PubMed Health⌕ Search

Biomedical subjects

J M Choe

Publications and source records attributed to J M Choe.

18 recordsLinked to original sources

Preventing urethral obstruction using the 6-point fixation and weight-adjusted spacing nomogram during sling surgery.

The aim of the study was to assess the outcome of a 6-point fixation technique and weight-adjusted spacing nomogram for performing sling surgery. Fifty women with stress incontinence underwent implantation of a Gore-tex patch sling. Sling tension was gauged based on the patient's body weight. Postoperative analysis was performed using cough stress tests, Q-tip tests, pelvic examinations and patient satisfaction questionnaires. Urodynamics were performed for women with persistent incontinence. Mean follow-up was 24 months (range 7-28). Mean age was 58 years (range 29-87). Stress incontinence was cured in 47/50 patients (94.0%). De novo urge incontinence occurred in 1/23 (4.3%) patients. Mean time to suprapubic tube removal was 7 days (range 1-21). No patients experienced urinary retention or urethral obstruction. Mean satisfaction score was 9/10 (range 7-10) and all patients said they would undergo surgery again. The combination of a 6-point fixation technique and a weight-adjusted spacing nomogram allows for a successful sling outcome without obstruction.

Adult↗

Autologous, cadaveric, and synthetic materials used in sling surgery: comparative biomechanical analysis.

OBJECTIVES: To compare the biomechanical properties of allografts, autografts, and synthetic materials used in sling surgery using the Instron tensinometer. METHODS: The sling grafts we studied consisted of autologous tissues (dermis, rectus fascia, and vaginal mucosa), cadaver tissues (decellularized dermis and freeze-dried, gamma-irradiated fascia lata), and synthetics (Gore-Tex and polypropylene mesh). The sling grafts were constructed into two types of slings: full strip sling (FSS) versus patch suture sling (PSS). The slings were loaded onto the Instron tensinometer and uniaxially loaded in tension until failure. From the load deformation curve, the mechanical properties of the sling grafts were compared. RESULTS: A total of 140 sling grafts were analyzed. In rank order for the FSSs, cadaver allografts had the strongest tensile strength followed by the synthetics and autologous tissues (P <0.05). The tensile strength of the FSSs was greater than for the PSSs for all groups (P </=0.001). In rank order for the PSSs, the synthetics and dermal tissues (autograft and allograft) had the highest tensile strength followed by cadaver fascia lata, rectus fascia, and vaginal mucosa (P <0.05). CONCLUSIONS: The tensile strength of the FSS was greater than that of the PSS for the autograft, allograft, and synthetic tissues. The autograft and allograft tissues were significantly weaker as a PSS. The synthetics were more durable as a PSS compared with the organic tissues. When a PSS is constructed from autograft and allograft tissues, the risk of suture pull-through and recurrent stress incontinence must be considered.

Biomechanical Phenomena↗

Genetic material is present in cadaveric dermis and cadaveric fascia lata.

PURPOSE: We determined whether genetic material is present in the commercially processed cadaveric allografts used in sling surgery. MATERIALS AND METHODS: We evaluated 16 samples from 2 commercial sources of human allograft, including 8 each of freeze-dried gamma irradiated cadaveric fascia lata and acellular cadaveric dermis. Fresh human rectus fascia and sterile saline served as positive and negative controls, respectively. All samples underwent a standard proteinase K/sodium dodecyl sulfate/phenol extraction technique to isolate DNA. Polymerase chain reaction was done to amplify the retrieved DNA material, spectrophotometry to quantify DNA concentration and agarose gel electrophoresis to determine the size of DNA fragments. RESULTS: Of the 16 samples tested from 2 commercial sources of human allograft fascia 14 (87.5%) contained DNA. Mean DNA concentration plus or minus standard error was 258.3 +/- 80.1 and 272.8 +/- 168.8 microg./gm. tissue for cadaveric fascia lata and cadaveric dermis, respectively. Polymerase chain reaction amplified DNA segments of 2,000 bp from 1 of each of the 8 samples of cadaveric fascia lata and cadaveric dermis. CONCLUSIONS: Freeze-dried gamma irradiated cadaveric fascia lata and acellular cadaveric dermis contained intact DNA.

Bioprosthesis↗

Paraphimosis: current treatment options.

Paraphimosis is a urologic emergency, occurring in uncircumcised males, in which the foreskin becomes trapped behind the corona and forms a tight band of constricting tissue. Often iatrogenically induced, paraphimosis can be prevented by returning the prepuce to cover the glans following penile manipulation. Treatment often begins with reduction of edema, followed by a variety of options, including mechanical compression, pharmacologic therapy, puncture technique and dorsal slit. Prevention and early intervention are key elements in the management of paraphimosis.

Humans↗

Retrograde perfusion sphincterometry with a flexible cystoscope: method of troubleshooting the AMS 800.

We developed the technique of retrograde perfusion sphincterometry to troubleshoot the AMS 800 device. We implanted artificial urinary sphincters in men who were incontinent after prostatectomy and performed intraoperative retrograde perfusion sphincterometry. Retrograde perfusion sphincterometry using a flexible cystoscope is simple and allows early recognition of intraoperative urethral injury and mechanical malfunction.

Aged↗

Antibacterial mesh sling: a prospective outcome analysis.

OBJECTIVES: To prospectively assess the outcome results of the Gore-Tex antibacterial mesh sling in women with pelvic prolapse and stress incontinence. METHODS: Between July 1997 and November 1998, 30 women with stress incontinence and vaginal prolapse underwent vaginal reconstruction with the antibacterial mesh sling. All patients had documented stress incontinence by preoperative urodynamic evaluation. Postoperatively, we conducted an outcome analysis on the basis of the results from a self-reported satisfaction questionnaire, a detailed pelvic examination, a cough stress test, and the Q-tip test. Urodynamic studies were performed on patients with persistent stress incontinence or urge symptoms. Cystoscopy was performed on patients suspected of having urethral erosion. RESULTS: Complete follow-up was available for all 30 patients. Of the group, 12 (40.0%) of 30 underwent implantation of the antibacterial mesh sling alone and 18 (60.0%) underwent additional prolapse repair. The mean follow-up was 18 months (range 9 to 24); mean age was 58 years (range 29 to 87). Stress incontinence was cured in 28 (93.3%) of 30 patients. De novo urge incontinence developed in 1 (5.2%) of 18 patients; urge symptoms persisted in 5 (41.7%) of 12 patients. The postoperative mean Valsalva Q-tip angle was 15 degrees (range 0 degrees to 25 degrees ). The incidence of urethral obstruction and erosion was zero. The mean postoperative pain score was 3 of 10 (range 0 to 6), and the mean satisfaction score was 9 of 10 (range 7 to 10). The mean time to discharge was 21 hours (range 6 to 29). All 30 women (100%) were willing to undergo surgery again. CONCLUSIONS: The safety profile of the Gore-Tex antibacterial mesh is better than that of the conventional Gore-Tex sling. When meticulous surgical technique is used, excellent short-term results can be achieved in the correction of female stress incontinence.

Adult↗

Antimicrobial mesh versus vaginal wall sling: a comparative outcomes analysis.

PURPOSE: We prospectively compared transvaginal antimicrobial mesh (MycroMesh*) and anterior vaginal wall slings using an outcomes analysis. MATERIALS AND METHODS: Between August 1997 and November 1998 we implanted transvaginal slings in 40 consecutive women randomized to a synthetic mesh (20) or vaginal wall (20) group. All patients had documented stress urinary incontinence on preoperative urodynamics. We prospectively compared postoperative outcomes data obtained from pelvic examinations, cough stress test, cotton swab test and validated patient questionnaires using a visual analog scale. RESULTS: Complete followup was available in all patients. Mean followup was 22 months (range 12 to 27). Stress incontinence was cured in 95% of the mesh and 70% of the vaginal wall group, and pelvic prolapse was cured in 100% and 95%, respectively. Transient de novo urge incontinence was noted in 12.5% of the mesh and 14.3% of the vaginal wall group. Mean postoperative cotton swab angle during Valsalva's maneuver was 20 and 45 degrees for the mesh and vaginal wall groups, respectively. The incidence of urinary retention and tissue erosion was 0% for both groups. The satisfaction rate was 100% and 80% for the mesh and vaginal wall groups, respectively. CONCLUSIONS: The antimicrobial MycroMesh sling was superior to the vaginal wall sling for correction of stress incontinence and pelvic prolapse with comparatively low morbidity.

Adolescent↗

Gore-Tex patch sling: 7 years later.

OBJECTIVES: To assess the long-term results of a transvaginal endoscopic Gore-Tex patch sling in women with genuine stress urinary incontinence due to urethral hypermobility and/or intrinsic sphincter deficiency, with or without coexistent urge incontinence. METHODS: Between December 1989 and June 1994, we performed a Gore-Tex patch sling procedure in 141 consecutive women. All patients had documented stress urinary incontinence on preoperative videourodynamic testing. We conducted outcomes analysis using the information from postoperative office visits, detailed chart reviews, patient questionnaires, and telephone surveys. RESULTS: A complete follow-up was available in 90 patients. The mean follow-up was 51 months (range 27 to 84). Their mean age was 54.2 years (range 32 to 86). Stress incontinence was completely cured in 80 (88.9%) of 90 patients. Pure stress incontinence persisted in 4 (4.4%) of 90 patients. Mixed incontinence occurred in 6 (6.7%) of 90 patients. Pure urge incontinence was experienced by 16 (17.8%) of 90 patients. Six patients required incision of the Gore-Tex patch for obstruction or retention; 3 remain continent. Five patients developed vaginal granulation tissue requiring Gore-Tex patch removal; 1 remains continent. There was no bladder or urethral erosion. CONCLUSIONS: The transvaginal Gore-Tex patch sling has provided durable efficacy with minimal morbidity for the treatment of stress urinary incontinence due to anatomic urethral hypermobility and/or intrinsic sphincter deficiency.

Adult↗

A provocative maneuver to elicit cystometric instability: measuring instability at maximum infusion.

PURPOSE: We identify a provocative maneuver to enhance the sensitivity of cystometry in detecting detrusor instability when urge incontinence is suspected based on clinical history. MATERIALS AND METHODS: A total of 134 consecutive women with clinical urge incontinence underwent carbon dioxide cystometry between August 1995 and October 1996. The bladder was filled to maximal capacity with the patient supine. Six provocative maneuvers were performed consecutively to evoke detrusor instability, including lying supine, rising to a seated position, walking toward the bathroom, handwashing, coughing and sitting on the toilet with instructions not to void. Subjects were divided into 2 groups depending on the order of maneuvers. Sitting on the toilet was the last maneuver for group 1 (80 patients) and was in the middle of the sequence for group 2 (54). RESULTS: Sitting on the toilet evoked detrusor instability in 37.5% of group 1 and 53.8% of group 2. This maneuver with instructions not to void was the most provocative stimulus in eliciting detrusor instability with a detection rate of 68.4% for all subjects. CONCLUSIONS: Sitting on the toilet with the bladder at maximal capacity is the most provocative maneuver for detecting detrusor instability. The incidence of suspected detrusor instability is enhanced by using this test during routine cystometry.

Female↗

The Gore-tex sling procedure for female sphincteric incontinence: indications, technique, and results.

We constructed a pubovaginal sling using the Gore-tex Soft Tissue Patch and 2-0 polytetrafluoroethylene (PTFE) suspension suture and placed it in 122 consecutive incontinent women with urethral hypermobility and/or intrinsic sphincter deficiency. We performed a retrospective outcome analysis using a questionnaire-based telephone survey. The mean follow-up period was 24.4 months. Stress incontinence was cured in 88% of patients (equally effective in type II and type III incontinence), de novo postoperative urinary frequency occurred in 32% of cases, and preoperative urinary frequency resolved postoperatively in 51% of patients. Significant urinary obstruction occurred in 5% of patients. Vaginal granulation tissue with exposed sling occurred in 4% of patients. There was no urethral or bladder erosion. The treatment of female stress incontinence with a PTFE sling is effective and durable with minimal complications. Furthermore, this technique addresses many of the presumed technical shortcomings of endoscopic needle suspensions.

Female↗

Clinical usefulness of urinary control urethral insert devices.

Urinary control urethral insert devices have been introduced as a non-surgical remedy to treat female urinary incontinence. Several early clinical trials have demonstrated the degrees of safety and efficacy, and have defined the morbidity and complications of these urethral inserts. This is a descriptive review of urethral insert devices in clinical use or currently undergoing clinical investigation.

Female↗

Artificial urinary sphincter: evolution and development.

The first hydraulic artificial urinary sphincter came into clinical use in 1972. The original prototype has undergone many modifications resulting from advances in mechanical design, applications of new technology, and clinical experience. This evolutionary process has culminated in the AS800, the most frequently used hydraulic artificial urinary sphincter in the U.S. today. Although the AS800 device most closely approximates the biological urinary sphincter, clinical demands for an ever more ideal urinary sphincter require the ongoing improvement of this device.

Equipment Design↗

High-energy visual laser ablation of the prostate in men with urinary retention: pressure-flow analysis.

OBJECTIVES: To assess the efficacy of high-energy visual laser ablation of the prostate (VLAP) in men with urinary retention, using subjective and objective data. METHODS: Seventeen men in urinary retention underwent high-energy VLAP. The mean patient age was 69 years, and the mean follow-up was 12 months. All men were urodynamically obstructed by pressure-flow analysis with a functioning detrusor muscle. Interviews assessed retrograde ejaculation and patient satisfaction. RESULTS: The mean total energy applied was 71,088 J (range 27,556 to 110,294). The mean peak noninvasive urine flow rates increased from 2.1 to 18.1 cc/s, and the mean postvoid residual volumes decreased from 550.0 to 39.0 cc. The mean detrusor pressure at peak flow decreased from 66.4 to 41.9 cm H2O, and the mean maximal detrusor pressure decreased from 72.2 to 49.2 cm H2O. Ten men (59%) voided to completion within 1 week post-VLAP. The mean postoperative International Prostate Symptom Score was 6. Nine men (53%) reported new retrograde ejaculation, and 14 men (82%) were satisfied with their outcome. CONCLUSIONS: High-energy VLAP is an effective procedure for relief of bladder-outlet obstruction in men with urinary retention.

Aged↗

Questionnaire-based outcomes study of nononcological post-vasectomy complications.

PURPOSE: We conducted an outcomes analysis to determine the incidence of post-vasectomy complications. MATERIALS AND METHODS: A questionnaire (154 questions) addressing post-vasectomy complications, incidence of post-vasectomy scrotal pain and quality of life issues was sent to 470 patients. Followup telephone surveys were made. RESULTS: A total of 182 patients (42.3%) responded. Mean follow-up was 4.8 years. The most common complication was post-vasectomy scrotal pain in 34 men (18.7%), which adversely affected the quality of life in 4 (2.2%). In retrospect, 71.4% of the men were satisfied with the decision for vasectomy, 19.3% had equivocal feelings and 9.3% were dissatisfied. CONCLUSIONS: Chronic scrotal pain is the most common post-vasectomy complication that may adversely affect quality of life in men undergoing vasectomy.

Adult↗

Intravesical thiotepa-induced eosinophilic cystitis.

Eosinophilic cystitis is a rare form of an allergic cystitis. Factors such as food allergens, parasites, and drugs have been implicated in the genesis of eosinophilic cystitis. Associated risk factors include bronchial asthma, atopic diseases, and environmental allergens. Intravesical mitomycin is a reported causative agent. We report the first case of eosinophilic cystitis that developed after intravesical instillation of thiotepa for treatment of superficial bladder cancer.

Adult↗