Automated analytical systems for drug development studies. I--A system for the determination of drug stability.

An automated system consisting of a pH-stat, microdialysis sampling and a liquid chromatograph was assembled to measure the rate of rapid chemical reactions. 2',3',5'-Triacetyl-6-azauridine was used as a model compound to validate the performance of the automated system. Buffer catalysis was minimized by using a non-catalytic concentration of borate buffer along with a pH-stat to maintain the pH during the kinetic run. The microdialysis sampling technique permitted sample quenching and buffering of the solutions to a pH compatible with the LC column materials. The combination of microdialysis sampling and rapid LC analysis allowed reactions with a half-life of approximately 1 min to be sampled every 30 s. The rates of hydrolysis of the drug, measured at different conditions of temperature (37-70 degrees C) and pH (9.0-10.5) using the automated system, compared well with the previously determined values.

Autoanalysis↗

Dermal microdialysis sampling in vivo.

Microdialysis sampling of the dermis in vivo was accomplished using a linear microdialysis probe. In contrast to previous studies using a commercial cannula-style microdialysis probe, the linear probe had no effect on the flux of drug through the skin in vitro. The extent of tissue damage in vivo due to probe implantation was evaluated by histological examination and microdialysis delivery studies. Tissue damage due to implantation of the linear probe was minimal with no bleeding or edema observed. Infiltration of lymphocytes into the tissue was observed beginning 6 hours after probe implantation with scar tissue beginning to form after approximately 32 hours. The infiltration of lymphocytes had no effect on the behavior of implanted microdialysis probes. Delivery of 5-fluorouracil was between 20 and 25% for six different probes implanted in six different animals demonstrating good probe-to-probe and implantation-to-implantation reproducibility. Constant delivery was maintained for at least 24 hours in all cases indicating that experiments of at least 24 hour duration are feasible. The dermal concentration of topically applied 5-FU cream, Efudex, was continuously monitored by an implanted microdialysis probe demonstrating the feasibility of this technique as for monitoring skin drug levels in vivo. The dermal concentration of 5-FU following topical application was approximately 40-fold higher for in vitro excised skin than for in vivo intact skin.

Animals↗

Microdialysis sampling for the investigation of dermal drug transport.

Microdialysis perfusion in vivo has the potential to be a powerful sampling technique in dermal and transdermal drug delivery studies. Characterization of a commercially available microdialysis probe in vitro considering relevant physiological parameters is a vital first step in the evaluation of microdialysis as a dermal sampling technique. In previous microdialysis studies, analyte concentration and neutrality have been implicated in altering microdialysis recovery. The recovery of a model compound 5-fluorouracil (5-FU) was investigated at several pH values and donor concentrations. The relative recovery of 5-FU by the microdialysis probe was affected by pH but not by donor concentration. To confirm further that the changing concentration and pH profile presented by the flux of 5-FU was not significantly altering microdialysis recovery, an experiment comparing direct and microdialysis sampling of a Franz diffusion cell receptor compartment was performed. Although the 5-FU concentration (0-686 ng/ml) and pH (7.40-7.24) changed substantially, the recovery of 5-FU was not adversely affected. To demonstrate the feasibility of dermal microdialysis, the flux of a commercial preparation of 5-fluorouracil was monitored utilizing a microdialysis probe implanted in excised rat skin in vitro. The results from the dermally implanted probe demonstrate the potential of the technique while establishing the limitations of the current microdialysis system.

Animals↗

Chromatographic methods for the bioanalysis of antiviral agents.

The present review has concentrated on chromatographic techniques for the quantitative determination of antiviral drugs in biological samples. Special attention has been paid to the elements of chromatographic assays that are essential to ensure selectivity, sensitivity, accuracy and precision of the various methods. Wherever possible, attempts have been made to determine the suitability of the methods for application to investigations in pharmacokinetics in man and experimental animals, biopharmaceutics, therapeutic drug monitoring, metabolism and pharmacology. Because of the serious consequences of infection from material contaminated with viruses, special consideration has been given to the handling of contaminated samples. It was convenient to divide the antiviral drugs for the purpose of this review into two groups, the nucleoside and the non-nucleoside antiviral drugs. The nucleosides discussed are vidarabine, cytarabine, ribavirin, riboxamide, acyclovir, ganciclovir, desciclovir, carbovir, 2',3'-dideoxyadenosine, 2',3'-dideoxycytidine, zidovudine, 2',3'-dideoxyinosine, 2',3'-didehydro-3'-deoxythymidine, idoxuridine, 5-(2-bromovinyl)-2'-deoxyuridine, 2'-fluoro-5-iodoaracytidine and 5-iodo-2'-deoxycytidine. The non-nucleoside antiviral drugs discussed are arildone, amantidine, rimantidine, moroxydine, enviroxime, foscarnet and ampligen.

Antiviral Agents↗