PubMed Health⌕ Search

Biomedical subjects

J M Borsboom

Publications and source records attributed to J M Borsboom.

2 recordsLinked to original sources

Flow estimation using an intravascular imaging catheter.

Coronary flow assessment can be useful for determining the hemodynamic severity of a stenosis and to evaluate the outcome of interventional therapy. We developed a method for measuring the transverse flow through the imaging plane of an intravascular ultrasound (IVUS) catheter. This possibility has raised great clinical interest since it permits simultaneous assessment of vessel geometry and function with the same device. Furthermore, it should give more accurate information than combination devices because lumen diameter and velocity are determined at the same location. Flow velocity is estimated based on decorrelation estimation from sequences of radiofrequency (RF) traces acquired at nearly the same position. Signal gating yields a local estimate of the velocity. Integrating the local velocity over the lumen gives the quantitative flow. This principle has been calibrated and tested through computer modeling, in vitro experiments using a flow phantom and in vivo experiments in a porcine animal model, and validated against a Doppler element containing guide wire (Flowire) in humans. Originally the method was developed and tested for a rotating single element device. Currently the method is being developed for an array system. The great advantage of an array over the single element approach would be that the transducer has no intrinsic motion. This intrinsic motion sets a minimal threshold in the detectable velocity components. Although the principle is the same, the method needs some adaptation through the inherent different beamforming of the transducer. In this paper various aspects of the development of IVUS flow are reviewed.

Animals↗

Simulation of circular array ultrasound transducers for intravascular applications.

The beam shape of a circular array transducer that is commonly used in intravascular ultrasound catheters was investigated in linear mode of operation. For this use, a simulation program which can simulate the radio frequency (rf)-response of a number of scatterers has been developed. The program is based on the impulse response method, which is implemented in the frequency domain. Due to the unusual geometry of the transducer, the far field gets peculiarly shaped for large apertures. Instead of having a far field with its maximum intensity in a single lobe on the acoustical axis, the far field splits up into a dual-lobe far field with maximum intensity in two lobes off the acoustical axis. A formula is derived that predicts the occurrence of these beam shapes.

Coronary Vessels↗