PubMed Health⌕ Search

Biomedical subjects

J M Brisson

Publications and source records attributed to J M Brisson.

3 recordsLinked to original sources

Quantitative screening and matrix effect studies of drug discovery compounds in monkey plasma using fast-gradient liquid chromatography/tandem mass spectrometry.

A higher-throughput bioanalytical method based on fast-gradient (1 min run time) high-performance liquid chromatography (HPLC) coupled with tandem mass spectrometry (MS/MS) was developed for screen-type analyses of plasma samples from early drug discovery studies in support of exploratory pharmacodynamic studies. The HPLC system equipped with minibore column was interfaced with either atmospheric pressure chemical ionization (APCI) or electrospray (ESI) ionization techniques. The matrix ion suppression effect of both quantitative HPLC/MS/MS analyses was compared using the post-column infusion system. The use of the described methods provided advantages such as a shorter chromatographic region of ion suppression, less solvent consumption and shorter run times in comparison with standard analytical column HPLC/MS/MS methods. The analytical results obtained by both HPLC/MS/MS methods were in good agreement (within 15% of error) and displayed a good correlation with the pharmacodynamic outcome.

2-Hydroxypropyl-beta-cyclodextrin↗

Direct simultaneous analysis of plasma samples for a drug discovery compound and its hydroxyl metabolite using mixed-function column liquid chromatography-tandem mass spectrometry.

A polymer-coated mixed-function (PCMF) column was evaluated for direct plasma injection for the simultaneous determination of a drug candidate and its hydroxyl metabolite by high-performance liquid chromatography (HPLC) with tandem mass spectrometry (MS-MS) in support of pharmacokinetic studies. Each diluted monkey plasma sample containing internal standard was directly injected on to the PCMF column for sample clean-up, enrichment and chromatographic separation. The proteins and macromolecules were first eluted from the column while the drug molecules were retained on the bonded hydrophobic phase. The analytes retained on the column were then eluted with a strong mobile phase using a gradient separation technique at a constant flow rate of 1.0 ml min(-1). When not diverted, the column effluent was connected either to the atmospheric pressure chemical ionization (APCI) source or the electrospray ionization (ESI) source as part of the mass spectrometer system used for quantification. The calibration curve was linear over the range 5-2500 ng ml(-1) for both analytes. The retention times for the analytes and the internal standard were both consistent and no column deterioration was observed for at least 500 injections. The recovery through the column and reproducibility of the dosed compound and its hydroxyl metabolite in monkey plasma samples were > 90% (RSD < 6%). The total analysis time was < 8 min per sample. The analytical results obtained by the proposed direct plasma injection method were in good agreement with those obtained by the conventional LC-MS-MS method.

Chromatography, Liquid↗

Direct analysis of plasma samples for drug discovery compounds using mixed-function column liquid chromatography tandem mass spectrometry.

A sensitive, efficient, high throughput, direct injection bioanalytical method based on a single column and high-performance liquid chromatography (HPLC) with tandem mass spectrometry (MS/MS) was developed for pharmacokinetic analysis of early drug discovery compounds in plasma samples. After mixing with a working solution containing an internal standard each plasma sample was directly injected into a polymer-coated mixed-function column for sample cleanup, enrichment and chromatographic separation. The stationary phase incorporates hydrophilic polyoxyethylene groups and hydrophobic groups to the polymer-coated silica. This allows proteins and macromolecules to pass through the column due to restricted access to the surface of the packing while retaining the drug molecules on the bonded hydrophobic phase. The analytes retained in the column with a largely aqueous liquid mobile phase were then chemically separated by switching to a strong organic mobile phase. The column effluent was diverted from waste to the mass spectrometer for analyte detection. Within 200 plasma sample injections the response ratio (analyte vs. internal standard, %CV = 4.6) and the retention times for analyte and internal standard were found consistent and no column deterioration was observed. The recoveries of test compound in various plasma samples were greater than 90%. The total analysis time was </=5 min per sample.

Animals↗