delivered at the right ventricular apex (RVA); 29 (54.7%) demonstrated fusion of the VT QRS complex coincident with the extrastimulus resetting the VT. Activation time at the RVA during VT (measured from the onset of the VT QRS complex to the first rapid deflection of the RVA electrogram) was longer in VT reset with fusion compared with those without fusion (91 +/- 30 vs 33 +/- 32 msec; p less than .001). A right bundle branch block VT QRS morphology and a rightward and inferior axis were more common in VT reset with electrocardiographic (ECG) fusion. Additionally, the shortest return cycle following the extrastimulus resetting the VT was shorter in VT reset with ECG fusion compared with those without (327 +/- 66 vs 423 +/- 84 msec; p less than .001). Fusion of the endocardial electrogram recorded at the site of VT origin was noted in 11 of 15 VTs that were reset while a recording catheter was positioned at this site, including all eight VTs with evidence of surface ECG fusion and three of seven VTs without fusion. Seventeen VTs were reset from the right ventricular outflow tract as well as the RVA; eight demonstrated QRS fusion at both sites, five from the right ventricular outflow tract only, and four from neither site.(ABSTRACT TRUNCATED AT 250 WORDS)

Cardiac Pacing, Artificial↗

The resetting response of ventricular tachycardia to single and double extrastimuli: implications for an excitable gap.

UNLABELLED: To evaluate the influence of local tissue refractoriness and delay in intervening tissue on the ability of single ventricular extrastimuli to reset and characterize a resetting response pattern in ventricular tachycardia (VT), single ventricular extrastimuli were delivered during 81 VTs and double ventricular extrastimuli in 45 of the 81 VTs. Resetting of VT was recognized as a less than fully compensatory pause after stimulation and was seen in 43 of 81 VTs (53%) with single ventricular extrastimuli and 35 of 45 (78%) with double ventricular extrastimuli. Double ventricular extrastimuli reset 16 VTs not reset by single ventricular extrastimuli. The return cycle, the interval from the extrastimulus to the first VT beat after extrastimuli, has 1 of 3 distinct response patterns: flat, increasing, and flat plus increasing. In 19 VTs, resetting was seen with both single ventricular extrastimuli and double ventricular extrastimuli; 4 flat responses with single ventricular extrastimuli became flat plus increasing with double ventricular extrastimuli. All other patterns were unchanged. In the 19 VTs reset by both single and double ventricular extrastimuli, the estimate of both the total reset zone (94 +/- 36 vs 56 +/- 32 ms) and the flat portion of the reset zone (52 +/- 42 vs 42 +/- 28 ms) was significantly longer with double ventricular extrastimuli (p less than 0.001 and p less than 0.02, respectively). IN CONCLUSION: (1) when single ventricular extrastimuli failed to reset a VT, double ventricular extrastimuli from the same site may reset the VT.

Cardiac Pacing, Artificial↗

Bombesin induces c-fos and c-myc expression in quiescent Swiss 3T3 cells. Comparative study with other mitogens.

We have studied the effect of the potent mitogen bombesin on the expression of c-fos and c-myc genes in quiescent mouse fibroblasts. We have demonstrated that bombesin rapidly induces a transient expression of c-fos mRNA followed by a more protracted elevation in c-myc mRNA levels. The intensity of the induction of expression of both proto-oncogenes depended on the dose of bombesin used. Prolonged treatment of the cells with TPA, which causes a selective decrease in protein kinase C activity, partially inhibited the induction of c-fos and c-myc gene expression by bombesin, similar to what has been observed with PDGF. However, a dramatic inhibition of the mitogenic response to bombesin--but not to PDGF--was found in TPA-treated cells. In contrast, TPA-treated cells showed an increased response to EGF with regard to proto-oncogene expression. The role of protein kinase C and Ca2+-dependent pathways in proto-oncogene induction by bombesin is discussed.

Animals↗

Cloning and sequence of the human nuclear protein cyclin: homology with DNA-binding proteins.

A full-length cDNA clone for the human nuclear protein cyclin has been isolated by using polyclonal antibodies and sequenced. The sequence predicts a protein of 261 amino acids (Mr 29,261) with a high content of acidic (41, aspartic and glutamic acids) versus basic (24, lysine and arginine) amino acids. The identity of the cDNA clone was confirmed by in vitro hybrid-arrested translation of cyclin mRNA. Blot-hybridization analysis of mouse 3T3 and human MOLT-4 cell RNA revealed a mRNA species of approximately the same size as the cDNA insert. Expression of cyclin mRNA was undetectable or very low in quiescent cells, increasing after 8-10 hr of serum stimulation. Inhibition of DNA synthesis by hydroxyurea in serum-stimulated cells did not affect the increase in cyclin mRNA but inhibited 90% the expression of H3 mRNA. These results suggest that expression of cyclin and histone mRNAs are controlled by different mechanisms. A region of the cyclin sequence shows a significant homology with the putative DNA binding site of several proteins, specially with the transcriptional-regulator cAMP-binding protein of Escherichia coli, suggesting that cyclin could play a similar role in eukaryotic cells.

Amino Acid Sequence↗

Influence of the site of stimulation on the resetting phenomenon in ventricular tachycardia.

Uniform, sustained ventricular tachycardia (VT) in the setting of prior myocardial infarction is believed to be due to reentry. The ability to reset VT with programmed extrastimuli requires that the premature impulse reach and enter the reentrant circuit. To evaluate the importance of the site of pacing on the ability to reset VT, single ventricular extrastimuli were delivered during 32 morphologically distinct, uniform VTs from both the right ventricular (RV) apex and RV outflow tract. Single ventricular extrastimuli resulted in resetting of VT from the RV apex only in 6 VTs, from the RV outflow tract only in 2, from both sites in 11 VTs and neither site in 13. When VT reset at both RV sites, 1 RV site or neither RV site was compared, a left bundle branch block VT QRS morphologic pattern was found to be more common in VT reset at both sites than at neither site (8 of 11 vs 4 of 13, p less than 0.05). No other differences in VT characteristics analyzed were found between these groups. Multiple ventricular extrastimuli were delivered in 16 VTs; in 6 of these, resetting was shown from at least 1 additional site, as compared to the response with single ventricular extrastimuli. In summary, site of stimulation can influence the ability of premature extrastimuli to reset uniform VT, and site dependence of VT resetting diminishes when multiple extrastimuli are used. This suggests that refractoriness or conduction delay in tissue between the pacing site and tachycardia circuit are important determinants of ability to reset VT from a particular site.

Atrioventricular Node↗

Hairpin loop structure of African swine fever virus DNA.

The ends of African swine fever virus genome are formed by a 37 nucleotide-long hairpin loop composed, almost entirely, of incompletely paired A and T residues. The loops at each DNA end were present in two equimolar forms that, when compared in opposite polarities, were inverted and complementary (flip-flop), as in the case of poxvirus DNA. The hairpin loops of African swine fever and vaccinia virus DNAs had no homology, but both DNAs had a 16 nucleotide-long sequence, close to the hairpin loops, with an homology of about 80%. An analysis of African swine fever virus replicating DNA showed head-to-head and tail-to-tail linked molecules that may be replicative intermediates.

African Swine Fever Virus↗

Transcription and translation maps of African swine fever virus.

A transcription map of African swine fever (ASF) virus DNA was obtained by hybridization of 32P-labeled early and late RNAs synthesized in Vero cells infected with ASF virus to dot-blots containing cloned restriction fragments spanning the viral genome. Early RNAs synthesized in infected cells in the presence of protein or DNA synthesis inhibitors hybridized preferentially to four regions in the genome, with coordinates E1 (0-51.9 kbp), E3 (63.7-75.2 kbp), E5 (100.1-111.6 kbp), and E7 (150-170 kbp). Late RNA present in infected cells after DNA replication hybridized with essentially all the genome. The RNA synthesized in vitro by the RNA polymerase associated with ASF virions hybridized to the same DNA regions than early RNA. After hybridization selection with DNA restriction fragments and translation in reticulocyte lysates the RNA synthesized in vitro produced the same proteins as early RNA. These results suggest that early RNA is synthesized in the infected cells by the virion-associated RNA polymerase. Maps of early and late proteins of ASF virus were constructed by cell-free translation of early or late RNAs selected by hybridization to cloned restriction fragments of virus DNA. About 100 early and 100 late polypeptide bands were mapped on the ASF virus genome.

Cell Line↗

Analysis of the resetting phenomenon in sustained uniform ventricular tachycardia: incidence and relation to termination.

UNLABELLED: Although the phenomenon of resetting has been studied in several experimental and clinical rhythms, it has not been systematically analyzed in ventricular tachycardia. To define the incidence and determinants of resetting as well as its relation to ventricular tachycardia termination, the response to programmed stimulation was prospectively studied during 78 electrically induced episodes of sustained, uniform ventricular tachycardia (mean cycle length 365 +/- 59 ms) in 53 patients. Single and double ventricular extrastimuli were introduced during 78 and 39 episodes of ventricular tachycardia, respectively. Rapid ventricular pacing was performed during 27 episodes. Resetting occurred in response to single ventricular extrastimuli in 43 (55%) of 78 ventricular tachycardias, to double extrastimuli in 31 (79%) of 39 ventricular tachycardias and to rapid pacing in 23 (85%) of 27 ventricular tachycardias. No ventricular tachycardia characteristic distinguished those tachycardias that were reset from those not reset. Termination of ventricular tachycardia occurred in 7 (9%) of 78 episodes with single ventricular extrastimuli, 14 (36%) of 39 episodes with double ventricular extrastimuli and 13 (48%) of 27 episodes with rapid pacing. Termination was less frequent than resetting with both single (9 versus 55%) and double (36 versus 79%) extrastimuli, as well as rapid pacing (48 versus 85%). Resetting preceded termination in 7 of 7 ventricular tachycardias terminated with single ventricular extrastimuli, 12 of 14 terminated with double ventricular extrastimuli and 9 of 13 terminated by rapid pacing. Ventricular tachycardias that were terminated could not be differentiated from those that were reset without termination. IN CONCLUSION: Resetting with programmed extrastimuli is common in hemodynamically stable sustained ventricular tachycardia.(ABSTRACT TRUNCATED AT 250 WORDS)

Cardiac Pacing, Artificial↗

Resetting response patterns during sustained ventricular tachycardia: relationship to the excitable gap.

We analyzed the resetting response (a noncompensatory pause after electrical stimulation) during 37 hemodynamically tolerated ventricular tachycardias (VTs) induced by programmed electrical stimulation in 32 patients with chronic coronary artery disease. The mean cycle length of VT was 369 +/- 59 msec. Single extrastimuli were delivered at the right ventricular apex during all 37 VTs, and double extrastimuli were delivered at the same site during 23 VTs. The resetting response pattern was considered increasing, decreasing, or flat if the return cycle increased, decreased, or remained constant in response to progressively shorter coupling intervals of the extrastimuli. Ten VTs had an increasing pattern and nine a flat pattern. In 11 VTs the pattern was mixed (flat at longer coupling intervals and increasing at shorter ones), and in the remaining seven the pattern could not be defined. No VT had a decreasing pattern. The mean duration of the resetting interval (range of coupling intervals resulting in resetting) was 66 +/- 45 msec, or 17% of the cycle length of VT. VT with a mixed pattern had longer resetting intervals than VT with an increasing pattern (102 +/- 34 vs 64 +/- 40 msec; p less than .035); however, cycle lengths of VT were similar (370 +/- 58 vs 386 +/- 86, p = NS). An excellent correlation was observed between the shortest return cycles in response to single and double extrastimuli (r = .99), with a mean difference of 5 msec. The cycle length of VT exceeded the return cycle (measured to the QRS onset) during 15 VTs (41%).(ABSTRACT TRUNCATED AT 250 WORDS)

Cardiac Pacing, Artificial↗