PubMed Health⌕ Search

Biomedical subjects

J M Cano Pavón

Publications and source records attributed to J M Cano Pavón.

14 recordsLinked to original sources

Lead ultra-trace on-line preconcentration and determination using selective solid phase extraction and electrothermal atomic absorption spectrometry: applications in seawaters and biological samples.

In this work, a new chelating resin [1,5-bis (2-pyridyl)-3-sulphophenyl methylene] thiocarbonohydrazide immobilised on aminopropyl-controlled pore glass (550 A; PSTH-cpg) was synthesised and packed in a microcolumn which replaced the sample tip of the autosampler arm. The system was applied to the preconcentration of lead. When microliters of 10% HNO3, which acts as elution agent, pass through the microcolumn, the preconcentrated Pb(II) is eluted and directly deposited in a tungsten-rhodium coated graphite tube. With the use of the separation and preconcentration step and the permanent modifiers, the analytical characteristics of the technique were improved. The proposed method has a linear calibration range from 0.012 to 10 ng ml(-1) of lead. At a sample frequency of 36 h(-1) with a 90 s preconcentration time, the enrichment factor was 20.5, the detection and determination limits were 0.012 and 0.14 ng ml(-1), respectively and the precision, expressed as relative standard deviation, was 3.2% (at 1 ng ml(-1)). Results from the determination of Pb in biological certified reference materials were in agreement with the certified values. Seawaters and other biological samples were analysed too.

Calibration↗

Chelating sorbents based on silica gel and their application in atomic spectrometry.

This mini-review covers chelating sorbents anchored to silica gel and their analytical applications for the preconcentration, separation and determination of trace metal ions, focussing mainly on the last 20 years. The article summarizes also the experience gathered by our research group in the synthesis and characterization of new modified silica gels "via silanization", and their affinity toward selective extraction and separation of trace elements. The introduction of 1,5-bis(di-2-pyridyl)methylene thiocarbohydrazide silica gel (DPTH-gel) and methylthiosalicylate silica gel (TS-gel) chelating sorbents in trace and ultratrace analysis provide vital breakthroughs in preconcentration methods. These home-made materials allow certain analytes to be selectively extracted from complex matrices without matrix interference and good detection limits. The advantages of these new chelating sorbents in comparison with 8-hydroxyquinoline chelating sorbent immobilized on silica gel are discussed.

Chelating Agents↗

Use of 1,5-bis(di-2-pyridyl)methylene thiocarbohydrazide immobilized on silica gel for automated preconcentration and selective determination of antimony(III) by flow-injection electrothermal atomic absorption spectrometry.

Selective sorption of Sb(III) on a microcolumn packed with 1,5-bis(di-2-pyridyl)methylene thiocarbohydrazide immobilized on silica gel (DPTH-gel) has been used for determination of Sb(III). A flow-injection system comprising a microcolumn connected to the tip of the autosampler was used for preconcentration. The sorbed antimony was eluted with nitric acid directly into the graphite furnace and determined by AAS. The detection limit for antimony under the optimum conditions was 0.3 ng mL(-1). This procedure was used for determination of antimony in natural water, soil, vegetation, and a certified sample of a city waste incineration ash (BCR 176).

Journal Article↗

On-line ion-exchange preconcentration and determination of traces of platinum by electrothermal atomic absorption spectrometry.

A method to determine trace amounts of platinum in different samples based on electrothermal atomic absorption spectrometry is described. The preconcentration step is performed on a chelating resin microcolumn [1,5-bis(2-pyridyl)-3-sulfophenyl methylene thiocarbonohydrazide (PSTH) immobilized on an anion-exchange resin (Dowex 1x8-200)] placed in the autosampler arm. The combination of a peristaltic pump for sample loading and the atomic absorption spectrometer pumps for elution through a selection valve simplifies the hardware. The peristaltic pump and the selection valve are easily controlled electronically with two switches placed in the autosampler, which are activated when the autosampler arm is down. Thus, the process is fully automated without any modification of the software of the atomic absorption spectrometer. Under the optimum conditions with a 60-s preconcentration time, a sample flow rate of 2.4 mL min(-1), and an injection volume of eluent of 40 microL, a linear calibration graph was obtained in the range 0-100 ng mL(-1). The enrichment factor was 14. The detection limit under these conditions is 1 ng mL(-1), and the relative standard deviation (RSD) is 1.6% for 10 ng mL(-1) of Pt. The method has been applied to the determination of platinum in catalyst, vegetation, soil, and natural water samples. The results showed good agreement with the certified value and the recoveries of Pt added to samples were 98-105%.

Ions↗

[Chemistry research in Granada during the 20th century (1900-1975)].

We studied the development of chemistry research in Granada from 1900 to 1975. Initially we obtained quantitative data on publication output during three arbitrarily-defined subperiods (1900-1936, 1937-1955, and 1956-1975). The most important lines of chemistry research at university and national research council (CSIC) centers in Granada are described, and some considerations on the characteristics of these publications are provided. Scientific research slowly became consolidated during the 1930s. The Civil War led to substantial changes, and during the postwar years the influence of the CSIC led to the predominance of studies on silicates and clays (mineralogy, reactivity, applications) until well into the 1960s. After 1965 research lines became more diversified, with increasing numbers of studies in biochemistry, physiology and analytical chemistry.

Chemistry↗

Determination of nickel in biological materials after microwave dissolution using inductively coupled plasma atomic emission spectrometry with prior extraction into butan-1-ol.

A sensitive procedure has been developed for the determination of ultratrace amounts of nickel in biological materials by inductively coupled plasma atomic emission spectrometry after extraction of the nickel ion into butan-1-ol by using 1,5-bis(di-2-pyridylmethylene)thiocarbonohydrazide as the extracting reagent. Fast, efficient and complete sample digestion is achieved by an HNO3-HCl poly(tetrafluoroethylene) bomb dissolution technique using microwave heating. Results obtained for eleven certified reference materials agreed with the certified values.

Animals↗

Determination of cadmium in biological samples by inductively coupled plasma atomic emission spectrometry after extraction with 1,5-bis(di-2-pyridylmethylene) thiocarbonohydrazide.

An inductively coupled plasma atomic emission spectrometric method for the determination of trace amounts of cadmium after extraction of the metal into isobutyl methyl ketone containing 1,5-bis(di-2-pyridylmethylene) thiocarbonohydrazide is described. The optimum extraction conditions were evaluated from a critical study of the effects of pH, concentration of extractant, shaking time and ionic strength. The detection limit for cadmium is 0.1 ng ml-1 and the calibration is linear from 0.2 to 140 ng ml-1. The relative standard deviation for ten replicate measurements is 2.9% for 2 ng ml-1 of cadmium. Results from the analysis of some certified biological reference materials are given.

Animals↗

Separation preconcentration method for platinum and rhodium from environmental samples using a chelating resin.

A method of determining trace levels of platinum and rhodium in different samples was investigated. The method involves separation and preconcentration of the platinum and rhodium from the matrix by flow injection (FI) on-line coupled with electrothermal atomic absorption spectrometry (ETAAS) with Zeeman effect background correction. Platinum and rhodium were adsorbed on a microcolumn packed with 1,5-bis(di-2-pyridyl)methylene thiocarbohydrazide immobilized on silica gel (DPTH-gel). The sorbed metals were directly eluted with nitric acid into the graphite furnace and determined by AAS.

Animals↗